Supernova Neutrino Detection in LZ
Authors:
Dev Ashish Khaitan
Abstract:
In the first 10 seconds of a core-collapse supernova, almost all of its progenitor's gravitational potential, O(10$^{53}$~ergs), is carried away in the form of neutrinos. These neutrinos, with O(10~MeV) kinetic energy, can interact via coherent elastic neutrino-nucleus scattering (CE$ν$NS) depositing O(1~keV) in detectors. In this work, we demonstrate that low-background dark matter detectors, suc…
▽ More
In the first 10 seconds of a core-collapse supernova, almost all of its progenitor's gravitational potential, O(10$^{53}$~ergs), is carried away in the form of neutrinos. These neutrinos, with O(10~MeV) kinetic energy, can interact via coherent elastic neutrino-nucleus scattering (CE$ν$NS) depositing O(1~keV) in detectors. In this work, we demonstrate that low-background dark matter detectors, such as LUX-ZEPLIN (LZ), optimized for detecting low-energy depositions, are capable of detecting these neutrino interactions. For instance, a 27~M$_\odot$ supernova at 10~kpc is expected to produce $\sim$350 neutrino interactions in the 7-tonne liquid xenon active volume of LZ. Based on the LS220 EoS neutrino flux model for a SN, the Noble Element Simulation Technique (NEST), and predicted CE$ν$NS cross-sections for xenon, to study energy deposition and detection of SN neutrinos in LZ. We simulate the response of the LZ data acquisition system (DAQ) and demonstrate its capability and limitations in handling this interaction rate. We present an overview of the LZ detector, focusing on the benefits of liquid xenon for supernova neutrino detection. We discuss energy deposition and detector response simulations and their results. We present an analysis technique to reconstruct the total number of neutrinos and the time of the supernova core bounce.
△ Less
Submitted 17 January, 2018;
originally announced January 2018.
Signal Processing and Electronic Noise in LZ
Authors:
Dev Ashish Khaitan
Abstract:
The electronics of the LUX-ZEPLIN (LZ) experiment, the 10-tonne dark matter detector to be installed at the Sanford Underground Research Facility (SURF), consists of low-noise dual-gain amplifiers and a 100-MHz, 14-bit data acquisition system for the TPC PMTs. Pre-prototypes of the analog amplifiers and the 32-channel digitizers were tested extensively with simulated pulses that are similar to the…
▽ More
The electronics of the LUX-ZEPLIN (LZ) experiment, the 10-tonne dark matter detector to be installed at the Sanford Underground Research Facility (SURF), consists of low-noise dual-gain amplifiers and a 100-MHz, 14-bit data acquisition system for the TPC PMTs. Pre-prototypes of the analog amplifiers and the 32-channel digitizers were tested extensively with simulated pulses that are similar to the prompt scintillation light and the electroluminescence signals expected in LZ. These studies are used to characterize the noise and to measure the linearity of the system. By increasing the amplitude of the test signals, the effect of saturating the amplifier and the digitizers was studied. The RMS ADC noise of the digitizer channels was measured to be 1.19 $\pm$ 0.01 ADCC. When a high-energy channel of the amplifier is connected to the digitizer, the measured noise remained virtually unchanged, while the noise added by a low-energy channel was estimated to be 0.38 $\pm$ 0.02 ADCC (46 $\pm$ 2$μ$V). A test facility is under construction to study saturation, mitigate noise and measure the performance of the LZ electronics and data acquisition chain.
△ Less
Submitted 24 November, 2015;
originally announced November 2015.