-
Conceptualization of ionization dose to water to quantify radiotherapy doses
Authors:
Nobuyuki Kanematsu
Abstract:
\emph{Objective.} This study conceptualizes the ionization dose to water as the dose absorbed to water and expended exclusively on ionization, which may be more relevant to biological responses than absorbed dose, and formulates its dosimetric procedures for high-energy photon, electron, proton, and ion beams. It also aims to propose ionization chambers with reduced ionization-dose uncertainty for…
▽ More
\emph{Objective.} This study conceptualizes the ionization dose to water as the dose absorbed to water and expended exclusively on ionization, which may be more relevant to biological responses than absorbed dose, and formulates its dosimetric procedures for high-energy photon, electron, proton, and ion beams. It also aims to propose ionization chambers with reduced ionization-dose uncertainty for proton and ion beams. \emph{Approach.} Based on the international code of practice, the dosimetric procedure without W-value correction was formulated for all these beam types, and that also without stopping-power-ratio correction was formulated for proton and ion beams. For the latter, water-equivalent gas (WEG) was considered for gas-sealed ionization chambers. For dose representation, the ionization dose is calibrated to the reference absorbed dose in the standard dosimeter calibration with $^{60}$Co γ rays. The proposed dosimetry procedures were simulated for virtual test beams. \emph{Main results.} The calibrated ionization dose measured with a common ionization chamber was compatible with the absorbed dose for all beams, and with a slightly reduced uncertainty from \SI{1.4}{\%} to \SI{1.3}{\%} for proton beams and from \SI{2.4}{\%} to \SI{1.9}{\%} for ion beams. With a WEG ionization chamber, the uncertainty was further reduced to \SI{0.7}{\%} for proton beams and \SI{1.0}{\%} for ion beams. \emph{Significance.} The new dose concept, calibrated ionization dose, can be easily used in radiotherapy practice with conventional dose prescriptions. The minimized beam-quality correction for ionization doses will be advantageous for non-reference conditions and complex clinical beams of various types, including those not covered by the standard dosimetry procedures.
△ Less
Submitted 9 May, 2025; v1 submitted 29 October, 2024;
originally announced October 2024.
-
Manuscript preparation guide for Radiological Physics and Technology
Authors:
Nobuyuki Kanematsu
Abstract:
This guide is intended for authors who wish to publish an original paper in Radiological Physics and Technology. They should follow the submission guidelines of the journal as well as standard guidelines and conventions for scientific writing. The journal recommends a standard structure for the main text and requires an additional section for declarations. Each section has a numbered heading that…
▽ More
This guide is intended for authors who wish to publish an original paper in Radiological Physics and Technology. They should follow the submission guidelines of the journal as well as standard guidelines and conventions for scientific writing. The journal recommends a standard structure for the main text and requires an additional section for declarations. Each section has a numbered heading that announces the topic of its content. The text may consist of paragraphs for subtopics. Original content should be detailed while unoriginal content available elsewhere should be minimized and distinguished by reference citation. Quantities and equations should be presented according to academic conventions. Tables and figures should only be used to present essential information clearly and efficiently. The LaTeX source files of this guide are available online and may be used as a manuscript template. A checklist is also provided for submitting authors.
△ Less
Submitted 23 April, 2024; v1 submitted 5 March, 2024;
originally announced March 2024.
-
Technical Note: Reconstruction of physical and biological dose distributions of carbon-ion beam through deconvolution of longitudinal dosimeter responses
Authors:
Nobuyuki Kanematsu,
Taku Inaniwa,
Shunsuke Yonai,
Hideyuki Mizuno
Abstract:
Purpose: This is a theoretical simulation study for proof of concept of radiochromic film dosimetry to measure physical and biological doses without plan-based quenching correction for patient-specific quality assurance of carbon-ion radiotherapy. Methods: We took a layer-stacking carbon-ion beam comprised of range-shifted beamlets. The dosimeter response was simulated according to an experimental…
▽ More
Purpose: This is a theoretical simulation study for proof of concept of radiochromic film dosimetry to measure physical and biological doses without plan-based quenching correction for patient-specific quality assurance of carbon-ion radiotherapy. Methods: We took a layer-stacking carbon-ion beam comprised of range-shifted beamlets. The dosimeter response was simulated according to an experimental quenching model. The beam model followed a treatment planning system. The beam was decomposed into finely arranged beamlets with weights estimated by deconvolution of longitudinal dosimeter responses. The distributions of physical and biological doses were reconstructed from the estimated weights, and were compared with the plan. We also evaluated the sensitivity to measurement errors and to erratic delivery with an undelivered beamlet. Results: The reconstructed physical and biological doses accurately reproduced the simulated delivery with errors approximately corresponding to the measurement errors. The erratic beam delivery was easily detectable by comparison of biological dose distribution to the plan. Conclusions: We have developed a method to measure physical and biological doses by longitudinal dosimetry of quenched response without using plan data. The method only involves a general optimization algorithm, a radiobiology model, and experimental beamlet data, and requires no extra corrections. Theoretically, this approach is applicable to various dosimeters and to proton and ion beams of any delivery method, regardless of quenching or biological effectiveness.
△ Less
Submitted 27 September, 2018;
originally announced September 2018.
-
Estimation of linear energy transfer distribution for broad-beam carbon-ion radiotherapy at the National Institute of Radiological Sciences, Japan
Authors:
Nobuyuki Kanematsu,
Naruhiro Matsufuji,
Taku Inaniwa
Abstract:
Carbon-ion radiotherapy (CIRT) is generally evaluated with the dose weighted by relative biological effectiveness (RBE), while the radiation quality varying in the body of each patient is ignored for lack of such distribution. In this study, we attempted to develop a method to estimate linear energy transfer (LET) for a treatment planning system that only handled physical and RBE-weighted doses. T…
▽ More
Carbon-ion radiotherapy (CIRT) is generally evaluated with the dose weighted by relative biological effectiveness (RBE), while the radiation quality varying in the body of each patient is ignored for lack of such distribution. In this study, we attempted to develop a method to estimate linear energy transfer (LET) for a treatment planning system that only handled physical and RBE-weighted doses. The LET taken from a database of clinical broad beams was related to the RBE per energy with two polyline fitting functions for spread-out Bragg peak (SOBP) and for entrance depths, which would be selected by RBE threshold per energy per modulation. The LET estimation was consistent with the original calculation typically within a few keV/μm except for the overkill at the distal end of SOBP. The CIRT treatments can thus be related to the knowledge obtained in radiobiology experiments that used LET to represent radiation quality.
△ Less
Submitted 31 October, 2017;
originally announced October 2017.
-
Biological dose representation for carbon-ion radiotherapy of unconventional fractionation
Authors:
Nobuyuki Kanematsu,
Taku Inaniwa
Abstract:
In carbon-ion radiotherapy, single-beam delivery each day in alternate directions has been commonly practiced for operational efficiency, taking advantage of the Bragg peak and the relative biological effectiveness (RBE) for uniform dose conformation to a tumor. The treatment plans are usually evaluated with total RBE-weighted dose, which is however deficient in relevance to the biological effect…
▽ More
In carbon-ion radiotherapy, single-beam delivery each day in alternate directions has been commonly practiced for operational efficiency, taking advantage of the Bragg peak and the relative biological effectiveness (RBE) for uniform dose conformation to a tumor. The treatment plans are usually evaluated with total RBE-weighted dose, which is however deficient in relevance to the biological effect in the linear-quadratic model due to its quadratic-dose term, or the dose-fractionation effect. In this study, we reformulate the extrapolated response dose (ERD), or synonymously BED, which normalizes the dose-fractionation and cell-repopulation effects as well as the RBE of treating radiation, based on inactivation of a single model cell system and a typical treating radiation in carbon-ion RT. The ERD distribution virtually represents the biological effect of the treatment regardless of radiation modality or fractionation scheme. We applied the ERD formulation to simplistic model treatments and to a preclinical survey for hypofractionation based on an actual prostate-cancer treatment of carbon-ion radiotherapy. The proposed formulation was demonstrated to be practical and to offer theoretical implications. In the prostate-cancer case, the ERD distribution was very similar to the RBE-weighted-dose distribution of the actual treatment in 12 fractions. With hypofractionation, while the RBE-weighted-dose distribution varied significantly, the ERD distribution was nearly invariant, implying that the carbon-ion radiotherapy would be insensitive to fractionation. However, treatment evaluation with simplistic biological dose is intrinsically limited and must be complemented in practice somehow by clinical experiences and biology experiments.
△ Less
Submitted 4 July, 2016;
originally announced July 2016.
-
Relationship between mass density, electron density, and elemental composition of body tissues for Monte Carlo simulation in radiation treatment planning
Authors:
Nobuyuki Kanematsu
Abstract:
Purpose: For Monte Carlo simulation of radiotherapy, x-ray CT number of every system needs to be calibrated and converted to mass density and elemental composition. This study aims to formulate material properties of body tissues for practical two-step conversion from CT number. Methods: We used the latest compilation on body tissues that constitute reference adult male and female. We formulated t…
▽ More
Purpose: For Monte Carlo simulation of radiotherapy, x-ray CT number of every system needs to be calibrated and converted to mass density and elemental composition. This study aims to formulate material properties of body tissues for practical two-step conversion from CT number. Methods: We used the latest compilation on body tissues that constitute reference adult male and female. We formulated the relations among mass, electron, and elemental densities into polylines to connect representative tissues, for which we took mass-weighted mean for the tissues in limited density regions. We compared the polyline functions of mass density with a bi-line for electron density and broken lines for elemental densities, which were derived from preceding studies. Results: There was generally high correlation between mass density and the other densities except of C, N, and O for light spongiosa tissues occupying 1% of body mass. The polylines fitted to the dominant tissues and were generally consistent with the bi-line and the broken lines. Conclusions: We have formulated the invariant relations between mass and electron densities and from mass to elemental densities for body tissues. The formulation enables Monte Carlo simulation in treatment planning practice without additional burden with CT-number calibration.
△ Less
Submitted 2 August, 2015;
originally announced August 2015.
-
Influence of nuclear interactions in polyethylene range compensators for carbon-ion radiotherapy
Authors:
Nobuyuki Kanematsu,
Yusuke Koba,
Risa Ogata,
Takeshi Himukai
Abstract:
\item[Purpose] A recent study revealed that polyethylene (PE) would cause extra carbon-ion attenuation per range shift by 0.45\%/cm due to compositional differences in nuclear interactions. The present study aims to assess the influence of PE range compensators on tumor dose in carbon-ion radiotherapy. \item[Methods] Carbon-ion radiation was modeled to be composed of primary carbon ions and second…
▽ More
\item[Purpose] A recent study revealed that polyethylene (PE) would cause extra carbon-ion attenuation per range shift by 0.45\%/cm due to compositional differences in nuclear interactions. The present study aims to assess the influence of PE range compensators on tumor dose in carbon-ion radiotherapy. \item[Methods] Carbon-ion radiation was modeled to be composed of primary carbon ions and secondary particles, for each of which the dose and the relative biological effectiveness (RBE) were estimated at a tumor depth in the middle of spread-out Bragg peak. Assuming exponential behavior for attenuation and yield of these components with depth, the PE effect on dose was calculated for clinical carbon-ion beams and was partly tested by experiment. The two-component model was integrated into a treatment-planning system and the PE effect was estimated in two clinical cases. \item[Results] The attenuation per range shift by PE was 0.1\%--0.3\%/cm in dose and 0.2\%--0.4\%/cm in RBE-weighted dose, depending on energy and range-modulation width. This translates into reduction of RBE-weighted dose by up to 3\% in extreme cases. In the treatment-planning study, however, the effect on RBE-weighted dose to tumor was typically within 1\% reduction. \item[Conclusions] The extra attenuation of primary carbon ions in PE was partly compensated by increased secondary particles for tumor dose. In practical situations, the PE range compensators would normally cause only marginal errors as compared to intrinsic uncertainties in treatment planning, patient setup, beam delivery, and clinical response.
△ Less
Submitted 30 September, 2016; v1 submitted 17 July, 2013;
originally announced July 2013.
-
Evaluation of plastic materials for range shifting, range compensation, and solid-phantom dosimetry in carbon-ion radiotherapy
Authors:
Nobuyuki Kanematsu,
Yusuke Koba,
Risa Ogata
Abstract:
Purpose: Beam range control is the essence of radiotherapy with heavy charged particles. In conventional broad-beam delivery, fine range adjustment is achieved by insertion of range shifting and compensating materials. In dosimetry, solid phantoms are often used for convenience. These materials should ideally be equivalent to water. In this study, we evaluated dosimetric water equivalence of four…
▽ More
Purpose: Beam range control is the essence of radiotherapy with heavy charged particles. In conventional broad-beam delivery, fine range adjustment is achieved by insertion of range shifting and compensating materials. In dosimetry, solid phantoms are often used for convenience. These materials should ideally be equivalent to water. In this study, we evaluated dosimetric water equivalence of four common plastics, HDPE, PMMA, PET, and POM.
Methods: Using the Bethe formula for energy loss, the Gottschalk formula for multiple scattering, and the Sihver formula for nuclear interactions, we calculated the effective densities of the plastics for these interactions. We experimentally measured variation of the Bragg peak of carbon-ion beams by insertion of HDPE, PMMA, and POM, which were compared with analytical model calculations.
Results: The theoretical calculation resulted in slightly reduced multiple scattering and severely increased nuclear interactions for HDPE, compared to water and the other plastics. The increase in attenuation of carbon ions for 20-cm range shift was experimentally measured to be 8.9\% for HDPE, 2.5\% for PMMA, and 0.0\% for POM while PET was theoretically estimated to be in between PMMA and POM. The agreement between the measurements and the calculations was about 1\% or better.
Conclusions: For carbon-ion beams, POM was dosimetrically indistinguishable from water and the best of the plastics examined in this study. The poorest was HDPE, which would reduce the Bragg peak by 0.45\% per 1-cm range shift, although with marginal superiority for reduced multiple scattering. Between the two clear plastics, PET would be superior to PMMA in dosimetric water equivalence.
△ Less
Submitted 30 September, 2016; v1 submitted 4 November, 2012;
originally announced November 2012.
-
Relationship between electron density and effective densities of body tissues for stopping, scattering, and nuclear interaction of proton and ion beams
Authors:
Nobuyuki Kanematsu,
Taku Inaniwa,
Yusuke Koba
Abstract:
Purpose: In treatment planning of charged-particle radiotherapy, patient heterogeneity is conventionally modeled as variable-density water converted from CT images to best reproduce the stopping power, which may lead to inaccuracies in the handling of multiple scattering and nuclear interactions. Although similar conversions can be defined for these individual interactions, they would be valid onl…
▽ More
Purpose: In treatment planning of charged-particle radiotherapy, patient heterogeneity is conventionally modeled as variable-density water converted from CT images to best reproduce the stopping power, which may lead to inaccuracies in the handling of multiple scattering and nuclear interactions. Although similar conversions can be defined for these individual interactions, they would be valid only for specific CT systems and would require additional tasks for clinical application. This study aims to improve the practicality of the interaction-specific heterogeneity correction. Methods: We calculated the electron densities and effective densities for stopping power, multiple scattering, and nuclear interactions of protons and ions, using the standard elemental-composition data for body tissues to construct the invariant conversion functions. We also simulated a proton beam in a lung-like geometry and a carbon-ion beam in a prostate-like geometry to demonstrate the procedure and the effects of the interaction-specific heterogeneity correction. Results: Strong correlations were observed between the electron density and the respective effective densities, with which we formulated polyline conversion functions. Their effects amounted to 10% differences in multiple-scattering angle and nuclear-interaction mean free path for bones compared to those in the conventional heterogeneity correction. Although their realistic effect on patient dose distributions would be generally small, it could be at the level of a few percent when a beam traverses a large bone. Conclusions: The present conversion functions are invariant and may be incorporated in treatment planning systems with a common function relating CT number to electron density. This will enable improved beam dose calculation while minimizing initial setup and quality management of the user's specific system.
△ Less
Submitted 15 November, 2012; v1 submitted 29 June, 2011;
originally announced June 2011.
-
Robust dual-field optimization of scanned ion beams against range and setup uncertainties
Authors:
Taku Inaniwa,
Nobuyuki Kanematsu,
Takuji Furukawa,
Koji Noda
Abstract:
A 'dual-field' strategy is often used for tumors with highly complex shapes and/or with large volumes exceeding available field-size in both passive and scanning irradiations with ion beams. Range and setup uncertainties can cause hot and cold doses at the field junction within the target. Such uncertainties will also cause cold doses in the peripheral region of the target. We have developed an al…
▽ More
A 'dual-field' strategy is often used for tumors with highly complex shapes and/or with large volumes exceeding available field-size in both passive and scanning irradiations with ion beams. Range and setup uncertainties can cause hot and cold doses at the field junction within the target. Such uncertainties will also cause cold doses in the peripheral region of the target. We have developed an algorithm to reduce the sensitivity of the dual-field plan to these uncertainties in scanning irradiations. This algorithm is composed of the following two steps: 1) generating the expanded target volume, and 2) solving the inverse problem where the terms suppressing the dose gradient of individual fields are added into the objective function. The validity of this algorithm is demonstrated through the simulation studies for three extreme cases of two fields with unidirectional, opposing and orthogonal geometries. With the proposed algorithm, we can obtain a more robust plan to minimize the effects of range and setup uncertainties than the conventional plan. Compared to that for the conventional plan, the optimization time for the robust plan increased by a factor of approximately three.
△ Less
Submitted 5 October, 2010;
originally announced October 2010.
-
Modeling of beam customization devices in the pencil beam splitting algorithm for heavy charged particle radiotherapy
Authors:
Nobuyuki Kanematsu
Abstract:
A broad-beam-delivery system for heavy-charged-particle radiotherapy often employs multiple collimators and a range-compensating filter, which potentially offer complex beam customization. In treatment planning, it is however difficult for a conventional pencil-beam algorithm to deal with these structures due to beam-size growth during transport. This study aims to resolve the problem with a novel…
▽ More
A broad-beam-delivery system for heavy-charged-particle radiotherapy often employs multiple collimators and a range-compensating filter, which potentially offer complex beam customization. In treatment planning, it is however difficult for a conventional pencil-beam algorithm to deal with these structures due to beam-size growth during transport. This study aims to resolve the problem with a novel computational model. The pencil beams are initially defined at the range compensating filter with angular-acceptance correction for the upstream collimators followed by the range compensation effects. They are individually transported with possible splitting near the downstream collimator edges to deal with its fine structure. The dose distribution for a carbon-ion beam was calculated and compared with existing experimental data. The penumbra sizes of various collimator edges agreed between them to a submillimeter level. This beam-customization model will complete an accurate and efficient dose-calculation algorithm for treatment planning with heavy charged particles.
△ Less
Submitted 6 December, 2010; v1 submitted 10 September, 2010;
originally announced September 2010.
-
Dose calculation algorithm of fast fine-heterogeneity correction for heavy charged particle radiotherapy
Authors:
Nobuyuki Kanematsu
Abstract:
This work addresses computing techniques for dose calculations in treatment planning with proton and ion beams, based on an efficient kernel-convolution method referred to as grid-dose spreading (GDS) and accurate heterogeneity-correction method referred to as Gaussian beam splitting. The original GDS algorithm suffered from distortion of dose distribution for beams tilted with respect to the dose…
▽ More
This work addresses computing techniques for dose calculations in treatment planning with proton and ion beams, based on an efficient kernel-convolution method referred to as grid-dose spreading (GDS) and accurate heterogeneity-correction method referred to as Gaussian beam splitting. The original GDS algorithm suffered from distortion of dose distribution for beams tilted with respect to the dose-grid axes. Use of intermediate grids normal to the beam field has solved the beam-tilting distortion. Interplay of arrangement between beams and grids was found as another intrinsic source of artifact. Inclusion of rectangular-kernel convolution in beam transport, to share the beam contribution among the nearest grids in a regulatory manner, has solved the interplay problem. This algorithmic framework was applied to a tilted proton pencil beam and a broad carbon-ion beam. In these cases, while the elementary pencil beams individually split into several tens, the calculation time increased only by several times with the GDS algorithm. The GDS and beam-splitting methods will complementarily enable accurate and efficient dose calculations for radiotherapy with protons and ions.
△ Less
Submitted 16 June, 2010; v1 submitted 15 May, 2009;
originally announced May 2009.
-
Dynamic splitting of Gaussian pencil beams in heterogeneity-correction algorithms for radiotherapy with heavy charged particles
Authors:
Nobuyuki Kanematsu,
Masataka Komori,
Shunsuke Yonai,
Azusa Ishizaki
Abstract:
The pencil-beam model is valid only when elementary Gaussian beams are small enough with respect to lateral heterogeneity of a medium, which is not always the case in heavy charged particle radiotherapy. This work addresses a solution for this problem by applying our discovery of self-similar nature of Gaussian distributions. In this method, Gaussian beams split into narrower and deflecting daug…
▽ More
The pencil-beam model is valid only when elementary Gaussian beams are small enough with respect to lateral heterogeneity of a medium, which is not always the case in heavy charged particle radiotherapy. This work addresses a solution for this problem by applying our discovery of self-similar nature of Gaussian distributions. In this method, Gaussian beams split into narrower and deflecting daughter beams when their size has exceeded the lateral heterogeneity limit. They will be automatically arranged with modulated areal density for accurate and efficient dose calculations. The effectiveness was assessed in an carbon-ion beam experiment in presence of steep range compensation, where the splitting calculation reproduced the detour effect of imperfect compensation amounting up to about 10% or as large as the lateral particle disequilibrium effect. The efficiency was analyzed in calculations for carbon-ion and proton radiations with a heterogeneous phantom model, where the splitting calculations took about a minute and were factor of 5 slower than the non-splitting ones. The beam-splitting method is reasonably accurate, efficient, and general so that it can be potentially used in various pencil-beam algorithms.
△ Less
Submitted 21 December, 2008;
originally announced December 2008.
-
Semi-empirical formulation of multiple scattering for Gaussian beam model of heavy charged particles stopping in tissue-like matter
Authors:
Nobuyuki Kanematsu
Abstract:
Dose calculation for radiotherapy with protons and heavier ions deals with a large volume of path integrals involving a scattering power of body tissue. This work provides a simple model for such demanding applications. There is an approximate linearity between RMS end-point displacement and range of incident particles in water, empirically found in measurements and detailed calculations. This f…
▽ More
Dose calculation for radiotherapy with protons and heavier ions deals with a large volume of path integrals involving a scattering power of body tissue. This work provides a simple model for such demanding applications. There is an approximate linearity between RMS end-point displacement and range of incident particles in water, empirically found in measurements and detailed calculations. This fact was translated into a simple linear formula, from which the scattering power that is only inversely proportional to residual range was derived. The simplicity enabled analytical formulation for ions stopping in water, which was designed to be equivalent with the extended Highland model and agreed with measurements within 2% or 0.02 cm in RMS displacement. The simplicity will also improve the efficiency of numerical path integrals in the presence of heterogeneity.
△ Less
Submitted 13 December, 2008; v1 submitted 8 October, 2008;
originally announced October 2008.
-
Alternative scattering power for Gaussian beam model of heavy charged particles
Authors:
Nobuyuki Kanematsu
Abstract:
This study provides an accurate, efficient, and simple multiple scattering formulation for heavy charged particles such as protons and heavier ions with a new form of scattering power that is a key quantity for beam transport in matter. The Highland formula for multiple scattering angle was modified to a scattering-power formula to be used within the Fermi-Eyges theory in the presence of heterog…
▽ More
This study provides an accurate, efficient, and simple multiple scattering formulation for heavy charged particles such as protons and heavier ions with a new form of scattering power that is a key quantity for beam transport in matter. The Highland formula for multiple scattering angle was modified to a scattering-power formula to be used within the Fermi-Eyges theory in the presence of heterogeneity. An analytical formula for RMS end-point displacement in homogeneous matter was also derived for arbitrary ions. The formulation was examined in terms of RMS angles and displacements in comparison with other formulations and measurements. The results for protons, helium ions, and carbon ions in water agreed with them at a level of 2% or the differences were discussed.
△ Less
Submitted 8 October, 2008; v1 submitted 31 May, 2008;
originally announced June 2008.
-
Computational modeling of beam-customization devices for heavy-charged-particle radiotherapy
Authors:
Nobuyuki Kanematsu,
Shunsuke Yonai,
Azusa Ishizaki,
Masami Torikoshi
Abstract:
A model for beam customization with collimators and a range-compensating filter based on the phase-space theory for beam transport is presented for dose distribution calculation in treatment planning of radiotherapy with protons and heavier ions. Independent handling of pencil beams in conventional pencil-beam algorithms causes unphysical collimator-height dependence in the middle of large field…
▽ More
A model for beam customization with collimators and a range-compensating filter based on the phase-space theory for beam transport is presented for dose distribution calculation in treatment planning of radiotherapy with protons and heavier ions. Independent handling of pencil beams in conventional pencil-beam algorithms causes unphysical collimator-height dependence in the middle of large fields, which is resolved by the framework comprised of generation, transport, collimation, regeneration, range-compensation, and edge-sharpening processes with a matrix of pencil beams. The model was verified to be consistent with measurement and analytic estimation at a submillimeter level in penumbra of individual collimators with a combinational-collimated carbon-ion beam. The model computation is fast, accurate, and readily applicable to pencil-beam algorithms in treatment planning with capability of combinational collimation to make best use of the beam-customization devices.
△ Less
Submitted 16 April, 2008; v1 submitted 26 November, 2007;
originally announced November 2007.
-
The grid-dose-spreading algorithm for dose distribution calculation in heavy charged particle radiotherapy
Authors:
Nobuyuki Kanematsu,
Shunsuke Yonai,
Azusa Ishizaki
Abstract:
A new variant of the pencil-beam (PB) algorithm for dose distribution calculation for radiotherapy with protons and heavier ions, the grid-dose spreading (GDS) algorithm, is proposed. The GDS algorithm is intrinsically faster than conventional PB algorithms due to approximations in convolution integral, where physical calculations are decoupled from simple grid-to-grid energy transfer. It was ef…
▽ More
A new variant of the pencil-beam (PB) algorithm for dose distribution calculation for radiotherapy with protons and heavier ions, the grid-dose spreading (GDS) algorithm, is proposed. The GDS algorithm is intrinsically faster than conventional PB algorithms due to approximations in convolution integral, where physical calculations are decoupled from simple grid-to-grid energy transfer. It was effortlessly implemented to a carbon-ion radiotherapy treatment planning system to enable realistic beam blurring in the field, which was absent with the broad-beam (BB) algorithm. For a typical prostate treatment, the slowing factor of the GDS algorithm relative to the BB algorithm was 1.4, which is a great improvement over the conventional PB algorithms with a typical slowing factor of several tens. The GDS algorithm is mathematically equivalent to the PB algorithm for horizontal and vertical coplanar beams commonly used in carbon-ion radiotherapy while dose deformation within the size of the pristine spread occurs for angled beams, which was within 3 mm for a single proton pencil beam of $30^\circ$ incidence, and needs to be assessed against the clinical requirements and tolerances in practical situations.
△ Less
Submitted 26 November, 2007; v1 submitted 27 July, 2007;
originally announced July 2007.
-
Measurements of total and partial charge-changing cross sections for 200-400 MeV/nucleon 12C in water and polycarbonate
Authors:
T. Toshito,
K. Kodama,
L. Sihver,
K. Yusa,
M. Ozaki,
K. Amako,
S. Kameoka,
K. Murakami,
T. Sasaki,
S. Aoki,
T. Ban,
T. Fukuda,
M. Komatsu,
H. Kubota,
N. Naganawa,
T. Nakamura,
T. Nakano,
M. Natsume,
K. Niwa,
S. Takahashi,
J. Yoshida,
H. Yoshida,
M. Kanazawa,
N. Kanematsu,
M. Komori
, et al. (7 additional authors not shown)
Abstract:
We have studied charged nuclear fragments produced by 200 - 400 MeV/nucleon carbon ions, interacting with water and polycarbonate, using a newly developed emulsion detector. Total and partial charge-changing cross sections for the production of B, Be, and Li fragments were measured and compared with both previously published measurements, and model predictions. This study is of importance for va…
▽ More
We have studied charged nuclear fragments produced by 200 - 400 MeV/nucleon carbon ions, interacting with water and polycarbonate, using a newly developed emulsion detector. Total and partial charge-changing cross sections for the production of B, Be, and Li fragments were measured and compared with both previously published measurements, and model predictions. This study is of importance for validating and improving carbon ion therapy treatment planning systems, and for estimating the radiological risks for personnel on space missions, since carbon is a significant component of the Galactic Cosmic Rays.
△ Less
Submitted 27 March, 2007;
originally announced March 2007.
-
A straw drift chamber spectrometer for studies of rare kaon decays
Authors:
K. Lang,
D. Ambrose,
C. Arroyo,
M. Bachman,
D. Connor,
M. Eckhause,
K. M. Ecklund,
S. Graessle,
M. Hamela,
S. Hamilton,
A. D. Hancock,
K. Hartman,
M. Hebert,
C. H. Hoff,
G. W. Hoffmann,
G. M. Irwin,
J. R. Kane,
N. Kanematsu,
Y. Kuang,
R. Lee,
M. Marcin,
R. D. Martin,
J. McDonough,
A. Milder,
W. R. Molzon
, et al. (11 additional authors not shown)
Abstract:
We describe the design, construction, readout, tests, and performance of planar drift chambers, based on 5 mm diameter copperized Mylar and Kapton straws, used in an experimental search for rare kaon decays. The experiment took place in the high-intensity neutral beam at the Alternating Gradient Synchrotron of Brookhaven National Laboratory, using a neutral beam stop, two analyzing dipoles, and…
▽ More
We describe the design, construction, readout, tests, and performance of planar drift chambers, based on 5 mm diameter copperized Mylar and Kapton straws, used in an experimental search for rare kaon decays. The experiment took place in the high-intensity neutral beam at the Alternating Gradient Synchrotron of Brookhaven National Laboratory, using a neutral beam stop, two analyzing dipoles, and redundant particle identification to remove backgrounds.
△ Less
Submitted 12 August, 2003;
originally announced August 2003.
-
First Observation of the Rare Decay Mode K-long -> e+ e-
Authors:
BNL E871 Collaboration,
D. Ambrose,
C. Arroyo,
M. Bachman,
P. de Cecco,
D. Connor,
M. Eckhause,
K. M. Ecklund,
S. Graessle,
A. D. Hancock,
K. Hartman,
M. Hebert,
C. H. Hoff,
G. W. Hoffmann,
G. M. Irwin,
J. R. Kane,
N. Kanematsu,
Y. Kuang,
K. Lang,
R. Lee,
R. D. Martin,
J. McDonough,
A. Milder,
W. R. Molzon,
M. Pommot-Maia
, et al. (9 additional authors not shown)
Abstract:
In an experiment designed to search for and study very rare two-body decay modes of the K-long, we have observed four examples of the decay K-long -> e+ e-, where the expected background is 0.17+-0.10 events. This observation translates into a branching fraction of 8.7^{+5.7}_{-4.1} X 10^{-12}, consistent with recent theoretical predictions. This result represents by far the smallest branching f…
▽ More
In an experiment designed to search for and study very rare two-body decay modes of the K-long, we have observed four examples of the decay K-long -> e+ e-, where the expected background is 0.17+-0.10 events. This observation translates into a branching fraction of 8.7^{+5.7}_{-4.1} X 10^{-12}, consistent with recent theoretical predictions. This result represents by far the smallest branching fraction yet measured in particle physics.
△ Less
Submitted 1 October, 1998;
originally announced October 1998.