Skip to main content

Showing 1–20 of 20 results for author: Kanematsu, N

.
  1. arXiv:2410.21948  [pdf, ps, other

    physics.med-ph

    Conceptualization of ionization dose to water to quantify radiotherapy doses

    Authors: Nobuyuki Kanematsu

    Abstract: \emph{Objective.} This study conceptualizes the ionization dose to water as the dose absorbed to water and expended exclusively on ionization, which may be more relevant to biological responses than absorbed dose, and formulates its dosimetric procedures for high-energy photon, electron, proton, and ion beams. It also aims to propose ionization chambers with reduced ionization-dose uncertainty for… ▽ More

    Submitted 9 May, 2025; v1 submitted 29 October, 2024; originally announced October 2024.

    Comments: 11 pages, 3 tables, 0 figures

  2. arXiv:2403.02888  [pdf, ps, other

    physics.med-ph

    Manuscript preparation guide for Radiological Physics and Technology

    Authors: Nobuyuki Kanematsu

    Abstract: This guide is intended for authors who wish to publish an original paper in Radiological Physics and Technology. They should follow the submission guidelines of the journal as well as standard guidelines and conventions for scientific writing. The journal recommends a standard structure for the main text and requires an additional section for declarations. Each section has a numbered heading that… ▽ More

    Submitted 23 April, 2024; v1 submitted 5 March, 2024; originally announced March 2024.

    Comments: 8 pages, 1 figure, 4 tables

  3. arXiv:1809.10358  [pdf, ps, other

    physics.med-ph

    Technical Note: Reconstruction of physical and biological dose distributions of carbon-ion beam through deconvolution of longitudinal dosimeter responses

    Authors: Nobuyuki Kanematsu, Taku Inaniwa, Shunsuke Yonai, Hideyuki Mizuno

    Abstract: Purpose: This is a theoretical simulation study for proof of concept of radiochromic film dosimetry to measure physical and biological doses without plan-based quenching correction for patient-specific quality assurance of carbon-ion radiotherapy. Methods: We took a layer-stacking carbon-ion beam comprised of range-shifted beamlets. The dosimeter response was simulated according to an experimental… ▽ More

    Submitted 27 September, 2018; originally announced September 2018.

    Journal ref: Kanematsu N, Inaniwa T, Yonai S, Mizuno H. Med. Phys. 2019;46:1478-1482

  4. Estimation of linear energy transfer distribution for broad-beam carbon-ion radiotherapy at the National Institute of Radiological Sciences, Japan

    Authors: Nobuyuki Kanematsu, Naruhiro Matsufuji, Taku Inaniwa

    Abstract: Carbon-ion radiotherapy (CIRT) is generally evaluated with the dose weighted by relative biological effectiveness (RBE), while the radiation quality varying in the body of each patient is ignored for lack of such distribution. In this study, we attempted to develop a method to estimate linear energy transfer (LET) for a treatment planning system that only handled physical and RBE-weighted doses. T… ▽ More

    Submitted 31 October, 2017; originally announced October 2017.

    Comments: 6 pages, 2 tables, 5 figures

    Journal ref: Radiological Physics and Technology 11(2) 242-247, 2018

  5. Biological dose representation for carbon-ion radiotherapy of unconventional fractionation

    Authors: Nobuyuki Kanematsu, Taku Inaniwa

    Abstract: In carbon-ion radiotherapy, single-beam delivery each day in alternate directions has been commonly practiced for operational efficiency, taking advantage of the Bragg peak and the relative biological effectiveness (RBE) for uniform dose conformation to a tumor. The treatment plans are usually evaluated with total RBE-weighted dose, which is however deficient in relevance to the biological effect… ▽ More

    Submitted 4 July, 2016; originally announced July 2016.

    Journal ref: Phys. Med. Biol. 62 (2017) 1062-1075

  6. Relationship between mass density, electron density, and elemental composition of body tissues for Monte Carlo simulation in radiation treatment planning

    Authors: Nobuyuki Kanematsu

    Abstract: Purpose: For Monte Carlo simulation of radiotherapy, x-ray CT number of every system needs to be calibrated and converted to mass density and elemental composition. This study aims to formulate material properties of body tissues for practical two-step conversion from CT number. Methods: We used the latest compilation on body tissues that constitute reference adult male and female. We formulated t… ▽ More

    Submitted 2 August, 2015; originally announced August 2015.

    Comments: 4 pages, 3 figures

    MSC Class: 92C05

    Journal ref: Physics in Medicine and Biology 61(13) 5037-5050 (2016)

  7. arXiv:1307.4511  [pdf, ps, other

    physics.med-ph

    Influence of nuclear interactions in polyethylene range compensators for carbon-ion radiotherapy

    Authors: Nobuyuki Kanematsu, Yusuke Koba, Risa Ogata, Takeshi Himukai

    Abstract: \item[Purpose] A recent study revealed that polyethylene (PE) would cause extra carbon-ion attenuation per range shift by 0.45\%/cm due to compositional differences in nuclear interactions. The present study aims to assess the influence of PE range compensators on tumor dose in carbon-ion radiotherapy. \item[Methods] Carbon-ion radiation was modeled to be composed of primary carbon ions and second… ▽ More

    Submitted 30 September, 2016; v1 submitted 17 July, 2013; originally announced July 2013.

    Comments: Figures 4a, 4b, 5a, and 5b were converted from png to eps: % convert -compress LZW fig4a.png eps3:fig4a.eps

    Journal ref: Medical Physics 41(7) 071704 (2014)

  8. arXiv:1211.0697  [pdf, ps, other

    physics.med-ph

    Evaluation of plastic materials for range shifting, range compensation, and solid-phantom dosimetry in carbon-ion radiotherapy

    Authors: Nobuyuki Kanematsu, Yusuke Koba, Risa Ogata

    Abstract: Purpose: Beam range control is the essence of radiotherapy with heavy charged particles. In conventional broad-beam delivery, fine range adjustment is achieved by insertion of range shifting and compensating materials. In dosimetry, solid phantoms are often used for convenience. These materials should ideally be equivalent to water. In this study, we evaluated dosimetric water equivalence of four… ▽ More

    Submitted 30 September, 2016; v1 submitted 4 November, 2012; originally announced November 2012.

    Journal ref: Medical Physics 40(4) 041724 (2013)

  9. Relationship between electron density and effective densities of body tissues for stopping, scattering, and nuclear interaction of proton and ion beams

    Authors: Nobuyuki Kanematsu, Taku Inaniwa, Yusuke Koba

    Abstract: Purpose: In treatment planning of charged-particle radiotherapy, patient heterogeneity is conventionally modeled as variable-density water converted from CT images to best reproduce the stopping power, which may lead to inaccuracies in the handling of multiple scattering and nuclear interactions. Although similar conversions can be defined for these individual interactions, they would be valid onl… ▽ More

    Submitted 15 November, 2012; v1 submitted 29 June, 2011; originally announced June 2011.

    Comments: This version includes corrections to be published in Medical Physics as an erratum

    Journal ref: Medical Physics 39(2) 1016-1020 (2012), 40(1) 017202 (2013)

  10. arXiv:1010.0808  [pdf

    physics.med-ph

    Robust dual-field optimization of scanned ion beams against range and setup uncertainties

    Authors: Taku Inaniwa, Nobuyuki Kanematsu, Takuji Furukawa, Koji Noda

    Abstract: A 'dual-field' strategy is often used for tumors with highly complex shapes and/or with large volumes exceeding available field-size in both passive and scanning irradiations with ion beams. Range and setup uncertainties can cause hot and cold doses at the field junction within the target. Such uncertainties will also cause cold doses in the peripheral region of the target. We have developed an al… ▽ More

    Submitted 5 October, 2010; originally announced October 2010.

  11. Modeling of beam customization devices in the pencil beam splitting algorithm for heavy charged particle radiotherapy

    Authors: Nobuyuki Kanematsu

    Abstract: A broad-beam-delivery system for heavy-charged-particle radiotherapy often employs multiple collimators and a range-compensating filter, which potentially offer complex beam customization. In treatment planning, it is however difficult for a conventional pencil-beam algorithm to deal with these structures due to beam-size growth during transport. This study aims to resolve the problem with a novel… ▽ More

    Submitted 6 December, 2010; v1 submitted 10 September, 2010; originally announced September 2010.

    Comments: 11 pages, 5 figures

    Journal ref: Physics in Medicine and Biology 51 1361-71, 2011

  12. Dose calculation algorithm of fast fine-heterogeneity correction for heavy charged particle radiotherapy

    Authors: Nobuyuki Kanematsu

    Abstract: This work addresses computing techniques for dose calculations in treatment planning with proton and ion beams, based on an efficient kernel-convolution method referred to as grid-dose spreading (GDS) and accurate heterogeneity-correction method referred to as Gaussian beam splitting. The original GDS algorithm suffered from distortion of dose distribution for beams tilted with respect to the dose… ▽ More

    Submitted 16 June, 2010; v1 submitted 15 May, 2009; originally announced May 2009.

    Journal ref: Physica Medica 27(2) 97-102, 2011

  13. Dynamic splitting of Gaussian pencil beams in heterogeneity-correction algorithms for radiotherapy with heavy charged particles

    Authors: Nobuyuki Kanematsu, Masataka Komori, Shunsuke Yonai, Azusa Ishizaki

    Abstract: The pencil-beam model is valid only when elementary Gaussian beams are small enough with respect to lateral heterogeneity of a medium, which is not always the case in heavy charged particle radiotherapy. This work addresses a solution for this problem by applying our discovery of self-similar nature of Gaussian distributions. In this method, Gaussian beams split into narrower and deflecting daug… ▽ More

    Submitted 21 December, 2008; originally announced December 2008.

    Comments: 13 pages, 8 figures, 3 tables

    Journal ref: Phys. Med. Biol. 54 (2009) 2015-2027.

  14. Semi-empirical formulation of multiple scattering for Gaussian beam model of heavy charged particles stopping in tissue-like matter

    Authors: Nobuyuki Kanematsu

    Abstract: Dose calculation for radiotherapy with protons and heavier ions deals with a large volume of path integrals involving a scattering power of body tissue. This work provides a simple model for such demanding applications. There is an approximate linearity between RMS end-point displacement and range of incident particles in water, empirically found in measurements and detailed calculations. This f… ▽ More

    Submitted 13 December, 2008; v1 submitted 8 October, 2008; originally announced October 2008.

    Comments: 6 pages, 3 figures, submitted to Physics in Medicine and Biology

    Journal ref: Phys. Med. Biol. 54 (2009) N67-N73

  15. Alternative scattering power for Gaussian beam model of heavy charged particles

    Authors: Nobuyuki Kanematsu

    Abstract: This study provides an accurate, efficient, and simple multiple scattering formulation for heavy charged particles such as protons and heavier ions with a new form of scattering power that is a key quantity for beam transport in matter. The Highland formula for multiple scattering angle was modified to a scattering-power formula to be used within the Fermi-Eyges theory in the presence of heterog… ▽ More

    Submitted 8 October, 2008; v1 submitted 31 May, 2008; originally announced June 2008.

    Comments: To be published in Nuclear Instruments and Methods in Physics Research Section B

    Journal ref: Nucl. Instrum. Methods B 266 (2008) 5056-5062

  16. Computational modeling of beam-customization devices for heavy-charged-particle radiotherapy

    Authors: Nobuyuki Kanematsu, Shunsuke Yonai, Azusa Ishizaki, Masami Torikoshi

    Abstract: A model for beam customization with collimators and a range-compensating filter based on the phase-space theory for beam transport is presented for dose distribution calculation in treatment planning of radiotherapy with protons and heavier ions. Independent handling of pencil beams in conventional pencil-beam algorithms causes unphysical collimator-height dependence in the middle of large field… ▽ More

    Submitted 16 April, 2008; v1 submitted 26 November, 2007; originally announced November 2007.

    Comments: 16 pages, 5 figures

    Report number: PMID: 18495975

    Journal ref: Phys Med Biol. 2008 May 21;53(12):3113-3127

  17. arXiv:0707.4144  [pdf, ps, other

    physics.med-ph

    The grid-dose-spreading algorithm for dose distribution calculation in heavy charged particle radiotherapy

    Authors: Nobuyuki Kanematsu, Shunsuke Yonai, Azusa Ishizaki

    Abstract: A new variant of the pencil-beam (PB) algorithm for dose distribution calculation for radiotherapy with protons and heavier ions, the grid-dose spreading (GDS) algorithm, is proposed. The GDS algorithm is intrinsically faster than conventional PB algorithms due to approximations in convolution integral, where physical calculations are decoupled from simple grid-to-grid energy transfer. It was ef… ▽ More

    Submitted 26 November, 2007; v1 submitted 27 July, 2007; originally announced July 2007.

    Comments: 7 pages, 3 figures

    Journal ref: Medical Physics 35(2) 602-607, 2008

  18. Measurements of total and partial charge-changing cross sections for 200-400 MeV/nucleon 12C in water and polycarbonate

    Authors: T. Toshito, K. Kodama, L. Sihver, K. Yusa, M. Ozaki, K. Amako, S. Kameoka, K. Murakami, T. Sasaki, S. Aoki, T. Ban, T. Fukuda, M. Komatsu, H. Kubota, N. Naganawa, T. Nakamura, T. Nakano, M. Natsume, K. Niwa, S. Takahashi, J. Yoshida, H. Yoshida, M. Kanazawa, N. Kanematsu, M. Komori , et al. (7 additional authors not shown)

    Abstract: We have studied charged nuclear fragments produced by 200 - 400 MeV/nucleon carbon ions, interacting with water and polycarbonate, using a newly developed emulsion detector. Total and partial charge-changing cross sections for the production of B, Be, and Li fragments were measured and compared with both previously published measurements, and model predictions. This study is of importance for va… ▽ More

    Submitted 27 March, 2007; originally announced March 2007.

    Comments: 28 pages, 13 figures

    Journal ref: Phys.Rev.C75:054606,2007

  19. A straw drift chamber spectrometer for studies of rare kaon decays

    Authors: K. Lang, D. Ambrose, C. Arroyo, M. Bachman, D. Connor, M. Eckhause, K. M. Ecklund, S. Graessle, M. Hamela, S. Hamilton, A. D. Hancock, K. Hartman, M. Hebert, C. H. Hoff, G. W. Hoffmann, G. M. Irwin, J. R. Kane, N. Kanematsu, Y. Kuang, R. Lee, M. Marcin, R. D. Martin, J. McDonough, A. Milder, W. R. Molzon , et al. (11 additional authors not shown)

    Abstract: We describe the design, construction, readout, tests, and performance of planar drift chambers, based on 5 mm diameter copperized Mylar and Kapton straws, used in an experimental search for rare kaon decays. The experiment took place in the high-intensity neutral beam at the Alternating Gradient Synchrotron of Brookhaven National Laboratory, using a neutral beam stop, two analyzing dipoles, and… ▽ More

    Submitted 12 August, 2003; originally announced August 2003.

    Journal ref: Nucl.Instrum.Meth. A522 (2004) 274-293

  20. First Observation of the Rare Decay Mode K-long -> e+ e-

    Authors: BNL E871 Collaboration, D. Ambrose, C. Arroyo, M. Bachman, P. de Cecco, D. Connor, M. Eckhause, K. M. Ecklund, S. Graessle, A. D. Hancock, K. Hartman, M. Hebert, C. H. Hoff, G. W. Hoffmann, G. M. Irwin, J. R. Kane, N. Kanematsu, Y. Kuang, K. Lang, R. Lee, R. D. Martin, J. McDonough, A. Milder, W. R. Molzon, M. Pommot-Maia , et al. (9 additional authors not shown)

    Abstract: In an experiment designed to search for and study very rare two-body decay modes of the K-long, we have observed four examples of the decay K-long -> e+ e-, where the expected background is 0.17+-0.10 events. This observation translates into a branching fraction of 8.7^{+5.7}_{-4.1} X 10^{-12}, consistent with recent theoretical predictions. This result represents by far the smallest branching f… ▽ More

    Submitted 1 October, 1998; originally announced October 1998.

    Comments: 9 pages, 3 figures

    Report number: UTEXAS-HEP-98-14

    Journal ref: Phys.Rev.Lett.81:4309-4312,1998