-
Weighted Borel Generators
Authors:
Seth Ireland
Abstract:
Strongly stable ideals are a class of monomial ideals which correspond to generic initial ideals in characteristic zero and can be described completely by their Borel generators, a subset of the minimal monomial generators of the ideal. Francisco, Mermin, and Schweig developed formulas for the Hilbert series and Betti numbers of strongly stable ideals in terms of their Borel generators. In this wo…
▽ More
Strongly stable ideals are a class of monomial ideals which correspond to generic initial ideals in characteristic zero and can be described completely by their Borel generators, a subset of the minimal monomial generators of the ideal. Francisco, Mermin, and Schweig developed formulas for the Hilbert series and Betti numbers of strongly stable ideals in terms of their Borel generators. In this work, a specialization of strongly stable ideals is presented which further restricts the subset of relevant generators. A choice of weight vector $w\in\mathbb{N}_{> 0}^n$ restricts the set of strongly stable ideals to a subset designated as $w$-stable ideals. This restriction further compresses the Borel generators to a subset termed the weighted Borel generators of the ideal. A new Macaulay2 package wStableIdeals.m2 has been developed alongside this paper and segments of code support computations within.
△ Less
Submitted 26 August, 2024; v1 submitted 7 August, 2024;
originally announced August 2024.
-
A method for verifying the generalized Riemann hypothesis
Authors:
Ghaith Hiary,
Summer Ireland,
Megan Kyi
Abstract:
Riemann numerically approximated at least three zeta zeros. According to Edwards, Riemann even took steps to verify that the lowest zero he computed was indeed the first zeta zero. This approach to verification is developed, improved, and generalized to a large class of $L$-functions. Results of numerical calculations demonstrating the efficacy of the method are presented.
Riemann numerically approximated at least three zeta zeros. According to Edwards, Riemann even took steps to verify that the lowest zero he computed was indeed the first zeta zero. This approach to verification is developed, improved, and generalized to a large class of $L$-functions. Results of numerical calculations demonstrating the efficacy of the method are presented.
△ Less
Submitted 31 July, 2024;
originally announced August 2024.
-
The Most Sensitive Radio Recombination Line Measurements Ever Made of the Galactic Warm Ionized Medium
Authors:
T. M. Bania,
Dana S. Balser,
Trey V. Wenger,
Spencer J. Ireland,
L. D. Anderson,
Matteo Luisi
Abstract:
Diffuse ionized gas pervades the disk of the Milky Way. We detect extremely faint emission from this Galactic Warm Ionized Medium (WIM) using the Green Bank Telescope to make radio recombination line (RRL) observations toward two Milky Way sight lines: G20, $(\ell,{\it b}) = (20^\circ, 0^\circ)$, and G45, $(\ell,{\it b}) = (45^\circ, 0^\circ)$. We stack 18 consecutive Hn$α$ transitions between 4.3…
▽ More
Diffuse ionized gas pervades the disk of the Milky Way. We detect extremely faint emission from this Galactic Warm Ionized Medium (WIM) using the Green Bank Telescope to make radio recombination line (RRL) observations toward two Milky Way sight lines: G20, $(\ell,{\it b}) = (20^\circ, 0^\circ)$, and G45, $(\ell,{\it b}) = (45^\circ, 0^\circ)$. We stack 18 consecutive Hn$α$ transitions between 4.3-7.1 GHz to derive ${\rm \langle Hnα\rangle}$ spectra that are sensitive to RRL emission from plasmas with emission measures EM >10 ${\rm \,cm^{-6}\,pc}$. Each sight line has two Gaussian shaped spectral components with emission measures that range between $\sim$100 and $\sim$300 ${\rm \,cm^{-6}\,pc}$. Because there is no detectable RRL emission at negative LSR velocities the emitting plasma must be located interior to the Solar orbit. The G20 and G45 emission measures imply RMS densities of 0.15 and 0.18$\,{\rm cm^{-3}}$, respectively, if these sight lines are filled with homogeneous plasma. The observed ${\rm \langle Hnβ\rangle}$/${\rm \langle Hnα\rangle}$ line ratios are consistent with LTE excitation for the strongest components. The high velocity component of G20 has a narrow line width, 13.5 km s$^{-1}$, that sets an upper limit of <4,000 K for the plasma electron temperature. This is inconsistent with the ansatz of a canonically pervasive, low density, $\sim$ 10,000 K WIM plasma.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
-
A bijection between strongly stable and totally symmetric partitions
Authors:
Seth Ireland
Abstract:
Artinian monomial ideals in $d$ variables correspond to $d$-dimensional partitions. We define $d$-dimensional strongly stable partitions and show that they correspond to strongly stable ideals in $d$ variables. We show a bijection between strongly stable partitions and totally symmetric partitions which preserves the side length of the minimal bounding box.
Artinian monomial ideals in $d$ variables correspond to $d$-dimensional partitions. We define $d$-dimensional strongly stable partitions and show that they correspond to strongly stable ideals in $d$ variables. We show a bijection between strongly stable partitions and totally symmetric partitions which preserves the side length of the minimal bounding box.
△ Less
Submitted 19 April, 2023; v1 submitted 5 February, 2023;
originally announced February 2023.
-
Deep learning to achieve clinically applicable segmentation of head and neck anatomy for radiotherapy
Authors:
Stanislav Nikolov,
Sam Blackwell,
Alexei Zverovitch,
Ruheena Mendes,
Michelle Livne,
Jeffrey De Fauw,
Yojan Patel,
Clemens Meyer,
Harry Askham,
Bernardino Romera-Paredes,
Christopher Kelly,
Alan Karthikesalingam,
Carlton Chu,
Dawn Carnell,
Cheng Boon,
Derek D'Souza,
Syed Ali Moinuddin,
Bethany Garie,
Yasmin McQuinlan,
Sarah Ireland,
Kiarna Hampton,
Krystle Fuller,
Hugh Montgomery,
Geraint Rees,
Mustafa Suleyman
, et al. (4 additional authors not shown)
Abstract:
Over half a million individuals are diagnosed with head and neck cancer each year worldwide. Radiotherapy is an important curative treatment for this disease, but it requires manual time consuming delineation of radio-sensitive organs at risk (OARs). This planning process can delay treatment, while also introducing inter-operator variability with resulting downstream radiation dose differences. Wh…
▽ More
Over half a million individuals are diagnosed with head and neck cancer each year worldwide. Radiotherapy is an important curative treatment for this disease, but it requires manual time consuming delineation of radio-sensitive organs at risk (OARs). This planning process can delay treatment, while also introducing inter-operator variability with resulting downstream radiation dose differences. While auto-segmentation algorithms offer a potentially time-saving solution, the challenges in defining, quantifying and achieving expert performance remain. Adopting a deep learning approach, we demonstrate a 3D U-Net architecture that achieves expert-level performance in delineating 21 distinct head and neck OARs commonly segmented in clinical practice. The model was trained on a dataset of 663 deidentified computed tomography (CT) scans acquired in routine clinical practice and with both segmentations taken from clinical practice and segmentations created by experienced radiographers as part of this research, all in accordance with consensus OAR definitions. We demonstrate the model's clinical applicability by assessing its performance on a test set of 21 CT scans from clinical practice, each with the 21 OARs segmented by two independent experts. We also introduce surface Dice similarity coefficient (surface DSC), a new metric for the comparison of organ delineation, to quantify deviation between OAR surface contours rather than volumes, better reflecting the clinical task of correcting errors in the automated organ segmentations. The model's generalisability is then demonstrated on two distinct open source datasets, reflecting different centres and countries to model training. With appropriate validation studies and regulatory approvals, this system could improve the efficiency, consistency, and safety of radiotherapy pathways.
△ Less
Submitted 13 January, 2021; v1 submitted 12 September, 2018;
originally announced September 2018.