-
NEXO: Neutrinoless double beta decay search beyond $10^{28}$ year half-life sensitivity
Authors:
nEXO Collaboration,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
G. Anton,
I. J. Arnquist,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
D. Chernyak,
M. Chiu,
B. Cleveland
, et al. (136 additional authors not shown)
Abstract:
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the…
▽ More
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of $10^{28}$ years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of $1.35\times 10^{28}$ yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. The effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.
△ Less
Submitted 22 February, 2022; v1 submitted 30 June, 2021;
originally announced June 2021.
-
Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon
Authors:
M. Wagenpfeil,
T. Ziegler,
J. Schneider,
A. Fieguth,
M. Murra,
D. Schulte,
L. Althueser,
C. Huhmann,
C. Weinheimer,
T. Michel,
G. Anton,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
I. Badhrees,
J. Bane,
D. Beck,
V. Belov,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner
, et al. (118 additional authors not shown)
Abstract:
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows t…
▽ More
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. The reflectivity is determined to be 25-36% at an angle of incidence of 20° for the four samples and increases to up to 65% at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.
△ Less
Submitted 26 May, 2021; v1 submitted 16 April, 2021;
originally announced April 2021.
-
Constraints on Lightly Ionizing Particles from CDMSlite
Authors:
SuperCDMS Collaboration,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (93 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the v…
▽ More
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than $e/(3\times10^5$), as well as the strongest limits for charge $\leq e/160$, with a minimum vertical intensity of $1.36\times10^{-7}$\,cm$^{-2}$s$^{-1}$sr$^{-1}$ at charge $e/160$. These results apply over a wide range of LIP masses (5\,MeV/$c^2$ to 100\,TeV/$c^2$) and cover a wide range of $βγ$ values (0.1 -- $10^6$), thus excluding non-relativistic LIPs with $βγ$ as small as 0.1 for the first time.
△ Less
Submitted 19 February, 2022; v1 submitted 18 November, 2020;
originally announced November 2020.
-
Event Reconstruction in a Liquid Xenon Time Projection Chamber with an Optically-Open Field Cage
Authors:
T. Stiegler,
S. Sangiorgio,
J. P. Brodsky,
M. Heffner,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon
, et al. (126 additional authors not shown)
Abstract:
nEXO is a proposed tonne-scale neutrinoless double beta decay ($0νββ$) experiment using liquid ${}^{136}Xe$ (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe ("skin" LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier…
▽ More
nEXO is a proposed tonne-scale neutrinoless double beta decay ($0νββ$) experiment using liquid ${}^{136}Xe$ (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe ("skin" LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. In this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the $γ$-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Second, background from ${}^{222}Rn$ dissolved in the skin LXe can be efficiently rejected by tagging the $α$ decay in the ${}^{214}Bi-{}^{214}Po$ chain in the skin LXe.
△ Less
Submitted 24 March, 2021; v1 submitted 21 September, 2020;
originally announced September 2020.
-
The Majorana Demonstrator's Search for Double-Beta Decay of $^{76}$Ge to Excited States of $^{76}$Se
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
T. R. Edwards,
D. W. Edwins,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (38 additional authors not shown)
Abstract:
The Majorana Demonstrator is a neutrinoless double-beta decay search consisting of a low-background modular array of high-purity germanium detectors, $\sim2/3$ of which are enriched to 88\% in $^{76}$Ge. The experiment is also searching for double-beta decay of $^{76}$Ge to excited states (e.s.) in $^{76}$Se. $^{76}$Ge can decay into three daughter states of $^{76}$Se, with clear event signatures…
▽ More
The Majorana Demonstrator is a neutrinoless double-beta decay search consisting of a low-background modular array of high-purity germanium detectors, $\sim2/3$ of which are enriched to 88\% in $^{76}$Ge. The experiment is also searching for double-beta decay of $^{76}$Ge to excited states (e.s.) in $^{76}$Se. $^{76}$Ge can decay into three daughter states of $^{76}$Se, with clear event signatures consisting of a $ββ$-decay followed by the prompt emission of one or two $γ$-rays. This results with high probability in multi-detector coincidences. The granularity of the Demonstrator detector array enables powerful discrimination of this event signature from backgrounds. Using 41.9~kg-y of isotopic exposure, the Demonstrator has set world leading limits for each e.s.\ decay of $^{76}$Ge, with 90\% CL lower half-life limits in the range of $(0.75-4.0)\times10^{24}$~y. In particular, for the $2ν$ transition to the first $0^+$ e.s.\ of $^{76}$Se, a lower half-life limit of $7.5\times10^{23}$~y at 90\% CL was achieved.
△ Less
Submitted 24 February, 2021; v1 submitted 13 August, 2020;
originally announced August 2020.
-
Copper electroplating for background suppression in the NEWS-G experiment
Authors:
NEWS-G Collaboration,
:,
L. Balogh,
C. Beaufort,
A. Brossard,
R. Bunker,
J. -F. Caron,
M. Chapellier,
J. -M. Coquillat,
E. C. Corcoran,
S. Crawford,
A. Dastgheibi Fard,
Y. Deng,
K. Dering,
D. Durnford,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
I. Katsioulas,
F. Kelly
, et al. (26 additional authors not shown)
Abstract:
New Experiments with Spheres-Gas (NEWS-G) is a dark matter direct detection experiment that will operate at SNOLAB (Canada). Similar to other rare-event searches, the materials used in the detector construction are subject to stringent radiopurity requirements. The detector features a 140-cm diameter proportional counter comprising two hemispheres made from commercially sourced 99.99% pure copper.…
▽ More
New Experiments with Spheres-Gas (NEWS-G) is a dark matter direct detection experiment that will operate at SNOLAB (Canada). Similar to other rare-event searches, the materials used in the detector construction are subject to stringent radiopurity requirements. The detector features a 140-cm diameter proportional counter comprising two hemispheres made from commercially sourced 99.99% pure copper. Such copper is widely used in rare-event searches because it is readily available, there are no long-lived Cu radioisotopes, and levels of non-Cu radiocontaminants are generally low. However, measurements performed with a dedicated 210Po alpha counting method using an XIA detector confirmed a problematic concentration of 210Pb in bulk of the copper. To shield the proportional counter's active volume, a low-background electroforming method was adapted to the hemispherical shape to grow a 500-$μ$m thick layer of ultra-radiopure copper to the detector's inner surface. In this paper the process is described, which was prototyped at Pacific Northwest National Laboratory (PNNL), USA, and then conducted at full scale in the Laboratoire Souterrain de Modane in France. The radiopurity of the electroplated copper was assessed through Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Measurements of samples from the first (second) hemisphere give 68% confidence upper limits of <0.58 $μ$Bq/kg (<0.24 $μ$Bq/kg) and <0.26 $μ$Bq/kg (<0.11 $μ$Bq/kg) on the 232Th and 238U contamination levels, respectively. These results are comparable to previously reported measurements of electroformed copper produced for other rare-event searches, which were also found to have low concentration of 210Pb consistent with the background goals of the NEWS-G experiment.
△ Less
Submitted 13 December, 2020; v1 submitted 7 August, 2020;
originally announced August 2020.
-
Results on Low-Mass Weakly Interacting Massive Particles from an 11 kg-day Target Exposure of DAMIC at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
D. Baxter,
G. Cancelo,
B. A. Cervantes Vergara,
A. E. Chavarria,
J. C. D'Olivo,
J. Estrada,
F. Favela-Perez,
R. Gaior,
Y. Guardincerri,
E. W. Hoppe,
T. W. Hossbach,
B. Kilminster,
I. Lawson,
S. J. Lee,
A. Letessier-Selvon,
A. Matalon,
P. Mitra,
C. T. Overman,
A. Piers,
P. Privitera,
K. Ramanathan,
J. Da Rocha,
Y. Sarkis
, et al. (7 additional authors not shown)
Abstract:
We present constraints on the existence of weakly interacting massive particles (WIMPs) from an 11 kg-day target exposure of the DAMIC experiment at the SNOLAB underground laboratory. The observed energy spectrum and spatial distribution of ionization events with electron-equivalent energies $>$200 eV$_{\rm ee}$ in the DAMIC CCDs are consistent with backgrounds from natural radioactivity. An exces…
▽ More
We present constraints on the existence of weakly interacting massive particles (WIMPs) from an 11 kg-day target exposure of the DAMIC experiment at the SNOLAB underground laboratory. The observed energy spectrum and spatial distribution of ionization events with electron-equivalent energies $>$200 eV$_{\rm ee}$ in the DAMIC CCDs are consistent with backgrounds from natural radioactivity. An excess of ionization events is observed above the analysis threshold of 50 eV$_{\rm ee}$. While the origin of this low-energy excess requires further investigation, our data exclude spin-independent WIMP-nucleon scattering cross sections $σ_{χ-n}$ as low as $3\times 10^{-41}$ cm$^2$ for WIMPs with masses $m_χ$ from 7 to 10 GeV$c^{-2}$ . These results are the strongest constraints from a silicon target on the existence of WIMPs with $m_χ$$<$9 GeV$c^{-2}$ and are directly relevant to any dark matter interpretation of the excess of nuclear-recoil events observed by the CDMS silicon experiment in 2013.
△ Less
Submitted 25 December, 2020; v1 submitted 30 July, 2020;
originally announced July 2020.
-
Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground
Authors:
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (99 additional authors not shown)
Abstract:
We present limits on spin-independent dark matter-nucleon interactions using a $10.6$ $\mathrm{g}$ Si athermal phonon detector with a baseline energy resolution of $σ_E=3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.19}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matte…
▽ More
We present limits on spin-independent dark matter-nucleon interactions using a $10.6$ $\mathrm{g}$ Si athermal phonon detector with a baseline energy resolution of $σ_E=3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.19}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matter particle masses from $93$ to $140$ $\mathrm{MeV}/c^2$, with a raw exposure of $9.9$ $\mathrm{g}\cdot\mathrm{d}$ acquired at an above-ground facility. This work illustrates the scientific potential of detectors with athermal phonon sensors with eV-scale energy resolution for future dark matter searches.
△ Less
Submitted 12 October, 2021; v1 submitted 21 July, 2020;
originally announced July 2020.
-
Mass spectrometric analyses of high performance polymers to assess radiopurity as ultra low background materials for rare event physics detectors
Authors:
Jay W. Grate,
Isaac J. Arnquist,
Eric W. Hoppe,
Mary Bliss,
Khadouja Harouaka,
Maria Laura di Vacri,
Sonia Alcantar Anguiano
Abstract:
The mass concentrations of Th-232 and U-238 in several strong, unfilled, high performance polymers are reported as measures of their radiopurity. Highly radiopure polymers are required as dielectric materials in the construction of rare event physics detectors, in order to minimize background signals arising from the detector materials themselves. New data are reported for carefully sourced sample…
▽ More
The mass concentrations of Th-232 and U-238 in several strong, unfilled, high performance polymers are reported as measures of their radiopurity. Highly radiopure polymers are required as dielectric materials in the construction of rare event physics detectors, in order to minimize background signals arising from the detector materials themselves. New data are reported for carefully sourced samples of polyetheretherketone (PEEK), polyetherketoneketone (PEKK), a polyamide imide (PAI, branded as Torlon) and polybenzimidazole (PBI). Data for solid polyetherimide (PEI) are also discussed and new data for PEI in the form of a commercial 3D printing filament stock are reported. Strong high performance polymers PEKK, PBI, PAI and PEI were found with levels for Th-232 and U-238 that are below one milliBq/kg, including the PEI 3D printing filament. Specifically, for Th-232 and U-238 respectively, in microBq/kg, we found values of 149 and 184 for Arkema Kepstan PEKK 6002 flake; 69 and 2250 for Solvay Ketaspire PEEK flake; 346 and 291 for PBI Performance Products low metals grade 100 mesh PBI powder; 66 and 105 for Drake Plastics PAI Torlon T-4200 pellets; 401 and 285 for Drake Plastics cured PAI rod; 32 and 41 for Ensinger PEI Ultem 1000 solid; and 15 and 85 microBq/kg, for ThermaX PEI Ultem 1010 filament material. These results were all obtained using a novel dry ashing method in crucibles constructed of ultra low background (ULB) electroformed copper. Samples were spiked with T-229h and U-233 as internal standards prior to ashing and determinations were made by inductively coupled plasma mass spectrometry (ICP-MS). Radiopurity is displayed graphically relative to numerical measures of mechanical strength for these and several other polymers.
△ Less
Submitted 6 July, 2020;
originally announced July 2020.
-
$α$-event Characterization and Rejection in Point-Contact HPGe Detectors
Authors:
The MAJORANA Collaboration,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
T. R. Edwards,
D. W. Edwins,
Yu. Efremenko,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (40 additional authors not shown)
Abstract:
P-type point contact (PPC) HPGe detectors are a leading technology for rare event searches due to their excellent energy resolution, low thresholds, and multi-site event rejection capabilities. We have characterized a PPC detector's response to $α$ particles incident on the sensitive passivated and p+ surfaces, a previously poorly-understood source of background. The detector studied is identical…
▽ More
P-type point contact (PPC) HPGe detectors are a leading technology for rare event searches due to their excellent energy resolution, low thresholds, and multi-site event rejection capabilities. We have characterized a PPC detector's response to $α$ particles incident on the sensitive passivated and p+ surfaces, a previously poorly-understood source of background. The detector studied is identical to those in the MAJORANA DEMONSTRATOR experiment, a search for neutrinoless double-beta decay ($0νββ$) in $^{76}$Ge. $α$ decays on most of the passivated surface exhibit significant energy loss due to charge trapping, with waveforms exhibiting a delayed charge recovery (DCR) signature caused by the slow collection of a fraction of the trapped charge. The DCR is found to be complementary to existing methods of $α$ identification, reliably identifying $α$ background events on the passivated surface of the detector. We demonstrate effective rejection of all surface $α$ events (to within statistical uncertainty) with a loss of only 0.2% of bulk events by combining the DCR discriminator with previously-used methods. The DCR discriminator has been used to reduce the background rate in the $0νββ$ region of interest window by an order of magnitude in the MAJORANA DEMONSTRATOR, and will be used in the upcoming LEGEND-200 experiment.
△ Less
Submitted 14 March, 2022; v1 submitted 23 June, 2020;
originally announced June 2020.
-
Direct method for the quantitative analysis of surface contamination on ultra-low background materials from exposure to dust
Authors:
M. L. di Vacri,
I. J. Arnquist,
S. Scorza,
E. W. Hoppe,
Jeter Hall
Abstract:
In this work we present a method for the direct determination of contaminant fallout rates on material surfaces from exposure to dust. Naturally occurring radionuclides K-40, Th-232, U-238 and stable Pb were investigated. Until now, background contributions from dust particulate have largely been estimated from fallout models and assumed dust composition. Our method utilizes a variety of low backg…
▽ More
In this work we present a method for the direct determination of contaminant fallout rates on material surfaces from exposure to dust. Naturally occurring radionuclides K-40, Th-232, U-238 and stable Pb were investigated. Until now, background contributions from dust particulate have largely been estimated from fallout models and assumed dust composition. Our method utilizes a variety of low background collection media for exposure in locations of interest, followed by surface leaching and leachate analysis using inductively coupled plasma mass spectrometry (ICP-MS). The method was validated and applied in selected locations at Pacific Northwest National Laboratory (PNNL) and the SNOLAB underground facility.
△ Less
Submitted 23 June, 2020;
originally announced June 2020.
-
Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector
Authors:
SuperCDMS Collaboration,
D. W. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
R. Chen,
N. Chott,
J. Cooley
, et al. (94 additional authors not shown)
Abstract:
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a…
▽ More
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 gram-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section $\barσ_{e}$ is constrained for dark matter masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50 eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90% confidence-level upper limits within the above mentioned mass ranges are $\barσ_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$, $\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
△ Less
Submitted 29 January, 2021; v1 submitted 28 May, 2020;
originally announced May 2020.
-
Doping-induced spin Hall ratio enhancement in A15-phase, Ta-doped Beta-W thin films
Authors:
Mohsin Z. Minhas,
Avanindra K. Pandeya,
Bharat Grover,
Alessandro Fumarola,
Ilya Kostanovskiy,
Wolfgang Hoppe,
Georg Woltersdorf,
Amilcar Bedoya-Pinto,
Stuart S. P. Parkin,
Mazhar N. Ali
Abstract:
As spintronic devices become more and more prevalent, the desire to find Pt free materials with large spin Hall effects is increasing. Previously it was shown that Beta W, the metastable A15 structured variant of pure W, has charge-spin conversion efficiencies on par with Pt, and it was predicted that Beta W(Ta) alloys should be even more efficient. Here we demonstrate the enhancement of the spin…
▽ More
As spintronic devices become more and more prevalent, the desire to find Pt free materials with large spin Hall effects is increasing. Previously it was shown that Beta W, the metastable A15 structured variant of pure W, has charge-spin conversion efficiencies on par with Pt, and it was predicted that Beta W(Ta) alloys should be even more efficient. Here we demonstrate the enhancement of the spin Hall ratio (SHR) in A15-phase Beta W films doped with Ta (W(4-x)Tax where x is between 0.28 and 0.4, deposited at room temperature using DC magnetron co-sputtering. In close agreement with theoretical predictions, we find that the SHR of the doped films was approx. 9 percent larger than pure Beta W films. We also found that the SHRs in devices with Co2Fe6B2 were nearly twice as large as the SHRs in devices with Co4Fe4B2. This work shows that by optimizing deposition parameters and substrates, the fabrication of the optimum W3Ta alloy should be feasible, opening the door to commercially viable, Pt free, spintronic devices.
△ Less
Submitted 18 May, 2020; v1 submitted 15 May, 2020;
originally announced May 2020.
-
SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range
Authors:
The DarkSide collaboration,
C. E. Aalseth,
S. Abdelhakim,
P. Agnes,
R. Ajaj,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
F. Ameli,
J. Anstey,
P. Antonioli,
M. Arba,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
P. Arpaia,
D. M. Asner,
A. Asunskis,
M. Ave,
H. O. Back,
V. Barbaryan,
A. Barrado Olmedo,
G. Batignani
, et al. (290 additional authors not shown)
Abstract:
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the…
▽ More
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms ("neutral bremsstrahlung", NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.
△ Less
Submitted 26 February, 2021; v1 submitted 4 April, 2020;
originally announced April 2020.
-
ADC Nonlinearity Correction for the MAJORANA DEMONSTRATOR
Authors:
N. Abgrall,
J. M. Allmond,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
C. M. Campbell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
H. L. Crawford,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
D. W. Edwins,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss
, et al. (42 additional authors not shown)
Abstract:
Imperfections in analog-to-digital conversion (ADC) cannot be ignored when signal digitization requirements demand both wide dynamic range and high resolution, as is the case for the Majorana Demonstrator 76Ge neutrinoless double beta decay search. Enabling the experiment's high-resolution spectral analysis and efficient pulse shape discrimination required careful measurement and correction of ADC…
▽ More
Imperfections in analog-to-digital conversion (ADC) cannot be ignored when signal digitization requirements demand both wide dynamic range and high resolution, as is the case for the Majorana Demonstrator 76Ge neutrinoless double beta decay search. Enabling the experiment's high-resolution spectral analysis and efficient pulse shape discrimination required careful measurement and correction of ADC nonlinearites. A simple measurement protocol was developed that did not require sophisticated equipment or lengthy data taking campaigns. A slope-dependent hysteresis was observed and characterized. A correction applied to digitized waveforms prior to signal processing reduced the differential and integral nonlinearites by an order of magnitude, eliminating these as dominant contributions to the systematic energy uncertainty at the double-beta decay Q value.
△ Less
Submitted 24 March, 2021; v1 submitted 4 March, 2020;
originally announced March 2020.
-
Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon
Authors:
The DarkSide Collaboration,
C. E. Aalseth,
S. Abdelhakim,
F. Acerbi,
P. Agnes,
R. Ajaj,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
F. Ameli,
J. Anstey,
P. Antonioli,
M. Arba,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
P. Arpaia,
D. M. Asner,
A. Asunskis,
M. Ave,
H. O. Back,
A. Barrado Olmedo,
G. Batignani
, et al. (306 additional authors not shown)
Abstract:
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioa…
▽ More
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, $^{39}$Ar, a $β$ emitter of cosmogenic origin. For large detectors, the atmospheric $^{39}$Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of $^{39}$Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of $^{39}$Ar with respect to AAr by a factor larger than 1400. Assessing the $^{39}$Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly $γ$-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.
△ Less
Submitted 22 January, 2020;
originally announced January 2020.
-
A Low Energy Rare Event Search with the Majorana Demonstrator
Authors:
MAJORANA Collaboration,
C. Wiseman,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
D. W. Edwins,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (37 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is sensitive to rare events near its energy threshold, including bosonic dark matter, solar axions, and lightly ionizing particles. In this analysis, a novel training set of low energy small-angle Compton scatter events is used to determine the efficiency of pulse shape analysis cuts, and we present updated bosonic dark matter and solar axion results from an 11.17 kg-y da…
▽ More
The MAJORANA DEMONSTRATOR is sensitive to rare events near its energy threshold, including bosonic dark matter, solar axions, and lightly ionizing particles. In this analysis, a novel training set of low energy small-angle Compton scatter events is used to determine the efficiency of pulse shape analysis cuts, and we present updated bosonic dark matter and solar axion results from an 11.17 kg-y dataset using a 5 keV analysis threshold.
△ Less
Submitted 12 December, 2019;
originally announced December 2019.
-
Results of the MAJORANA DEMONSTRATOR's Search for Double-Beta Decay of $^{76}$Ge to Excited States of $^{76}$Se
Authors:
I. S. Guinn,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P-H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
D. W. Edwins,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko
, et al. (35 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is searching for double-beta decay of $^{76}$Ge to excited states (E.S.) in $^{76}$Se using a modular array of high purity Germanium detectors. $^{76}$Ge can decay into three E.S.s of $^{76}$Se. The E.S. decays have a clear event signature consisting of a $ββ$-decay with the prompt emission of one or two $γ$-rays, resulting in with high probability in a multi-site event.…
▽ More
The MAJORANA DEMONSTRATOR is searching for double-beta decay of $^{76}$Ge to excited states (E.S.) in $^{76}$Se using a modular array of high purity Germanium detectors. $^{76}$Ge can decay into three E.S.s of $^{76}$Se. The E.S. decays have a clear event signature consisting of a $ββ$-decay with the prompt emission of one or two $γ$-rays, resulting in with high probability in a multi-site event. The granularity of the DEMONSTRATOR detector array enables powerful discrimination of this event signature from backgrounds. Using 21.3 kg-y of isotopic exposure, the DEMONSTRATOR has set world leading limits for each E.S. decay, with 90% CL lower half-life limits in the range of $(0.56-2.1)\cdot10^{24}$ y. In particular, for the $2ν$ transition to the first $0^+$ E.S. of $^{76}$Se, a lower half-life limit of $0.68\cdot10^{24}$ at 90% CL was achieved.
△ Less
Submitted 11 December, 2019;
originally announced December 2019.
-
Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths
Authors:
P. Lv,
G. F. Cao,
L. J. Wen,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
S. Byrne Mamahit,
E. Caden,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon,
A. Craycraft
, et al. (126 additional authors not shown)
Abstract:
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angular dependence of the specular reflectance in a vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 nm to 280 nm. Refractive index and extinct…
▽ More
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angular dependence of the specular reflectance in a vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 nm to 280 nm. Refractive index and extinction coefficient of the thin silicon-dioxide film deposited on the surface of the FBK SiPMs are derived from reflectance data of a FBK silicon wafer with the same deposited oxide film as SiPMs. The diffuse reflectance of SiPMs is also measured at 193 nm. We use the VUV spectral dependence of the optical constants to predict the reflectance of the FBK silicon wafer and FBK SiPMs in liquid xenon.
△ Less
Submitted 4 December, 2019;
originally announced December 2019.
-
Constraints on dark photons and axion-like particles from SuperCDMS Soudan
Authors:
SuperCDMS Collaboration,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
J. Cooley,
H. Coombes,
J. Corbett
, et al. (82 additional authors not shown)
Abstract:
We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 5…
▽ More
We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 500 eV/$c^2$ for both candidates, excluding previously untested parameter space for masses below ~1 keV/$c^2$. For the kinetic mixing of dark photons, values below $10^{-15}$ are reached for particle masses around 100 eV/$c^2$; for the axioelectric coupling of axion-like particles, values below $10^{-12}$ are reached for particles with masses in the range of a few-hundred eV/$c^2$.
△ Less
Submitted 18 January, 2021; v1 submitted 26 November, 2019;
originally announced November 2019.
-
Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode
Authors:
O. Njoya,
T. Tsang,
M. Tarka,
W. Fairbank,
K. S. Kumar,
T. Rao,
T. Wager,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
B. Chana,
S. A. Charlebois
, et al. (131 additional authors not shown)
Abstract:
Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measur…
▽ More
Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measured drift velocities and corresponding temperature coefficients respectively are $1.97 \pm 0.04$ mm/$μ$s and $(-0.69\pm0.05)$\%/K for liquid xenon, and $1.42 \pm 0.03$ mm/$μ$s and $(+0.11\pm0.01)$\%/K for gaseous xenon at 1.5 bar. In addition, we measure longitudinal diffusion coefficients of $25.7 \pm 4.6$ cm$^2$/s and $149 \pm 23$ cm$^2$/s, for liquid and gas, respectively. The quantum efficiency of the gold photocathode is studied at the photon energy of 4.73 eV in liquid and gaseous xenon, and vacuum. These charge transport properties and the behavior of photocathodes in a xenon environment are important in designing and calibrating future large scale noble liquid detectors.
△ Less
Submitted 24 November, 2019;
originally announced November 2019.
-
Reflectivity and PDE of VUV4 Hamamatsu SiPMs in Liquid Xenon
Authors:
P. Nakarmi,
I. Ostrovskiy,
A. K. Soma,
F. Retiere,
S. Al Kharusi,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. Blatchford,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
S. Byrne Mamahit,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois
, et al. (130 additional authors not shown)
Abstract:
Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE. Little information is currently a…
▽ More
Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE. Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 micrometer micro-cells conducted with xenon scintillation light (~175 nm) in liquid xenon. The specular reflectivity at 15 deg. incidence of three samples of VUV4 SiPMs is found to be 30.4+/-1.4%, 28.6+/-1.3%, and 28.0+/-1.3%, respectively. The PDE at normal incidence differs by +/-8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was also measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.
△ Less
Submitted 24 December, 2019; v1 submitted 14 October, 2019;
originally announced October 2019.
-
Velocity independent constraints on spin-dependent DM-nucleon interactions from IceCube and PICO
Authors:
IceCube Collaboration,
M. G. Aartsen,
M. Ackermann,
J. Adams,
J. A. Aguilar,
M. Ahlers,
M. Ahrens,
C. Alispach,
K. Andeen,
T. Anderson,
I. Ansseau,
G. Anton,
C. Argüelles,
J. Auffenberg,
S. Axani,
P. Backes,
H. Bagherpour,
X. Bai,
A. Balagopal V.,
A. Barbano,
S. W. Barwick,
B. Bastian,
V. Baum,
S. Baur,
R. Bay
, et al. (398 additional authors not shown)
Abstract:
Adopting the Standard Halo Model (SHM) of an isotropic Maxwellian velocity distribution for dark matter (DM) particles in the Galaxy, the most stringent current constraints on their spin-dependent scattering cross-section with nucleons come from the IceCube neutrino observatory and the PICO-60 C$_3$F$_8$ superheated bubble chamber experiments. The former is sensitive to high energy neutrinos from…
▽ More
Adopting the Standard Halo Model (SHM) of an isotropic Maxwellian velocity distribution for dark matter (DM) particles in the Galaxy, the most stringent current constraints on their spin-dependent scattering cross-section with nucleons come from the IceCube neutrino observatory and the PICO-60 C$_3$F$_8$ superheated bubble chamber experiments. The former is sensitive to high energy neutrinos from the self-annihilation of DM particles captured in the Sun, while the latter looks for nuclear recoil events from DM scattering off nucleons. Although slower DM particles are more likely to be captured by the Sun, the faster ones are more likely to be detected by PICO. Recent N-body simulations suggest significant deviations from the SHM for the smooth halo component of the DM, while observations hint at a dominant fraction of the local DM being in substructures. We use the method of Ferrer et al. (2015) to exploit the complementarity between the two approaches and derive conservative constraints on DM-nucleon scattering. Our results constrain $σ_{\mathrm{SD}} \lesssim 3 \times 10^{-39} \mathrm{cm}^2$ (6 $ \times 10^{-38} \mathrm{cm}^2$) at $\gtrsim 90\%$ C.L. for a DM particle of mass 1~TeV annihilating into $τ^+ τ^-$ ($b\bar{b}$) with a local density of $ρ_{\mathrm{DM}} = 0.3~\mathrm{ GeV/cm}^3$. The constraints scale inversely with $ρ_{\mathrm{DM}}$ and are independent of the DM velocity distribution.
△ Less
Submitted 25 May, 2020; v1 submitted 29 July, 2019;
originally announced July 2019.
-
Simulation of charge readout with segmented tiles in nEXO
Authors:
Z. Li,
W. R. Cen,
A. Robinson,
D. C. Moore,
L. J. Wen,
A. Odian,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland
, et al. (128 additional authors not shown)
Abstract:
nEXO is a proposed experiment to search for the neutrino-less double beta decay ($0νββ$) of $^{136}$Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC will be equipped with charge collection tiles to form the anode. In this work, the charge reconstruction performance of this anode design is studied with a dedicated simulation package. A multi-variate method and a deep neu…
▽ More
nEXO is a proposed experiment to search for the neutrino-less double beta decay ($0νββ$) of $^{136}$Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC will be equipped with charge collection tiles to form the anode. In this work, the charge reconstruction performance of this anode design is studied with a dedicated simulation package. A multi-variate method and a deep neural network are developed to distinguish simulated $0νββ$ signals from backgrounds arising from trace levels of natural radioactivity in the detector materials. These simulations indicate that the nEXO TPC with charge-collection tiles shows promising capability to discriminate the $0νββ$ signal from backgrounds. The estimated half-life sensitivity for $0νββ$ decay is improved by $\sim$20$~(32)\%$ with the multi-variate~(deep neural network) methods considered here, relative to the sensitivity estimated in the nEXO pre-conceptual design report.
△ Less
Submitted 11 October, 2019; v1 submitted 17 July, 2019;
originally announced July 2019.
-
Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$ Bubble Chambers
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
G. Cao,
C. J. Chen,
S. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. B. Coutu,
C. Cowles,
M. Crisler,
G. Crowder,
N. A. Cruz-Venegas,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
R. Filgas
, et al. (54 additional authors not shown)
Abstract:
The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by…
▽ More
The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by a hot-spike as previously supposed. Using this semi-empirical model, bubble chamber nucleation thresholds may be tuned to be sensitive to lower energy nuclear recoils while maintaining excellent electron recoil rejection. The PICO-40L detector will exploit this model to achieve thermodynamic thresholds as low as 2.8 keV while being dominated by single-scatter events from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one year of operation, PICO-40L can improve existing leading limits from PICO on spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP masses greater than 3 GeV c$^{-2}$ and will have the ability to surpass all existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP masses from 3 to 40 GeV c$^{-2}$.
△ Less
Submitted 25 November, 2020; v1 submitted 29 May, 2019;
originally announced May 2019.
-
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
Authors:
G. Gallina,
P. Giampa,
F. Retiere,
J. Kroeger,
G. Zhang,
M. Ward,
P. Margetak,
G. Lic,
T. Tsang,
L. Doria,
S. Al Kharusi,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. Blatchford,
J. P. Brodsky,
E. Brown,
T. Brunner,
G. F. Cao,
L. Cao
, et al. (126 additional authors not shown)
Abstract:
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency…
▽ More
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233 \text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163 \text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse in the $1 \upmu\text{s}$ interval following the trigger pulse of $0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is $0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of $189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both values are well below the $24\text{ }\%$ saturation PDE advertised by Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBK-LF SiPMs for the final design of the nEXO detector.
△ Less
Submitted 7 June, 2019; v1 submitted 8 March, 2019;
originally announced March 2019.
-
Precision laser-based measurements of the single electron response of SPCs for the NEWS-G light dark matter search experiment
Authors:
NEWS-G Collaboration,
:,
Q. Arnaud,
J. -P. Bard,
A. Brossard,
M. Chapellier,
M. Clark,
S. Crawford,
E. C. Corcoran,
A. Dastgheibi-Fard,
K. Dering,
P. Di Stefano,
D. Durnford,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
A. Kamaha,
I. Katsioulas,
D. G. Kelly,
P. Knights
, et al. (15 additional authors not shown)
Abstract:
Spherical Proportional Counters (SPCs) are a novel gaseous detector technology employed by the NEWS-G low-mass dark matter search experiment for their high sensitivity to single electrons from ionization. In this paper, we report on the first characterization of the single electron response of SPCs with unprecedented precision, using a UV-laser calibration system. The experimental approach and ana…
▽ More
Spherical Proportional Counters (SPCs) are a novel gaseous detector technology employed by the NEWS-G low-mass dark matter search experiment for their high sensitivity to single electrons from ionization. In this paper, we report on the first characterization of the single electron response of SPCs with unprecedented precision, using a UV-laser calibration system. The experimental approach and analysis methodology are presented along with various direct applications for the upcoming next phase of the experiment at SNOLAB. These include the continuous monitoring of the detector response and electron drift properties during dark matter search runs, as well as the experimental measurement of the trigger threshold efficiency. We measure a mean ionization energy of $\mathrm{W}=27.6\pm0.2~\mathrm{eV}$ in $\mathrm{Ne + CH_4}$ $(2\%)$ for 2.8 keV X-rays, and demonstrate the feasibility of performing similar precision measurements at sub-keV energies for future gas mixtures to be used for dark matter searches at SNOLAB.
△ Less
Submitted 24 February, 2019;
originally announced February 2019.
-
Dark Matter Search Results from the Complete Exposure of the PICO-60 C$_3$F$_8$ Bubble Chamber
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
G. Cao,
C. J. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. B. Coutu,
C. Cowles,
M. Crisler,
G. Crowder,
N. A. Cruz-Venegas,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
I. Felis,
R. Filgas
, et al. (47 additional authors not shown)
Abstract:
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total backgr…
▽ More
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total background rate as the previous 1167-kg-day exposure at 3.3 keV. This increased exposure is enabled in part by a new optical tracking analysis to better identify events near detector walls, permitting a larger fiducial volume. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 2.5 $\times$ 10$^{-41}$ cm$^2$ for a 25 GeV WIMP, and improve on previous PICO results for 3-5 GeV WIMPs by an order of magnitude.
△ Less
Submitted 11 February, 2019;
originally announced February 2019.
-
A Search for Neutrinoless Double-Beta Decay in $^{76}$Ge with 26 kg-yr of Exposure from the MAJORANA DEMONSTRATOR
Authors:
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
V. Basu,
F. E. Bertrand,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (39 additional authors not shown)
Abstract:
The MAJORANA Collaboration is operating an array of high purity Ge detectors to search for the neutrinoless double-beta decay of $^{76}$Ge. The MAJORANA DEMONSTRATOR consists of 44.1 kg of Ge detectors (29.7 kg enriched to 88% in $^{76}$Ge) split between two modules constructed from ultra-clean materials. Both modules are contained in a low-background shield at the Sanford Underground Research Fac…
▽ More
The MAJORANA Collaboration is operating an array of high purity Ge detectors to search for the neutrinoless double-beta decay of $^{76}$Ge. The MAJORANA DEMONSTRATOR consists of 44.1 kg of Ge detectors (29.7 kg enriched to 88% in $^{76}$Ge) split between two modules constructed from ultra-clean materials. Both modules are contained in a low-background shield at the Sanford Underground Research Facility in Lead, South Dakota. We present updated results on the search for neutrinoless double-beta decay in $^{76}$Ge with $26.0\pm0.5$ kg-yr of enriched exposure. With the DEMONSTRATOR's unprecedented energy resolution of 2.53 keV FWHM at $Q_{ββ}$, we observe one event in the region of interest with 0.65 events expected from the estimated background, resulting in a lower limit on the $^{76}$Ge neutrinoless double-beta decay half-life of $2.7\times10^{25}$ yr (90% CL) with a median sensitivity of $4.8\times10^{25}$ yr (90% CL). Depending on the matrix elements used, a 90% CL upper limit on the effective Majorana neutrino mass in the range of 200-433 meV is obtained. The measured background in the low-background configurations is $11.9\pm2.0$ counts/(FWHM t yr).
△ Less
Submitted 6 February, 2019;
originally announced February 2019.
-
Multi-site event discrimination for the MAJORANA DEMONSTRATOR
Authors:
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
B. Bos,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe,
R. J. Hegedus,
L. Hehn
, et al. (38 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is searching for neutrinoless double-beta decay in 76Ge using arrays of point-contact germanium detectors operating at the Sanford Underground Research Facility. Background results in the neutrinoless double-beta decay region of interest from data taken during construction, commissioning, and the start of full operations have been recently published. A pulse shape analysi…
▽ More
The MAJORANA DEMONSTRATOR is searching for neutrinoless double-beta decay in 76Ge using arrays of point-contact germanium detectors operating at the Sanford Underground Research Facility. Background results in the neutrinoless double-beta decay region of interest from data taken during construction, commissioning, and the start of full operations have been recently published. A pulse shape analysis cut applied to achieve this result, named AvsE, is described in this paper. This cut is developed to remove events whose waveforms are typical of multi-site energy deposits while retaining (90 +/- 3.5)% of single-site events. This pulse shape discrimination is based on the relationship between the maximum current and energy, and tuned using 228Th calibration source data. The efficiency uncertainty accounts for variation across detectors, energy, and time, as well as for the position distribution difference between calibration and $0νββ$ events, established using simulations.
△ Less
Submitted 16 January, 2019;
originally announced January 2019.
-
Recent results from the MAJORANA DEMONSTRATOR
Authors:
J. Myslik,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
B. Bos,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (43 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decay in $^{76}$Ge and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modules of natural and $^{76}$Ge-enriched germanium detectors totalling 44.1 kg, operating at the 4850' level of the Sanford Underground Research Facility in Lead, S…
▽ More
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decay in $^{76}$Ge and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modules of natural and $^{76}$Ge-enriched germanium detectors totalling 44.1 kg, operating at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. Commissioning of the experiment began in June 2015, followed by data production with the full detector array in August 2016. The ultra-low background and record energy resolution achieved by the MAJORANA DEMONSTRATOR enable a sensitive neutrinoless double-beta decay search, as well as additional searches for physics beyond the Standard Model. I will discuss the design elements that enable these searches, along with the latest results, focusing on the neutrinoless double-beta decay search. I will also discuss the current status and the future plans of the MAJORANA DEMONSTRATOR, as well as the plans for a future tonne-scale $^{76}$Ge experiment.
△ Less
Submitted 19 December, 2018;
originally announced December 2018.
-
Search for Tri-Nucleon Decay in the Majorana Demonstrator
Authors:
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
B. Bos,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (41 additional authors not shown)
Abstract:
The Majorana Demonstrator is an ultra low-background experiment searching for neutrinoless double-beta decay in $^{76}$Ge. The heavily shielded array of germanium detectors, placed nearly a mile underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. We present the first limits for tri-nucleon decay-specific modes and invisible d…
▽ More
The Majorana Demonstrator is an ultra low-background experiment searching for neutrinoless double-beta decay in $^{76}$Ge. The heavily shielded array of germanium detectors, placed nearly a mile underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. We present the first limits for tri-nucleon decay-specific modes and invisible decay modes for Ge isotopes. We find a half-life limit of $4.9 \times 10^{25}$ yr for the decay $^{76}{\rm Ge(ppn)} \to {}^{73}{\rm Zn}\ e^+π^+$ and $4.7\times10^{25}$ yr for the decay $^{76}{\rm Ge(ppp)} \to ^{73}{\rm Cu}\ e^+π^+π^+$. The half-life limit for the invisible tri-proton decay mode of $^{76}$Ge was found to be $7.5\times10^{24}$ yr.
△ Less
Submitted 26 March, 2019; v1 submitted 3 December, 2018;
originally announced December 2018.
-
Developing a Bubble Chamber Particle Discriminator Using Semi-Supervised Learning
Authors:
B. Matusch,
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
G. Cao,
C. J. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. B. Coutu,
C. Cowles,
M. Crisler,
G. Crowder,
N. A. Cruz-Venegas,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
I. Felis
, et al. (48 additional authors not shown)
Abstract:
The identification of non-signal events is a major hurdle to overcome for bubble chamber dark matter experiments such as PICO-60. The current practice of manually developing a discriminator function to eliminate background events is difficult when available calibration data is frequently impure and present only in small quantities. In this study, several different discriminator input/preprocessing…
▽ More
The identification of non-signal events is a major hurdle to overcome for bubble chamber dark matter experiments such as PICO-60. The current practice of manually developing a discriminator function to eliminate background events is difficult when available calibration data is frequently impure and present only in small quantities. In this study, several different discriminator input/preprocessing formats and neural network architectures are applied to the task. First, they are optimized in a supervised learning context. Next, two novel semi-supervised learning algorithms are trained, and found to replicate the Acoustic Parameter (AP) discriminator previously used in PICO-60 with a mean of 97% accuracy.
△ Less
Submitted 27 November, 2018;
originally announced November 2018.
-
Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
F. De Brienne,
T. Doughty
, et al. (78 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than…
▽ More
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than was used for the two previous CDMSlite data sets. This analysis includes a data "salting" method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$ cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous CDMSlite result.
△ Less
Submitted 2 January, 2021; v1 submitted 27 August, 2018;
originally announced August 2018.
-
Treatment of material radioassay measurements in projecting sensitivity for low-background experiments
Authors:
R. H. M. Tsang,
I. J. Arnquist,
E. W. Hoppe,
J. L. Orrell,
R. Saldanha
Abstract:
By analyzing sensitivity projections as a statisical estimation problem, we evaluated different ways of treating radioassay measurement results (values and upper limits) when projecting sensitivity for low-background experiments. We developed a figure of merit that incorporates a notion of conservativeness to quantitatively explore the consequences of attempts to bias sensitivity projections, and…
▽ More
By analyzing sensitivity projections as a statisical estimation problem, we evaluated different ways of treating radioassay measurement results (values and upper limits) when projecting sensitivity for low-background experiments. We developed a figure of merit that incorporates a notion of conservativeness to quantitatively explore the consequences of attempts to bias sensitivity projections, and proposed a method to report sensitivity.
△ Less
Submitted 28 August, 2018; v1 submitted 15 August, 2018;
originally announced August 2018.
-
Study of Silicon Photomultiplier Performance in External Electric Fields
Authors:
X. L. Sun,
T. Tolba,
G. F. Cao,
P. Lv,
L. J. Wen,
A. Odian,
F. Vachon,
A. Alamre,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois
, et al. (127 additional authors not shown)
Abstract:
We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estima…
▽ More
We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estimated uncertainties. No observable physical damage to the bulk or surface of the devices was caused by the exposure.
△ Less
Submitted 9 July, 2018;
originally announced July 2018.
-
Imaging individual barium atoms in solid xenon for barium tagging in nEXO
Authors:
C. Chambers,
T. Walton,
D. Fairbank,
A. Craycraft,
D. R. Yahne,
J. Todd,
A. Iverson,
W. Fairbank,
A. Alamare,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen
, et al. (126 additional authors not shown)
Abstract:
The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or 'tagging', of the $^{136}$Ba daughter atom from double beta decay of $^{136}$Xe provides a…
▽ More
The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or 'tagging', of the $^{136}$Ba daughter atom from double beta decay of $^{136}$Xe provides a technique for eliminating backgrounds in the nEXO neutrinoless double beta decay experiment. The tagging scheme studied in this work utilizes a cryogenic probe to trap the barium atom in solid xenon, where the barium atom is tagged via fluorescence imaging in the solid xenon matrix. Here we demonstrate imaging and counting of individual atoms of barium in solid xenon by scanning a focused laser across a solid xenon matrix deposited on a sapphire window. When the laser sits on an individual atom, the fluorescence persists for $\sim$30~s before dropping abruptly to the background level, a clear confirmation of one-atom imaging. No barium fluorescence persists following evaporation of a barium deposit to a limit of $\leq$0.16\%. This is the first time that single atoms have been imaged in solid noble element. It establishes the basic principle of a barium tagging technique for nEXO.
△ Less
Submitted 12 December, 2018; v1 submitted 27 June, 2018;
originally announced June 2018.
-
Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in Germanium with CDMSlite
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
T. Doughty,
E. Fascione,
E. Figueroa-Feliciano,
C. W. Fink
, et al. (73 additional authors not shown)
Abstract:
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected prod…
▽ More
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected production rates, and analyze data from the second run of the CDMS low ionization threshold experiment (CDMSlite) to estimate the rates for several isotopes. We model the measured CDMSlite spectrum and fit for contributions from tritium and other isotopes. Using the knowledge of the detector history, these results are converted to cosmogenic production rates at sea level. The production rates in atoms/(kg$\cdot$day) are 74$\pm$9 for $^3$H, 1.5$\pm$0.7 for $^{55}$Fe, 17$\pm$5 for $^{65}$Zn, and 30$\pm$18 for $^{68}$Ge.
△ Less
Submitted 16 August, 2019; v1 submitted 19 June, 2018;
originally announced June 2018.
-
VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO
Authors:
A. Jamil,
T. Ziegler,
P. Hufschmidt,
G. Li,
L. Lupin-Jimenez,
T. Michel,
I. Ostrovskiy,
F. Retière,
J. Schneider,
M. Wagenpfeil,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. Barbeau,
D. Beck,
V. Belov,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers
, et al. (118 additional authors not shown)
Abstract:
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area avalanche photodiodes. The next generation double beta decay experiment, nEXO, with a 5 tonne liquid xenon time projection chamber, will use SiPMs for detecting t…
▽ More
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area avalanche photodiodes. The next generation double beta decay experiment, nEXO, with a 5 tonne liquid xenon time projection chamber, will use SiPMs for detecting the $178\,\text{nm}$ xenon scintillation light, in order to achieve an energy resolution of $σ/ Q_{ββ} = 1\, \%$. This paper presents recent measurements of the VUV-HD generation SiPMs from Fondazione Bruno Kessler in two complementary setups. It includes measurements of the photon detection efficiency with gaseous xenon scintillation light in a vacuum setup and dark measurements in a dry nitrogen gas setup. We report improved photon detection efficiency at $175\,\text{nm}$ compared to previous generation devices, that would meet the criteria of nEXO. Furthermore, we present the projected nEXO detector light collection and energy resolution that could be achieved by using these SiPMs.
△ Less
Submitted 13 March, 2019; v1 submitted 6 June, 2018;
originally announced June 2018.
-
nEXO Pre-Conceptual Design Report
Authors:
nEXO Collaboration,
S. Al Kharusi,
A. Alamre,
J. B. Albert,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
R. Conley
, et al. (149 additional authors not shown)
Abstract:
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of app…
▽ More
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of approximately $10^{28}$ years. This represents an improvement in sensitivity of about two orders of magnitude with respect to current results. Based on the experience gained from EXO-200 and the effectiveness of xenon purification techniques, we expect the background to be dominated by external sources of radiation. The sensitivity increase is, therefore, entirely derived from the increase of active mass in a monolithic and homogeneous detector, along with some technical advances perfected in the course of a dedicated R&D program. Hence the risk which is inherent to the construction of a large, ultra-low background detector is reduced, as the intrinsic radioactive contamination requirements are generally not beyond those demonstrated with the present generation $0νββ$ decay experiments. Indeed, most of the required materials have been already assayed or reasonable estimates of their properties are at hand. The details described herein represent the base design of the detector configuration as of early 2018. Where potential design improvements are possible, alternatives are discussed.
This design for nEXO presents a compelling path towards a next generation search for $0νββ$, with a substantial possibility to discover physics beyond the Standard Model.
△ Less
Submitted 13 August, 2018; v1 submitted 28 May, 2018;
originally announced May 2018.
-
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
P. C. F. Di Stefano,
T. Doughty,
E. Fascione
, et al. (77 additional authors not shown)
Abstract:
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensit…
▽ More
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensitivity to dark photons competitive with other leading approaches but using substantially less exposure (0.49 gram days). These results demonstrate the scientific potential of phonon-mediated semiconductor detectors that are sensitive to single electronic excitations.
△ Less
Submitted 22 December, 2020; v1 submitted 27 April, 2018;
originally announced April 2018.
-
Recent Results from the Majorana Demonstrator
Authors:
T Gilliss,
S I Alvis,
I J Arnquist,
F T Avignone III,
A S Barabash,
C J Barton,
F E Bertrand,
T Bode,
V Brudanin,
M Busch,
M Buuck,
T S Caldwell,
Y-D Chan,
C D Christofferson,
P -H Chu,
C Cuesta,
J A Detwiler,
C Dunagan,
Yu Efremenko,
H Ejiri,
S R Elliott,
G K Giovanetti,
M P Green,
J Gruszko,
I S Guinn
, et al. (43 additional authors not shown)
Abstract:
The MAJORANA Collaboration has completed construction and is now operating an array of high purity Ge detectors searching for neutrinoless double-beta decay ($0νββ$) in $^{76}$Ge. The array, known as the MAJORANA DEMONSTRATOR, is comprised of 44 kg of Ge detectors (30 kg enriched to 88% in $^{76}$Ge) installed in an ultra-low background compact shield at the Sanford Underground Research Facility i…
▽ More
The MAJORANA Collaboration has completed construction and is now operating an array of high purity Ge detectors searching for neutrinoless double-beta decay ($0νββ$) in $^{76}$Ge. The array, known as the MAJORANA DEMONSTRATOR, is comprised of 44 kg of Ge detectors (30 kg enriched to 88% in $^{76}$Ge) installed in an ultra-low background compact shield at the Sanford Underground Research Facility in Lead, South Dakota. The primary goal of the DEMONSTRATOR is to establish a low-background design that can be scaled to a next-generation tonne-scale experiment. This work reports initial background levels in the $0νββ$ region of interest. Also presented are recent physics results leveraging P-type point-contact detectors with sub-keV energy thresholds to search for physics beyond the Standard Model; first results from searches for bosonic dark matter, solar axions, Pauli exclusion principle violation, and electron decay have been published. Finally, this work discusses the proposed tonne-scale $^{76}$Ge $0νββ$ LEGEND experiment.
△ Less
Submitted 4 April, 2018;
originally announced April 2018.
-
The Majorana Demonstrator Status and Preliminary Results
Authors:
C. -H. Yu,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y. -D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. Green,
J. Gruszko
, et al. (41 additional authors not shown)
Abstract:
The Majorana Collaboration is using an array of high-purity Ge detectors to search for neutrinoless double-beta decay in 76Ge. Searches for neutrinoless double-beta decay are understood to be the only viable experimental method for testing the Majorana nature of the neutrino. Observation of this decay would imply violation of lepton number, that neutrinos are Majorana in nature, and provide inform…
▽ More
The Majorana Collaboration is using an array of high-purity Ge detectors to search for neutrinoless double-beta decay in 76Ge. Searches for neutrinoless double-beta decay are understood to be the only viable experimental method for testing the Majorana nature of the neutrino. Observation of this decay would imply violation of lepton number, that neutrinos are Majorana in nature, and provide information on the neutrino mass. The Majorana Demonstrator comprises 44.1 kg of p-type point-contact Ge detectors (29.7 kg enriched in 76Ge) surrounded by a low-background shield system. The experiment achieved a high efficiency of converting raw Ge material to detectors and an unprecedented detector energy resolution of 2.5 keV FWHM at Q$_{ββ}$. The Majorana collaboration began taking physics data in 2016. This paper summarizes key construction aspects of the Demonstrator and shows preliminary results from initial data.
△ Less
Submitted 29 March, 2018;
originally announced March 2018.
-
First Limit on the Direct Detection of Lightly Ionizing Particles for Electric Charge as Low as $e$/1000 with the \textsc{Majorana Demonstrator}
Authors:
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (39 additional authors not shown)
Abstract:
The \textsc{Majorana Demonstrator} is an ultra low-background experiment searching for neutrinoless double-beta decay in $^{76}$Ge. The heavily shielded array of germanium detectors, placed nearly a mile underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. Free, relativistic, lightly-ionizing particles with electrical charges…
▽ More
The \textsc{Majorana Demonstrator} is an ultra low-background experiment searching for neutrinoless double-beta decay in $^{76}$Ge. The heavily shielded array of germanium detectors, placed nearly a mile underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. Free, relativistic, lightly-ionizing particles with electrical charges less than $e$ are forbidden by the standard model but predicted by some of its extensions. If such particles exist, they might be detected in the \textsc{Majorana Demonstrator} by searching for multiple- detector events with individual-detector energy depositions down to 1 keV. This search is background free and no candidate events have been found in 285 days of data taking. New direct-detection limits are set for the flux of lightly ionizing particles for charges as low as $e$/1000.
△ Less
Submitted 29 May, 2018; v1 submitted 30 January, 2018;
originally announced January 2018.
-
Low Background Materials and Fabrication Techniques for Cables and Connectors in the Majorana Demonstrator
Authors:
M. Busch,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (45 additional authors not shown)
Abstract:
The MAJORANA Collaboration is searching for the neutrinoless double-beta decay of the nucleus Ge-76. The MAJORANA DEMONSTRATOR is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a tonne scale Ge-76-based search (the LEGEND collaboration). In the DEMONSTRATOR, germanium detectors operate in an ultra-pure vacuum cryostat at 80 K. One…
▽ More
The MAJORANA Collaboration is searching for the neutrinoless double-beta decay of the nucleus Ge-76. The MAJORANA DEMONSTRATOR is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a tonne scale Ge-76-based search (the LEGEND collaboration). In the DEMONSTRATOR, germanium detectors operate in an ultra-pure vacuum cryostat at 80 K. One special challenge of an ultra-pure environment is to develop reliable cables, connectors, and electronics that do not significantly contribute to the radioactive background of the experiment. This paper highlights the experimental requirements and how these requirements were met for the MAJORANA DEMONSTRATOR, including plans to upgrade the wiring for higher reliability in the summer of 2018. Also described are requirements for LEGEND R&D efforts underway to meet these additional requirements.
△ Less
Submitted 13 December, 2017;
originally announced December 2017.
-
Design improvements to cables and connectors in the Majorana Demonstrator
Authors:
C. R. Haufe,
A. L. Reine,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y. -D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss
, et al. (46 additional authors not shown)
Abstract:
The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850 level of the Sanford Underground Researc…
▽ More
The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850 level of the Sanford Underground Research Facility in Lead, South Dakota, USA. The Demonstrator uses custom high voltage cables to bias the detectors, as well as custom signal cables and connectors to read out the charge deposited at the point contact of each detector. These low-mass cables and connectors must meet stringent radiopurity requirements while being subjected to thermal and mechanical stress. A number of issues have been identified with the currently installed cables and connectors. An improved set of cables and connectors for the Majorana Demonstrator are being developed with the aim of increasing their overall reliability and connectivity. We will discuss some of the issues encountered with the current cables and connectors as well as our improved designs and their initial performance.
△ Less
Submitted 9 December, 2017;
originally announced December 2017.
-
Initial Results from the Majorana Demonstrator
Authors:
T. S. Caldwell,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
B. Bos,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti
, et al. (47 additional authors not shown)
Abstract:
The MAJORANA Collaboration has assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge with the goal of establishing the required background and scalability of a Ge-based next-generation ton-scale experiment. The MAJORANA DEMONSTRATOR consists of 44 kg of high-purity Ge (HPGe) detectors (30 kg enriched in $^{76}$Ge) with a low-noise p-type point con…
▽ More
The MAJORANA Collaboration has assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge with the goal of establishing the required background and scalability of a Ge-based next-generation ton-scale experiment. The MAJORANA DEMONSTRATOR consists of 44 kg of high-purity Ge (HPGe) detectors (30 kg enriched in $^{76}$Ge) with a low-noise p-type point contact (PPC) geometry. The detectors are split between two modules which are contained in a single lead and high-purity copper shield at the Sanford Underground Research Facility in Lead, South Dakota. Following a commissioning run that started in June 2015, the full detector array has been acquiring data since August 2016. We will discuss the status of the MAJORANA DEMONSTRATOR and initial results from the first physics run; including current background estimates, exotic low-energy physics searches, projections on the physics reach of the DEMONSTRATOR, and implications for a ton-scale Ge-based neutrinoless double-beta decay search.
△ Less
Submitted 29 November, 2017;
originally announced November 2017.
-
Data quality assurance for the MAJORANA DEMONSTRATOR
Authors:
J. Myslik,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P-H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti
, et al. (46 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and $^{76}$Ge-enriched germanium detectors totalling 44.1 kg, located at the 4850' level of the Sanford Underground Research Facility i…
▽ More
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and $^{76}$Ge-enriched germanium detectors totalling 44.1 kg, located at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. Any neutrinoless double-beta decay search requires a thorough understanding of the background and the signal energy spectra. The various techniques employed to ensure the integrity of the measured spectra are discussed. Data collection is monitored with a thorough set of checks, and subsequent careful analysis is performed to qualify the data for higher level physics analysis. Instrumental background events are tagged for removal, and problematic channels are removed from consideration as necessary.
△ Less
Submitted 28 November, 2017;
originally announced November 2017.
-
Contamination Control and Assay Results for the Majorana Demonstrator Ultra Clean Components
Authors:
C. D. Christofferson,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (45 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is a neutrinoless double beta decay experiment utilizing enriched Ge-76 detectors in 2 separate modules inside of a common solid shield at the Sanford Underground Research Facility. The DEMONSTRATOR has utilized world leading assay sensitivities to develop clean materials and processes for producing ultra-pure copper and plastic components. This experiment is now operatin…
▽ More
The MAJORANA DEMONSTRATOR is a neutrinoless double beta decay experiment utilizing enriched Ge-76 detectors in 2 separate modules inside of a common solid shield at the Sanford Underground Research Facility. The DEMONSTRATOR has utilized world leading assay sensitivities to develop clean materials and processes for producing ultra-pure copper and plastic components. This experiment is now operating, and initial data provide new insights into the success of cleaning and processing. Post production copper assays after the completion of Module 1 showed an increase in U and Th contamination in finished parts compared to starting bulk material. A revised cleaning method and additional round of surface contamination studies prior to Module 2 construction have provided evidence that more rigorous process control can reduce surface contamination. This article describes the assay results and discuss further studies to take advantage of assay capabilities for the purpose of maintaining ultra clean fabrication and process design.
△ Less
Submitted 28 November, 2017;
originally announced November 2017.
-
Progress Toward A $2νββ$ Measurement For The Majorana Demonstrator
Authors:
T Gilliss,
N Abgrall,
S I Alvis,
I J Arnquist,
F T Avignone III,
A S Barabash,
C J Barton,
F E Bertrand,
T Bode,
A W Bradley,
V Brudanin,
M Busch,
M Buuck,
T S Caldwell,
Y-D Chan,
C D Christofferson,
P -H Chu,
C Cuesta,
J A Detwiler,
C Dunagan,
Yu Efremenko,
H Ejiri,
S R Elliott,
G K Giovanetti,
M P Green
, et al. (46 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is a $^{76}$Ge-based neutrinoless double-beta decay ($0νββ$) experiment. Staged at the 4850 ft level of the Sanford Underground Research Facility, the DEMONSTRATOR operates an array of high-purity p-type point contact Ge detectors deployed within a graded passive shield and an active muon veto system. The present work concerns the two-neutrino double-beta decay mode (…
▽ More
The MAJORANA DEMONSTRATOR is a $^{76}$Ge-based neutrinoless double-beta decay ($0νββ$) experiment. Staged at the 4850 ft level of the Sanford Underground Research Facility, the DEMONSTRATOR operates an array of high-purity p-type point contact Ge detectors deployed within a graded passive shield and an active muon veto system. The present work concerns the two-neutrino double-beta decay mode ($2νββ$) of $^{76}$Ge. For Ge detectors, having superior energy resolution (0.1%), this mode poses negligible background to the $0νββ$ mode, even for a ton-scale experiment. However, the measurement of the $2νββ$ mode allows for careful systematics checks of active detector mass, enrichment fraction, and pulse shape discrimination cuts related to both the $0νββ$ and $2νββ$ decay modes. A precision measurement of the $2νββ$ shape also allows searches for spectral distortions, possibly indicative of new physics, including $0νββχ$. Work is underway to construct a full experimental background model enabling a Bayesian fit to the measured energy spectrum and extraction of a precise $2νββ$ spectrum and half-life.
△ Less
Submitted 20 November, 2017; v1 submitted 15 November, 2017;
originally announced November 2017.