-
Setups for eliminating static charge of the ATLAS18 strip sensors
Authors:
P. Federicova,
A. Affolder,
G. A. Beck,
A. J. Bevand,
Z. Chen,
I. Dawson,
A. Deshmukh,
A. Dowling,
V. Fadeyev,
J. Fernandez-Tejero,
A. Fournier,
N. Gonzalez,
L. Hommels,
C. Jessiman,
S. Kachiguin,
Ch. Klein,
T. Koffas,
J. Kroll,
V. Latonova,
M. Mikestikova,
P. S. Miyagawa,
S. O'Toole,
Q. Paddock,
L. Poley,
E. Staats
, et al. (5 additional authors not shown)
Abstract:
Construction of the new all-silicon Inner Tracker (ITk), developed by the ATLAS collaboration for the High Luminosity LHC, started in 2020 and is expected to continue till 2028. The ITk detector will include 18,000 highly segmented and radiation hard n+-in-p silicon strip sensors (ATLAS18), which are being manufactured by Hamamatsu Photonics. Mechanical and electrical characteristics of produced s…
▽ More
Construction of the new all-silicon Inner Tracker (ITk), developed by the ATLAS collaboration for the High Luminosity LHC, started in 2020 and is expected to continue till 2028. The ITk detector will include 18,000 highly segmented and radiation hard n+-in-p silicon strip sensors (ATLAS18), which are being manufactured by Hamamatsu Photonics. Mechanical and electrical characteristics of produced sensors are measured upon their delivery at several institutes participating in a complex Quality Control (QC) program. The QC tests performed on each individual sensor check the overall integrity and quality of the sensor. During the QC testing of production ATLAS18 strip sensors, an increased number of sensors that failed the electrical tests was observed. In particular, IV measurements indicated an early breakdown, while large areas containing several tens or hundreds of neighbouring strips with low interstrip isolation were identified by the Full strip tests, and leakage current instabilities were measured in a long-term leakage current stability setup. Moreover, a high surface electrostatic charge reaching a level of several hundreds of volts per inch was measured on a large number of sensors and on the plastic sheets, which mechanically protect these sensors in their paper envelopes. Accumulated data indicates a clear correlation between observed electrical failures and the sensor charge-up. To mitigate the above-described issues, the QC testing sites significantly modified the sensor handling procedures and introduced sensor recovery techniques based on irradiation of the sensor surface with UV light or application of intensive flows of ionized gas. In this presentation, we will describe the setups implemented by the QC testing sites to treat silicon strip sensors affected by static charge and evaluate the effectiveness of these setups in terms of improvement of the sensor performance.
△ Less
Submitted 18 December, 2023; v1 submitted 27 September, 2023;
originally announced September 2023.
-
Infrastructure for Detector Research and Development towards the International Linear Collider
Authors:
J. Aguilar,
P. Ambalathankandy,
T. Fiutowski,
M. Idzik,
Sz. Kulis,
D. Przyborowski,
K. Swientek,
A. Bamberger,
M. Köhli,
M. Lupberger,
U. Renz,
M. Schumacher,
Andreas Zwerger,
A. Calderone,
D. G. Cussans,
H. F. Heath,
S. Mandry,
R. F. Page,
J. J. Velthuis,
D. Attié,
D. Calvet,
P. Colas,
X. Coppolani,
Y. Degerli,
E. Delagnes
, et al. (252 additional authors not shown)
Abstract:
The EUDET-project was launched to create an infrastructure for developing and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infras…
▽ More
The EUDET-project was launched to create an infrastructure for developing and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.
△ Less
Submitted 23 January, 2012;
originally announced January 2012.
-
Development of a modular and scalable data acquisition system for calorimeters at a linear collider
Authors:
M. J. Goodrick,
L. B. A. Hommels,
R. Shaw,
D. R. Ward,
D. S. Bailey,
M. Kelly,
V. Boisvert,
B. Green,
M. G. Green,
A. Misiejuk,
T. Wu,
V. Bartsch,
M. Postranecky,
M. Warren,
M. Wing
Abstract:
A data acquisition (DAQ) system has been developed which will read out and control calorimeters serving as prototype systems for a future detector at an electron-positron linear collider. This is a modular, flexible and scalable DAQ system in which the hardware and signals are standards-based, using FPGAs and serial links. The idea of a backplaneless system was also pursued with a commercial devel…
▽ More
A data acquisition (DAQ) system has been developed which will read out and control calorimeters serving as prototype systems for a future detector at an electron-positron linear collider. This is a modular, flexible and scalable DAQ system in which the hardware and signals are standards-based, using FPGAs and serial links. The idea of a backplaneless system was also pursued with a commercial development board housed in a PC and a chain of concentrator cards between it and the detector forming the basis of the system. As well as describing the concept and performance of the system, its merits and disadvantages are discussed.
△ Less
Submitted 4 October, 2011; v1 submitted 29 June, 2011;
originally announced June 2011.