Precision measurement of the electron energy-loss function in tritium and deuterium gas for the KATRIN experiment
Authors:
M. Aker,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
B. Bieringer,
F. Block,
B. Bornschein,
L. Bornschein,
M. Böttcher,
T. Brunst,
T. S. Caldwell,
R. M. D. Carney,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Deffert,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun,
G. Drexlin,
F. Edzards,
K. Eitel,
E. Ellinger
, et al. (110 additional authors not shown)
Abstract:
The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $β$-decay endpoint region with a sensitivity on $m_ν$ of 0.2$\,$eV/c$^2$ (90% CL). For this purpose, the $β$-electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectromet…
▽ More
The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $β$-decay endpoint region with a sensitivity on $m_ν$ of 0.2$\,$eV/c$^2$ (90% CL). For this purpose, the $β$-electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectrometer are counted to obtain an integral spectrum around the endpoint energy of 18.6$\,$keV. A dominant systematic effect of the response of the experimental setup is the energy loss of $β$-electrons from elastic and inelastic scattering off tritium molecules within the source. We determined the \linebreak energy-loss function in-situ with a pulsed angular-selective and monoenergetic photoelectron source at various tritium-source densities. The data was recorded in integral and differential modes; the latter was achieved by using a novel time-of-flight technique.
We developed a semi-empirical parametrization for the energy-loss function for the scattering of 18.6-keV electrons from hydrogen isotopologs. This model was fit to measurement data with a 95% T$_2$ gas mixture at 30$\,$K, as used in the first KATRIN neutrino mass analyses, as well as a D$_2$ gas mixture of 96% purity used in KATRIN commissioning runs. The achieved precision on the energy-loss function has abated the corresponding uncertainty of $σ(m_ν^2)<10^{-2}\,\mathrm{eV}^2$ [arXiv:2101.05253] in the KATRIN neutrino-mass measurement to a subdominant level.
△ Less
Submitted 14 May, 2021;
originally announced May 2021.
-
The Design, Construction, and Commissioning of the KATRIN Experiment
Authors:
M. Aker,
K. Altenmüller,
J. F. Amsbaugh,
M. Arenz,
M. Babutzka,
J. Bast,
S. Bauer,
H. Bechtler,
M. Beck,
A. Beglarian,
J. Behrens,
B. Bender,
R. Berendes,
A. Berlev,
U. Besserer,
C. Bettin,
B. Bieringer,
K. Blaum,
F. Block,
S. Bobien,
J. Bohn,
K. Bokeloh,
H. Bolz,
B. Bornschein,
L. Bornschein
, et al. (204 additional authors not shown)
Abstract:
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [https://publikationen.bibliothek.kit.edu/270060419] to describe the hardware design and requirements to achieve our sensitivity goa…
▽ More
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [https://publikationen.bibliothek.kit.edu/270060419] to describe the hardware design and requirements to achieve our sensitivity goal of 0.2 eV at 90% C.L. on the neutrino mass. Since then there has been considerable progress, culminating in the publication of first neutrino mass results with the entire beamline operating [arXiv:1909.06048]. In this paper, we document the current state of all completed beamline components (as of the first neutrino mass measurement campaign), demonstrate our ability to reliably and stably control them over long times, and present details on their respective commissioning campaigns.
△ Less
Submitted 11 June, 2021; v1 submitted 5 March, 2021;
originally announced March 2021.
-
Suppression of Penning discharges between the KATRIN spectrometers
Authors:
M. Aker,
K. Altenmüller,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
T. S. Caldwell,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Deffert,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
K. Eitel
, et al. (129 additional authors not shown)
Abstract:
The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)neutrino mass with a sensitivity of $0.2\textrm{ eV/c}^2$ (90$\%$ C.L.) by precisely measuring the endpoint region of the tritium $β$-decay spectrum. It uses a tandem of electrostatic spectrometers working as MAC-E (magnetic adiabatic collimation combined with an electrostatic) filters. In the space b…
▽ More
The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)neutrino mass with a sensitivity of $0.2\textrm{ eV/c}^2$ (90$\%$ C.L.) by precisely measuring the endpoint region of the tritium $β$-decay spectrum. It uses a tandem of electrostatic spectrometers working as MAC-E (magnetic adiabatic collimation combined with an electrostatic) filters. In the space between the pre-spectrometer and the main spectrometer, an unavoidable Penning trap is created when the superconducting magnet between the two spectrometers, biased at their respective nominal potentials, is energized. The electrons accumulated in this trap can lead to discharges, which create additional background electrons and endanger the spectrometer and detector section downstream. To counteract this problem, "electron catchers" were installed in the beamline inside the magnet bore between the two spectrometers. These catchers can be moved across the magnetic-flux tube and intercept on a sub-ms time scale the stored electrons along their magnetron motion paths. In this paper, we report on the design and the successful commissioning of the electron catchers and present results on their efficiency in reducing the experimental background.
△ Less
Submitted 17 September, 2020; v1 submitted 21 November, 2019;
originally announced November 2019.
-
First operation of the KATRIN experiment with tritium
Authors:
M. Aker,
K. Altenmüller,
M. Arenz,
W. -J. Baek,
J. Barrett,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
T. S. Caldwell,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Deffert,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun
, et al. (146 additional authors not shown)
Abstract:
The determination of the neutrino mass is one of the major challenges in astroparticle physics today. Direct neutrino mass experiments, based solely on the kinematics of beta-decay, provide a largely model-independent probe to the neutrino mass scale. The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to directly measure the effective electron antineutrino mass with a sensitivity of 0.…
▽ More
The determination of the neutrino mass is one of the major challenges in astroparticle physics today. Direct neutrino mass experiments, based solely on the kinematics of beta-decay, provide a largely model-independent probe to the neutrino mass scale. The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to directly measure the effective electron antineutrino mass with a sensitivity of 0.2 eV 90% CL. In this work we report on the first operation of KATRIN with tritium which took place in 2018. During this commissioning phase of the tritium circulation system, excellent agreement of the theoretical prediction with the recorded spectra was found and stable conditions over a time period of 13 days could be established. These results are an essential prerequisite for the subsequent neutrino mass measurements with KATRIN in 2019.
△ Less
Submitted 13 September, 2019;
originally announced September 2019.
-
An improved upper limit on the neutrino mass from a direct kinematic method by KATRIN
Authors:
M. Aker,
K. Altenmüller,
M. Arenz,
M. Babutzka,
J. Barrett,
S. Bauer,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
K. Bokeloh,
J. Bonn,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
T. S. Caldwell,
L. La Cascio,
S. Chilingaryan,
W. Choi,
T. J. Corona
, et al. (184 additional authors not shown)
Abstract:
We report on the neutrino mass measurement result from the first four-week science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are energy analyzed by a high-resolution MAC-E filter. A fit of the integrated electron spectrum over a narrow interval around the kinematic endpoint at 18.57 keV gives an…
▽ More
We report on the neutrino mass measurement result from the first four-week science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are energy analyzed by a high-resolution MAC-E filter. A fit of the integrated electron spectrum over a narrow interval around the kinematic endpoint at 18.57 keV gives an effective neutrino mass square value of $(-1.0^{+0.9}_{-1.1})$ eV$^2$. From this we derive an upper limit of 1.1 eV (90$\%$ confidence level) on the absolute mass scale of neutrinos. This value coincides with the KATRIN sensitivity. It improves upon previous mass limits from kinematic measurements by almost a factor of two and provides model-independent input to cosmological studies of structure formation.
△ Less
Submitted 13 September, 2019;
originally announced September 2019.
-
High-resolution spectroscopy of gaseous $^\mathrm{83m}$Kr conversion electrons with the KATRIN experiment
Authors:
K. Altenmüller,
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards
, et al. (102 additional authors not shown)
Abstract:
In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous $^\mathrm{83m}$Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The results obtained in this calibration measurement represent a major commissioning milestone for the upcoming direct neutrino mass measurement with KATRIN. The successful campaign demonstr…
▽ More
In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous $^\mathrm{83m}$Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The results obtained in this calibration measurement represent a major commissioning milestone for the upcoming direct neutrino mass measurement with KATRIN. The successful campaign demonstrates the functionalities of the full KATRIN beamline. The KATRIN main spectrometer's excellent energy resolution of ~ 1 eV made it possible to determine the narrow K-32 and L$_3$-32 conversion electron line widths with an unprecedented precision of ~ 1 %.
△ Less
Submitted 18 March, 2019; v1 submitted 15 March, 2019;
originally announced March 2019.
-
Gamma-induced background in the KATRIN main spectrometer
Authors:
K. Altenmüller,
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
T. Bode,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
K. Eitel
, et al. (101 additional authors not shown)
Abstract:
The KATRIN experiment aims to measure the effective electron antineutrino mass $m_{\overlineν_e}$ with a sensitivity of 0.2 eV/c$^2$ using a gaseous tritium source combined with the MAC-E filter technique. A low background rate is crucial to achieving the proposed sensitivity, and dedicated measurements have been performed to study possible sources of background electrons. In this work, we test th…
▽ More
The KATRIN experiment aims to measure the effective electron antineutrino mass $m_{\overlineν_e}$ with a sensitivity of 0.2 eV/c$^2$ using a gaseous tritium source combined with the MAC-E filter technique. A low background rate is crucial to achieving the proposed sensitivity, and dedicated measurements have been performed to study possible sources of background electrons. In this work, we test the hypothesis that gamma radiation from external radioactive sources significantly increases the rate of background events created in the main spectrometer (MS) and observed in the focal-plane detector. Using detailed simulations of the gamma flux in the experimental hall, combined with a series of experimental tests that artificially increased or decreased the local gamma flux to the MS, we set an upper limit of 0.006 count/s (90% C.L.) from this mechanism. Our results indicate the effectiveness of the electrostatic and magnetic shielding used to block secondary electrons emitted from the inner surface of the MS.
△ Less
Submitted 10 July, 2019; v1 submitted 1 March, 2019;
originally announced March 2019.
-
Tritium beta decay with additional emission of new light bosons
Authors:
Giorgio Arcadi,
Julian Heeck,
Florian Heizmann,
Susanne Mertens,
Farinaldo S. Queiroz,
Werner Rodejohann,
Martin Slezák,
Kathrin Valerius
Abstract:
We consider tritium beta decay with additional emission of light pseudoscalar or vector bosons coupling to electrons or neutrinos. The electron energy spectrum for all cases is evaluated and shown to be well estimated by approximated analytical expressions. We give the statistical sensitivity of KATRIN to the mass and coupling of the new bosons, both in the standard setup of the experiment as well…
▽ More
We consider tritium beta decay with additional emission of light pseudoscalar or vector bosons coupling to electrons or neutrinos. The electron energy spectrum for all cases is evaluated and shown to be well estimated by approximated analytical expressions. We give the statistical sensitivity of KATRIN to the mass and coupling of the new bosons, both in the standard setup of the experiment as well as for future modifications in which the full energy spectrum of tritium decay is accessible.
△ Less
Submitted 8 November, 2018;
originally announced November 2018.
-
The KATRIN Superconducting Magnets: Overview and First Performance Results
Authors:
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel,
E. Ellinger,
R. Engel
, et al. (99 additional authors not shown)
Abstract:
The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6~T, adiabatically guide $β$-electrons from the source to the detector within a magnetic flux of 191~Tcm$^2$. A chain of ten single solenoid magnets and two larger superconducting magnet sy…
▽ More
The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6~T, adiabatically guide $β$-electrons from the source to the detector within a magnetic flux of 191~Tcm$^2$. A chain of ten single solenoid magnets and two larger superconducting magnet systems have been designed, constructed, and installed in the 70-m-long KATRIN beam line. The beam diameter for the magnetic flux varies from 0.064~m to 9~m, depending on the magnetic flux density along the beam line. Two transport and tritium pumping sections are assembled with chicane beam tubes to avoid direct "line-of-sight" molecular beaming effect of gaseous tritium molecules into the next beam sections. The sophisticated beam alignment has been successfully cross-checked by electron sources. In addition, magnet safety systems were developed to protect the complex magnet systems against coil quenches or other system failures. The main functionality of the magnet safety systems has been successfully tested with the two large magnet systems. The complete chain of the magnets was operated for several weeks at 70$\%$ of the design fields for the first test measurements with radioactive krypton gas. The stability of the magnetic fields of the source magnets has been shown to be better than 0.01$\%$ per month at 70$\%$ of the design fields. This paper gives an overview of the KATRIN superconducting magnets and reports on the first performance results of the magnets.
△ Less
Submitted 22 June, 2018; v1 submitted 21 June, 2018;
originally announced June 2018.
-
Muon-induced background in the KATRIN main spectrometer
Authors:
K. Altenmüller,
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
S. Bobien,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel
, et al. (109 additional authors not shown)
Abstract:
The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to make a model-independent determination of the effective electron antineutrino mass with a sensitivity of 0.2 eV/c$^{2}$. It investigates the kinematics of $β$-particles from tritium $β$-decay close to the endpoint of the energy spectrum. Because the KATRIN main spectrometer (MS) is located above ground, muon-induced backgrounds are of part…
▽ More
The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to make a model-independent determination of the effective electron antineutrino mass with a sensitivity of 0.2 eV/c$^{2}$. It investigates the kinematics of $β$-particles from tritium $β$-decay close to the endpoint of the energy spectrum. Because the KATRIN main spectrometer (MS) is located above ground, muon-induced backgrounds are of particular concern. Coincidence measurements with the MS and a scintillator-based muon detector system confirmed the model of secondary electron production by cosmic-ray muons inside the MS. Correlation measurements with the same setup showed that about $12\%$ of secondary electrons emitted from the inner surface are induced by cosmic-ray muons, with approximately one secondary electron produced for every 17 muon crossings. However, the magnetic and electrostatic shielding of the MS is able to efficiently suppress these electrons, and we find that muons are responsible for less than $17\%$ ($90\%$ confidence level) of the overall MS background.
△ Less
Submitted 13 December, 2018; v1 submitted 30 May, 2018;
originally announced May 2018.
-
Modelling of gas dynamical properties of the KATRIN tritium source and implications for the neutrino mass measurement
Authors:
L. Kuckert,
F. Heizmann,
G. Drexlin,
F. Glück,
M. Hötzel,
M. Kleesiek,
F. Sharipov,
K. Valerius
Abstract:
The KATRIN experiment aims to measure the effective mass of the electron antineutrino from the analysis of electron spectra stemming from the beta-decay of molecular tritium with a sensitivity of 200 meV. Therefore, a daily throughput of about 40 g of gaseous tritium is circulated in a windowless source section. An accurate description of the gas flow through this section is of fundamental importa…
▽ More
The KATRIN experiment aims to measure the effective mass of the electron antineutrino from the analysis of electron spectra stemming from the beta-decay of molecular tritium with a sensitivity of 200 meV. Therefore, a daily throughput of about 40 g of gaseous tritium is circulated in a windowless source section. An accurate description of the gas flow through this section is of fundamental importance for the neutrino mass measurement as it significantly influences the generation and transport of beta-decay electrons through the experimental setup. In this paper we present a comprehensive model consisting of calculations of rarefied gas flow through the different components of the source section ranging from viscous to free molecular flow. By connecting these simulations with a number of experimentally determined operational parameters the gas model can be refreshed regularly according to the measured operating conditions. In this work, measurement and modelling uncertainties are quantified with regard to their implications for the neutrino mass measurement. We find that the systematic uncertainties related to the description of gas flow are represented by $Δm_ν^2=(-3.06\pm 0.24)\cdot10^{-3}$ eV$^2$, and that the gas model is ready to be used in the analysis of upcoming KATRIN data.
△ Less
Submitted 29 June, 2018; v1 submitted 14 May, 2018;
originally announced May 2018.
-
Reduction of stored-particle background by a magnetic pulse method at the KATRIN experiment
Authors:
KATRIN Collaboration,
M. Arenz,
W. -J. Baek,
S. Bauer,
M. Beck,
A. Beglarian,
J. Behrens,
R. Berendes,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
W. Buglak,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba
, et al. (105 additional authors not shown)
Abstract:
The KATRIN experiment aims to determine the effective electron neutrino mass with a sensitivity of $0.2\,{\text{eV}/c^2}$ (90\% C.L.) by precision measurement of the shape of the tritium \textbeta-spectrum in the endpoint region. The energy analysis of the decay electrons is achieved by a MAC-E filter spectrometer. A common background source in this setup is the decay of short-lived isotopes, such…
▽ More
The KATRIN experiment aims to determine the effective electron neutrino mass with a sensitivity of $0.2\,{\text{eV}/c^2}$ (90\% C.L.) by precision measurement of the shape of the tritium \textbeta-spectrum in the endpoint region. The energy analysis of the decay electrons is achieved by a MAC-E filter spectrometer. A common background source in this setup is the decay of short-lived isotopes, such as $\textsuperscript{219}$Rn and $\textsuperscript{220}$Rn, in the spectrometer volume. Active and passive countermeasures have been implemented and tested at the KATRIN main spectrometer. One of these is the magnetic pulse method, which employs the existing air coil system to reduce the magnetic guiding field in the spectrometer on a short timescale in order to remove low- and high-energy stored electrons. Here we describe the working principle of this method and present results from commissioning measurements at the main spectrometer. Simulations with the particle-tracking software Kassiopeia were carried out to gain a detailed understanding of the electron storage conditions and removal processes.
△ Less
Submitted 3 May, 2018;
originally announced May 2018.
-
Calibration of high voltages at the ppm level by the difference of $^{83\mathrm{m}}$Kr conversion electron lines at the KATRIN experiment
Authors:
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel,
E. Ellinger,
R. Engel
, et al. (102 additional authors not shown)
Abstract:
The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at -18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage divid…
▽ More
The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at -18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage dividers required bringing the equipment to the specialised metrology laboratory. Here we present a new method based on measuring the energy difference of two $^{83\mathrm{m}}$Kr conversion electron lines with the KATRIN setup, which was demonstrated during KATRIN's commissioning measurements in July 2017. The measured scale factor $M=1972.449(10)$ of the high-voltage divider K35 is in agreement with the last PTB calibration four years ago. This result demonstrates the utility of the calibration method, as well as the long-term stability of the voltage divider.
△ Less
Submitted 15 May, 2018; v1 submitted 14 February, 2018;
originally announced February 2018.
-
First transmission of electrons and ions through the KATRIN beamline
Authors:
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel,
E. Ellinger,
R. Engel
, et al. (104 additional authors not shown)
Abstract:
The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a precise measurement of the endpoint spectrum of tritium beta decay. This work documents several KATRIN commissioning milestones: the complete assembly of the experimental beamline, the successful transmission of electrons fr…
▽ More
The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a precise measurement of the endpoint spectrum of tritium beta decay. This work documents several KATRIN commissioning milestones: the complete assembly of the experimental beamline, the successful transmission of electrons from three sources through the beamline to the primary detector, and tests of ion transport and retention. In the First Light commissioning campaign of Autumn 2016, photoelectrons were generated at the rear wall and ions were created by a dedicated ion source attached to the rear section; in July 2017, gaseous Kr-83m was injected into the KATRIN source section, and a condensed Kr-83m source was deployed in the transport section. In this paper we describe the technical details of the apparatus and the configuration for each measurement, and give first results on source and system performance. We have successfully achieved transmission from all four sources, established system stability, and characterized many aspects of the apparatus.
△ Less
Submitted 7 July, 2018; v1 submitted 12 February, 2018;
originally announced February 2018.
-
Statistical sensitivity on right-handed currents in presence of eV scale sterile neutrinos with KATRIN
Authors:
Nicholas M. N. Steinbrink,
Ferenc Glück,
Florian Heizmann,
Marco Kleesiek,
Kathrin Valerius,
Christian Weinheimer,
Steen Hannestad
Abstract:
The KATRIN experiment aims to determine the absolute neutrino mass by measuring the endpoint region of the tritium $β$ spectrum. As a large-scale experiment with a sharp energy resolution, high source luminosity and low background it may also be capable of testing certain theories of neutrino interactions beyond the standard model (SM). An example of a non-SM interaction are right-handed currents…
▽ More
The KATRIN experiment aims to determine the absolute neutrino mass by measuring the endpoint region of the tritium $β$ spectrum. As a large-scale experiment with a sharp energy resolution, high source luminosity and low background it may also be capable of testing certain theories of neutrino interactions beyond the standard model (SM). An example of a non-SM interaction are right-handed currents mediated by right-handed W bosons in the left-right symmetric model (LRSM). In this extension of the SM, an additional SU(2)$_\mathrm R$ symmetry in the high-energy limit is introduced, which naturally includes sterile neutrinos and predicts the seesaw mechanism. In tritium $β$ decay, this leads to an additional term from interference between left- and right-handed interactions, which enhances or suppresses certain regions near the endpoint of the beta spectrum. In this work, the sensitivity of KATRIN to right-handed currents is estimated for the scenario of a light sterile neutrino with a mass of some eV. This has been performed with a Bayesian analysis using Markov Chain Monte Carlo (MCMC). The simulations show that in principle KATRIN is able to set sterile neutrino mass-dependent limits on the interference strength. Thereby, the sensitivity is significantly increased if the $Q$ value of the $β$ decay can be sufficiently constrained. However, the sensitivity is not high enough to improve current upper limits from right-handed W boson searches at the LHC.
△ Less
Submitted 29 May, 2017; v1 submitted 22 March, 2017;
originally announced March 2017.
-
Kassiopeia: A Modern, Extensible C++ Particle Tracking Package
Authors:
Daniel Furse,
Stefan Groh,
Nikolaus Trost,
Martin Babutzka,
John P. Barrett,
Jan Behrens,
Nicholas Buzinksy,
Thomas Corona,
Sanshiro Enomoto,
Moritz Erhard,
Joseph A. Formaggio,
Ferenc Glück,
Fabian Harms,
Florian Heizmann,
Daniel Hilk,
Wolfgang Käfer,
Marco Kleesiek,
Benjamin Leiber,
Susanne Mertens,
Noah S. Oblath,
Pascal Renschler,
Johannes Schwarz,
Penny L. Slocum,
Nancy Wandkowsky,
Kevin Wierman
, et al. (1 additional authors not shown)
Abstract:
The Kassiopeia particle tracking framework is an object-oriented software package using modern C++ techniques, written originally to meet the needs of the KATRIN collaboration. Kassiopeia features a new algorithmic paradigm for particle tracking simulations which targets experiments containing complex geometries and electromagnetic fields, with high priority put on calculation efficiency, customiz…
▽ More
The Kassiopeia particle tracking framework is an object-oriented software package using modern C++ techniques, written originally to meet the needs of the KATRIN collaboration. Kassiopeia features a new algorithmic paradigm for particle tracking simulations which targets experiments containing complex geometries and electromagnetic fields, with high priority put on calculation efficiency, customizability, extensibility, and ease of use for novice programmers. To solve Kassiopeia's target physics problem the software is capable of simulating particle trajectories governed by arbitrarily complex differential equations of motion, continuous physics processes that may in part be modeled as terms perturbing that equation of motion, stochastic processes that occur in flight such as bulk scattering and decay, and stochastic surface processes occuring at interfaces, including transmission and reflection effects. This entire set of computations takes place against the backdrop of a rich geometry package which serves a variety of roles, including initialization of electromagnetic field simulations and the support of state-dependent algorithm-swapping and behavioral changes as a particle's state evolves. Thanks to the very general approach taken by Kassiopeia it can be used by other experiments facing similar challenges when calculating particle trajectories in electromagnetic fields. It is publicly available at https://github.com/KATRIN-Experiment/Kassiopeia
△ Less
Submitted 1 December, 2016;
originally announced December 2016.
-
Commissioning of the vacuum system of the KATRIN Main Spectrometer
Authors:
M. Arenz,
M. Babutzka,
M. Bahr,
J. P. Barrett,
S. Bauer,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
U. Besserer,
J. Blümer,
L. I. Bodine,
K. Bokeloh,
J. Bonn,
B. Bornschein,
L. Bornschein,
S. Büsch,
T. H. Burritt,
S. Chilingaryan,
T. J. Corona,
L. De Viveiros,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba
, et al. (125 additional authors not shown)
Abstract:
The KATRIN experiment will probe the neutrino mass by measuring the beta-electron energy spectrum near the endpoint of tritium beta-decay. An integral energy analysis will be performed by an electro-static spectrometer (Main Spectrometer), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m^3, and a complex inner electrode system with about 120000 individual parts. The strong m…
▽ More
The KATRIN experiment will probe the neutrino mass by measuring the beta-electron energy spectrum near the endpoint of tritium beta-decay. An integral energy analysis will be performed by an electro-static spectrometer (Main Spectrometer), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m^3, and a complex inner electrode system with about 120000 individual parts. The strong magnetic field that guides the beta-electrons is provided by super-conducting solenoids at both ends of the spectrometer. Its influence on turbo-molecular pumps and vacuum gauges had to be considered. A system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter strips has been deployed and was tested during the commissioning of the spectrometer. In this paper the configuration, the commissioning with bake-out at 300°C, and the performance of this system are presented in detail. The vacuum system has to maintain a pressure in the 10^{-11} mbar range. It is demonstrated that the performance of the system is already close to these stringent functional requirements for the KATRIN experiment, which will start at the end of 2016.
△ Less
Submitted 3 March, 2016;
originally announced March 2016.