High-rate, high-resolution single photon X-ray imaging: Medipix4, a large 4-side buttable pixel readout chip with high granularity and spectroscopic capabilities
Authors:
Viros Sriskaran,
Jerome Alozy,
Rafael Ballabriga,
Michael Campbell,
Pinelopi Christodoulou,
Erik Heijne,
Adil Koukab,
Thanushan Kugathasan,
Xavier Llopart,
Markus Piller,
Adithya Pulli,
Jean-Michel Sallese,
Lukas Tlustos
Abstract:
The Medipix4 chip is the latest member in the Medipix/Timepix family of hybrid pixel detector chips aimed at high-rate spectroscopic X-ray imaging using high-Z materials. It can be tiled on all 4 sides making it ideal for constructing large-area detectors with minimal dead area. The chip is designed to read out a sensor of 320 x 320 pixels with dimensions of 75 μm x 75 μm or 160 x 160 pixels with…
▽ More
The Medipix4 chip is the latest member in the Medipix/Timepix family of hybrid pixel detector chips aimed at high-rate spectroscopic X-ray imaging using high-Z materials. It can be tiled on all 4 sides making it ideal for constructing large-area detectors with minimal dead area. The chip is designed to read out a sensor of 320 x 320 pixels with dimensions of 75 μm x 75 μm or 160 x 160 pixels with dimensions of 150 μm x 150 μm. The readout architecture features energy binning of the single photons, which includes charge sharing correction for hits with energy spread over adjacent pixels. This paper presents the specifications, architecture, and circuit implementation of the chip, along with the first electrical measurements.
△ Less
Submitted 21 November, 2023; v1 submitted 16 October, 2023;
originally announced October 2023.
-
Identification of particles with Lorentz factor up to $10^{4}$ with Transition Radiation Detectors based on micro-strip silicon detectors
Authors:
J. Alozy,
N. Belyaev,
M. Campbell,
M. Cherry,
F. Dachs,
S. Doronin,
K. Filippov,
P. Fusco,
F. Gargano,
E. Heijne,
S. Konovalov,
D. Krasnopevtsev,
X. Llopart,
F. Loparco,
V. Mascagna,
M. N. Mazziotta,
H. Pernegger,
D. Ponomarenko,
M. Prest,
D. Pyatiizbyantseva,
R. Radomskii,
C. Rembser,
A. Romaniouk,
A. A. Savchenko,
D. Schaefer
, et al. (17 additional authors not shown)
Abstract:
This work is dedicated to the study of a technique for hadron identification in the TeV momentum range, based on the simultaneous measurement of the energies and of the emission angles of the Transition Radiation (TR) X-rays with respect to the radiating particles. A detector setup has been built and tested with particles in a wide range of Lorentz factors (from about $10^3$ to about…
▽ More
This work is dedicated to the study of a technique for hadron identification in the TeV momentum range, based on the simultaneous measurement of the energies and of the emission angles of the Transition Radiation (TR) X-rays with respect to the radiating particles. A detector setup has been built and tested with particles in a wide range of Lorentz factors (from about $10^3$ to about $4 \times 10^4$ crossing different types of radiators. The measured double-differential (in energy and angle) spectra of the TR photons are in a reasonably good agreement with TR simulation predictions.
△ Less
Submitted 22 February, 2019; v1 submitted 31 January, 2019;
originally announced January 2019.
-
Precision Luminosity of LHC Proton-Proton Collisions at 13 TeV Using Hit-Counting with TPX Pixel Devices
Authors:
Andre Sopczak,
Babar Ali,
Thanawat Asawatavonvanich,
Jakub Begera,
Benedikt Bergmann,
Thomas Billoud,
Petr Burian,
Ivan Caicedo,
Davide Caforio,
Erik Heijne,
Josef Janecek,
Claude Leroy,
Petr Manek,
Kazuya Mochizuki,
Yesid Mora,
Josef Pacik,
Costa Papadatos,
Michal Platkevic,
Stepan Polansky,
Stanislav Pospisil,
Michal Suk,
Zdenek Svoboda
Abstract:
A network of Timepix (TPX) devices installed in the ATLAS cavern measures the LHC luminosity as a function of time as a stand-alone system. The data were recorded from 13 TeV proton-proton collisions in 2015. Using two TPX devices, the number of hits created by particles passing the pixel matrices was counted. A van der Meer scan of the LHC beams was analysed using bunch-integrated luminosity aver…
▽ More
A network of Timepix (TPX) devices installed in the ATLAS cavern measures the LHC luminosity as a function of time as a stand-alone system. The data were recorded from 13 TeV proton-proton collisions in 2015. Using two TPX devices, the number of hits created by particles passing the pixel matrices was counted. A van der Meer scan of the LHC beams was analysed using bunch-integrated luminosity averages over the different bunch profiles for an approximate absolute luminosity normalization. It is demonstrated that the TPX network has the capability to measure the reduction of LHC luminosity with precision. Comparative studies were performed among four sensors (two sensors in each TPX device) and the relative short-term precision of the luminosity measurement was determined to be 0.1% for 10 s time intervals. The internal long-term time stability of the measurements was below 0.5% for the data-taking period.
△ Less
Submitted 2 February, 2017;
originally announced February 2017.
-
MPX Detectors as LHC Luminosity Monitor
Authors:
Andre Sopczak,
Babar Ali,
Nedaa Asbah,
Benedikt Bergmann,
Khaled Bekhouche,
Davide Caforio,
Michael Campbell,
Erik Heijne,
Claude Leroy,
Anna Lipniacka,
Marzio Nessi,
Stanislav Pospisil,
Frank Seifert,
Jaroslav Solc,
Paul Soueid,
Michal Suk,
Daniel Turecek,
Zdenek Vykydal
Abstract:
A network of 16 Medipix-2 (MPX) silicon pixel devices was installed in the ATLAS detector cavern at CERN. It was designed to measure the composition and spectral characteristics of the radiation field in the ATLAS experiment and its surroundings. This study demonstrates that the MPX network can also be used as a self-sufficient luminosity monitoring system. The MPX detectors collect data independe…
▽ More
A network of 16 Medipix-2 (MPX) silicon pixel devices was installed in the ATLAS detector cavern at CERN. It was designed to measure the composition and spectral characteristics of the radiation field in the ATLAS experiment and its surroundings. This study demonstrates that the MPX network can also be used as a self-sufficient luminosity monitoring system. The MPX detectors collect data independently of the ATLAS data-recording chain, and thus they provide independent measurements of the bunch-integrated ATLAS/LHC luminosity. In particular, the MPX detectors located close enough to the primary interaction point are used to perform van der Meer calibration scans with high precision. Results from the luminosity monitoring are presented for 2012 data taken at sqrt(s) = 8 TeV proton-proton collisions. The characteristics of the LHC luminosity reduction rate are studied and the effects of beam-beam (burn-off) and beam-gas (single bunch) interactions are evaluated. The systematic variations observed in the MPX luminosity measurements are below 0.3% for one minute intervals.
△ Less
Submitted 25 December, 2015;
originally announced December 2015.
-
Charged Particle Tracking with the Timepix ASIC
Authors:
Kazuyoshi Akiba,
Marina Artuso,
Ryan Badman,
Alessandra Borgia,
Richard Bates,
Florian Bayer,
Martin van Beuzekom,
Jan Buytaert,
Enric Cabruja,
Michael Campbell,
Paula Collins,
Michael Crossley,
Raphael Dumps,
Lars Eklund,
Daniel Esperante,
Celeste Fleta,
Abraham Gallas,
Miriam Gandelman,
Justin Garofoli,
Marco Gersabeck,
Vladimir V. Gligorov,
Hamish Gordon,
Erik H. M. Heijne,
Veerle Heijne,
Daniel Hynds
, et al. (17 additional authors not shown)
Abstract:
A prototype particle tracking telescope has been constructed using Timepix and Medipix ASIC hybrid pixel assemblies as the six sensing planes. Each telescope plane consisted of one 1.4 cm2 assembly, providing a 256x256 array of 55 micron square pixels. The telescope achieved a pointing resolution of 2.3 micron at the position of the device under test. During a beam test in 2009 the telescope was u…
▽ More
A prototype particle tracking telescope has been constructed using Timepix and Medipix ASIC hybrid pixel assemblies as the six sensing planes. Each telescope plane consisted of one 1.4 cm2 assembly, providing a 256x256 array of 55 micron square pixels. The telescope achieved a pointing resolution of 2.3 micron at the position of the device under test. During a beam test in 2009 the telescope was used to evaluate in detail the performance of two Timepix hybrid pixel assemblies; a standard planar 300 micron thick sensor, and 285 micron thick double sided 3D sensor. This paper describes a detailed charge calibration study of the pixel devices, which allows the true charge to be extracted, and reports on measurements of the charge collection characteristics and Landau distributions. The planar sensor achieved a best resolution of 4.0 micron for angled tracks, and resolutions of between 4.4 and 11 micron for perpendicular tracks, depending on the applied bias voltage. The double sided 3D sensor, which has significantly less charge sharing, was found to have an optimal resolution of 9.0 micron for angled tracks, and a resolution of 16.0 micron for perpendicular tracks. Based on these studies it is concluded that the Timepix ASIC shows an excellent performance when used as a device for charged particle tracking.
△ Less
Submitted 14 June, 2011; v1 submitted 14 March, 2011;
originally announced March 2011.
-
The detection of single electrons by means of a Micromegas-covered MediPix2 pixel CMOS readout circuit
Authors:
M. Campbell,
M. Chefdeville,
P. Colas,
A. P. Colijn,
A. Fornaini,
Y. Giomataris,
H. van der Graaf,
E. H. M Heijne,
P. Kluit,
X. Llopart,
J. Schmitz,
J. Timmermans,
J. L. Visschers
Abstract:
A small drift chamber was read out by means of a MediPix2 readout chip as direct anode. A Micromegas foil was placed 50 $μ$m above the chip, and electron multiplication occurred in the gap. With a He/Isobutane 80/20 mixture, gas multiplication factors up to tens of thousands were achieved, resulting in an efficiency for detecting single electrons of better than 90% . We recorded many frames cont…
▽ More
A small drift chamber was read out by means of a MediPix2 readout chip as direct anode. A Micromegas foil was placed 50 $μ$m above the chip, and electron multiplication occurred in the gap. With a He/Isobutane 80/20 mixture, gas multiplication factors up to tens of thousands were achieved, resulting in an efficiency for detecting single electrons of better than 90% . We recorded many frames containing 2D images with tracks from cosmic muons. Along these tracks, electron clusters were observed, as well as delta-rays.
△ Less
Submitted 9 September, 2004;
originally announced September 2004.
-
X-ray Imaging Using a Hybrid Photon Counting GaAs Pixel Detector
Authors:
C. Schwarz,
M. Campbell,
R. Goeppert,
E. H. M. Heijne,
J. Ludwig,
G. Meddeler,
B. Mikulec,
E. Pernigotti,
M. Rogalla,
K. Runge,
A. Soldner-Rembold,
K. M. Smith,
W. Snoeys,
J. Watt
Abstract:
The performance of hybrid GaAs pixel detectors as X-ray imaging sensors were investigated at room temperature. These hybrids consist of 300 mu-m thick GaAs pixel detectors, flip-chip bonded to a CMOS Single Photon Counting Chip (PCC). This chip consists of a matrix of 64 x 64 identical square pixels (170 mu-m x 170 mu-m) and covers a total area of 1.2 cm**2. The electronics in each cell comprise…
▽ More
The performance of hybrid GaAs pixel detectors as X-ray imaging sensors were investigated at room temperature. These hybrids consist of 300 mu-m thick GaAs pixel detectors, flip-chip bonded to a CMOS Single Photon Counting Chip (PCC). This chip consists of a matrix of 64 x 64 identical square pixels (170 mu-m x 170 mu-m) and covers a total area of 1.2 cm**2. The electronics in each cell comprises a preamplifier, a discriminator with a 3-bit threshold adjust and a 15-bit counter. The detector is realized by an array of Schottky diodes processed on semi-insulating LEC-GaAs bulk material. An IV-charcteristic and a detector bias voltage scan showed that the detector can be operated with voltages around 200 V. Images of various objects were taken by using a standard X-ray tube for dental diagnostics. The signal to noise ratio (SNR) was also determined. The applications of these imaging systems range from medical applications like digital mammography or dental X-ray diagnostics to non destructive material testing (NDT). Because of the separation of detector and readout chip, different materials can be investigated and compared.
△ Less
Submitted 21 December, 1998;
originally announced December 1998.