-
Convolutional neural network approach to ion Coulomb crystal image analysis
Authors:
James Allsopp,
Jake Diprose,
Brianna R. Heazlewood,
Chase Zagorec-Marks,
H. J. Lewandowski,
Lorenzo S. Petralia,
Timothy P. Softley
Abstract:
This paper reports on the use of a convolutional neural network (CNN) methodology to analyse fluorescence images of calcium-ion Coulomb crystals in the gas phase. A transfer-learning approach is adopted using the publicly available RESNET50 model. It is demonstrated that by training the neural network on around 500,000 simulated images, we are able to determine ion-numbers not only for a verificat…
▽ More
This paper reports on the use of a convolutional neural network (CNN) methodology to analyse fluorescence images of calcium-ion Coulomb crystals in the gas phase. A transfer-learning approach is adopted using the publicly available RESNET50 model. It is demonstrated that by training the neural network on around 500,000 simulated images, we are able to determine ion-numbers not only for a verification set of 100,000 simulated images, but also for experimental calcium-ion images from two different laboratories using a wide range of ion-trap parameters. Absolute ion numbers in the crystal were determined for the experimental data with a percentage error of approximately 10%. This analysis can be performed in a few seconds for an individual crystal image, and therefore the method enables the objective, and efficient, analysis of such images in real time, thereby facilitating time-dependent kinetic measurements on ion-molecule chemistry. The approach adopted also shows promising performance for identifying Ca+ ion numbers in images of mixed-species crystals.
△ Less
Submitted 24 March, 2025;
originally announced March 2025.
-
Simulating rotationally inelastic collisions using a Direct Simulation Monte Carlo method
Authors:
O. Schullian,
J. Loreau,
N. Vaeck,
A. van der Avoird,
B. R. Heazlewood,
C. J. Rennick,
T. P. Softley
Abstract:
A new approach to simulating rotational cooling using a direct simulation Monte Carlo (DSMC) method is described and applied to the rotational cooling of ammonia seeded into a helium supersonic jet. The method makes use of ab initio rotational state changing cross sections calculated as a function of collision energy. Each particle in the DSMC simulations is labelled with a vector of rotational po…
▽ More
A new approach to simulating rotational cooling using a direct simulation Monte Carlo (DSMC) method is described and applied to the rotational cooling of ammonia seeded into a helium supersonic jet. The method makes use of ab initio rotational state changing cross sections calculated as a function of collision energy. Each particle in the DSMC simulations is labelled with a vector of rotational populations that evolves with time. Transfer of energy into translation is calculated from the mean energy transfer for this population at the specified collision energy. The simulations are compared with a continuum model for the on-axis density, temperature and velocity; rotational temperature as a function of distance from the nozzle is in accord with expectations from experimental measurements. The method could be applied to other types of gas mixture dynamics under non-uniform conditions, such as buffer gas cooling of NH$_3$ by He.
△ Less
Submitted 24 November, 2015;
originally announced November 2015.
-
Coulomb crystal mass spectrometry in a digital ion trap
Authors:
Nabanita Deb,
Laura L. Pollum,
Alexander D. Smith,
Matthias Keller,
Christopher J. Rennick,
Brianna R. Heazlewood,
Timothy P. Softley
Abstract:
We present a mass spectrometric technique for identifying the masses and relative abundances of Coulomb-crystallized ions held in a linear Paul trap. A digital radiofrequency waveform is employed to generate the trapping potential, as this can be cleanly switched off, and static dipolar fields subsequently applied to the trap electrodes for ion ejection. Excellent detection efficiency is demonstra…
▽ More
We present a mass spectrometric technique for identifying the masses and relative abundances of Coulomb-crystallized ions held in a linear Paul trap. A digital radiofrequency waveform is employed to generate the trapping potential, as this can be cleanly switched off, and static dipolar fields subsequently applied to the trap electrodes for ion ejection. Excellent detection efficiency is demonstrated for Ca+ and CaF+ ions from bi-component Ca+/CaF+ Coulomb crystals prepared by reaction of Ca+ with CH3F. A quantitative linear relationship is observed between ion number and the corresponding integrated TOF peak, independent of the ionic species. The technique is applicable to a diverse range of multi-component Coulomb crystals - demonstrated here for Ca+/NH3+/NH4+ and Ca+/CaOH+/CaOD+ crystals - and will facilitate the measurement of ion-molecule reaction rates and branching ratios in complicated reaction systems.
△ Less
Submitted 9 January, 2015;
originally announced January 2015.