-
On the initiation of spiral waves in excitable media
Authors:
S. P. Hastings,
M. M Sussman
Abstract:
Excitable media are systems which are at rest in the absence of external input but which respond to a sufficiently strong stimulus by sending a wave of "excitation" across the medium. Examples include cardiac and cortical tissue, and in each of these examples rotating spiral waves have been observed and associated with abnormalities. How such waves are initiated is not well understood. In this num…
▽ More
Excitable media are systems which are at rest in the absence of external input but which respond to a sufficiently strong stimulus by sending a wave of "excitation" across the medium. Examples include cardiac and cortical tissue, and in each of these examples rotating spiral waves have been observed and associated with abnormalities. How such waves are initiated is not well understood. In this numerical study of a standard mathematical model of excitable media, we obtain spirals and other oscillatory patterns by a method, simple in design, which had previously been ruled out. We analyze the early stages of this process and show that long term stable oscillatory behavior, including spiral waves, can start with very simple initial conditions, such as two small spots of excitation, and no subsequent input. Thus, there are no refractory cells in the initial condition. For this model, even random spots of stimulation result in periodic rotating patterns relatively often, leading us to suggest that this could happen in living tissue.
△ Less
Submitted 30 December, 2020; v1 submitted 7 May, 2020;
originally announced May 2020.
-
Perturbed Field Ionization for Improved State Selectivity
Authors:
Vincent C. Gregoric,
Jason J. Bennett,
Bianca R. Gualtieri,
Hannah P. Hastings,
Ankitha Kannad,
Zhimin Cheryl Liu,
Maia R. Rabinowitz,
Zoe A. Rowley,
Miao Wang,
Lauren Yoast,
Thomas J. Carroll,
Michael W. Noel
Abstract:
Selective field ionization is used to determine the state or distribution of states to which a Rydberg atom is excited. By evolving a small perturbation to the ramped electric field using a genetic algorithm, the shape of the time-resolved ionization signal can be controlled. This allows for separation of signals from pairs of states that would be indistinguishable with unperturbed selective field…
▽ More
Selective field ionization is used to determine the state or distribution of states to which a Rydberg atom is excited. By evolving a small perturbation to the ramped electric field using a genetic algorithm, the shape of the time-resolved ionization signal can be controlled. This allows for separation of signals from pairs of states that would be indistinguishable with unperturbed selective field ionization. Measurements and calculations are presented that demonstrate this technique and shed light on how the perturbation directs the pathway of the electron to ionization. Pseudocode for the genetic algorithm is provided. Using the improved resolution afforded by this technique, quantitative measurements of the $36p_{3/2}+36p_{3/2}\rightarrow 36s_{1/2}+37s_{1/2}$ dipole-dipole interaction are made.
△ Less
Submitted 20 November, 2019; v1 submitted 23 August, 2019;
originally announced August 2019.
-
Miniaturized atmospheric ionization detector
Authors:
Karen Aplin,
Aaron Briggs,
Adam Baird,
Peter Hastings,
R. Giles Harrison,
Graeme Marlton
Abstract:
A small scintillator-based detector for atmospheric ionization measurements has been developed, partly in response to a need for better ionization data in the weather-forming regions of the atmosphere and partly with the intention of producing a commercially available device. The device can measure both the count rate and energy of atmospheric ionizing radiation. Here we report results of a test f…
▽ More
A small scintillator-based detector for atmospheric ionization measurements has been developed, partly in response to a need for better ionization data in the weather-forming regions of the atmosphere and partly with the intention of producing a commercially available device. The device can measure both the count rate and energy of atmospheric ionizing radiation. Here we report results of a test flight over the UK in December 2017 where the detector was flown with two Geiger counters on a meteorological radiosonde. The count rate profile with height was consistent both with the Geigers and with previous work. The energy of incoming ionizing radiation increased substantially with altitude.
△ Less
Submitted 20 April, 2018;
originally announced April 2018.
-
The Mid-Infrared Instrument for the James Webb Space Telescope, VI: The Medium Resolution Spectrometer
Authors:
Martyn Wells,
J. -W. Pel,
Alistair Glasse,
G. S. Wright,
Gabby Aitink-Kroes,
Ruyman Azzollini,
Steven Beard,
B. R. Brandl,
Angus Gallie,
V. C. Geers,
A. M. Glauser,
Peter Hastings,
Th. Henning,
Rieks Jager,
K. Justtanont,
Bob Kruizinga,
Fred Lahuis,
David Lee,
I. Martinez-Delgado,
J. R. Martinez-Galarza,
M. Meijers,
Jane E. Morrison,
Friedrich Mueller,
Thodori Nakos,
Brian O'Sullivan
, et al. (13 additional authors not shown)
Abstract:
We describe the design and performance of the Medium Resolution Spectrometer (MRS) for the JWST-MIRI instrument. The MRS incorporates four coaxial spectral channels in a compact opto-mechanical layout that generates spectral images over fields of view up to 7.7 X 7.7 arcseconds in extent and at spectral resolving powers ranging from 1,300 to 3,700. Each channel includes an all-reflective integral…
▽ More
We describe the design and performance of the Medium Resolution Spectrometer (MRS) for the JWST-MIRI instrument. The MRS incorporates four coaxial spectral channels in a compact opto-mechanical layout that generates spectral images over fields of view up to 7.7 X 7.7 arcseconds in extent and at spectral resolving powers ranging from 1,300 to 3,700. Each channel includes an all-reflective integral field unit (IFU): an 'image slicer' that reformats the input field for presentation to a grating spectrometer. Two 1024 X 1024 focal plane arrays record the output spectral images with an instantaneous spectral coverage of approximately one third of the full wavelength range of each channel. The full 5 to 28.5 micron spectrum is then obtained by making three exposures using gratings and pass-band-determining filters that are selected using just two three-position mechanisms. The expected on-orbit optical performance is presented, based on testing of the MIRI Flight Model and including spectral and spatial coverage and resolution. The point spread function of the reconstructed images is shown to be diffraction limited and the optical transmission is shown to be consistent with the design expectations.
△ Less
Submitted 12 August, 2015;
originally announced August 2015.
-
The Mid-Infrared Instrument for JWST, II: Design and Build
Authors:
G. S. Wright,
David Wright,
G. B. Goodson,
G. H. Rieke,
Gabby Aitink-Kroes,
J. Amiaux,
Ana Aricha-Yanguas,
Ruyman Azzolini,
Kimberly Banks,
D. Barrado-Navascues,
T. Belenguer-Davila,
J. A. D. L. Bloemmart,
Patrice Bouchet,
B. R. Brandl,
L. Colina,
Ors Detre,
Eva Diaz-Catala,
Paul Eccleston,
Scott D. Friedman,
Macarena Garcia-Marin,
Manuel Guedel,
Alistair Glasse,
Adrian M. Glauser,
T. P. Greene,
Uli Groezinger
, et al. (48 additional authors not shown)
Abstract:
The Mid-InfraRed Instrument (MIRI) on the James Webb Space Telescope (JWST) provides measurements over the wavelength range 5 to 28.5 microns. MIRI has, within a single 'package', four key scientific functions: photometric imaging, coronagraphy, single-source low-spectral resolving power (R ~ 100) spectroscopy, and medium-resolving power (R ~ 1500 to 3500) integral field spectroscopy. An associate…
▽ More
The Mid-InfraRed Instrument (MIRI) on the James Webb Space Telescope (JWST) provides measurements over the wavelength range 5 to 28.5 microns. MIRI has, within a single 'package', four key scientific functions: photometric imaging, coronagraphy, single-source low-spectral resolving power (R ~ 100) spectroscopy, and medium-resolving power (R ~ 1500 to 3500) integral field spectroscopy. An associated cooler system maintains MIRI at its operating temperature of < 6.7 K. This paper describes the driving principles behind the design of MIRI, the primary design parameters, and their realization in terms of the 'as-built' instrument. It also describes the test program that led to delivery of the tested and calibrated Flight Model to NASA in 2012, and the confirmation after delivery of the key interface requirements.
△ Less
Submitted 10 August, 2015;
originally announced August 2015.
-
MOONS: a Multi-Object Optical and Near-infrared Spectrograph for the VLT
Authors:
M. Cirasuolo,
J. Afonso,
R. Bender,
P. Bonifacio,
C. Evans,
L. Kaper,
E. Oliva,
L. Vanzi,
M. Abreu,
E. Atad-Ettedgui,
C. Babusiaux,
F. Bauer,
P. Best,
N. Bezawada,
I. Bryson,
A. Cabral,
K. Caputi,
M. Centrone,
F. Chemla,
A. Cimatti,
M-R. Cioni,
G. Clementini,
J. Coelho,
E. Daddi,
J. Dunlop
, et al. (55 additional authors not shown)
Abstract:
MOONS is a new conceptual design for a Multi-Object Optical and Near-infrared Spectrograph for the Very Large Telescope (VLT), selected by ESO for a Phase A study. The baseline design consists of 1000 fibers deployable over a field of view of 500 square arcmin, the largest patrol field offered by the Nasmyth focus at the VLT. The total wavelength coverage is 0.8um-1.8um and two resolution modes: m…
▽ More
MOONS is a new conceptual design for a Multi-Object Optical and Near-infrared Spectrograph for the Very Large Telescope (VLT), selected by ESO for a Phase A study. The baseline design consists of 1000 fibers deployable over a field of view of 500 square arcmin, the largest patrol field offered by the Nasmyth focus at the VLT. The total wavelength coverage is 0.8um-1.8um and two resolution modes: medium resolution and high resolution. In the medium resolution mode (R=4,000-6,000) the entire wavelength range 0.8um-1.8um is observed simultaneously, while the high resolution mode covers simultaneously three selected spectral regions: one around the CaII triplet (at R=8,000) to measure radial velocities, and two regions at R=20,000 one in the J-band and one in the H-band, for detailed measurements of chemical abundances. The grasp of the 8.2m Very Large Telescope (VLT) combined with the large multiplex and wavelength coverage of MOONS - extending into the near-IR - will provide the observational power necessary to study galaxy formation and evolution over the entire history of the Universe, from our Milky Way, through the redshift desert and up to the epoch of re-ionization at z>8-9. At the same time, the high spectral resolution mode will allow astronomers to study chemical abundances of stars in our Galaxy, in particular in the highly obscured regions of the Bulge, and provide the necessary follow-up of the Gaia mission. Such characteristics and versatility make MOONS the long-awaited workhorse near-IR MOS for the VLT, which will perfectly complement optical spectroscopy performed by FLAMES and VIMOS.
△ Less
Submitted 28 August, 2012;
originally announced August 2012.
-
Multi-Object Spectroscopy with the European ELT: Scientific synergies between EAGLE & EVE
Authors:
C. J. Evans,
B. Barbuy,
P. Bonifacio,
F. Chemla,
J. -G. Cuby,
G. B. Dalton,
B. Davies,
K. Disseau,
K. Dohlen,
H. Flores,
E. Gendron,
I. Guinouard,
F. Hammer,
P. Hastings,
D. Horville,
P. Jagourel,
L. Kaper,
P. Laporte,
D. Lee,
S. L. Morris,
T. Morris,
R. Myers,
R. Navarro,
P. Parr-Burman,
P. Petitjean
, et al. (7 additional authors not shown)
Abstract:
The EAGLE and EVE Phase A studies for instruments for the European Extremely Large Telescope (E-ELT) originated from related top-level scientific questions, but employed different (yet complementary) methods to deliver the required observations. We re-examine the motivations for a multi-object spectrograph (MOS) on the E-ELT and present a unified set of requirements for a versatile instrument. Suc…
▽ More
The EAGLE and EVE Phase A studies for instruments for the European Extremely Large Telescope (E-ELT) originated from related top-level scientific questions, but employed different (yet complementary) methods to deliver the required observations. We re-examine the motivations for a multi-object spectrograph (MOS) on the E-ELT and present a unified set of requirements for a versatile instrument. Such a MOS would exploit the excellent spatial resolution in the near-infrared envisaged for EAGLE, combined with aspects of the spectral coverage and large multiplex of EVE. We briefly discuss the top-level systems which could satisfy these requirements in a single instrument at one of the Nasmyth foci of the E-ELT.
△ Less
Submitted 3 July, 2012;
originally announced July 2012.
-
EAGLE ISS - A modular twin-channel integral-field near-IR spectrograph
Authors:
P. R. Hastings,
B. Stobie,
S. Vives,
P. Vola,
M. Wells,
C. J. Evans
Abstract:
The ISS (Integral-field Spectrograph System) has been designed as part of the EAGLE Phase A Instrument Study for the E-ELT. It consists of two input channels of 1.65x1.65 arcsec field-of-view, each reconfigured spatially by an image-slicing integral-field unit to feed a single near-IR spectrograph using cryogenic volume-phase-holographic (VPH) gratings to disperse the image spectrally. A 4k x 4k a…
▽ More
The ISS (Integral-field Spectrograph System) has been designed as part of the EAGLE Phase A Instrument Study for the E-ELT. It consists of two input channels of 1.65x1.65 arcsec field-of-view, each reconfigured spatially by an image-slicing integral-field unit to feed a single near-IR spectrograph using cryogenic volume-phase-holographic (VPH) gratings to disperse the image spectrally. A 4k x 4k array detector array records the dispersed images. The optical design employs anamorphic magnification, image slicing, VPH gratings scanned with a novel cryo-mechanism and a three-lens camera. The mechanical implementation features IFU optics in Zerodur, a modular bench structure and a number of high-precision cryo-mechanisms.
△ Less
Submitted 9 July, 2010;
originally announced July 2010.
-
The Herschel-SPIRE instrument and its in-flight performance
Authors:
M. J. Griffin,
A. Abergel,
A. Abreu,
P. A. R. Ade,
P. André,
J. -L. Augueres,
T. Babbedge,
Y. Bae,
T. Baillie,
J. -P. Baluteau,
M. J. Barlow,
G. Bendo,
D. Benielli,
J. J. Bock,
P. Bonhomme,
D. Brisbin,
C. Brockley-Blatt,
M. Caldwell,
C. Cara,
N. Castro-Rodriguez,
R. Cerulli,
P. Chanial,
S. Chen,
E. Clark,
D. L. Clements
, et al. (154 additional authors not shown)
Abstract:
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space Observatory`s submillimetre camera and spectrometer. It contains a three-band imaging photometer operating at 250, 350 and 500 microns, and an imaging Fourier Transform Spectrometer (FTS) which covers simultaneously its whole operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are arrays of feedhorn-c…
▽ More
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space Observatory`s submillimetre camera and spectrometer. It contains a three-band imaging photometer operating at 250, 350 and 500 microns, and an imaging Fourier Transform Spectrometer (FTS) which covers simultaneously its whole operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are arrays of feedhorn-coupled bolometers cooled to 0.3 K. The photometer has a field of view of 4' x 8', observed simultaneously in the three spectral bands. Its main operating mode is scan-mapping, whereby the field of view is scanned across the sky to achieve full spatial sampling and to cover large areas if desired. The spectrometer has an approximately circular field of view with a diameter of 2.6'. The spectral resolution can be adjusted between 1.2 and 25 GHz by changing the stroke length of the FTS scan mirror. Its main operating mode involves a fixed telescope pointing with multiple scans of the FTS mirror to acquire spectral data. For extended source measurements, multiple position offsets are implemented by means of an internal beam steering mirror to achieve the desired spatial sampling and by rastering of the telescope pointing to map areas larger than the field of view. The SPIRE instrument consists of a cold focal plane unit located inside the Herschel cryostat and warm electronics units, located on the spacecraft Service Module, for instrument control and data handling. Science data are transmitted to Earth with no on-board data compression, and processed by automatic pipelines to produce calibrated science products. The in-flight performance of the instrument matches or exceeds predictions based on pre-launch testing and modelling: the photometer sensitivity is comparable to or slightly better than estimated pre-launch, and the spectrometer sensitivity is also better by a factor of 1.5-2.
△ Less
Submitted 27 May, 2010;
originally announced May 2010.
-
HARP/ACSIS: A submillimetre spectral imaging system on the James Clerk Maxwell Telescope
Authors:
J. V. Buckle,
R. E. Hills,
H. Smith,
W. R. F. Dent,
G. Bell,
E. I. Curtis,
R. Dace,
H. Gibson,
S. F. Graves,
J. Leech,
J. S. Richer,
R. Williamson,
S. Withington,
G. Yassin,
R. Bennett,
P. Hastings,
I. Laidlaw,
J. F. Lightfoot,
T. Burgess,
P. E. Dewdney,
G. Hovey,
A. G. Willis,
R. Redman,
B. Wooff,
D. S. Berry
, et al. (13 additional authors not shown)
Abstract:
This paper describes a new Heterodyne Array Receiver Programme (HARP) and Auto-Correlation Spectral Imaging System (ACSIS) that have recently been installed and commissioned on the James Clerk Maxwell Telescope (JCMT). The 16-element focal-plane array receiver, operating in the submillimetre from 325 to 375 GHz, offers high (three-dimensional) mapping speeds, along with significant improvements…
▽ More
This paper describes a new Heterodyne Array Receiver Programme (HARP) and Auto-Correlation Spectral Imaging System (ACSIS) that have recently been installed and commissioned on the James Clerk Maxwell Telescope (JCMT). The 16-element focal-plane array receiver, operating in the submillimetre from 325 to 375 GHz, offers high (three-dimensional) mapping speeds, along with significant improvements over single-detector counterparts in calibration and image quality. Receiver temperatures are $\sim$120 K across the whole band and system temperatures of $\sim$300K are reached routinely under good weather conditions. The system includes a single-sideband filter so these are SSB figures. Used in conjunction with ACSIS, the system can produce large-scale maps rapidly, in one or more frequency settings, at high spatial and spectral resolution. Fully-sampled maps of size 1 square degree can be observed in under 1 hour.
The scientific need for array receivers arises from the requirement for programmes to study samples of objects of statistically significant size, in large-scale unbiased surveys of galactic and extra-galactic regions. Along with morphological information, the new spectral imaging system can be used to study the physical and chemical properties of regions of interest. Its three-dimensional imaging capabilities are critical for research into turbulence and dynamics. In addition, HARP/ACSIS will provide highly complementary science programmes to wide-field continuum studies, and produce the essential preparatory work for submillimetre interferometers such as the SMA and ALMA.
△ Less
Submitted 21 July, 2009;
originally announced July 2009.
-
An Elementary Approach to a Model Problem of Lagerstrom
Authors:
S. P. Hastings,
J. B. McLeod
Abstract:
The equation studied is u"+((n-1)/r)u'+epsilon u u'+ku'^{2}=0, with boundary conditions u(1)=0, u(infinity)=1. This model equation has been studied by many authors since it was introduced in the 1950s by P. A. Lagerstrom. We use an elementary approach to show that there is an infinite series solution which is uniformly convergent on 1<=r<infinity. The first few terms are easily derived, from whi…
▽ More
The equation studied is u"+((n-1)/r)u'+epsilon u u'+ku'^{2}=0, with boundary conditions u(1)=0, u(infinity)=1. This model equation has been studied by many authors since it was introduced in the 1950s by P. A. Lagerstrom. We use an elementary approach to show that there is an infinite series solution which is uniformly convergent on 1<=r<infinity. The first few terms are easily derived, from which one quickly deduces the inner and outer asymptotic expansions, with no matching procedure or a priori assumptions about the nature of the expansion. We also give a short and elementary existence and uniqueness proof which covers all epsilon > 0, k >= 0, and n >= 1.
△ Less
Submitted 26 November, 2008;
originally announced November 2008.
-
2.5 Dimensional Particle-in-Cell Simulations of Relativistic Plasma Collisions
Authors:
Orestes P. Hastings IV,
Edison Liang
Abstract:
We use electromagnetic Particle-in-Cell codes to investigate the two-stream instability and Weibel instability when two beams of plasma collide head-on relativistically. We compare the dissipation of kinetic energies in the two cases. We also study the evolution of the resultant electron energy distribution function produced by such dissipation.
We use electromagnetic Particle-in-Cell codes to investigate the two-stream instability and Weibel instability when two beams of plasma collide head-on relativistically. We compare the dissipation of kinetic energies in the two cases. We also study the evolution of the resultant electron energy distribution function produced by such dissipation.
△ Less
Submitted 7 March, 2008;
originally announced March 2008.
-
A multi-object, multi-field spectrometer and imager for a European ELT
Authors:
Chris Evans,
Colin Cunningham,
Eli Atad-Ettedgui,
Jeremy Allington-Smith,
Francois Assemat,
Gavin Dalton,
Peter Hastings,
Timothy Hawarden,
Isobel Hook,
Rob Ivison,
Simon Morris,
Suzanne Ramsay Howat,
Mel Strachan,
Stephen Todd
Abstract:
One of the highlights of the European ELT Science Case book is the study of resolved stellar populations, potentially out to the Virgo Cluster of galaxies. A European ELT would enable such studies in a wide range of unexplored distant environments, in terms of both galaxy morphology and metallicity. As part of a small study, a revised science case has been used to shape the conceptual design of…
▽ More
One of the highlights of the European ELT Science Case book is the study of resolved stellar populations, potentially out to the Virgo Cluster of galaxies. A European ELT would enable such studies in a wide range of unexplored distant environments, in terms of both galaxy morphology and metallicity. As part of a small study, a revised science case has been used to shape the conceptual design of a multi-object, multi-field spectrometer and imager (MOMSI). Here we present an overview of some key science drivers, and how to achieve these with elements such as multiplex, AO-correction, pick-off technology and spectral resolution.
△ Less
Submitted 19 May, 2006;
originally announced May 2006.
-
Multiple Integral Field Spectroscopy
Authors:
Gillian Wright,
Rob Ivison,
Peter Hastings,
Martyn Wells,
Ray Sharples,
Jeremy Allington-Smith,
Robert Content
Abstract:
Integral-field spectroscopy is the most effective method of exploiting the superb image quality of the ESO-VLT, allowing complex astrophysical processes to be probed on the angular scales currently accessible only for imaging data, but with the addition of information in the spectral dimension. We discuss science drivers and requirements for multiple deployable integral fields for spectroscopy i…
▽ More
Integral-field spectroscopy is the most effective method of exploiting the superb image quality of the ESO-VLT, allowing complex astrophysical processes to be probed on the angular scales currently accessible only for imaging data, but with the addition of information in the spectral dimension. We discuss science drivers and requirements for multiple deployable integral fields for spectroscopy in the near-infrared. We then describe a fully modular instrument concept which can achieve such a capability over a 5-10' field with up to 32 deployable integral fields, each fully cryogenic with 1-2.5 micron coverage at a spectral resolution of ~3000, each with a 4" x 4" field of view sampled at 0.2"/pixel to take advantage of the best K-band seeing.
△ Less
Submitted 15 February, 2002;
originally announced February 2002.
-
A shooting approach to layers and chaos for a forced Duffing equation
Authors:
SB. Ai,
S. Hastings
Abstract:
We study equilibrium solutions for the problem $u_t=ε^2 u_{xx} -u^3 +λu -cos(t)$,$u_x(0,t)=u_x(L,t)=0$. Using a shooting method we find solutions for all non-zero $ε.$ For small $ε$ we add to the solutions found by previous authors, especially Angennent, Mallet-Paret and Peletier, and Hale and Sakamoto, and also give new elementary ode proofs of their results. Among the new results is the existe…
▽ More
We study equilibrium solutions for the problem $u_t=ε^2 u_{xx} -u^3 +λu -cos(t)$,$u_x(0,t)=u_x(L,t)=0$. Using a shooting method we find solutions for all non-zero $ε.$ For small $ε$ we add to the solutions found by previous authors, especially Angennent, Mallet-Paret and Peletier, and Hale and Sakamoto, and also give new elementary ode proofs of their results. Among the new results is the existence of internal layer-type solutions. Considering the ode satisfied by equilibria, but on an infinite interval, we obtain chaos results for $λ\geq λ_{0}=\frac{3}{2^{2/3}}$ and $0<ε\leq {1/4}.$ We also consider the problem of bifurcation of solutions as $λ$ increases from $0.$
△ Less
Submitted 5 May, 2001;
originally announced May 2001.
-
On the global bifurcation diagram for the one-dimensional Ginzburg Landau model of superconductivity
Authors:
E. N. Dancer,
S. P. Hastings
Abstract:
Some new global results are given about solutions to the boundary value problem for the Euler-Lagrange equations for the Ginzburg-Landau model of a one-dimensional superconductor. The main advance is a proof that in some parameter range there is a branch of asymmetric solutions connecting the branch of symmetric solutions to the normal state. Also, simplified proofs are presented for some local…
▽ More
Some new global results are given about solutions to the boundary value problem for the Euler-Lagrange equations for the Ginzburg-Landau model of a one-dimensional superconductor. The main advance is a proof that in some parameter range there is a branch of asymmetric solutions connecting the branch of symmetric solutions to the normal state. Also, simplified proofs are presented for some local bifurcation results of Bolley and Helffer. These proofs require no detailed asymptotics for the solutions of the linear equations. Finally, an error in Odeh's work on this problem is discussed.
△ Less
Submitted 16 March, 1999;
originally announced March 1999.
-
There are Asymmetric Minimizers for the One-Dimensional Ginzburg-Landau Model of Superconductivity
Authors:
S. P. Hastings,
W. C. Troy
Abstract:
We study a boundary value problem associated with a system of two second order differential equations with cubic nonlinearity which model a film of superconductor material subjected to a tangential magnetic field. We show that for an appropriate range of parameters there are {\it asymmetric} solutions, and only trivial {\it symmetric} solutions. We then show that the associated energy function i…
▽ More
We study a boundary value problem associated with a system of two second order differential equations with cubic nonlinearity which model a film of superconductor material subjected to a tangential magnetic field. We show that for an appropriate range of parameters there are {\it asymmetric} solutions, and only trivial {\it symmetric} solutions. We then show that the associated energy function is negative for the asymmetric solutions, and zero for the trivial symmetric solution. It follows that a global minimizer of the energy is asymmetric.
△ Less
Submitted 16 March, 1999;
originally announced March 1999.
-
A shooting approach to the Lorenz equations
Authors:
Stuart P. Hastings,
William C. Troy
Abstract:
We announce and outline a proof of the existence of a homoclinic orbit of the Lorenz equations. In addition, we develop a shooting technique and two key conditions, which lead to the existence of a one-to-one correspondence between a set of solutions and the set of all infinite sequences of 1's and 3's.
We announce and outline a proof of the existence of a homoclinic orbit of the Lorenz equations. In addition, we develop a shooting technique and two key conditions, which lead to the existence of a one-to-one correspondence between a set of solutions and the set of all infinite sequences of 1's and 3's.
△ Less
Submitted 30 September, 1992;
originally announced October 1992.