-
Test of the Equivalence Principle for Superconductors
Authors:
M. P. Ross,
S. M. Fleischer,
I. A. Paulson,
P. Lamb,
B. M. Iritani,
E. G. Adelberger,
C. A. Hagedorn,
K. Venkateswara,
C. Gettings,
E. A. Shaw,
S. K. Apple,
J. H. Gundlach
Abstract:
We searched for violations of the weak equivalence principle using a cryogenic torsion balance with a pendulum comprised of superconducting niobium and copper. We constrain the Eötvös parameter with 95%-confidence to $η_{\text{Nb*-Cu}}~\leq~2.0\times10^{-9}$ and $η_{\text{CP-ee}}\leq9.2\times10^{-4}$ for superconducting niobium and Cooper pairs, respectively.
We searched for violations of the weak equivalence principle using a cryogenic torsion balance with a pendulum comprised of superconducting niobium and copper. We constrain the Eötvös parameter with 95%-confidence to $η_{\text{Nb*-Cu}}~\leq~2.0\times10^{-9}$ and $η_{\text{CP-ee}}\leq9.2\times10^{-4}$ for superconducting niobium and Cooper pairs, respectively.
△ Less
Submitted 19 August, 2024; v1 submitted 30 July, 2024;
originally announced July 2024.
-
Short-range tests of the equivalence principle
Authors:
G. L. Smith,
C. D. Hoyle,
J. H. Gundlach,
E. G. Adelberger,
B. R. Heckel,
H. E. Swanson
Abstract:
We tested the equivalence principle at short length scales by rotating a 3-ton $^{238}$U attractor around a compact torsion balance containing Cu and Pb test bodies. The observed differential acceleration of the test bodies toward the attractor, $a_{\text{Cu}}-a_{\text{Pb}} =(1.0\pm2.8)\times 10^{-13}$ cm/s$^2$, should be compared to the corresponding gravitational acceleration of…
▽ More
We tested the equivalence principle at short length scales by rotating a 3-ton $^{238}$U attractor around a compact torsion balance containing Cu and Pb test bodies. The observed differential acceleration of the test bodies toward the attractor, $a_{\text{Cu}}-a_{\text{Pb}} =(1.0\pm2.8)\times 10^{-13}$ cm/s$^2$, should be compared to the corresponding gravitational acceleration of $9.2\times10^{-5}$ cm/s$^2$. Our results set new constraints on equivalence-principle violating interactions with Yukawa ranges down to 1 cm, and improve by substantial factors existing limits for ranges between 10 km and 1000 km. Our data also set strong constraints on certain power law potentials that can arise from two-boson exchange processes.
△ Less
Submitted 14 May, 2024;
originally announced May 2024.
-
A Vacuum-Compatible Cylindrical Inertial Rotation Sensor with Picoradian Sensitivity
Authors:
M. P. Ross,
J. van Dongen,
Y. Huang,
P. Zhou,
Y. Chowdhury,
S. K. Apple,
C. M. Mow-Lowry,
A. L. Mitchell,
N. A. Holland,
B. Lantz,
E. Bonilla,
A. Engl,
A. Pele,
D. Griffith,
E. Sanchez,
E. A. Shaw,
C. Gettings,
J. H. Gundlach
Abstract:
We describe an inertial rotation sensor with a 30-cm cylindrical proof-mass suspended from a pair of 14-$μ$m thick BeCu flexures. The angle between the proof-mass and support structure is measured with a pair of homodyne interferometers which achieve a noise level of $\sim 5\ \text{prad}/\sqrt{\text{Hz}}$. The sensor is entirely made of vacuum compatible materials and the center of mass can be adj…
▽ More
We describe an inertial rotation sensor with a 30-cm cylindrical proof-mass suspended from a pair of 14-$μ$m thick BeCu flexures. The angle between the proof-mass and support structure is measured with a pair of homodyne interferometers which achieve a noise level of $\sim 5\ \text{prad}/\sqrt{\text{Hz}}$. The sensor is entirely made of vacuum compatible materials and the center of mass can be adjusted remotely.
△ Less
Submitted 14 September, 2023; v1 submitted 11 July, 2023;
originally announced July 2023.
-
A Pseudo Plane-wave Gravitational Calibrator for Gravitational Wave Observatories
Authors:
M. P. Ross,
J. H. Gundlach,
E. G. Adelberger,
C. M. Weller,
E. A. Shaw,
C. Gettings,
J. Kissel,
T. Mistry,
L. Datrier,
E. Daw,
M. Hendry
Abstract:
The precisions of existing gravitational calibrators for gravitational wave observatories are limited by their dependence on the relative position between the calibrators and the observatory's test masses. Here we present a novel geometry consisting of four quadrupole rotors placed at the vertices of a rectangle centered on the test mass. The phases and rotation directions are selected to produce…
▽ More
The precisions of existing gravitational calibrators for gravitational wave observatories are limited by their dependence on the relative position between the calibrators and the observatory's test masses. Here we present a novel geometry consisting of four quadrupole rotors placed at the vertices of a rectangle centered on the test mass. The phases and rotation directions are selected to produce a pseudo plane-wave sinusoidal gravitational acceleration with amplitude of ~ 100 fm/s^2. We show that this acceleration only has minimal dependence on the test mass position relative to the rotor array and can yield 0.15% acceleration amplitude uncertainty while tolerating a 1-cm test mass position uncertainty. The acceleration can be directed precisely along the optical axis of the interferometer arm and applies no torque on the test mass. In addition, the small size of the rotors has significant engineering and safety benefits.
△ Less
Submitted 25 January, 2023;
originally announced January 2023.
-
A Cryogenic Torsion Balance Using a Liquid-Cryogen Free, Ultra-Low Vibration Cryostat
Authors:
S. M. Fleischer,
M. P. Ross,
K. Venkateswara,
C. A. Hagedorn,
E. A. Shaw,
E. Swanson,
B. R. Heckel,
J. H. Gundlach
Abstract:
We describe a liquid-cryogen free cryostat with ultra-low vibration levels which allows for continuous operation of a torsion balance at cryogenic temperatures. The apparatus uses a commercially available two-stage pulse-tube cooler and passive vibration isolation. The torsion balance exhibits torque noise levels lower than room temperature thermal noise by a factor of about four in the frequency…
▽ More
We describe a liquid-cryogen free cryostat with ultra-low vibration levels which allows for continuous operation of a torsion balance at cryogenic temperatures. The apparatus uses a commercially available two-stage pulse-tube cooler and passive vibration isolation. The torsion balance exhibits torque noise levels lower than room temperature thermal noise by a factor of about four in the frequency range of 3-10mHz, limited by residual seismic motion and by radiative heating of the pendulum body. In addition to lowering thermal noise below room-temperature limits, the low-temperature environment enables novel torsion balance experiments. Currently, the maximum duration of a continuous measurement run is limited by accumulation of cryogenic surface contamination on the optical elements inside the cryostat.
△ Less
Submitted 8 November, 2022; v1 submitted 6 June, 2022;
originally announced June 2022.
-
New Horizons: Scalar and Vector Ultralight Dark Matter
Authors:
D. Antypas,
A. Banerjee,
C. Bartram,
M. Baryakhtar,
J. Betz,
J. J. Bollinger,
C. Boutan,
D. Bowring,
D. Budker,
D. Carney,
G. Carosi,
S. Chaudhuri,
S. Cheong,
A. Chou,
M. D. Chowdhury,
R. T. Co,
J. R. Crespo López-Urrutia,
M. Demarteau,
N. DePorzio,
A. V. Derbin,
T. Deshpande,
M. D. Chowdhury,
L. Di Luzio,
A. Diaz-Morcillo,
J. M. Doyle
, et al. (104 additional authors not shown)
Abstract:
The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical,…
▽ More
The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical, largely coherent field. This white paper focuses on searches for wavelike scalar and vector dark matter candidates.
△ Less
Submitted 28 March, 2022;
originally announced March 2022.
-
A torsion-balance search for ultra low-mass bosonic dark matter
Authors:
E. A. Shaw,
M. P. Ross,
C. A. Hagedorn,
E. G. Adelberger,
J. H. Gundlach
Abstract:
We used a stationary torsion balance with a beryllium-aluminum composition dipole to search for ultra low-mass bosonic dark matter coupled to baryon minus lepton number. We set 95% confidence limits on the coupling constant $g_{\rm B-L}$ for bosons with masses between $10^{-18}$ and $10^{-16}$ eV/$c^2$ with the best performance at $m_{\rm DM} = 8\times 10^{-18}$ eV/$c^2$ constraining…
▽ More
We used a stationary torsion balance with a beryllium-aluminum composition dipole to search for ultra low-mass bosonic dark matter coupled to baryon minus lepton number. We set 95% confidence limits on the coupling constant $g_{\rm B-L}$ for bosons with masses between $10^{-18}$ and $10^{-16}$ eV/$c^2$ with the best performance at $m_{\rm DM} = 8\times 10^{-18}$ eV/$c^2$ constraining $g_{B-L}(\hbar c)^{-1/2} < 1 \times 10^{-25}$. This provides a complimentary limit to equivalence-principle experiments that search for ultra low-mass bosons as force-mediating particles.
△ Less
Submitted 10 January, 2022; v1 submitted 17 September, 2021;
originally announced September 2021.
-
A Low-Frequency Torsion Pendulum with Interferometric Readout
Authors:
M. P. Ross,
K. Venkateswara,
C. A. Hagedorn,
C. J. Leupold,
P. W. F. Forsyth,
J. D. Wegner,
E. A. Shaw,
J. G. Lee,
J. H. Gundlach
Abstract:
We describe a torsion pendulum with a large mass-quadrupole moment and a resonant frequency of 2.8 mHz, whose angle is measured using a modified Michelson interferometer. The system achieved noise levels of $\sim200\ \text{prad}/\sqrt{\text{Hz}}$ between 0.2-30 Hz and $\sim10\ \text{prad}/\sqrt{\text{Hz}}$ above 100 Hz. Such a system can be applied to a broad range of fields from the study of rota…
▽ More
We describe a torsion pendulum with a large mass-quadrupole moment and a resonant frequency of 2.8 mHz, whose angle is measured using a modified Michelson interferometer. The system achieved noise levels of $\sim200\ \text{prad}/\sqrt{\text{Hz}}$ between 0.2-30 Hz and $\sim10\ \text{prad}/\sqrt{\text{Hz}}$ above 100 Hz. Such a system can be applied to a broad range of fields from the study of rotational seismic motion and elastogravity signals to gravitational wave observation and tests of gravity.
△ Less
Submitted 20 April, 2021; v1 submitted 4 January, 2021;
originally announced January 2021.
-
Limits on the Stochastic Gravitational Wave Background and Prospects for Single Source Detection with GRACE Follow-On
Authors:
M. P. Ross,
C. A. Hagedorn,
E. A. Shaw,
A. L. Lockwood,
B. M. Iritani,
J. G. Lee,
K. Venkateswara,
J. H. Gundlach
Abstract:
With a reinterpretation of recent results, the GRACE Follow-On mission can be applied to gravitational wave astronomy. Existing GRACE Follow-On data constrain the stochastic gravitational wave background to $Ω_{GW}<3.3\times10^{7}$ at 100 mHz. With a dedicated analysis, GRACE Follow-On may be able to detect the inspiral of local neutron star binaries, inspiral of subgalactic stellar-mass black hol…
▽ More
With a reinterpretation of recent results, the GRACE Follow-On mission can be applied to gravitational wave astronomy. Existing GRACE Follow-On data constrain the stochastic gravitational wave background to $Ω_{GW}<3.3\times10^{7}$ at 100 mHz. With a dedicated analysis, GRACE Follow-On may be able to detect the inspiral of local neutron star binaries, inspiral of subgalactic stellar-mass black hole binaries, or mergers of intermediate-mass black hole binaries within the Milky Way.
△ Less
Submitted 13 May, 2020; v1 submitted 5 February, 2020;
originally announced February 2020.
-
Low Frequency Tilt Seismology with a Precision Ground Rotation Sensor
Authors:
M. P. Ross,
K. Venkateswara,
C. A. Hagedorn,
J. H. Gundlach,
J. S. Kissel,
J. Warner,
H. Radkins,
T. J. Shaffer,
M. W. Coughlin,
P. Bodin
Abstract:
We describe measurements of the rotational component of teleseismic surface waves using an inertial high-precision ground-rotation-sensor installed at the LIGO Hanford Observatory (LHO). The sensor has a noise floor of 0.4 nrad$/ \sqrt{\rm Hz}$ at 50 mHz and a translational coupling of less than 1 $μ$rad/m enabling translation-free measurement of small rotations. We present observations of the rot…
▽ More
We describe measurements of the rotational component of teleseismic surface waves using an inertial high-precision ground-rotation-sensor installed at the LIGO Hanford Observatory (LHO). The sensor has a noise floor of 0.4 nrad$/ \sqrt{\rm Hz}$ at 50 mHz and a translational coupling of less than 1 $μ$rad/m enabling translation-free measurement of small rotations. We present observations of the rotational motion from Rayleigh waves of six teleseismic events from varied locations and with magnitudes ranging from M6.7 to M7.9. These events were used to estimate phase dispersion curves which shows agreement with a similar analysis done with an array of three STS-2 seismometers also located at LHO.
△ Less
Submitted 25 July, 2017; v1 submitted 10 July, 2017;
originally announced July 2017.
-
Recent measurements of the gravitational constant as a function of time
Authors:
S. Schlamminger,
J. H. Gundlach,
R. D. Newman
Abstract:
A recent publication (J.D. Anderson et. al., EPL 110, 1002) presented a strong correlation between the measured values of the gravitational constant $G$ and the 5.9-year oscillation of the length of day. Here, we provide a compilation of all published measurements of $G$ taken over the last 35 years. A least squares regression to a sine with a period of 5.9 years still yields a better fit than a s…
▽ More
A recent publication (J.D. Anderson et. al., EPL 110, 1002) presented a strong correlation between the measured values of the gravitational constant $G$ and the 5.9-year oscillation of the length of day. Here, we provide a compilation of all published measurements of $G$ taken over the last 35 years. A least squares regression to a sine with a period of 5.9 years still yields a better fit than a straight line. However, our additions and corrections to the G data reported by Anderson {\it et al.} significantly weaken the correlation.
△ Less
Submitted 21 May, 2015; v1 submitted 7 May, 2015;
originally announced May 2015.
-
Nanopore Sequencing of the phi X 174 genome
Authors:
Andrew H. Laszlo,
Ian M. Derrington,
Brian C. Ross,
Henry Brinkerhoff,
Andrew Adey,
Ian C. Nova,
Jonathan M. Craig,
Kyle W. Langford,
Jenny Mae Samson,
Riza Daza,
Kenji Doering,
Jay Shendure,
Jens H. Gundlach
Abstract:
Nanopore sequencing of DNA is a single-molecule technique that may achieve long reads, low cost, and high speed with minimal sample preparation and instrumentation. Here, we build on recent progress with respect to nanopore resolution and DNA control to interpret the procession of ion current levels observed during the translocation of DNA through the pore MspA. As approximately four nucleotides a…
▽ More
Nanopore sequencing of DNA is a single-molecule technique that may achieve long reads, low cost, and high speed with minimal sample preparation and instrumentation. Here, we build on recent progress with respect to nanopore resolution and DNA control to interpret the procession of ion current levels observed during the translocation of DNA through the pore MspA. As approximately four nucleotides affect the ion current of each level, we measured the ion current corresponding to all 256 four-nucleotide combinations (quadromers). This quadromer map is highly predictive of ion current levels of previously unmeasured sequences derived from the bacteriophage phi X 174 genome. Furthermore, we show nanopore sequencing reads of phi X 174 up to 4,500 bases in length that can be unambiguously aligned to the phi X 174 reference genome, and demonstrate proof-of-concept utility with respect to hybrid genome assembly and polymorphism detection. All methods and data are made fully available.
△ Less
Submitted 18 June, 2014; v1 submitted 16 June, 2014;
originally announced June 2014.
-
A high-precision mechanical absolute-rotation sensor
Authors:
Krishna Venkateswara,
Charles A. Hagedorn,
Matthew D. Turner,
Trevor Arp,
Jens H. Gundlach
Abstract:
We have developed a mechanical absolute-rotation sensor capable of resolving ground rotation angle of less than 1 nrad$/\sqrt{\text{Hz}}$ above $30$ mHz and 0.2 nrad$/\sqrt{\text{Hz}}$ above $100$ mHz about a single horizontal axis. The device consists of a meter-scale beam balance, suspended by a pair of flexures, with a resonance frequency of 10.8 mHz. The center of mass is located 3 $μ$m above…
▽ More
We have developed a mechanical absolute-rotation sensor capable of resolving ground rotation angle of less than 1 nrad$/\sqrt{\text{Hz}}$ above $30$ mHz and 0.2 nrad$/\sqrt{\text{Hz}}$ above $100$ mHz about a single horizontal axis. The device consists of a meter-scale beam balance, suspended by a pair of flexures, with a resonance frequency of 10.8 mHz. The center of mass is located 3 $μ$m above the pivot, giving an excellent horizontal displacement rejection of better than $3\times10^{-5}$ rad/m. The angle of the beam is read out optically using a high-sensitivity autocollimator. We have also built a tiltmeter with better than 1 nrad$/\sqrt{\text{Hz}}$ sensitivity above 30 mHz. Co-located measurements using the two instruments allowed us to distinguish between background rotation signal at low frequencies and intrinsic instrument noise. The rotation sensor is useful for rotational seismology and for rejecting background rotation signal from seismometers in experiments demanding high levels of seismic isolation, such as Advanced LIGO.
△ Less
Submitted 16 January, 2014;
originally announced January 2014.
-
A reference-beam autocollimator with nanoradian sensitivity from mHz to kHz and dynamic range of 10^7
Authors:
T. B. Arp,
C. A. Hagedorn,
S. Schlamminger,
J. H. Gundlach
Abstract:
We describe an autocollimating optical angle sensor with a dynamic range of 9 mrad and nrad/sqrt(Hz) sensitivity at frequencies from 5 mHz to 3 kHz. This work improves the standard multi-slit autocollimator design by adding two optical components, a reference mirror and a condensing lens. This autocollimator makes a differential measurement between a reference mirror and a target mirror, suppressi…
▽ More
We describe an autocollimating optical angle sensor with a dynamic range of 9 mrad and nrad/sqrt(Hz) sensitivity at frequencies from 5 mHz to 3 kHz. This work improves the standard multi-slit autocollimator design by adding two optical components, a reference mirror and a condensing lens. This autocollimator makes a differential measurement between a reference mirror and a target mirror, suppressing common-mode noise sources. The condensing lens reduces optical aberrations, increases intensity, and improves image quality. To further improve the stability of the device at low frequencies the body of the autocollimator is designed to reduce temperature variations and their effects. A new data processing technique was developed in order to suppress the effects of imperfections in the CCD.
△ Less
Submitted 18 September, 2013;
originally announced September 2013.
-
Torsion-balance tests of the weak equivalence principle
Authors:
T. A. Wagner,
S. Schlamminger,
J. H. Gundlach,
E. G. Adelberger
Abstract:
We briefly summarize motivations for testing the weak equivalence principle and then review recent torsion-balance results that compare the differential accelerations of beryllium-aluminum and beryllium-titanium test body pairs with precisions at the part in $10^{13}$ level. We discuss some implications of these results for the gravitational properties of antimatter and dark matter, and speculate…
▽ More
We briefly summarize motivations for testing the weak equivalence principle and then review recent torsion-balance results that compare the differential accelerations of beryllium-aluminum and beryllium-titanium test body pairs with precisions at the part in $10^{13}$ level. We discuss some implications of these results for the gravitational properties of antimatter and dark matter, and speculate about the prospects for further improvements in experimental sensitivity.
△ Less
Submitted 10 July, 2012;
originally announced July 2012.
-
Brownian force noise from molecular collisions and the sensitivity of advanced gravitational wave observatories
Authors:
R. Dolesi,
M. Hueller,
D. Nicolodi,
D. Tombolato,
S. Vitale,
P. J. Wass,
W. J. Weber,
M. Evans,
P. Fritschel,
R. Weiss,
J. H. Gundlach,
C. A. Hagedorn,
S. Schlamminger,
G. Ciani,
A. Cavalleri
Abstract:
We present an analysis of Brownian force noise from residual gas damping of reference test masses as a fundamental sensitivity limit in small force experiments. The resulting acceleration noise increases significantly when the distance of the test mass to the surrounding experimental apparatus is smaller than the dimension of the test mass itself. For the Advanced LIGO interferometric gravitationa…
▽ More
We present an analysis of Brownian force noise from residual gas damping of reference test masses as a fundamental sensitivity limit in small force experiments. The resulting acceleration noise increases significantly when the distance of the test mass to the surrounding experimental apparatus is smaller than the dimension of the test mass itself. For the Advanced LIGO interferometric gravitational wave observatory, where the relevant test mass is a suspended 340 mm diameter cylindrical end mirror, the force noise power is increased by roughly a factor 40 by the presence of a similarly shaped reaction mass at a nominal separation of 5 mm. The force noise, of order 20 fN\rthz\ for $2 \times 10^{-6}$ Pa of residual H$_2$ gas, rivals quantum optical fluctuations as the dominant noise source between 10 and 30 Hz. We present here a numerical and analytical analysis for the gas damping force noise for Advanced LIGO, backed up by experimental evidence from several recent measurements. Finally, we discuss the impact of residual gas damping on the gravitational wave sensitivity and possible mitigation strategies.
△ Less
Submitted 30 September, 2011; v1 submitted 16 August, 2011;
originally announced August 2011.
-
Picoradian deflection measurement with an interferometric quasi-autocollimator using weak value amplification
Authors:
Matthew D. Turner,
Charles A. Hagedorn,
Stephan Schlamminger,
Jens H. Gundlach
Abstract:
We present an "interferometric quasi-autocollimator" that employs weak value amplification to measure angular deflections of a target mirror. The device has been designed to be insensitive to all translations of the target. We present a conceptual explanation of the amplification effect used by the device. An implementation of the device demonstrates sensitivities better than 10 picoradians per ro…
▽ More
We present an "interferometric quasi-autocollimator" that employs weak value amplification to measure angular deflections of a target mirror. The device has been designed to be insensitive to all translations of the target. We present a conceptual explanation of the amplification effect used by the device. An implementation of the device demonstrates sensitivities better than 10 picoradians per root hertz between 10 and 200 hertz.
△ Less
Submitted 22 March, 2011;
originally announced March 2011.
-
Indirect Evidence for Lévy Walks in Squeeze Film Damping
Authors:
Stephan Schlamminger,
Charles A. Hagedorn,
Jens H. Gundlach
Abstract:
Molecular flow gas damping of mechanical motion in confined geometries, and its associated noise, is important in a variety of fields, including precision measurement, gravitational wave detection, and MEMS devices. We used two torsion balance instruments to measure the strength and distance-dependence of `squeeze film' damping. Measured quality factors derived from free decay of oscillation are c…
▽ More
Molecular flow gas damping of mechanical motion in confined geometries, and its associated noise, is important in a variety of fields, including precision measurement, gravitational wave detection, and MEMS devices. We used two torsion balance instruments to measure the strength and distance-dependence of `squeeze film' damping. Measured quality factors derived from free decay of oscillation are consistent with gas particle superdiffusion in Lévy walks and inconsistent with those expected from traditional Gaussian random walk particle motion. The distance-dependence of squeeze film damping observed in our experiments is in agreement with a parameter-free Monte Carlo simulation. The squeeze film damping of the motion of a plate suspended a distance d away from a parallel surface scales with a fractional power between 1/d and 1/d^2.
△ Less
Submitted 29 May, 2010; v1 submitted 26 May, 2010;
originally announced May 2010.
-
Charge Management for Gravitational Wave Observatories using UV LEDs
Authors:
S. E. Pollack,
M. D. Turner,
S. Schlamminger,
C. A. Hagedorn,
J. H. Gundlach
Abstract:
Accumulation of electrical charge on the end mirrors of gravitational wave observatories, such as the space-based LISA mission and ground-based LIGO detectors, can become a source of noise limiting the sensitivity of such detectors through electronic couplings to nearby surfaces. Torsion balances provide an ideal means for testing gravitational wave technologies due to their high sensitivity to…
▽ More
Accumulation of electrical charge on the end mirrors of gravitational wave observatories, such as the space-based LISA mission and ground-based LIGO detectors, can become a source of noise limiting the sensitivity of such detectors through electronic couplings to nearby surfaces. Torsion balances provide an ideal means for testing gravitational wave technologies due to their high sensitivity to small forces. Our torsion pendulum apparatus consists of a movable Au-coated Cu plate brought near a Au-coated Si plate pendulum suspended from a non-conducting quartz fiber. A UV LED located near the pendulum photoejects electrons from the surface, and a UV LED driven electron gun directs photoelectrons towards the pendulum surface. We have demonstrated both charging and discharging of the pendulum with equivalent charging rates of $\sim$$10^5 e/\mathrm{s}$, as well as spectral measurements of the pendulum charge resulting in a white noise level equivalent to $3\times10^5 e/\sqrt{Hz}$.
△ Less
Submitted 9 December, 2009;
originally announced December 2009.
-
Test of the Equivalence Principle Using a Rotating Torsion Balance
Authors:
S. Schlamminger,
K. -Y. Choi,
T. A. Wagner,
J. H. Gundlach,
E. G. Adelberger
Abstract:
We used a continuously rotating torsion balance instrument to measure the acceleration difference of beryllium and titanium test bodies towards sources at a variety of distances. Our result Delta a=(0.6+/-3.1)x10^-15 m/s^2 improves limits on equivalence-principle violations with ranges from 1 m to infinity by an order of magnitude. The Eoetvoes parameter is eta=(0.3+/-1.8)x10^-13. By analyzing o…
▽ More
We used a continuously rotating torsion balance instrument to measure the acceleration difference of beryllium and titanium test bodies towards sources at a variety of distances. Our result Delta a=(0.6+/-3.1)x10^-15 m/s^2 improves limits on equivalence-principle violations with ranges from 1 m to infinity by an order of magnitude. The Eoetvoes parameter is eta=(0.3+/-1.8)x10^-13. By analyzing our data for accelerations towards the center of the Milky Way we find equal attractions of Be and Ti towards galactic dark matter, yielding eta=(-4 +/- 7)x10^-5. Space-fixed differential accelerations in any direction are limited to less than 8.8x10^-15 m/s^2 with 95% confidence.
△ Less
Submitted 4 December, 2007;
originally announced December 2007.
-
High Sensitivity Torsion Balance Tests for LISA Proof Mass Modeling
Authors:
S. Schlamminger,
C. A. Hagedorn,
M. G. Famulare,
S. E. Pollack,
J. H. Gundlach
Abstract:
We have built a highly sensitive torsion balance to investigate small forces between closely spaced gold coated surfaces. Such forces will occur between the LISA proof mass and its housing. These forces are not well understood and experimental investigations are imperative. We describe our torsion balance and present the noise of the system. A significant contribution to the LISA noise budget at…
▽ More
We have built a highly sensitive torsion balance to investigate small forces between closely spaced gold coated surfaces. Such forces will occur between the LISA proof mass and its housing. These forces are not well understood and experimental investigations are imperative. We describe our torsion balance and present the noise of the system. A significant contribution to the LISA noise budget at low frequencies is the fluctuation in the surface potential difference between the proof mass and its housing. We present first results of these measurements with our apparatus.
△ Less
Submitted 8 February, 2007;
originally announced February 2007.
-
Outgassing, Temperature Gradients and the Radiometer Effect in LISA: A Torsion Pendulum Investigation
Authors:
Scott E Pollack,
Stephan Schlamminger,
Jens H Gundlach
Abstract:
Thermal modeling of the LISA gravitational reference sensor (GRS) includes such effects as outgassing from the proof mass and its housing and the radiometer effect. Experimental data in conditions emulating the LISA GRS are required to confidently predict the GRS performance. Outgassing and the radiometer effect are similar in characteristics and are difficult to decouple experimentally.
The d…
▽ More
Thermal modeling of the LISA gravitational reference sensor (GRS) includes such effects as outgassing from the proof mass and its housing and the radiometer effect. Experimental data in conditions emulating the LISA GRS are required to confidently predict the GRS performance. Outgassing and the radiometer effect are similar in characteristics and are difficult to decouple experimentally.
The design of our torsion balance allows us to investigate differential radiation pressure, the radiometer effect, and outgassing on closely separated conducting surfaces with high sensitivity. A thermally controlled split copper plate is brought near a freely hanging plate-torsion pendulum.We have varied the temperature on each half of the copper plate and have measured the resulting forces on the pendulum.
We have determined that to first order the current GRS model for the radiometer effect, outgassing, and radiation pressure are mostly consistent with our torsion balance measurements and therefore these thermal effects do not appear to be a large hindrance to the LISA noise budget. However, there remain discrepancies between the predicted dependence of these effects on the temperature of our apparatus.
△ Less
Submitted 8 February, 2007; v1 submitted 8 February, 2007;
originally announced February 2007.
-
Tests of the Gravitational Inverse-Square Law below the Dark-Energy Length Scale
Authors:
D. J. Kapner,
T. S. Cook,
E. G. Adelberger,
J. H. Gundlach,
B. R. Heckel,
C. D. Hoyle,
H. E. Swanson
Abstract:
We conducted three torsion-balance experiments to test the gravitational inverse-square law at separations between 9.53 mm and 55 micrometers, probing distances less than the dark-energy length scale $λ_{\rm d}=\sqrt[4]{\hbar c/ρ_{\rm d}}\approx 85 μ$m. We find with 95% confidence that the inverse-square law holds ($|α| \leq 1$) down to a length scale $λ= 56 μ$m and that an extra dimension must…
▽ More
We conducted three torsion-balance experiments to test the gravitational inverse-square law at separations between 9.53 mm and 55 micrometers, probing distances less than the dark-energy length scale $λ_{\rm d}=\sqrt[4]{\hbar c/ρ_{\rm d}}\approx 85 μ$m. We find with 95% confidence that the inverse-square law holds ($|α| \leq 1$) down to a length scale $λ= 56 μ$m and that an extra dimension must have a size $R \leq 44 μ$m.
△ Less
Submitted 14 November, 2006;
originally announced November 2006.
-
Sub-millimeter Tests of the Gravitational Inverse-square Law
Authors:
C. D. Hoyle,
D. J. Kapner,
B. R. Heckel,
E. G. Adelberger,
J. H. Gundlach,
U. Schmidt,
H. E. Swanson
Abstract:
Motivated by a variety of theories that predict new effects, we tested the gravitational 1/r^2 law at separations between 10.77 mm and 137 microns using two different 10-fold azimuthally symmetric torsion pendulums and rotating 10-fold symmetric attractors. Our work improves upon other experiments by up to a factor of about 100. We found no deviation from Newtonian physics at the 95% confidence…
▽ More
Motivated by a variety of theories that predict new effects, we tested the gravitational 1/r^2 law at separations between 10.77 mm and 137 microns using two different 10-fold azimuthally symmetric torsion pendulums and rotating 10-fold symmetric attractors. Our work improves upon other experiments by up to a factor of about 100. We found no deviation from Newtonian physics at the 95% confidence level and interpret these results as constraints on extensions of the Standard Model that predict Yukawa or power-law forces. We set a constraint on the largest single extra dimension (assuming toroidal compactification and that one extra dimension is significantly larger than all the others) of R <= 160 microns, and on two equal-sized large extra dimensions of R <= 130 microns. Yukawa interactions with |alpha| >= 1 are ruled out at 95% confidence for lambda >= 197 microns. Extra-dimensions scenarios stabilized by radions are restricted to unification masses M >= 3.0 TeV/c^2, regardless of the number of large extra dimensions. We also provide new constraints on power-law potentials V(r)\propto r^{-k} with k between 2 and 5 and on the gamma_5 couplings of pseudoscalars with m <= 10 meV/c^2.
△ Less
Submitted 26 August, 2004; v1 submitted 26 May, 2004;
originally announced May 2004.
-
Sub-millimeter tests of the gravitational inverse-square law: A search for "large" extra dimensions
Authors:
C. D. Hoyle,
U. Schmidt,
B. R. Heckel,
E. G. Adelberger,
J. H. Gundlach,
D. J. Kapner,
H. E. Swanson
Abstract:
Motivated by higher-dimensional theories that predict new effects, we tested the gravitational 1/r^2 law at separations ranging down to 218 micrometers using a 10-fold symmetric torsion pendulum and a rotating 10-fold symmetric attractor. We improved previous short-range constraints by up to a factor of 1000 and find no deviations from Newtonian physics.
Motivated by higher-dimensional theories that predict new effects, we tested the gravitational 1/r^2 law at separations ranging down to 218 micrometers using a 10-fold symmetric torsion pendulum and a rotating 10-fold symmetric attractor. We improved previous short-range constraints by up to a factor of 1000 and find no deviations from Newtonian physics.
△ Less
Submitted 1 November, 2000;
originally announced November 2000.
-
Measurement of Newton's Constant Using a Torsion Balance with Angular Acceleration Feedback
Authors:
Jens H. Gundlach,
Stephen M. Merkowitz
Abstract:
We measured Newton's gravitational constant G using a new torsion balance method. Our technique greatly reduces several sources of uncertainty compared to previous measurements: (1) it is insensitive to anelastic torsion fiber properties; (2) a flat plate pendulum minimizes the sensitivity due to the pendulum density distribution; (3) continuous attractor rotation reduces background noise. We ob…
▽ More
We measured Newton's gravitational constant G using a new torsion balance method. Our technique greatly reduces several sources of uncertainty compared to previous measurements: (1) it is insensitive to anelastic torsion fiber properties; (2) a flat plate pendulum minimizes the sensitivity due to the pendulum density distribution; (3) continuous attractor rotation reduces background noise. We obtain G = (6.674215 +- 0.000092)x10^-11 m^3kg^-1s^-2; the Earth's mass is, therefore, M = (5.972245 +- 0.000082)x10^24 kg and the Sun's mass is M = (1.988435 +- 0.000027)x10^30kg.
△ Less
Submitted 7 August, 2000; v1 submitted 12 June, 2000;
originally announced June 2000.