-
Development of crystal optics for Multi-Projection X-ray Imaging for synchrotron and XFEL sources
Authors:
Valerio Bellucci,
Sarlota Birnsteinova,
Tokushi Sato,
Romain Letrun,
Jayanath C. P. Koliyadu,
Chan Kim,
Gabriele Giovanetti,
Carsten Deiter,
Liubov Samoylova,
Ilia Petrov,
Luis Lopez Morillo,
Rita Graceffa,
Luigi Adriano,
Helge Huelsen,
Heiko Kollmann,
Thu Nhi Tran Calliste,
Dusan Korytar,
Zdenko Zaprazny,
Andrea Mazzolari,
Marco Romagnoni,
Eleni Myrto Asimakopoulou,
Zisheng Yao,
Yuhe Zhang,
Jozef Ulicny,
Alke Meents
, et al. (5 additional authors not shown)
Abstract:
X-ray Multi-Projection Imaging (XMPI) is an emerging technology that allows for the acquisition of millions of 3D images per second in samples opaque to visible light. This breakthrough capability enables volumetric observation of fast stochastic phenomena, which were inaccessible due to the lack of a volumetric X-ray imaging probe with kHz to MHz repetition rate. These include phenomena of indust…
▽ More
X-ray Multi-Projection Imaging (XMPI) is an emerging technology that allows for the acquisition of millions of 3D images per second in samples opaque to visible light. This breakthrough capability enables volumetric observation of fast stochastic phenomena, which were inaccessible due to the lack of a volumetric X-ray imaging probe with kHz to MHz repetition rate. These include phenomena of industrial and societal relevance such as fractures in solids, propagation of shock waves, laser-based 3D printing, or even fast processes in the biological domain. Indeed, the speed of traditional tomography is limited by the shear forces caused by rotation, to a maximum of 1000 Hz in state-of-the-art tomography. Moreover, the shear forces can disturb the phenomena in observation, in particular with soft samples or sensitive phenomena such as fluid dynamics. XMPI is based on splitting an X-ray beam to generate multiple simultaneous views of the sample, therefore eliminating the need for rotation. The achievable performances depend on the characteristics of the X-ray source, the detection system, and the X-ray optics used to generate the multiple views. The increase in power density of the X-ray sources around the world now enables 3D imaging with sampling speeds in the kilohertz range at synchrotrons and megahertz range at X-ray Free-Electron Lasers (XFELs). Fast detection systems are already available, and 2D MHz imaging was already demonstrated at synchrotron and XFEL. In this work, we explore the properties of X-ray splitter optics and XMPI schemes that are compatible with synchrotron insertion devices and XFEL X-ray beams. We describe two possible schemes designed to permit large samples and complex sample environments. Then, we present experimental proof of the feasibility of MHz-rate XMPI at the European XFEL.
△ Less
Submitted 8 February, 2024;
originally announced February 2024.
-
Megahertz X-ray Multi-projection imaging
Authors:
Pablo Villanueva-Perez,
Valerio Bellucci,
Yuhe Zhang,
Sarlota Birnsteinova,
Rita Graceffa,
Luigi Adriano,
Eleni Myrto Asimakopoulou,
Ilia Petrov,
Zisheng Yao,
Marco Romagnoni,
Andrea Mazzolari,
Romain Letrun,
Chan Kim,
Jayanath C. P. Koliyadu,
Carsten Deiter,
Richard Bean,
Gabriele Giovanetti,
Luca Gelisio,
Tobias Ritschel,
Adrian Mancuso,
Henry N. Chapman,
Alke Meents,
Tokushi Sato,
Patrik Vagovic
Abstract:
X-ray time-resolved tomography is one of the most popular X-ray techniques to probe dynamics in three dimensions (3D). Recent developments in time-resolved tomography opened the possibility of recording kilohertz-rate 3D movies. However, tomography requires rotating the sample with respect to the X-ray beam, which prevents characterization of faster structural dynamics. Here, we present megahertz…
▽ More
X-ray time-resolved tomography is one of the most popular X-ray techniques to probe dynamics in three dimensions (3D). Recent developments in time-resolved tomography opened the possibility of recording kilohertz-rate 3D movies. However, tomography requires rotating the sample with respect to the X-ray beam, which prevents characterization of faster structural dynamics. Here, we present megahertz (MHz) X-ray multi-projection imaging (MHz-XMPI), a technique capable of recording volumetric information at MHz rates and micrometer resolution without scanning the sample. We achieved this by harnessing the unique megahertz pulse structure and intensity of the European X-ray Free-electron Laser with a combination of novel detection and reconstruction approaches that do not require sample rotations. Our approach enables generating multiple X-ray probes that simultaneously record several angular projections for each pulse in the megahertz pulse burst. We provide a proof-of-concept demonstration of the MHz-XMPI technique's capability to probe 4D (3D+time) information on stochastic phenomena and non-reproducible processes three orders of magnitude faster than state-of-the-art time-resolved X-ray tomography, by generating 3D movies of binary droplet collisions. We anticipate that MHz-XMPI will enable in-situ and operando studies that were impossible before, either due to the lack of temporal resolution or because the systems were opaque (such as for MHz imaging based on optical microscopy).
△ Less
Submitted 19 May, 2023;
originally announced May 2023.
-
Megahertz X-ray microscopy at X-ray Free-Electron Laser and Synchrotron sources
Authors:
Patrik Vagovič,
Tokushi Sato,
Ladislav Mikeš,
Grant Mills,
Rita Graceffa,
Frans Mattsson,
Pablo Villanueva-Perez,
Alexey Ershov,
Tomáš Faragó,
Jozef Uličný,
Henry Kirkwood,
Romain Letrun,
Rajmund Mokso,
Marie-Christine Zdora,
Margie P. Olbinado,
Alexander Rack,
Tilo Baumbach,
Alke Meents,
Henry N. Chapman,
Adrian P. Mancuso
Abstract:
We demonstrate X-ray phase contrast microscopy performed at the European X-ray Free-Electron Laser sampled at 1.128 MHz rate. We have applied this method to image stochastic processes induced by an optical laser incident on water-filled capillaries with micrometer scale spatial resolution. The generated high speed water jet, cavitation formation and annihilation in water and glass, as well as glas…
▽ More
We demonstrate X-ray phase contrast microscopy performed at the European X-ray Free-Electron Laser sampled at 1.128 MHz rate. We have applied this method to image stochastic processes induced by an optical laser incident on water-filled capillaries with micrometer scale spatial resolution. The generated high speed water jet, cavitation formation and annihilation in water and glass, as well as glass explosions are observed. The comparison between XFEL and previous synchrotron MHz microscopy shows the superior contrast and spatial resolution at the XFEL over the synchrotron. This work opens up new possibilities for the characterization of dynamic stochastic systems on nanosecond to microsecond time scales at megahertz rate with object velocities up to few kilometers per second using X-ray Free-Electron Laser sources.
△ Less
Submitted 13 June, 2019;
originally announced June 2019.