Skip to main content

Showing 1–4 of 4 results for author: Glover, P

.
  1. arXiv:2107.03170  [pdf, other

    physics.app-ph

    Magnetic Field Design in a Cylindrical High-Permeability Shield: The Combination of Simple Building Blocks and a Genetic Algorithm

    Authors: M. Packer, P. J. Hobson, A. Davis, N. Holmes, J. Leggett, P. Glover, N. L. Hardwicke, M. J. Brookes, R. Bowtell, T. M. Fromhold

    Abstract: Magnetically-sensitive experiments and newly-developed quantum technologies with integrated high-permeability magnetic shields require increasing control of their magnetic field environment and reductions in size, weight, power and cost. However, magnetic fields generated by active components are distorted by high-permeability magnetic shielding, particularly when they are close to the shield's su… ▽ More

    Submitted 4 March, 2022; v1 submitted 7 July, 2021; originally announced July 2021.

    Comments: The authors M. Packer and P. J. Hobson have contributed equally to this work. 24 pages, 16 figures

    Journal ref: J. Appl. Phys. 131, 093902 (2022)

  2. Planar Coil Optimization in a Magnetically Shielded Cylinder

    Authors: M. Packer, P. J. Hobson, N. Holmes, J. Leggett, P. Glover, M. J. Brookes, R. Bowtell, T. M. Fromhold

    Abstract: Hybrid magnetic shields with both active field generating components and high-permeability magnetic shielding are increasingly needed for a variety of technologies and experiments that require precision-controlled magnetic field environments. However, the fields generated by the active components interact with the passive magnetic shield, distorting the desired field profiles. Consequently, optimi… ▽ More

    Submitted 3 June, 2021; v1 submitted 4 January, 2021; originally announced January 2021.

    Comments: 24 pages, 10 figures

    Journal ref: Phys. Rev. Applied 15, 064006 (2021)

  3. arXiv:2006.02981  [pdf, other

    physics.app-ph physics.class-ph

    Optimal Inverse Design of Magnetic Field Profiles in a Magnetically Shielded Cylinder

    Authors: M. Packer, P. J. Hobson, N. Holmes, J. Leggett, P. Glover, M. J. Brookes, R. Bowtell, T. M. Fromhold

    Abstract: Magnetic shields that use both active and passive components to enable the generation of a tailored low-field environment are required for many applications in science, engineering, and medical imaging. Until now, accurate field nulling, or field generation, has only been possible over a small fraction of the overall volume of the shield. This is due to the interaction between the active field-gen… ▽ More

    Submitted 7 September, 2020; v1 submitted 4 June, 2020; originally announced June 2020.

    Comments: 22 pages, 9 figures, 1 table

    Journal ref: Phys. Rev. Applied 14, 054004 (2020)

  4. arXiv:1004.5051  [pdf

    cs.CE cs.NE physics.med-ph

    Tailored RF pulse optimization for magnetization inversion at ultra high field

    Authors: Aaron C Hurley, Ali Al-Radaideh, Bai Li, Uwe Aickelin, Ron Coxon, Paul Glover, Penny A. Gowland

    Abstract: The radiofrequency (RF) transmit field is severely inhomogeneous at ultrahigh field due to both RF penetration and RF coil design issues. This particularly impairs image quality for sequences that use inversion pulses such as magnetization prepared rapid acquisition gradient echo and limits the use of quantitative arterial spin labeling sequences such as flow-attenuated inversion recovery. H… ▽ More

    Submitted 28 April, 2010; originally announced April 2010.

    Comments: 8 pages, 9 figures, Magnetic Resonance Imaging for Medicine

    Journal ref: Magnetic Resonance Imaging for Medicine, 63(1), p51-58, 2009