-
Modern approaches to improving phase contrast electron microscopy
Authors:
Jeremy J. Axelrod,
Jessie T. Zhang,
Petar N. Petrov,
Robert M. Glaeser,
Holger Mueller
Abstract:
Although defocus can be used to generate partial phase contrast in transmission electron microscope images, cryo-electron microscopy (cryo-EM) can be further improved by the development of phase plates which increase contrast by applying a phase shift to the unscattered part of the electron beam. Many approaches have been investigated, including the ponderomotive interaction between light and elec…
▽ More
Although defocus can be used to generate partial phase contrast in transmission electron microscope images, cryo-electron microscopy (cryo-EM) can be further improved by the development of phase plates which increase contrast by applying a phase shift to the unscattered part of the electron beam. Many approaches have been investigated, including the ponderomotive interaction between light and electrons. We review the recent successes achieved with this method in high-resolution, single-particle cryo-EM. We also review the status of using pulsed or near-field enhanced laser light as alternatives, along with approaches that use scanning transmission electron microscopy (STEM) with a segmented detector rather than a phase plate.
△ Less
Submitted 12 March, 2024; v1 submitted 21 January, 2024;
originally announced January 2024.
-
High-Power Near-Concentric Fabry-Perot Cavity for Phase Contrast Electron Microscopy
Authors:
Carter Turnbaugh,
Jeremy J. Axelrod,
Sara L. Campbell,
Jeske Y. Dioquino,
Petar N. Petrov,
Jonathan Remis,
Osip Schwartz,
Zanlin Yu,
Yifan Cheng,
Robert M. Glaeser,
Holger Mueller
Abstract:
Transmission electron microscopy (TEM) of vitrified biological macromolecules (cryo-EM) is limited by the weak phase contrast signal that is available from such samples. Using a phase plate would thus substantially improve the signal-to-noise ratio. We have previously demonstrated the use of a high-power Fabry-Perot cavity as a phase plate for TEM. We now report improvements to our laser cavity th…
▽ More
Transmission electron microscopy (TEM) of vitrified biological macromolecules (cryo-EM) is limited by the weak phase contrast signal that is available from such samples. Using a phase plate would thus substantially improve the signal-to-noise ratio. We have previously demonstrated the use of a high-power Fabry-Perot cavity as a phase plate for TEM. We now report improvements to our laser cavity that allow us to achieve record continuous-wave intensities of over 450 GW/cm$^{2}$, sufficient to produce the optimal 90° phase shift for 300 keV electrons. In addition, we have performed the first cryo-EM reconstruction using a laser phase plate, demonstrating that the stability of this laser phase plate is sufficient for use during standard cryo-EM data collection.
△ Less
Submitted 14 December, 2020;
originally announced December 2020.
-
Observation of the relativistic reversal of the ponderomotive potential
Authors:
Jeremy J. Axelrod,
Sara L. Campbell,
Osip Schwartz,
Carter Turnbaugh,
Robert M. Glaeser,
Holger Mueller
Abstract:
The secular dynamics of a non-relativistic charged particle in an electromagnetic wave can be described by the ponderomotive potential. Although ponderomotive electron-laser interactions at relativistic velocities are important for emerging technologies from laser-based particle accelerators to laser-enhanced electron microscopy, the effects of special relativity on the interaction have only been…
▽ More
The secular dynamics of a non-relativistic charged particle in an electromagnetic wave can be described by the ponderomotive potential. Although ponderomotive electron-laser interactions at relativistic velocities are important for emerging technologies from laser-based particle accelerators to laser-enhanced electron microscopy, the effects of special relativity on the interaction have only been studied theoretically. Here, we use a transmission electron microscope to measure the position-dependent phase shift imparted to a relativistic electron wave function when it traverses a standing laser wave. The kinetic energy of the electrons is varied between $80\,\mathrm{keV}$ and $300\,\mathrm{keV}$, and the laser standing wave has a continuous-wave intensity of $175\,\mathrm{GW/cm}^2$. In contrast to the non-relativistic case, we demonstrate that the phase shift depends on both the electron velocity and the wave polarization, confirming the predictions of a quasiclassical theory of the interaction. Remarkably, if the electron's speed is greater than $1/\sqrt{2}$ of the speed of light, the phase shift at the electric field nodes of the wave can exceed that at the antinodes. In this case there exists a polarization such that the phase shifts at the nodes and antinodes are equal, and the electron does not experience Kapitza-Dirac diffraction. Our results thus provide new capabilities for coherent electron beam manipulation.
△ Less
Submitted 1 May, 2020; v1 submitted 29 October, 2019;
originally announced October 2019.
-
Laser control of the electron wave function in transmission electron microscopy
Authors:
O. Schwartz,
J. J. Axelrod,
S. L. Campbell,
C. Turnbaugh,
R. M. Glaeser,
H. Müller
Abstract:
Laser-based preparation, manipulation, and readout of the states of quantum particles has become a powerful research tool that has enabled the most precise measurements of time, fundamental constants, and electromagnetic fields. Laser control of free electrons can improve the detection of electrons' interaction with material objects, thereby advancing the exploration of matter on the atomic scale.…
▽ More
Laser-based preparation, manipulation, and readout of the states of quantum particles has become a powerful research tool that has enabled the most precise measurements of time, fundamental constants, and electromagnetic fields. Laser control of free electrons can improve the detection of electrons' interaction with material objects, thereby advancing the exploration of matter on the atomic scale. For example, temporal modulation of electron waves with light has enabled the study of transient processes with attosecond resolution. In contrast, laser-based spatial shaping of the electron wave function has not yet been realized, even though it could be harnessed to probe radiation-sensitive systems, such as biological macromolecules, at the standard quantum limit and beyond. Here, we demonstrate laser control of the spatial phase profile of the electron wave function and apply it to enhance the image contrast in transmission electron microscopy. We first realize an electron interferometer, using continuous-wave laser-induced retardation to coherently split the electron beam, and capture TEM images of the light wave. We then demonstrate Zernike phase contrast by using the laser beam to shift the phase of the electron wave scattered by a specimen relative to the unscattered wave. Laser-based Zernike phase contrast will advance TEM studies of protein structure, cell organization, and complex materials. The versatile coherent control of free electrons demonstrated here paves the way towards quantum-limited detection and new imaging modalities.
△ Less
Submitted 11 December, 2018;
originally announced December 2018.
-
Continuous 40 GW/cm$^2$ laser intensity in a near-concentric optical cavity
Authors:
Osip Schwartz,
Jeremy J. Axelrod,
Philipp Haslinger,
Colin Ophus,
Robert M. Glaeser,
Holger Müller
Abstract:
Manipulating free-space electron wave functions with laser fields can bring about new electron-optical elements for transmission electron microscopy. In particular, a Zernike phase plate would enable high-contrast imaging of soft matter, leading to new opportunities in structural biology and materials science. A Zernike plate can be implemented using a tight, intense CW laser focus that shifts the…
▽ More
Manipulating free-space electron wave functions with laser fields can bring about new electron-optical elements for transmission electron microscopy. In particular, a Zernike phase plate would enable high-contrast imaging of soft matter, leading to new opportunities in structural biology and materials science. A Zernike plate can be implemented using a tight, intense CW laser focus that shifts the phase of the electron wave by the ponderomotive potential. Here, we use a near-concentric cavity to focus 7.5 kW of circulating laser power at 1064 nm into a 7 $μ$m waist, setting a record for CW laser intensity and establishing a pathway to ponderomotive phase contrast TEM.
△ Less
Submitted 12 December, 2016; v1 submitted 26 October, 2016;
originally announced October 2016.
-
Design of an electron microscope phase plate using a focused continuous-wave laser
Authors:
Holger Mueller,
Jian Jin,
Radostin Danev,
John Spence,
Howard Padmore,
Robert M. Glaeser
Abstract:
We propose a Zernike phase contrast electron microscope that uses an intense laser focus to convert a phase image into a visible image. We present the relativistic quantum theory of the phase shift caused by the laser-electron-interaction, study resonant cavities for enhancing the laser intensity, and discuss applications in biology, soft materials science, and atomic and molecular physics.
We propose a Zernike phase contrast electron microscope that uses an intense laser focus to convert a phase image into a visible image. We present the relativistic quantum theory of the phase shift caused by the laser-electron-interaction, study resonant cavities for enhancing the laser intensity, and discuss applications in biology, soft materials science, and atomic and molecular physics.
△ Less
Submitted 23 February, 2010;
originally announced February 2010.