-
Microcell CPT atomic clock using laser current-actuated power modulation with 10$^{-12}$ range stability at 1 day
Authors:
Carlos Manuel Rivera-Aguilar,
Andrei Mursa,
Clément Carlé,
Jean-Michel Friedt,
Emmanuel Klinger,
Moustafa Abdel Hafiz,
Nicolas Passilly,
Rodolphe Boudot
Abstract:
We present a coherent-population trapping (CPT) microcell atomic clock using symmetric auto-balanced Ramsey (SABR) spectroscopy. The pulsed SABR sequence is applied through direct current-based power modulation of the vertical-cavity surface-emitting laser, eliminating the need for an external optical shutter and enabling compatibility with fully-integrated clocks. The sequence is controlled by a…
▽ More
We present a coherent-population trapping (CPT) microcell atomic clock using symmetric auto-balanced Ramsey (SABR) spectroscopy. The pulsed SABR sequence is applied through direct current-based power modulation of the vertical-cavity surface-emitting laser, eliminating the need for an external optical shutter and enabling compatibility with fully-integrated clocks. The sequence is controlled by a single FPGA-based digital electronics board. A key aspect of proper clock operation was the implementation of a real-time tracking of the atomic signal detection window. The clock frequency dependence on laser power, microwave power, laser frequency, and timing of the detection window has been measured, obtaining sensitivity coefficients lower than those obtained with Ramsey-CPT spectroscopy. The Allan deviation of the SABR-CPT clock, based on a microfabricated cell with low-permeation glass windows, is 1.1~$\times$~10$^{-9}$ at 1~s and averages down to the low 10$^{-12}$ range at 1 day integration time. These results pave the way towards the development of Ramsey-CPT chip-scale atomic clocks with enhanced timekeeping performances.
△ Less
Submitted 3 March, 2025;
originally announced March 2025.
-
Fully digital platform for local ultra-stable optical frequency distribution
Authors:
Martina Matusko,
Ivan Ryger,
Gwenhaël Goavec-Merou,
Jacques Millo,
Clément Lacroûte,
Émile Carry,
Jean-Michel Friedt,
Marion Delehaye
Abstract:
This article reports on the use of a Field Programmable Gate Array (FPGA) platform for local ultra-stable optical frequency distribution through a 90 m-long fiber network. This platform is used to implement a fully digital treatment of the Doppler-cancellation scheme required by fiber links to be able to distribute ultra-stable frequencies. We present a novel protocol that uses aliased images of a…
▽ More
This article reports on the use of a Field Programmable Gate Array (FPGA) platform for local ultra-stable optical frequency distribution through a 90 m-long fiber network. This platform is used to implement a fully digital treatment of the Doppler-cancellation scheme required by fiber links to be able to distribute ultra-stable frequencies. We present a novel protocol that uses aliased images of a digital synthesizer output to directly generate signals above the Nyquist frequency. This approach significantly simplifies the setup, making it easy to duplicate within a local fiber network. We demonstrate performances enabling the distribution of an optical signal with an instability below $10^{-17}$ at 1 s at the receiver end. We also use the board to implement an original characterization method. It leads to an efficient characterization of the disturbance rejection of the system that can be realized without accessing the remote output of the fiber link.
△ Less
Submitted 30 October, 2023;
originally announced November 2023.
-
Digital Doppler-cancellation servo for ultra-stable optical frequency dissemination over fiber
Authors:
Shambo Mukherjee,
Jacques Millo,
Baptiste Marechal,
Séverine Denis,
Gwenhaël Goavec-Mérou,
Jean-Michel Friedt,
Yann Kersalé,
Clément Lacroûte
Abstract:
Progress made in optical references, including ultra-stable Fabry-Perot cavities, optical frequency combs and optical atomic clocks, have driven the need for ultra-stable optical fiber networks. Telecom-wavelength ultra-pure optical signal transport has been demonstrated on distances ranging from the laboratory scale to the continental scale. In this manuscript, we present a Doppler-cancellation s…
▽ More
Progress made in optical references, including ultra-stable Fabry-Perot cavities, optical frequency combs and optical atomic clocks, have driven the need for ultra-stable optical fiber networks. Telecom-wavelength ultra-pure optical signal transport has been demonstrated on distances ranging from the laboratory scale to the continental scale. In this manuscript, we present a Doppler-cancellation setup based on a digital phase-locked loop for ultra-stable optical signal dissemination over fiber. The optical phase stabilization setup is based on a usual heterodyne Michelson-interferometer setup, while the Software Defined Radio (SDR) implementation of the phase-locked loop is based on a compact commercial board embedding a field programmable gate array, analog-to-digital and digital-to-analog converters. Using three different configurations including an undersampling method, we demonstrate a 20 m long fiber link with residual fractional frequency instability as low as $10^{-18}$ at 1000 s, and an optical phase noise of $-70$ dBc/Hz at 1 Hz with a telecom frequency carrier.
△ Less
Submitted 9 November, 2021;
originally announced November 2021.
-
Snowcover Survey over an Arctic Glacier Forefield: Contribution of Photogrammetry to Identify "Icing" Variability and Processes
Authors:
Eric Bernard,
Jean-Michel Friedt,
Madeleine Griselin
Abstract:
Current climate shift has significant impacts on both quality and quantity of snow precipitation. This directly influences spatial variability of the snowpack as well as cumulative snow height. Contemporary glacier retreat reorganizes periglacial morphology: while the glacier area decreases, the moraine area increases. The latter is becoming a new water storage potential almost as important as the…
▽ More
Current climate shift has significant impacts on both quality and quantity of snow precipitation. This directly influences spatial variability of the snowpack as well as cumulative snow height. Contemporary glacier retreat reorganizes periglacial morphology: while the glacier area decreases, the moraine area increases. The latter is becoming a new water storage potential almost as important as the glacier itself, but with a much more complex topography. This work hence fills one of the missing variables of the hydrological budget equation of an arctic glacier basin by providing an estimate of the snow water equivalent (SWE) of the moraine contribution. Such a result is achieved by investigating Structure from Motion (SfM) image processing applied to pictures collected from an Unmanned Aerial Vehicle (UAV) as a method to produce snow depth maps over the proglacial moraine area. Several UAV campaigns were carried out on a small glacial basin in Spitsbergen (Arctic): measurements were made at the maximum snow accumulation season (late April) while reference topography maps were acquired at the end of hydrological year (late September) when the moraine is mostly free of snow. Snow depth is determined from Digital Surface Model (DSM) subtraction. Using dedicated and natural ground control points for relative positioning of the DSMs, the relative DSM georeferencing with sub-meter accuracy removes the main source of uncertainty when assessing snow depth. For areas where snow is deposited on bare rock surfaces, the correlation between avalanche probe in-situ snow depth measurements and DSM differences is excellent. Differences in ice covered areas between the two measurement techniques are attributed to the different quantities measured.
△ Less
Submitted 20 May, 2021;
originally announced June 2021.
-
Sub-surface H2S detection by a Surface Acoustic Wave passive wireless sensor interrogated with a ground penetrating radar
Authors:
David Rabus,
Jean-Michel Friedt,
Lilia Arapan,
Simon Lamare,
Marc Baque,
Gregoire Audouin,
Frederic Cherioux
Abstract:
Long-term monitoring of organic pollutants in the soil is a major environmental challenge. We propose to meet this issue by the development of a polymer dedicated to selectively react with H2S, coating surface acoustic wave transducers designed as passive cooperative targets with the compound, and probing their response using Ground Penetrating RADAR, thus providing the capability to monitor the p…
▽ More
Long-term monitoring of organic pollutants in the soil is a major environmental challenge. We propose to meet this issue by the development of a polymer dedicated to selectively react with H2S, coating surface acoustic wave transducers designed as passive cooperative targets with the compound, and probing their response using Ground Penetrating RADAR, thus providing the capability to monitor the presence of H2S in the subsurface environment. The selectivity is brought by including lead(II) cation in a reticulated polymer matrix which can be deposited as a thin layer on a surface acoustic wave sensor. We demonstrate a signal enhancement mechanism in which water absorption magnifies the signal detection, making the sensor most sensitive to H2S in an underground environment saturated with moisture.
△ Less
Submitted 14 April, 2020;
originally announced May 2020.
-
Phase Sensitivity and Phase Noise of Cantilever-Type Magnetoelastic Sensors Based on the $Δ$E Effect
Authors:
Phillip Durdaut,
Enrico Rubiola,
Jean-Michel Friedt,
Cai Müller,
Benjamin Spetzler,
Christine Kirchhof,
Dirk Meyners,
Eckhard Quandt,
Franz Faupel,
Jeffrey McCord,
Reinhard Knöchel,
Michael Höft
Abstract:
Magnetoelastic sensors for the detection of low-frequency and low-amplitude magnetic fields are in the focus of research since more than 30 years. In order to minimize the limit of detection (LOD) of such sensor systems, it is of high importance to understand and to be able to quantify the relevant noise sources. In this contribution, cantilever-type electromechanic and magnetoelastic resonators,…
▽ More
Magnetoelastic sensors for the detection of low-frequency and low-amplitude magnetic fields are in the focus of research since more than 30 years. In order to minimize the limit of detection (LOD) of such sensor systems, it is of high importance to understand and to be able to quantify the relevant noise sources. In this contribution, cantilever-type electromechanic and magnetoelastic resonators, respectively, are comprehensively investigated and mathematically described not only with regard to their phase sensitivity but especially to the extent of the sensor-intrinsic phase noise. Both measurements and calculations reveal that the fundamental LOD is limited by additive phase noise due to thermal-mechanical noise of the resonator, i.e. by thermally induced random vibrations of the cantilever, and by thermal-electrical noise of the piezoelectric material. However, due to losses in the magnetic material parametric flicker phase noise arises, limiting the overall performance. In particular it is shown that the LOD is virtually independent of the magnetic sensitivity but is solely determined by the magnetic losses. Instead of the sensitivity, the magnetic losses, represented by the material's effective complex permeability, should be considered as the most important parameter for the further improvement of such sensors in the future. This implication is not only valid for magnetoelastic cantilevers but also applies to any type of magnetoelastic resonator.
△ Less
Submitted 2 March, 2020;
originally announced March 2020.
-
Noise Analysis of Open-Loop and Closed-Loop SAW Magnetic Field Sensor Systems
Authors:
Phillip Durdaut,
Anne Kittmann,
Enrico Rubiola,
Jean-Michel Friedt,
Eckhard Quandt,
Reinhard Knöchel,
Michael Höft
Abstract:
Transmission surface acoustic wave (SAW) sensors are widely used in various fields of application. In order to maximize the limit of detection (LOD) of such sensor systems, it is of high importance to understand and to be able to quantify the relevant noise sources. In this paper, low noise readout systems for the application with a SAW delay line magnetic field sensor in an open-loop and closed-l…
▽ More
Transmission surface acoustic wave (SAW) sensors are widely used in various fields of application. In order to maximize the limit of detection (LOD) of such sensor systems, it is of high importance to understand and to be able to quantify the relevant noise sources. In this paper, low noise readout systems for the application with a SAW delay line magnetic field sensor in an open-loop and closed-loop configuration are presented and analyzed with regard to their phase noise contribution. By applying oscillator phase noise theory to closed-loop sensor systems, it is shown that the phase noise of the SAW delay line oscillator can be predicted accurately. This allows the derivation of expressions for the limits of detection for both readout structures. Based on these equations, the equivalence between the LOD of open-loop and closed-loop SAW delay line readout can be shown analytically, assuming that the sensor contributes the dominant phase noise. This equality is verified by measurements. These results are applicable to all kinds of phase sensitive delay line sensors.
△ Less
Submitted 27 January, 2019; v1 submitted 5 January, 2019;
originally announced January 2019.
-
Equivalence of Open-Loop and Closed-Loop Operation of SAW Resonators and Delay Lines
Authors:
Phillip Durdaut,
Michael Höft,
Jean-Michel Friedt,
Enrico Rubiola
Abstract:
Surface acoustic wave (SAW) sensors in the form of two-port resonators or delay lines are widely used in various fields of application. Readout of such sensors is achieved by electronic systems operating either in an open-loop or in a closed-loop configuration. The mode of operation of the sensor system is usually chosen based on requirements like e.g. bandwidth, dynamic range, linearity, costs, a…
▽ More
Surface acoustic wave (SAW) sensors in the form of two-port resonators or delay lines are widely used in various fields of application. Readout of such sensors is achieved by electronic systems operating either in an open-loop or in a closed-loop configuration. The mode of operation of the sensor system is usually chosen based on requirements like e.g. bandwidth, dynamic range, linearity, costs, and immunity against environmental influences. Because the limit of detection (LOD) at the output of a sensor system is often one of the most important figures of merit, both readout structures, i.e. open-loop and closed-loop systems, are analyzed in terms of the minimum achievable LOD. Based on a comprehensive phase noise analysis of these structures for both, resonant sensors and delay line sensors, expressions for the various limits of detection are derived. Under generally valid conditions equivalence of open-loop and closed-loop operation is shown for both types of sensors. These results are not only valid for SAW devices but are also applicable to all kinds of phase sensitive sensors.
△ Less
Submitted 8 December, 2018;
originally announced December 2018.
-
A HBAR-oscillator-based 4.596~GHz frequency source: Application to a coherent population trapping Cs vapor cell atomic clock
Authors:
Thomas Daugey,
Jean-Michel Friedt,
Gilles Martin,
Rodolphe Boudot
Abstract:
This article reports on the design and characterization of a high-overtone bulk acoustic wave resonator (HBAR)-oscillator-based 4.596~GHz frequency source. A 2.298~GHz signal, generated by an oscillator constructed around a thermally-controlled two-port AlN-sapphire HBAR resonator with a Q-factor of 24000 at 68$^{\circ}$C, is frequency multiplied by 2 to 4.596~GHz, half of the Cs atom clock freque…
▽ More
This article reports on the design and characterization of a high-overtone bulk acoustic wave resonator (HBAR)-oscillator-based 4.596~GHz frequency source. A 2.298~GHz signal, generated by an oscillator constructed around a thermally-controlled two-port AlN-sapphire HBAR resonator with a Q-factor of 24000 at 68$^{\circ}$C, is frequency multiplied by 2 to 4.596~GHz, half of the Cs atom clock frequency. The temperature coefficient of frequency (TCF) of the HBAR is measured to be $-23$~ppm/$^{\circ}$C at 2.298~GHz. The measured phase noise of the 4.596~GHz source is $-105$~dBrad$^2$/Hz at 1~kHz offset and $-150$~dBrad$^2$/Hz at 100~kHz offset. The 4.596~GHz output signal is used as a local oscillator (LO) in a laboratory-prototype Cs microcell-based coherent population trapping (CPT) atomic clock. The signal is stabilized onto the atomic transition frequency by tuning finely a voltage-controlled phase shifter (VCPS) implemented in the 2.298~GHz HBAR-oscillator loop, preventing the need for a high-power-consuming direct digital synthesis (DDS). The short-term fractional frequency stability of the free-running oscillator is 1.8 $\times$ 10$^{-9}$ at one second integration time. In locked regime, the latter is improved in a preliminary proof-of-concept experiment at the level of 6.6 $\times$ 10$^{-11}~τ^{-1/2}$ up to a few seconds and found to be limited by the signal-to-noise ratio of the detected CPT resonance.
△ Less
Submitted 13 August, 2015;
originally announced August 2015.
-
High-overtone Bulk-Acoustic Resonator gravimetric sensitivity: towards wideband acoustic spectroscopy
Authors:
D. Rabus,
J. -M Friedt,
S. Ballandras,
T. Baron,
E. Lebrasseur,
E. Carry
Abstract:
In the context of direct detection sensors with compact dimensions, we investigate the gravimetric sensitivity of High-overtone Bulk Acoustic Resonators, through modeling of their acoustic characteristics and experiment. The high frequency characterizing such devices is expected to induce a significant effect when the acoustic field boundary conditions are modified by a thin adlayer. Furthermore,…
▽ More
In the context of direct detection sensors with compact dimensions, we investigate the gravimetric sensitivity of High-overtone Bulk Acoustic Resonators, through modeling of their acoustic characteristics and experiment. The high frequency characterizing such devices is expected to induce a significant effect when the acoustic field boundary conditions are modified by a thin adlayer. Furthermore, the multimode spectral characteristics is considered for wideband acoustic spectroscopy of the adlayer, once the gravimetric sensitivity dependence of the various overtones is established. Finally, means of improving the gravimetric sensitivity by confining the acoustic field in a low acoustic-impedance layer is theoretically established.
△ Less
Submitted 11 August, 2015;
originally announced August 2015.
-
Deriving ice thickness, glacier volume and bedrock morphology of the Austre Lovénbreen (Svalbard) using Ground-penetrating Radar
Authors:
Albane Saintenoy,
J. -M. Friedt,
Adam D. Booth,
F. Tolle,
E. Bernard,
Dominique Laffly,
C. Marlin,
M. Griselin
Abstract:
The Austre Lovénbreen is a 4.6 km2 glacier on the Archipelago of Svalbard (79 degrees N) that has been surveyed over the last 47 years in order of monitoring in particular the glacier evolution and associated hydrological phenomena in the context of nowadays global warming. A three-week field survey over April 2010 allowed for the acquisition of a dense mesh of Ground-penetrating Radar (GPR) data…
▽ More
The Austre Lovénbreen is a 4.6 km2 glacier on the Archipelago of Svalbard (79 degrees N) that has been surveyed over the last 47 years in order of monitoring in particular the glacier evolution and associated hydrological phenomena in the context of nowadays global warming. A three-week field survey over April 2010 allowed for the acquisition of a dense mesh of Ground-penetrating Radar (GPR) data with an average of 14683 points per km2 (67542 points total) on the glacier surface. The profiles were acquired using a Mala equipment with 100 MHz antennas, towed slowly enough to record on average every 0.3 m, a trace long enough to sound down to 189 m of ice. One profile was repeated with 50 MHz antenna to improve electromagnetic wave propagation depth in scattering media observed in the cirques closest to the slopes. The GPR was coupled to a GPS system to position traces. Each profile has been manually edited using standard GPR data processing including migration, to pick the reflection arrival time from the ice-bedrock interface. Snow cover was evaluated through 42 snow drilling measurements regularly spaced to cover all the glacier. These data were acquired at the time of the GPR survey and subsequently spatially interpolated using ordinary kriging. Using a snow velocity of 0.22 m/ns, the snow thickness was converted to electromagnetic wave travel-times and subtracted from the picked travel-times to the ice-bedrock interface. The resulting travel-times were converted to ice thickness using a velocity of 0.17 m/ns. The velocity uncertainty is discussed from a common mid-point profile analysis. A total of 67542 georeferenced data points with GPR-derived ice thicknesses, in addition to a glacier boundary line derived from satellite images taken during summer, were interpolated over the entire glacier surface using kriging with a 10 m grid size. Some uncertainty analysis were carried on and we calculated an averaged ice thickness of 76 m and a maximum depth of 164 m with a relative error of 11.9%. The volume of the glacier is derived as 0.3487$\pm$0.041 km3. Finally a 10-m grid map of the bedrock topography was derived by subtracting the ice thicknesses from a dual-frequency GPS-derived digital elevation model of the surface. These two datasets are the first step for modelling thermal evolution of the glacier and its bedrock, as well as the main hydrological network.
△ Less
Submitted 11 June, 2013;
originally announced June 2013.
-
In Situ Evaluation of Density, Viscosity and Thickness of Adsorbed Soft Layers by Combined Surface Acoustic Wave and Surface Plasmon Resonance
Authors:
L. Francis,
J. -M. Friedt,
C. Zhou,
P. Bertrand
Abstract:
We show the theoretical and experimental combination of acoustic and optical methods for the in situ quantitative evaluation of the density, the viscosity and the thickness of soft layers adsorbed on chemically tailored metal surfaces. For the highest sensitivity and an operation in liquids, a Love mode surface acoustic wave (SAW) sensor with a hydrophobized gold coated sensing area is the acous…
▽ More
We show the theoretical and experimental combination of acoustic and optical methods for the in situ quantitative evaluation of the density, the viscosity and the thickness of soft layers adsorbed on chemically tailored metal surfaces. For the highest sensitivity and an operation in liquids, a Love mode surface acoustic wave (SAW) sensor with a hydrophobized gold coated sensing area is the acoustic method, while surface plasmon resonance (SPR) on the same gold surface as the optical method is monitored simultaneously in a single set-up for the real-time and label-free measurement of the parameters of adsorbed soft layers, which means for layers with a predominant viscous behavior. A general mathematical modeling in equivalent viscoelastic transmission lines is presented to determine the correlation between experimental SAW signal shifts and the waveguide structure including the presence of the adsorbed layer and the supporting liquid from which it segregates. A methodology is presented to identify from SAW and SPR simulations the parameters representatives of the soft layer. During the absorption of a soft layer, thickness or viscosity changes are observed in the experimental ratio of the SAW signal attenuation to the SAW signal phase and are correlated with the theoretical model. As application example, the simulation method is applied to study the thermal behavior of physisorbed PNIPAAm, a polymer whose conformation is sensitive to temperature, under a cycling variation of temperature between 20 and 40 oC. Under the assumption of the bulk density and the bulk refractive index of PNIPAAm, thickness and viscosity of the film are obtained from simulations; the viscosity is correlated to the solvent content of the physisorbed layer.
△ Less
Submitted 28 April, 2006; v1 submitted 28 November, 2003;
originally announced November 2003.
-
Combined surface acoustic wave and surface plasmon resonance measurement of collagen and fibrinogen layers
Authors:
Jean-Michel Friedt,
Laurent Francis
Abstract:
We use an instrument combining optical (surface plasmon resonance) and acoustic (Love mode acoustic wave device) real-time measurements on a same surface for the identification of water content in collagen and fibrinogen protein layers. After calibration of the surface acoustic wave device sensitivity by copper electrodeposition, the bound mass and its physical properties -- density and optical in…
▽ More
We use an instrument combining optical (surface plasmon resonance) and acoustic (Love mode acoustic wave device) real-time measurements on a same surface for the identification of water content in collagen and fibrinogen protein layers. After calibration of the surface acoustic wave device sensitivity by copper electrodeposition, the bound mass and its physical properties -- density and optical index -- are extracted from the complementary measurement techniques and lead to thickness and water ratio values compatible with the observed signal shifts. Such results are especially usefully for protein layers with a high water content as shown here for collagen on an hydrophobic surface. We obtain the following results: collagen layers include 70+/-20 % water and are 16+/-3 to 19+/-3 nm thick for bulk concentrations ranging from 30 to 300 ug/ml. Fibrinogen layers include 50+/-10 % water for layer thicknesses in the 6+/-1.5 to 13+/-2 nm range when the bulk concentration is in the 46 to 460 ug/ml range.
△ Less
Submitted 20 March, 2016; v1 submitted 20 October, 2003;
originally announced October 2003.
-
Influence of electromagnetic interferences on the gravimetric sensitivity of surface acoustic waveguides
Authors:
L. Francis,
J. -M. Friedt,
R. De Palma,
P. Bertrand,
A. Campitelli
Abstract:
Surface acoustic waveguides are increasing in interest for (bio)chemical detection. The surface mass modification leads to measurable changes in the propagation properties of the waveguide. Among a wide variety of waveguides, Love mode has been investigated because of its high gravimetric sensitivity. The acoustic signal launched and detected in the waveguide by electrical transducers is accompa…
▽ More
Surface acoustic waveguides are increasing in interest for (bio)chemical detection. The surface mass modification leads to measurable changes in the propagation properties of the waveguide. Among a wide variety of waveguides, Love mode has been investigated because of its high gravimetric sensitivity. The acoustic signal launched and detected in the waveguide by electrical transducers is accompanied by an electromagnetic wave; the interaction of the two signals, easily enhanced by the open structure of the sensor, creates interference patterns in the transfer function of the sensor. The influence of these interferences on the gravimetric sensitivity is presented, whereby the structure of the entire sensor is modelled. We show that electromagnetic interferences generate an error in the experimental value of the sensitivity. This error is different for the open and the closed loop configurations of the sensor. The theoretical approach is completed by the experimentation of an actual Love mode sensor operated under liquid in open loop configuration. The experiment indicates that the interaction depends on the frequency and the mass modifications.
△ Less
Submitted 9 December, 2003; v1 submitted 24 July, 2003;
originally announced July 2003.
-
Simultaneous surface acoustic wave and surface plasmon resonance measurements: electrodeposition and biological interactions monitoring
Authors:
J. -M. Friedt,
L. Francis,
G. Reekmans,
R. De Palma,
A. Campitelli,
U. B. Sleytr
Abstract:
We present results from an instrument combining surface acoustic wave (SAW) propagation and surface plasmon resonance (SPR) measurements. The objective is to use two independent methods, the former based on adsorbed mass change measurements and the latter on surface dielectric properties variations, to identify physical properties of protein layers, and more specifically their water content. We…
▽ More
We present results from an instrument combining surface acoustic wave (SAW) propagation and surface plasmon resonance (SPR) measurements. The objective is to use two independent methods, the former based on adsorbed mass change measurements and the latter on surface dielectric properties variations, to identify physical properties of protein layers, and more specifically their water content. We display mass sensitivity calibration curves using electrodeposition of copper leading to a sensitivity in liquid of 150$\pm15$ $cm^2/g$ for the Love mode device used here, and the application to monitoring biological processes. The extraction of protein layer thickness and protein to water content ratio is also presented for S-layer proteins under investigation. We obtain respectively 4.7$\pm$0.7 nm and 75$\pm$15%.
△ Less
Submitted 4 July, 2003;
originally announced July 2003.