Data-driven performance optimization of gamma spectrometers with many channels
Authors:
Jayson R. Vavrek,
Hannah S. Parrilla,
Gabriel Aversano,
Mark S. Bandstra,
Micah Folsom,
Daniel Hellfeld
Abstract:
In gamma spectrometers with variable spectroscopic performance across many channels (e.g., many pixels or voxels), a tradeoff exists between including data from successively worse-performing readout channels and increasing efficiency. Brute-force calculation of the optimal set of included channels is exponentially infeasible as the number of channels grows, and approximate methods are required. In…
▽ More
In gamma spectrometers with variable spectroscopic performance across many channels (e.g., many pixels or voxels), a tradeoff exists between including data from successively worse-performing readout channels and increasing efficiency. Brute-force calculation of the optimal set of included channels is exponentially infeasible as the number of channels grows, and approximate methods are required. In this work, we present a data-driven framework for attempting to find near-optimal sets of included detector channels. The framework leverages non-negative matrix factorization (NMF) to learn the behavior of gamma spectra across the detector, and clusters similarly-performing detector channels together. Performance comparisons are then made between spectra with channel clusters removed, which is more feasible than brute force. The framework is general and can be applied to arbitrary, user-defined performance metrics depending on the application. We apply this framework to optimizing gamma spectra measured by H3D M400 CdZnTe spectrometers, which exhibit variable performance across their crystal volumes. In particular, we show several examples optimizing various performance metrics for uranium and plutonium gamma spectra in nondestructive assay for nuclear safeguards, and explore trends in performance vs.\ parameters such as clustering algorithm type. We also compare the NMF+clustering pipeline to several non-machine-learning algorithms, including several greedy algorithms. Overall, we find that the NMF+clustering pipeline tends to find the best-performing set of detector voxels, significantly improving over the un-optimized spectra, but that a greedy accumulation of spectra segmented by detector depth can in some cases give similar performance improvements in much less computation time.
△ Less
Submitted 9 April, 2025;
originally announced April 2025.
Characterization of a SiPM-based monolithic neutron scatter camera using dark counts
Authors:
J. Balajthy,
J. Brown,
E. Brubaker,
B. Cabrera-Palmer,
J. Cates,
B. L. Goldblum,
M. Folsom,
P. Hausladen,
K. Keefe,
J. Nattress,
V. Negut,
K. Nishimura,
J. Steele,
K. Ziock
Abstract:
We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm $\times$ 56 mm $\times$ 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomulti…
▽ More
We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm $\times$ 56 mm $\times$ 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. We calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be 128 ($\pm$4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2-by-4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.
△ Less
Submitted 29 February, 2024; v1 submitted 26 September, 2023;
originally announced September 2023.