Magnetization in superconducting corrector magnets and impact on luminosity-calibration scans in the Large Hadron Collider
Authors:
Agnieszka ChmieliĆska,
Lucio Fiscarelli,
Michi Hostettler,
Witold Kozanecki,
Stephan Russenschuck,
Ezio Todesco
Abstract:
Superconducting accelerator magnets have a nonlinear dependence of field on current due to the magnetization associated with the iron or with persistent currents in the superconducting filaments. This also gives rise to hysteresis phenomena that create a dependence of the field on the powering history. Magnetization effects are of particular importance for luminosity-calibration scans in the Large…
▽ More
Superconducting accelerator magnets have a nonlinear dependence of field on current due to the magnetization associated with the iron or with persistent currents in the superconducting filaments. This also gives rise to hysteresis phenomena that create a dependence of the field on the powering history. Magnetization effects are of particular importance for luminosity-calibration scans in the Large Hadron Collider, during which a small number of Nb-Ti superconducting orbit correctors are excited at low field and with frequent flipping of the sign of the current ramp. This paper focuses on the analysis of special measurements carried out to estimate these nonlinear effects under the special cycling conditions used in these luminosity scans. For standard powering cycles, we evaluate the effect of the main magnetization loop; for complex operational schemes, magnetization-branch transitions occur that depend on the details of the current cycle. The modelling of these effects is not included in the magnetic-field prediction software currently implemented in the LHC control system; here we present an approach to predict the transitions between the main magnetization branches. The final aim is to estimate the impact of magnetic hysteresis on the accuracy of luminosity-calibration scans.
△ Less
Submitted 26 July, 2023; v1 submitted 13 April, 2023;
originally announced April 2023.
Performance of a MQXF Nb3Sn Quadrupole Magnet Under Different Stress Level
Authors:
Susana Izquierdo Bermudez,
Giorgio Ambrosio,
Bernardo Bordini,
Nicolas Bourcey,
Paolo Ferracin,
Jose Ferradas Troitino,
Salvador Ferradas Troitino,
Lucio Fiscarelli,
Jerome Fleiter,
Michael Guinchard,
Franco Mangiarotti,
Juan Carlos Perez,
Eelis Takala,
Ezio Todesco
Abstract:
In a dipole or in a quadrupole accelerator magnet, the displacement of the coil turns induced by the electromagnetic forces can cause quenches limiting the magnet performance. For this reason, an azimuthal preload is applied to avoid azimuthal movements of the coil up to the required operational current. However, several tests showed that accelerator magnets can operate with a partial preload, i.e…
▽ More
In a dipole or in a quadrupole accelerator magnet, the displacement of the coil turns induced by the electromagnetic forces can cause quenches limiting the magnet performance. For this reason, an azimuthal preload is applied to avoid azimuthal movements of the coil up to the required operational current. However, several tests showed that accelerator magnets can operate with a partial preload, i.e. that coil unloading during the ramp does not prevent reaching higher currents. This issue is particularly relevant for Nb3Sn magnets, where the loads applied to the Nb3Sn filaments can reach the degradation limits of critical current. In order to investigate the impact of coil preload on the quench performance, the MQXFS6 short model quadrupole for the High Luminosity Upgrade was tested under an azimuthal preload at 80% of the short sample current, reaching 93% of short sample current at 1.9 K. The preload was then released to 60%, still showing ability to operate in the range of 80-85% of short sample current as required by HL-LHC project. With this lower preload, the ability of going above 90% of short sample was lost, and a significant training appeared above 85%. When the preload was restored to the original 80% value, the magnet reached with few quenches 95% of short sample (13.4 T peak field). Magnetic measurements confirm the larger movement of the coil in the case with lower preload, and agree with finite element simulations.
△ Less
Submitted 25 April, 2022;
originally announced April 2022.