-
Resolving non-equilibrium shape variations amongst millions of gold nanoparticles
Authors:
Zhou Shen,
Salah Awel,
Anton Barty,
Richard Bean,
Johan Bielecki,
Martin Bergemann,
Benedikt J. Daurer,
Tomas Ekeberg,
Armando D. Estillore,
Hans Fangohr,
Klaus Giewekemeyer,
Mark S. Hunter,
Mikhail Karnevskiy,
Richard A. Kirian,
Henry Kirkwood,
Yoonhee Kim,
Jayanath Koliyadu,
Holger Lange,
Romain Letrun,
Jannik Lübke,
Abhishek Mall,
Thomas Michelat,
Andrew J. Morgan,
Nils Roth,
Amit K. Samanta
, et al. (14 additional authors not shown)
Abstract:
Nanoparticles, exhibiting functionally relevant structural heterogeneity, are at the forefront of cutting-edge research. Now, high-throughput single-particle imaging (SPI) with x-ray free-electron lasers (XFELs) creates unprecedented opportunities for recovering the shape distributions of millions of particles that exhibit functionally relevant structural heterogeneity. To realize this potential,…
▽ More
Nanoparticles, exhibiting functionally relevant structural heterogeneity, are at the forefront of cutting-edge research. Now, high-throughput single-particle imaging (SPI) with x-ray free-electron lasers (XFELs) creates unprecedented opportunities for recovering the shape distributions of millions of particles that exhibit functionally relevant structural heterogeneity. To realize this potential, three challenges have to be overcome: (1) simultaneous parametrization of structural variability in real and reciprocal spaces; (2) efficiently inferring the latent parameters of each SPI measurement; (3) scaling up comparisons between $10^5$ structural models and $10^6$ XFEL-SPI measurements. Here, we describe how we overcame these three challenges to resolve the non-equilibrium shape distributions within millions of gold nanoparticles imaged at the European XFEL. These shape distributions allowed us to quantify the degree of asymmetry in these particles, discover a relatively stable `shape envelope' amongst nanoparticles, discern finite-size effects related to shape-controlling surfactants, and extrapolate nanoparticles' shapes to their idealized thermodynamic limit. Ultimately, these demonstrations show that XFEL SPI can help transform nanoparticle shape characterization from anecdotally interesting to statistically meaningful.
△ Less
Submitted 9 January, 2024;
originally announced January 2024.
-
On the use of multilayer Laue lenses with X-ray Free Electron Lasers
Authors:
Mauro Prasciolu,
Kevin T. Murray,
Nikolay Ivanov,
Holger Fleckenstein,
Martin Domaracký,
Luca Gelisio,
Fabian Trost,
Kartik Ayyer,
Dietrich Krebs,
Steve Aplin,
Salah Awel,
Ulrike Boesenberg,
Anton Barty,
Armando D. Estillore,
Matthias Fuchs,
Yaroslav Gevorkov,
Joerg Hallmann,
Chan Kim,
Juraj Knoška,
Jochen Küpper,
Chufeng Li,
Wei Lu,
Valerio Mariani,
Andrew J. Morgan,
Johannes Möller
, et al. (12 additional authors not shown)
Abstract:
Multilayer Laue lenses were used for the first time to focus x-rays from an X-ray Free Electron Laser (XFEL). In an experiment, which was performed at the European XFEL, we demonstrated focusing to a spot size of a few tens of nanometers. A series of runs in which the number of pulses per train was increased from 1 to 2, 3, 4, 5, 6, 7, 10, 20 and 30 pulses per train, all with a pulse separation of…
▽ More
Multilayer Laue lenses were used for the first time to focus x-rays from an X-ray Free Electron Laser (XFEL). In an experiment, which was performed at the European XFEL, we demonstrated focusing to a spot size of a few tens of nanometers. A series of runs in which the number of pulses per train was increased from 1 to 2, 3, 4, 5, 6, 7, 10, 20 and 30 pulses per train, all with a pulse separation of 3.55 us, was done using the same set of lenses. The increase in the number of pulses per train was accompanied with an increase of x-ray intensity (transmission) from 9% to 92% at 5 pulses per train, and then the transmission was reduced to 23.5 % when the pulses were increased further. The final working condition was 30 pulses per train and 23.5% transmission. Only at this condition we saw that the diffraction efficiency of the MLLs changed over the course of a pulse train, and this variation was reproducible from train to train. We present the procedure to align and characterize these lenses and discuss challenges working with the pulse trains from this unique x-ray source.
△ Less
Submitted 22 March, 2022;
originally announced March 2022.
-
Unsupervised learning approaches to characterize heterogeneous samples using X-ray single particle imaging
Authors:
Yulong Zhuang,
Salah Awel,
Anton Barty,
Richard Bean,
Johan Bielecki,
Martin Bergemann,
Benedikt J. Daurer,
Tomas Ekeberg,
Armando D. Estillore,
Hans Fangohr,
Klaus Giewekemeyer,
Mark S. Hunter,
Mikhail Karnevskiy,
Richard A. Kirian,
Henry Kirkwood,
Yoonhee Kim,
Jayanath Koliyadu,
Holger Lange,
Romain Letrun,
Jannik Lübke,
Abhishek Mall,
Thomas Michelat,
Andrew J. Morgan,
Nils Roth,
Amit K. Samanta
, et al. (17 additional authors not shown)
Abstract:
One of the outstanding analytical problems in X-ray single particle imaging (SPI) is the classification of structural heterogeneity, which is especially difficult given the low signal-to-noise ratios of individual patterns and that even identical objects can yield patterns that vary greatly when orientation is taken into consideration. We propose two methods which explicitly account for this orien…
▽ More
One of the outstanding analytical problems in X-ray single particle imaging (SPI) is the classification of structural heterogeneity, which is especially difficult given the low signal-to-noise ratios of individual patterns and that even identical objects can yield patterns that vary greatly when orientation is taken into consideration. We propose two methods which explicitly account for this orientation-induced variation and can robustly determine the structural landscape of a sample ensemble. The first, termed common-line principal component analysis (PCA) provides a rough classification which is essentially parameter-free and can be run automatically on any SPI dataset. The second method, utilizing variation auto-encoders (VAEs) can generate 3D structures of the objects at any point in the structural landscape. We implement both these methods in combination with the noise-tolerant expand-maximize-compress (EMC) algorithm and demonstrate its utility by applying it to an experimental dataset from gold nanoparticles with only a few thousand photons per pattern and recover both discrete structural classes as well as continuous deformations. These developments diverge from previous approaches of extracting reproducible subsets of patterns from a dataset and open up the possibility to move beyond studying homogeneous sample sets and study open questions on topics such as nanocrystal growth and dynamics as well as phase transitions which have not been externally triggered.
△ Less
Submitted 13 September, 2021;
originally announced September 2021.
-
Charge-state distribution of aerosolized nanoparticles
Authors:
Jannik Lübke,
Nils Roth,
Lena Worbs,
Daniel A. Horke,
Armando D. Estillore,
Amit K. Samanta,
Jochen Küpper
Abstract:
In single particle imaging experiments, beams of individual nanoparticles are exposed to intense pulses of x-rays from free-electron lasers to record diffraction patterns of single, isolated molecules. The reconstruction for structure determination relies on signal from many identical particles. Therefore, well-defined-sample delivery conditions are desired in order to achieve sample uniformity, i…
▽ More
In single particle imaging experiments, beams of individual nanoparticles are exposed to intense pulses of x-rays from free-electron lasers to record diffraction patterns of single, isolated molecules. The reconstruction for structure determination relies on signal from many identical particles. Therefore, well-defined-sample delivery conditions are desired in order to achieve sample uniformity, including avoidance of charge polydispersity. We have observed charging of 220 nm polystyrene particles in an aerosol beam created by a gas-dynamic virtual nozzle focusing technique, without intentional charging of the nanoparticles. Here, we present a deflection method for detecting and characterizing the charge states of a beam of aerosolized nanoparticles. Our analysis of the observed charge-state distribution using optical light-sheet localization microscopy and quantitative particle trajectory simulations is consistent with previous descriptions of skewed charging probabilities of triboelectrically charged nanoparticles.
△ Less
Submitted 10 August, 2021;
originally announced August 2021.
-
Optimizing the geometry of aerodynamic lens injectors for single-particle coherent diffractive imaging of gold nanoparticles
Authors:
Lena Worbs,
Nils Roth,
Jannik Lübke,
Armando D. Estillore,
P. Lourdu Xavier,
Amit K. Samanta,
Jochen Küpper
Abstract:
Single-particle x-ray diffractive imaging (SPI) of small (bio-)nanoparticles (NPs) requires optimized injectors to collect sufficient diffraction patterns to reconstruct the NP structure with high resolution. Typically, aerodynamic-lens-stack injectors are used for single NP injection. However, current injectors were developed for larger NPs ($\gg\!100$ nm) and their ability to generate high-densi…
▽ More
Single-particle x-ray diffractive imaging (SPI) of small (bio-)nanoparticles (NPs) requires optimized injectors to collect sufficient diffraction patterns to reconstruct the NP structure with high resolution. Typically, aerodynamic-lens-stack injectors are used for single NP injection. However, current injectors were developed for larger NPs ($\gg\!100$ nm) and their ability to generate high-density NP beams suffers with decreasing NP size. Here, an aerodynamic-lens-stack injector with variable geometry and the geometry-optimization procedure are presented. The optimization for 50 nm gold NP (AuNP) injection using a numerical simulation infrastructure capable of calculating the carrier gas flow and the particle trajectories through the injector is introduced. The simulations are experimentally validated using spherical AuNPs and sucrose NPs. In addition, the optimized injector is compared to the standard-installation "Uppsala-injector" for AuNPs and results for these heavy particles show a shift in the particle-beam focus position rather than a change in beam size, which results in a lower gas background for the optimized injector. Optimized aerodynamic-lens stack injectors will allow to increase NP beam density, reduce the gas background, discover the limits of current injectors, and contribute to structure determination of small NPs using SPI.
△ Less
Submitted 31 May, 2021;
originally announced May 2021.
-
New aerodynamic lens injector for single particle diffractive imaging
Authors:
Nils Roth,
Daniel A. Horke,
Jannik Lübke,
Amit K. Samanta,
Armando D. Estillore,
Lena Worbs,
Nicolai Pohlman,
Kartik Ayyer,
Andrew Morgan,
Holger Fleckenstein,
Martin Domaracky,
Benjamin Erk,
Christopher Passow,
Jonathan Correa,
Oleksandr Yefanov,
Anton Barty,
Saša Bajt,
Richard A. Kirian,
Henry N. Chapman,
Jochen Küpper
Abstract:
An aerodynamic lens injector was developed specifically for the needs of single-particle diffractive imaging experiments at free-electron lasers. Its design allows for quick changes of injector geometries and focusing properties in order to optimize injection for specific individual samples. Here, we present results of its first use at the FLASH free-electron-laser facility. Recorded diffraction p…
▽ More
An aerodynamic lens injector was developed specifically for the needs of single-particle diffractive imaging experiments at free-electron lasers. Its design allows for quick changes of injector geometries and focusing properties in order to optimize injection for specific individual samples. Here, we present results of its first use at the FLASH free-electron-laser facility. Recorded diffraction patterns of polystyrene spheres are modeled using Mie scattering, which allowed for the characterization of the particle beam under diffractive-imaging conditions and yield good agreement with particle-trajectory simulations.
△ Less
Submitted 21 December, 2020;
originally announced December 2020.
-
3D diffractive imaging of nanoparticle ensembles using an X-ray laser
Authors:
Kartik Ayyer,
P. Lourdu Xavier,
Johan Bielecki,
Zhou Shen,
Benedikt J. Daurer,
Amit K. Samanta,
Salah Awel,
Richard Bean,
Anton Barty,
Tomas Ekeberg,
Armando D. Estillore,
Klaus Giewekemeyer,
Mark S. Hunter,
Richard A. Kirian,
Henry Kirkwood,
Yoonhee Kim,
Jayanath Koliyadu,
Holger Lange,
Romain Letruin,
Jannik Lübke,
Andrew J. Morgan,
Nils Roth,
Tokushi Sato,
Marcin Sikorski,
Florian Schulz
, et al. (12 additional authors not shown)
Abstract:
We report the 3D structure determination of gold nanoparticles (AuNPs) by X-ray single particle imaging (SPI). Around 10 million diffraction patterns from gold nanoparticles were measured in less than 100 hours of beam time, more than 100 times the amount of data in any single prior SPI experiment, using the new capabilities of the European X-ray free electron laser which allow measurements of 150…
▽ More
We report the 3D structure determination of gold nanoparticles (AuNPs) by X-ray single particle imaging (SPI). Around 10 million diffraction patterns from gold nanoparticles were measured in less than 100 hours of beam time, more than 100 times the amount of data in any single prior SPI experiment, using the new capabilities of the European X-ray free electron laser which allow measurements of 1500 frames per second. A classification and structural sorting method was developed to disentangle the heterogeneity of the particles and to obtain a resolution of better than 3 nm. With these new experimental and analytical developments, we have entered a new era for the SPI method and the path towards close-to-atomic resolution imaging of biomolecules is apparent.
△ Less
Submitted 17 July, 2020;
originally announced July 2020.
-
Controlled beams of shockfrozen, isolated, biological and artificial nanoparticles
Authors:
Amit K. Samanta,
Muhamed Amin,
Armando D. Estillore,
Nils Roth,
Lena Worbs,
Daniel A. Horke,
Jochen Küpper
Abstract:
X-ray free-electron lasers (XFELs) promise the diffractive imaging of single molecules and nanoparticles with atomic spatial resolution. This relies on the averaging of millions of diffraction patterns of identical particles, which should ideally be isolated in the gas phase and preserved in their native structure. Here, we demonstrated that polystyrene nanospheres and Cydia pomonella granulovirus…
▽ More
X-ray free-electron lasers (XFELs) promise the diffractive imaging of single molecules and nanoparticles with atomic spatial resolution. This relies on the averaging of millions of diffraction patterns of identical particles, which should ideally be isolated in the gas phase and preserved in their native structure. Here, we demonstrated that polystyrene nanospheres and Cydia pomonella granulovirus can be transferred into the gas phase, isolated, and very quickly shockfrozen, i.e. cooled to 4~K within microseconds in a helium-buffer-gas cell, much faster than state-of-the-art approaches. Nanoparticle beams emerging from the cell were characterized using particle-localization microscopy with light-sheet illumination, which allowed for the full reconstruction of the particle beams, focused to $<100\:μ\text{m}$, as well as for the determination of particle flux and number density. The experimental results were quantitatively reproduced and rationalized through particle-trajectory simulations. We propose an optimized setup with cooling rates for few-nanometers particles on nanoseconds timescales. The produced beams of shockfrozen isolated nanoparticles provide a breakthrough in sample delivery, e.g. for diffractive imaging and microscopy or low-temperature nanoscience.
△ Less
Submitted 3 April, 2020; v1 submitted 28 October, 2019;
originally announced October 2019.