Resection cavity auto-contouring for patients with pediatric medulloblastoma using only CT information
Authors:
Soleil Hernandez,
Callistus Nguyen,
Skylar Gay,
Jack Duryea,
Rebecca Howell,
David Fuentes,
Jeannette Parkes,
Hester Burger,
Carlos Cardenas,
Arnold C. Paulino,
Julianne Pollard-Larkin,
Laurence Court
Abstract:
Purpose: Target delineation for radiation therapy is a time-consuming and complex task. Autocontouring gross tumor volumes (GTVs) has been shown to increase efficiency. However, there is limited literature on post-operative target delineation, particularly for CT-based studies. To this end, we trained a CT-based autocontouring model to contour the post-operative GTV of pediatric patients with medu…
▽ More
Purpose: Target delineation for radiation therapy is a time-consuming and complex task. Autocontouring gross tumor volumes (GTVs) has been shown to increase efficiency. However, there is limited literature on post-operative target delineation, particularly for CT-based studies. To this end, we trained a CT-based autocontouring model to contour the post-operative GTV of pediatric patients with medulloblastoma.
Methods: 104 retrospective pediatric CT scans were used to train a GTV auto-contouring model. 80 patients were then preselected for contour visibility, continuity, and location to train an additional model. Each GTV was manually annotated with a visibility score based on the number of slices with a visible GTV (1 = <25%, 2 = 25%-50%, 3 = >50%-75%, and 4 = >75%-100%). Contrast and the contrast-to-noise ratio (CNR) were calculated for the GTV contour with respect to a cropped background image. Both models were tested on the original and pre-selected testing sets. The resulting surface and overlap metrics were calculated comparing the clinical and autocontoured GTVs and the corresponding clinical target volumes (CTVs).
Results: 80 patients were pre-selected to have a continuous GTV within the posterior fossa. Of these, 7, 41, 21, and 11 were visibly scored as 4, 3, 2, and 1, respectively. The contrast and CNR removed an additional 11 and 20 patients from the dataset, respectively. The Dice similarity coefficients (DSC) were 0.61 +/- 0.29 and 0.67 +/- 0.22 on the models without pre-selected training data and 0.55 +/- 13.01 and 0.83 +/- 0.17 on the models with pre-selected data, respectively. The DSC on the CTV expansions were 0.90 +/- 0.13. Conclusion: We automatically contoured continuous GTVs within the posterior fossa on scans that had contrast >=10 HU. CT-Based auto-contouring algorithms have potential to positively impact centers with limited MRI access.
△ Less
Submitted 19 December, 2022;
originally announced December 2022.
-
Measurement of Decay Parameters for $Ξ^{-} \to Λπ^{-}$ Decay
Authors:
FNAL E756 Collaboration,
A. Chakravorty,
H. T. Diehl,
J. Duryea,
G. Guglielmo,
K. Heller,
P. M. Ho,
C. James,
K. Johns,
D. M Kaplan,
M. J. Longo,
K. B. Luk,
R. Rameika,
H. A. Rubin,
S. Teige,
G. B. Thomson,
Y. Zou
Abstract:
Based on 1.35 million polarized $Ξ^{-}$ events, we measure the parameter $φ_Ξ$ to be $-1.61^{\circ} \pm 2.66^{\circ} \pm 0.37^{\circ}$ for $Ξ^{-} \to Λπ^{-}$ decay. New results for the parameters $β_Ξ$ and $γ_Ξ$ are also presented. Assuming that the CP-violating phase-shift difference is negligible, we deduce the strong phase-shift difference between the P-wave and S-wave amplitudes of the $Λπ$…
▽ More
Based on 1.35 million polarized $Ξ^{-}$ events, we measure the parameter $φ_Ξ$ to be $-1.61^{\circ} \pm 2.66^{\circ} \pm 0.37^{\circ}$ for $Ξ^{-} \to Λπ^{-}$ decay. New results for the parameters $β_Ξ$ and $γ_Ξ$ are also presented. Assuming that the CP-violating phase-shift difference is negligible, we deduce the strong phase-shift difference between the P-wave and S-wave amplitudes of the $Λπ$ final state to be $3.17^{\circ} \pm 5.28^{\circ} \pm 0.73^{\circ}$. This strong phase-shift difference reduces the theoretical uncertainty in estimating the level of CP violation in $Ξ$-hyperon decay.
△ Less
Submitted 23 June, 2003;
originally announced June 2003.
-
Search for Direct CP Violation in Non-Leptonic Decays of Charged $Ξ$ and $Λ$ Hyperons
Authors:
K. B. Luk,
H. T. Diehl,
J. Duryea,
G. Guglielmo,
K. Heller,
P. M. Ho,
C. James,
K. Johns,
M. J. Longo,
R. Rameika,
S. Teige,
G. B. Thomson
Abstract:
A search for direct CP violation in the non-leptonic decays of hyperons has been performed. In comparing the product of the decay parameters, $α_Ξα_Λ$, in terms of an asymmetry parameter, $A_{ΞΛ}$, between hyperons and anti-hyperons in the charged $Ξ\to Λπ$ and $Λ\to p π$ decay sequence, we found no evidence of direct CP violations. The parameter $A_{ΞΛ}$ was measured to be $0.012 \pm 0.014$.
A search for direct CP violation in the non-leptonic decays of hyperons has been performed. In comparing the product of the decay parameters, $α_Ξα_Λ$, in terms of an asymmetry parameter, $A_{ΞΛ}$, between hyperons and anti-hyperons in the charged $Ξ\to Λπ$ and $Λ\to p π$ decay sequence, we found no evidence of direct CP violations. The parameter $A_{ΞΛ}$ was measured to be $0.012 \pm 0.014$.
△ Less
Submitted 17 July, 2000;
originally announced July 2000.