-
Modification of the scattering mechanisms in bilayer graphene in proximity to a molecular thin film probed in the mesoscopic regime
Authors:
Anise Mansour,
Deanna Diaz,
Movindu Kawshan Dissanayake,
Erin Henkhaus,
Jungyoun Cho,
Vinh Tran,
Francisco Ramirez,
Eric Corona-Oceguera,
Joshua Luna,
Kenta Kodama,
Yueyun Chen,
Ho Chan,
Jacob Weber,
Blake Koford,
Patrick Barfield,
Maya Martinez,
Kenji Watanabe,
Takashi Taniguchi,
B. C. Regan,
Matthew Mecklenburg,
Thomas Gredig,
Claudia Ojeda-Aristizabal
Abstract:
Quantum coherent effects can be probed in multilayer graphene through electronic transport measurements at low temperatures. In particular, bilayer graphene is known to be susceptible to quantum interference corrections of the conductivity, presenting weak localization at all electronic densities, and dependent on different scattering mechanisms as well as on the trigonal warping of the electron d…
▽ More
Quantum coherent effects can be probed in multilayer graphene through electronic transport measurements at low temperatures. In particular, bilayer graphene is known to be susceptible to quantum interference corrections of the conductivity, presenting weak localization at all electronic densities, and dependent on different scattering mechanisms as well as on the trigonal warping of the electron dispersion near the K and K' valleys. Proximity effects with a molecular thin film influence these scattering mechanisms, which can be quantified through the known theory of magnetoconductance for bilayer graphene. Here, we present weak localization measurements in a copper-phthalocyanine / bilayer graphene / h-BN heterostructure that suggest an important suppression of trigonal warping effects in bilayer graphene (BLG), restoring the manifestation of the chirality of the charge carriers in the localization properties of BLG. Additionally, we observe a charge transfer of 3.6$\times$10$^{12}$cm$^{-2}$ from the BLG to the molecules, as well as a very small degradation of the mobility of the BLG/h-BN heterostructure upon the deposition of copper phthalocyanine (CuPc). The molecular arrangement of the CuPc thin film is characterized in a control sample through transmission electron microscopy, that we relate to the electronic transport results.
△ Less
Submitted 29 April, 2025;
originally announced April 2025.
-
Simulating Negative Hydrogen ion acceleration in LINAC-4 using Unity 3D
Authors:
D. M. C. M. K. Dissanayake,
N. Wickramage,
K. M. Liyanage,
K. A. S. Lakshan
Abstract:
The Linear Accelerator 4 (LINAC 4) is designed to accelerate negative hydrogen ions to high energies for injection into the Large Hadron Collider (LHC), where it has been supplying proton beams since 2020. LINAC 4 accelerates negative hydrogen ions to 160 MeV. The accelerator pulses 400 microsecond bursts of negative hydrogen ions. A complex process is processed in this machine to achieve the requ…
▽ More
The Linear Accelerator 4 (LINAC 4) is designed to accelerate negative hydrogen ions to high energies for injection into the Large Hadron Collider (LHC), where it has been supplying proton beams since 2020. LINAC 4 accelerates negative hydrogen ions to 160 MeV. The accelerator pulses 400 microsecond bursts of negative hydrogen ions. A complex process is processed in this machine to achieve the required energy and simulating the machine is beneficial for improved understanding, visualization, educational purposes, and for training and skill development. Normally, high performance, specialized software is needed to simulate the intricate dynamics of ion acceleration. However, our goal is to develop an interactive, realtime model that effectively simulates the acceleration of negative H ions through the LINAC 4 stages by utilizing simulation and visualization capabilities of Unity 3D. In this study, Electric fields generated by each unit of LINAC 4 are assumed as known wave functions, and instantaneous velocity is calculated using fundamental physics laws. 3D structures were developed to approximate scale, and the user can control the frequency of the electric field to adjust the velocity, allowing the particle to reach the required energy level at the end. A time based pattern is used in the Chopper line, where the user can change the beam on time. Users can visualize the particle beam path and approximated graphical representation of the velocity variation in LINAC 4 under controllable electric fields and different time based chopping patterns generated by the chopper line. This simulation creates an accessible platform for students, researchers, and technicians to learn about processes of LINAC 4 in an interactive manner. It also guides users to better understand complex acceleration physics by allowing them to visualize the ion pathways, energy changes, and field interactions.
△ Less
Submitted 28 February, 2025;
originally announced March 2025.
-
A self-supervised text-vision framework for automated brain abnormality detection
Authors:
David A. Wood,
Emily Guilhem,
Sina Kafiabadi,
Ayisha Al Busaidi,
Kishan Dissanayake,
Ahmed Hammam,
Nina Mansoor,
Matthew Townend,
Siddharth Agarwal,
Yiran Wei,
Asif Mazumder,
Gareth J. Barker,
Peter Sasieni,
Sebastien Ourselin,
James H. Cole,
Thomas C. Booth
Abstract:
Artificial neural networks trained on large, expert-labelled datasets are considered state-of-the-art for a range of medical image recognition tasks. However, categorically labelled datasets are time-consuming to generate and constrain classification to a pre-defined, fixed set of classes. For neuroradiological applications in particular, this represents a barrier to clinical adoption. To address…
▽ More
Artificial neural networks trained on large, expert-labelled datasets are considered state-of-the-art for a range of medical image recognition tasks. However, categorically labelled datasets are time-consuming to generate and constrain classification to a pre-defined, fixed set of classes. For neuroradiological applications in particular, this represents a barrier to clinical adoption. To address these challenges, we present a self-supervised text-vision framework that learns to detect clinically relevant abnormalities in brain MRI scans by directly leveraging the rich information contained in accompanying free-text neuroradiology reports. Our training approach consisted of two-steps. First, a dedicated neuroradiological language model - NeuroBERT - was trained to generate fixed-dimensional vector representations of neuroradiology reports (N = 50,523) via domain-specific self-supervised learning tasks. Next, convolutional neural networks (one per MRI sequence) learnt to map individual brain scans to their corresponding text vector representations by optimising a mean square error loss. Once trained, our text-vision framework can be used to detect abnormalities in unreported brain MRI examinations by scoring scans against suitable query sentences (e.g., 'there is an acute stroke', 'there is hydrocephalus' etc.), enabling a range of classification-based applications including automated triage. Potentially, our framework could also serve as a clinical decision support tool, not only by suggesting findings to radiologists and detecting errors in provisional reports, but also by retrieving and displaying examples of pathologies from historical examinations that could be relevant to the current case based on textual descriptors.
△ Less
Submitted 11 June, 2024; v1 submitted 4 May, 2024;
originally announced May 2024.
-
IMU-based Modularized Wearable Device for Human Motion Classification
Authors:
Sahan Wijethunga,
Shehan Kaushalya Senavirathna,
Kavishka Dissanayake,
Janith Bandara Senanayake,
Eranda Somathilake,
Upekha Hansanie Delay,
Roshan Indika Godaliyadda,
Mervyn Parakrama Ekanayake,
Janaka Wijayakulasooriya
Abstract:
Human motion analysis is used in many different fields and applications. Currently, existing systems either focus on one single limb or one single class of movements. Many proposed systems are designed to be used in an indoor controlled environment and must possess good technical know-how to operate. To improve mobility, a less restrictive, modularized, and simple Inertial Measurement units based…
▽ More
Human motion analysis is used in many different fields and applications. Currently, existing systems either focus on one single limb or one single class of movements. Many proposed systems are designed to be used in an indoor controlled environment and must possess good technical know-how to operate. To improve mobility, a less restrictive, modularized, and simple Inertial Measurement units based system is proposed that can be worn separately and combined. This allows the user to measure singular limb movements separately and also monitor whole body movements over a prolonged period at any given time while not restricted to a controlled environment. For proper analysis, data is conditioned and pre-processed through possible five stages namely power-based, clustering index-based, Kalman filtering, distance-measure-based, and PCA-based dimension reduction. Different combinations of the above stages are analyzed using machine learning algorithms for selected case studies namely hand gesture recognition and environment and shoe parameter-based walking pattern analysis to validate the performance capability of the proposed wearable device and multi-stage algorithms. The results of the case studies show that distance-measure-based and PCA-based dimension reduction will significantly improve human motion identification accuracy. This is further improved with the introduction of the Kalman filter. An LSTM neural network is proposed as an alternate classifier and the results indicate that it is a robust classifier for human motion recognition. As the results indicate, the proposed wearable device architecture and multi-stage algorithms are cable of distinguishing between subtle human limb movements making it a viable tool for human motion analysis.
△ Less
Submitted 29 March, 2023;
originally announced March 2023.