-
Humanity's Last Exam
Authors:
Long Phan,
Alice Gatti,
Ziwen Han,
Nathaniel Li,
Josephina Hu,
Hugh Zhang,
Chen Bo Calvin Zhang,
Mohamed Shaaban,
John Ling,
Sean Shi,
Michael Choi,
Anish Agrawal,
Arnav Chopra,
Adam Khoja,
Ryan Kim,
Richard Ren,
Jason Hausenloy,
Oliver Zhang,
Mantas Mazeika,
Dmitry Dodonov,
Tung Nguyen,
Jaeho Lee,
Daron Anderson,
Mikhail Doroshenko,
Alun Cennyth Stokes
, et al. (1084 additional authors not shown)
Abstract:
Benchmarks are important tools for tracking the rapid advancements in large language model (LLM) capabilities. However, benchmarks are not keeping pace in difficulty: LLMs now achieve over 90\% accuracy on popular benchmarks like MMLU, limiting informed measurement of state-of-the-art LLM capabilities. In response, we introduce Humanity's Last Exam (HLE), a multi-modal benchmark at the frontier of…
▽ More
Benchmarks are important tools for tracking the rapid advancements in large language model (LLM) capabilities. However, benchmarks are not keeping pace in difficulty: LLMs now achieve over 90\% accuracy on popular benchmarks like MMLU, limiting informed measurement of state-of-the-art LLM capabilities. In response, we introduce Humanity's Last Exam (HLE), a multi-modal benchmark at the frontier of human knowledge, designed to be the final closed-ended academic benchmark of its kind with broad subject coverage. HLE consists of 2,500 questions across dozens of subjects, including mathematics, humanities, and the natural sciences. HLE is developed globally by subject-matter experts and consists of multiple-choice and short-answer questions suitable for automated grading. Each question has a known solution that is unambiguous and easily verifiable, but cannot be quickly answered via internet retrieval. State-of-the-art LLMs demonstrate low accuracy and calibration on HLE, highlighting a significant gap between current LLM capabilities and the expert human frontier on closed-ended academic questions. To inform research and policymaking upon a clear understanding of model capabilities, we publicly release HLE at https://lastexam.ai.
△ Less
Submitted 19 April, 2025; v1 submitted 24 January, 2025;
originally announced January 2025.
-
Optimizing Photoplethysmography-Based Sleep Staging Models by Leveraging Temporal Context for Wearable Devices Applications
Authors:
Joseph A. P. Quino,
Diego A. C. Cardenas,
Marcelo A. F. Toledo,
Felipe M. Dias,
Estela Ribeiro,
Jose E. Krieger,
Marco A. Gutierrez
Abstract:
Accurate sleep stage classification is crucial for diagnosing sleep disorders and evaluating sleep quality. While polysomnography (PSG) remains the gold standard, photoplethysmography (PPG) is more practical due to its affordability and widespread use in wearable devices. However, state-of-the-art sleep staging methods often require prolonged continuous signal acquisition, making them impractical…
▽ More
Accurate sleep stage classification is crucial for diagnosing sleep disorders and evaluating sleep quality. While polysomnography (PSG) remains the gold standard, photoplethysmography (PPG) is more practical due to its affordability and widespread use in wearable devices. However, state-of-the-art sleep staging methods often require prolonged continuous signal acquisition, making them impractical for wearable devices due to high energy consumption. Shorter signal acquisitions are more feasible but less accurate. Our work proposes an adapted sleep staging model based on top-performing state-of-the-art methods and evaluates its performance with different PPG segment sizes. We concatenate 30-second PPG segments over 15-minute intervals to leverage longer segment contexts. This approach achieved an accuracy of 0.75, a Cohen's Kappa of 0.60, an F1-Weighted score of 0.74, and an F1-Macro score of 0.60. Although reducing segment size decreased sensitivity for deep and REM stages, our strategy outperformed single 30-second window methods, particularly for these stages.
△ Less
Submitted 1 October, 2024;
originally announced October 2024.
-
Exploring the limitations of blood pressure estimation using the photoplethysmography signal
Authors:
Felipe M. Dias,
Diego A. C. Cardenas,
Marcelo A. F. Toledo,
Filipe A. C. Oliveira,
Estela Ribeiro,
Jose E. Krieger,
Marco A. Gutierrez
Abstract:
Hypertension, a leading contributor to cardiovascular morbidity, underscores the need for accurate and continuous blood pressure (BP) monitoring. Photoplethysmography (PPG) presents a promising approach to this end. However, the precision of BP estimates derived from PPG signals has been the subject of ongoing debate, necessitating a comprehensive evaluation of their effectiveness and constraints.…
▽ More
Hypertension, a leading contributor to cardiovascular morbidity, underscores the need for accurate and continuous blood pressure (BP) monitoring. Photoplethysmography (PPG) presents a promising approach to this end. However, the precision of BP estimates derived from PPG signals has been the subject of ongoing debate, necessitating a comprehensive evaluation of their effectiveness and constraints. We developed a calibration-based Siamese ResNet model for BP estimation, using a signal input paired with a reference BP reading. We compared the use of normalized PPG (N-PPG) against the normalized Invasive Arterial Blood Pressure (N-IABP) signals as input. The N-IABP signals do not directly present systolic and diastolic values but theoretically provide a more accurate BP measure than PPG signals since it is a direct pressure sensor inside the body. Our strategy establishes a critical benchmark for PPG performance, realistically calibrating expectations for PPG's BP estimation capabilities. Nonetheless, we compared the performance of our models using different signal-filtering conditions to evaluate the impact of filtering on the results. We evaluated our method using the AAMI and the BHS standards employing the VitalDB dataset. The N-IABP signals meet with AAMI standards for both Systolic Blood Pressure (SBP) and Diastolic Blood Pressure (DBP), with errors of 1.29+-6.33mmHg for systolic pressure and 1.17+-5.78mmHg for systolic and diastolic pressure respectively for the raw N-IABP signal. In contrast, N-PPG signals, in their best setup, exhibited inferior performance than N-IABP, presenting 1.49+-11.82mmHg and 0.89+-7.27mmHg for systolic and diastolic pressure respectively. Our findings highlight the potential and limitations of employing PPG for BP estimation, showing that these signals contain information correlated to BP but may not be sufficient for predicting it accurately.
△ Less
Submitted 9 April, 2024;
originally announced April 2024.
-
A machine-learning sleep-wake classification model using a reduced number of features derived from photoplethysmography and activity signals
Authors:
Douglas A. Almeida,
Felipe M. Dias,
Marcelo A. F. Toledo,
Diego A. C. Cardenas,
Filipe A. C. Oliveira,
Estela Ribeiro,
Jose E. Krieger,
Marco A. Gutierrez
Abstract:
Sleep is a crucial aspect of our overall health and well-being. It plays a vital role in regulating our mental and physical health, impacting our mood, memory, and cognitive function to our physical resilience and immune system. The classification of sleep stages is a mandatory step to assess sleep quality, providing the metrics to estimate the quality of sleep and how well our body is functioning…
▽ More
Sleep is a crucial aspect of our overall health and well-being. It plays a vital role in regulating our mental and physical health, impacting our mood, memory, and cognitive function to our physical resilience and immune system. The classification of sleep stages is a mandatory step to assess sleep quality, providing the metrics to estimate the quality of sleep and how well our body is functioning during this essential period of rest. Photoplethysmography (PPG) has been demonstrated to be an effective signal for sleep stage inference, meaning it can be used on its own or in a combination with others signals to determine sleep stage. This information is valuable in identifying potential sleep issues and developing strategies to improve sleep quality and overall health. In this work, we present a machine learning sleep-wake classification model based on the eXtreme Gradient Boosting (XGBoost) algorithm and features extracted from PPG signal and activity counts. The performance of our method was comparable to current state-of-the-art methods with a Sensitivity of 91.15 $\pm$ 1.16%, Specificity of 53.66 $\pm$ 1.12%, F1-score of 83.88 $\pm$ 0.56%, and Kappa of 48.0 $\pm$ 0.86%. Our method offers a significant improvement over other approaches as it uses a reduced number of features, making it suitable for implementation in wearable devices that have limited computational power.
△ Less
Submitted 7 August, 2023;
originally announced August 2023.
-
Machine Learning-Based Diabetes Detection Using Photoplethysmography Signal Features
Authors:
Filipe A. C. Oliveira,
Felipe M. Dias,
Marcelo A. F. Toledo,
Diego A. C. Cardenas,
Douglas A. Almeida,
Estela Ribeiro,
Jose E. Krieger,
Marco A. Gutierrez
Abstract:
Diabetes is a prevalent chronic condition that compromises the health of millions of people worldwide. Minimally invasive methods are needed to prevent and control diabetes but most devices for measuring glucose levels are invasive and not amenable for continuous monitoring. Here, we present an alternative method to overcome these shortcomings based on non-invasive optical photoplethysmography (PP…
▽ More
Diabetes is a prevalent chronic condition that compromises the health of millions of people worldwide. Minimally invasive methods are needed to prevent and control diabetes but most devices for measuring glucose levels are invasive and not amenable for continuous monitoring. Here, we present an alternative method to overcome these shortcomings based on non-invasive optical photoplethysmography (PPG) for detecting diabetes. We classify non-Diabetic and Diabetic patients using the PPG signal and metadata for training Logistic Regression (LR) and eXtreme Gradient Boosting (XGBoost) algorithms. We used PPG signals from a publicly available dataset. To prevent overfitting, we divided the data into five folds for cross-validation. By ensuring that patients in the training set are not in the testing set, the model's performance can be evaluated on unseen subjects' data, providing a more accurate assessment of its generalization. Our model achieved an F1-Score and AUC of $58.8\pm20.0\%$ and $79.2\pm15.0\%$ for LR and $51.7\pm16.5\%$ and $73.6\pm17.0\%$ for XGBoost, respectively. Feature analysis suggested that PPG morphological features contains diabetes-related information alongside metadata. Our findings are within the same range reported in the literature, indicating that machine learning methods are promising for developing remote, non-invasive, and continuous measurement devices for detecting and preventing diabetes.
△ Less
Submitted 2 August, 2023;
originally announced August 2023.
-
Quality Assessment of Photoplethysmography Signals For Cardiovascular Biomarkers Monitoring Using Wearable Devices
Authors:
Felipe M. Dias,
Marcelo A. F. Toledo,
Diego A. C. Cardenas,
Douglas A. Almeida,
Filipe A. C. Oliveira,
Estela Ribeiro,
Jose E. Krieger,
Marco A. Gutierrez
Abstract:
Photoplethysmography (PPG) is a non-invasive technology that measures changes in blood volume in the microvascular bed of tissue. It is commonly used in medical devices such as pulse oximeters and wrist worn heart rate monitors to monitor cardiovascular hemodynamics. PPG allows for the assessment of parameters (e.g., heart rate, pulse waveform, and peripheral perfusion) that can indicate condition…
▽ More
Photoplethysmography (PPG) is a non-invasive technology that measures changes in blood volume in the microvascular bed of tissue. It is commonly used in medical devices such as pulse oximeters and wrist worn heart rate monitors to monitor cardiovascular hemodynamics. PPG allows for the assessment of parameters (e.g., heart rate, pulse waveform, and peripheral perfusion) that can indicate conditions such as vasoconstriction or vasodilation, and provides information about microvascular blood flow, making it a valuable tool for monitoring cardiovascular health. However, PPG is subject to a number of sources of variations that can impact its accuracy and reliability, especially when using a wearable device for continuous monitoring, such as motion artifacts, skin pigmentation, and vasomotion. In this study, we extracted 27 statistical features from the PPG signal for training machine-learning models based on gradient boosting (XGBoost and CatBoost) and Random Forest (RF) algorithms to assess quality of PPG signals that were labeled as good or poor quality. We used the PPG time series from a publicly available dataset and evaluated the algorithm s performance using Sensitivity (Se), Positive Predicted Value (PPV), and F1-score (F1) metrics. Our model achieved Se, PPV, and F1-score of 94.4, 95.6, and 95.0 for XGBoost, 94.7, 95.9, and 95.3 for CatBoost, and 93.7, 91.3 and 92.5 for RF, respectively. Our findings are comparable to state-of-the-art reported in the literature but using a much simpler model, indicating that ML models are promising for developing remote, non-invasive, and continuous measurement devices.
△ Less
Submitted 17 July, 2023;
originally announced July 2023.
-
Constraints on the structure and seasonal variations of Triton's atmosphere from the 5 October 2017 stellar occultation and previous observations
Authors:
J. Marques Oliveira,
B. Sicardy,
A. R. Gomes-Júnior,
J. L. Ortiz,
D. F. Strobel,
T. Bertrand,
F. Forget,
E. Lellouch,
J. Desmars,
D. Bérard,
A. Doressoundiram,
J. Lecacheux,
R. Leiva,
E. Meza,
F. Roques,
D. Souami,
T. Widemann,
P. Santos-Sanz,
N. Morales,
R. Duffard,
E. Fernández-Valenzuela,
A. J. Castro-Tirado,
F. Braga-Ribas,
B. E. Morgado,
M. Assafin
, et al. (212 additional authors not shown)
Abstract:
A stellar occultation by Neptune's main satellite, Triton, was observed on 5 October 2017 from Europe, North Africa, and the USA. We derived 90 light curves from this event, 42 of which yielded a central flash detection.
We aimed at constraining Triton's atmospheric structure and the seasonal variations of its atmospheric pressure since the Voyager 2 epoch (1989). We also derived the shape of th…
▽ More
A stellar occultation by Neptune's main satellite, Triton, was observed on 5 October 2017 from Europe, North Africa, and the USA. We derived 90 light curves from this event, 42 of which yielded a central flash detection.
We aimed at constraining Triton's atmospheric structure and the seasonal variations of its atmospheric pressure since the Voyager 2 epoch (1989). We also derived the shape of the lower atmosphere from central flash analysis. We used Abel inversions and direct ray-tracing code to provide the density, pressure, and temperature profiles in the altitude range $\sim$8 km to $\sim$190 km, corresponding to pressure levels from 9 μbar down to a few nanobars.
Results. (i) A pressure of 1.18$\pm$0.03 μbar is found at a reference radius of 1400 km (47 km altitude). (ii) A new analysis of the Voyager 2 radio science occultation shows that this is consistent with an extrapolation of pressure down to the surface pressure obtained in 1989. (iii) A survey of occultations obtained between 1989 and 2017 suggests that an enhancement in surface pressure as reported during the 1990s might be real, but debatable, due to very few high S/N light curves and data accessible for reanalysis. The volatile transport model analysed supports a moderate increase in surface pressure, with a maximum value around 2005-2015 no higher than 23 μbar. The pressures observed in 1995-1997 and 2017 appear mutually inconsistent with the volatile transport model presented here. (iv) The central flash structure does not show evidence of an atmospheric distortion. We find an upper limit of 0.0011 for the apparent oblateness of the atmosphere near the 8 km altitude.
△ Less
Submitted 25 January, 2022;
originally announced January 2022.
-
An extensive spectroscopic time series of three Wolf-Rayet stars -- II. A search for wind asymmetries in the dust-forming WC7 binary WR137
Authors:
N. St-Louis,
C. Piaulet,
N. D. Richardson,
T. Shenar,
A. F. J. Moffat,
T. Eversberg,
G. M. Hill,
B. Gauza,
J. H. Knapen,
J. Kubat,
B. Kubatova,
D. P. Sablowski,
S. Simon-Diaz,
F. Bolduan,
F. M. Dias,
P. Dubreuil,
D. Fuchs,
T. Garrel,
G. Grutzeck,
T. Hunger,
D. Kusters,
M. Langenbrink,
R. Leadbeater,
D. Li,
A. Lopez
, et al. (17 additional authors not shown)
Abstract:
We present the results of a four-month, spectroscopic campaign of the Wolf-Rayet dust-making binary, WR137. We detect only small-amplitude, random variability in the CIII5696 emission line and its integrated quantities (radial velocity, equivalent width, skewness, kurtosis) that can be explained by stochastic clumps in the wind of the WC star. We find no evidence of large-scale, periodic variation…
▽ More
We present the results of a four-month, spectroscopic campaign of the Wolf-Rayet dust-making binary, WR137. We detect only small-amplitude, random variability in the CIII5696 emission line and its integrated quantities (radial velocity, equivalent width, skewness, kurtosis) that can be explained by stochastic clumps in the wind of the WC star. We find no evidence of large-scale, periodic variations often associated with Corotating Interaction Regions that could have explained the observed intrinsic continuum polarization of this star. Our moderately high-resolution and high signal-to-noise average Keck spectrum shows narrow double-peak emission profiles in the Halpha, Hbeta, Hgamma, HeII6678 and HeII5876 lines. These peaks have a stable blue-to-red intensity ratio with a mean of 0.997 and a root-mean-square of 0.004, commensurate with the noise level; no variability is found during the entire observing period. We suggest that these profiles arise in a decretion disk around the O9 companion, which is thus an O9e star. The characteristics of the profiles are compatible with those of other Be/Oe stars. The presence of this disk can explain the constant component of the continuum polarization of this system, for which the angle is perpendicular to the plane of the orbit, implying that the rotation axis of the O9e star is aligned with that of the orbit. It remains to be explained why the disk is so stable within the strong ultraviolet radiation field of the O star. We present a binary evolutionary scenario that is compatible with the current stellar and system parameters.
△ Less
Submitted 17 July, 2020;
originally announced July 2020.
-
An extensive spectroscopic time-series of three Wolf-Rayet stars. I. The lifetime of large-scale structures in the wind of WR 134
Authors:
E. J. Aldoretta,
N. St-Louis,
N. D. Richardson,
A. F. J. Moffat,
T. Eversberg,
G. M. Hill,
T. Shenar,
É. Artigau,
B. Gauza,
J. H. Knapen,
J. Kubát,
B. Kubátová,
R. Maltais-Tariant,
M. Muñoz,
H. Pablo,
T. Ramiaramanantsoa,
A. Richard-Laferrière,
D. P. Sablowski,
S. Simón-Díaz,
L. St-Jean,
F. Bolduan,
F. M. Dias,
P. Dubreuil,
D. Fuchs,
T. Garrel
, et al. (24 additional authors not shown)
Abstract:
During the summer of 2013, a 4-month spectroscopic campaign took place to observe the variabilities in three Wolf-Rayet stars. The spectroscopic data have been analyzed for WR 134 (WN6b), to better understand its behaviour and long-term periodicity, which we interpret as arising from corotating interaction regions (CIRs) in the wind. By analyzing the variability of the He II $λ$5411 emission line,…
▽ More
During the summer of 2013, a 4-month spectroscopic campaign took place to observe the variabilities in three Wolf-Rayet stars. The spectroscopic data have been analyzed for WR 134 (WN6b), to better understand its behaviour and long-term periodicity, which we interpret as arising from corotating interaction regions (CIRs) in the wind. By analyzing the variability of the He II $λ$5411 emission line, the previously identified period was refined to P = 2.255 $\pm$ 0.008 (s.d.) days. The coherency time of the variability, which we associate with the lifetime of the CIRs in the wind, was deduced to be 40 $\pm$ 6 days, or $\sim$ 18 cycles, by cross-correlating the variability patterns as a function of time. When comparing the phased observational grayscale difference images with theoretical grayscales previously calculated from models including CIRs in an optically thin stellar wind, we find that two CIRs were likely present. A separation in longitude of $Δφ\simeq$ 90$^{\circ}$ was determined between the two CIRs and we suggest that the different maximum velocities that they reach indicate that they emerge from different latitudes. We have also been able to detect observational signatures of the CIRs in other spectral lines (C IV $λλ$5802,5812 and He I $λ$5876). Furthermore, a DAC was found to be present simultaneously with the CIR signatures detected in the He I $λ$5876 emission line which is consistent with the proposed geometry of the large-scale structures in the wind. Small-scale structures also show a presence in the wind, simultaneously with the larger scale structures, showing that they do in fact co-exist.
△ Less
Submitted 16 May, 2016;
originally announced May 2016.
-
Spectroscopic variability of two Oe stars
Authors:
G. Rauw,
T. Morel,
Y. Naze,
T. Eversberg,
F. Alves,
W. Arnold,
T. Bergmann,
N. G. Correia Viegas,
R. Fahed,
A. Fernando,
J. N. Gonzalez-Perez,
L. F. Gouveia Carreira,
A. Hempelmann,
T. Hunger,
J. H. Knapen,
R. Leadbeater,
F. Marques Dias,
M. Mittag,
A. F. J. Moffat,
N. Reinecke,
J. Ribeiro,
N. Romeo,
J. Sanchez Gallego,
E. M. Dos Santos,
L. Schanne
, et al. (6 additional authors not shown)
Abstract:
The Oe stars HD45314 and HD60848 have recently been found to exhibit very different X-ray properties: whilst HD60848 has an X-ray spectrum and emission level typical of most OB stars, HD45314 features a much harder and brighter X-ray emission, making it a so-called gamma Cas analogue. Monitoring the optical spectra could provide hints towards the origin of these very different behaviours. We analy…
▽ More
The Oe stars HD45314 and HD60848 have recently been found to exhibit very different X-ray properties: whilst HD60848 has an X-ray spectrum and emission level typical of most OB stars, HD45314 features a much harder and brighter X-ray emission, making it a so-called gamma Cas analogue. Monitoring the optical spectra could provide hints towards the origin of these very different behaviours. We analyse a large set of spectroscopic observations of HD45314 and HD60848, extending over 20 years. We further attempt to fit the H-alpha line profiles of both stars with a simple model of emission line formation in a Keplerian disk. Strong variations in the strengths of the H-alpha, H-beta, and He I 5876 emission lines are observed for both stars. In the case of HD60848, we find a time lag between the variations in the equivalent widths of these lines. The emission lines are double peaked with nearly identical strengths of the violet and red peaks. The H-alpha profile of this star can be successfully reproduced by our model of a disk seen under an inclination of 30 degrees. In the case of HD45314, the emission lines are highly asymmetric and display strong line profile variations. We find a major change in behaviour between the 2002 outburst and the one observed in 2013. This concerns both the relationship between the equivalent widths of the various lines and their morphologies at maximum strength (double-peaked in 2002 versus single-peaked in 2013). Our simple disk model fails to reproduce the observed H-alpha line profiles of HD45314. Our results further support the interpretation that Oe stars do have decretion disks similar to those of Be stars. Whilst the emission lines of HD60848 are explained by a disk with a Keplerian velocity field, the disk of HD45314 seems to have a significantly more complex velocity field that could be related to the phenomenon that produces its peculiar X-ray emission.
△ Less
Submitted 7 January, 2015;
originally announced January 2015.
-
The WR 140 periastron passage 2009: first results from MONS and other optical sources
Authors:
R. Fahed,
A. F. J. Moffat,
J. Zorec,
T. Eversberg,
A. N. Chené,
F. Alves,
W. Arnold,
T. Bergmann,
L. F. Gouveia Carreira,
F. Marques Dias,
A. Fernando,
J. Sanchez Gallego,
T. Hunger,
J. H. Knapen,
R. Leadbeater,
T. Morel,
G. Rauw,
N. Reinecke,
J. Ribeiro,
N. Romeo,
E. M. dos Santos,
L. Schanne,
O. Stahl,
Ba. Stober,
Be. Stober
, et al. (7 additional authors not shown)
Abstract:
We present the results from the spectroscopic follow-up of WR140 (WC7 + O4-5) during its last periastron passage in January 2009. This object is known as the archetype of colliding wind binaries and has a relatively large period (~ 8 years) and eccentricity (~ 0.89). We provide updated values for the orbital parameters, new estimates for the WR and O star masses and new constraints on the mass-los…
▽ More
We present the results from the spectroscopic follow-up of WR140 (WC7 + O4-5) during its last periastron passage in January 2009. This object is known as the archetype of colliding wind binaries and has a relatively large period (~ 8 years) and eccentricity (~ 0.89). We provide updated values for the orbital parameters, new estimates for the WR and O star masses and new constraints on the mass-loss rates.
△ Less
Submitted 7 January, 2011;
originally announced January 2011.
-
Variability monitoring of OB stars during the Mons campaign
Authors:
T. Morel,
G. Rauw,
T. Eversberg,
F. Alves,
W. Arnold,
T. Bergmann,
N. G. Correia Viegas,
R. Fahed,
A. Fernando,
L. F. Gouveia Carreira,
T. Hunger,
J. H. Knapen,
R. Leadbeater,
F. Marques Dias,
A. F. J. Moffat,
N. Reinecke,
J. Ribeiro,
N. Romeo,
J. Sanchez Gallego,
E. M. dos Santos,
L. Schanne,
O. Stahl,
Ba. Stober,
Be. Stober,
K. Vollmann
, et al. (6 additional authors not shown)
Abstract:
We present preliminary results of a 3-month campaign carried out in the framework of the Mons project, where time-resolved Halpha observations are used to study the wind and circumstellar properties of a number of OB stars.
We present preliminary results of a 3-month campaign carried out in the framework of the Mons project, where time-resolved Halpha observations are used to study the wind and circumstellar properties of a number of OB stars.
△ Less
Submitted 23 September, 2010;
originally announced September 2010.