-
SEAtech: Deception Techniques in Social Engineering Attacks: An Analysis of Emerging Trends and Countermeasures
Authors:
Devendra Chapagain,
Naresh Kshetri,
Bindu Aryal,
Bhawani Dhakal
Abstract:
Social Engineering is the act of manipulating individuals to perform actions or reveal information. Social engineering tactics are widely recognized as a significant risk to information security. The increasing digital environment has increased the prevalence of social engineering attacks, bringing huge threats to both people and organizations. This paper explores current deception techniques used…
▽ More
Social Engineering is the act of manipulating individuals to perform actions or reveal information. Social engineering tactics are widely recognized as a significant risk to information security. The increasing digital environment has increased the prevalence of social engineering attacks, bringing huge threats to both people and organizations. This paper explores current deception techniques used during social engineering attacks to understand emerging trends and discuss effective countermeasures. It is always a good idea to have knowledge of counter measures and risks from these increasing cyber threats. We have also explored the types of deception attacks and role of social engineering in Advanced Persistent Threats. Today major concern for cybersecurity and other web related attacks is due to social engineering attacks that is also the driving force of increasing cybercrimes worldwide. By uncovering emerging trends and analyzing the psychological underpinnings of these attacks this paper highlights the known deception techniques, emerging trends and counter measures of social engineering attacks.
△ Less
Submitted 4 August, 2024;
originally announced August 2024.
-
A Cryogenic Tune and Match Circuit for Magnetic Resonance Microscopy at 15.2T
Authors:
Benjamin M. Hardy,
Gary Drake,
Shuyang Chai,
Bibek Dhakal,
Jonathan B. Martin,
Junzhong Xu,
Mark D. Does,
Adam W. Anderson,
Xinqiang Yan,
John C. Gore
Abstract:
Signal to noise ratios (SNR) in magnetic resonance microscopy images are limited by acquisition times and the decreasing number of spins in smaller voxels. Significant SNR gains from cooling of the RF receiver are only realized when the Johnson noise generated within the RF hardware is large compared to the electromagnetic noise produced by the sample. Cryogenic cooling of imaging probes is common…
▽ More
Signal to noise ratios (SNR) in magnetic resonance microscopy images are limited by acquisition times and the decreasing number of spins in smaller voxels. Significant SNR gains from cooling of the RF receiver are only realized when the Johnson noise generated within the RF hardware is large compared to the electromagnetic noise produced by the sample. Cryogenic cooling of imaging probes is common in high field systems but proves difficult to insulate the sample from extreme temperatures. We designed a chamber to cool only the tune and match circuitry to show it is possible to achieve much of the available SNR gain available for cooled coils. We designed a microcoil circuit to resonate at 650 MHz for imaging on a 15.2 T scanner. Surface loops and solenoids of varying diameters were tested to determine the largest diameter coil that demonstrated significant SNR gains from cooling. A liquid N2 cryochamber was designed to cool the circuitry while leaving the RF coil in ambient air. As the cryochamber was filled with liquid N2, Q-factors were measured on the bench while monitoring the coil's surface temperature. Improvements of SNR on images of solutions were demonstrated via cooling the tune and match circuit in the magnet bore. At 650 MHz, loops and solenoids < 3 mm in diameter showed significant improvements in quality factor on the bench. The resistance of the variable capacitors and the coaxial cable were measured to be 45% and 32% of room temperature values near the Larmor frequency. Images obtained with a 2 turn, 3 mm diameter loop with the matching circuit at room temperature and then cooled with liquid nitrogen demonstrated SNR improvements of a factor of 2. By cooling the tune and match circuit and leaving the surface loop in ambient air, SNR was improved by a factor of 2. The results are significant because it allows for more space to insulate the sample from extreme temperatures.
△ Less
Submitted 24 August, 2023;
originally announced August 2023.
-
Experimental demonstration of diffusion limitations on resolution and SNR in MR microscopy
Authors:
Benjamin M. Hardy,
Yue Zhu,
Kevin D. Harkins,
Bibek Dhakal,
Jonathan B. Martin,
Jingping Xie,
Junzhong Xu,
Mark D. Does,
Adam W. Anderson,
John C. Gore
Abstract:
Magnetic resonance microscopy images at cellular resolution (< 10 microns) are limited by diffusion. SNR and spatial resolution suffer from the dephasing of transverse magnetization caused by diffusion of spins in strong gradients. Such effects may be reduced by using phase encoding instead of frequency encoding readout gradients. Demonstration of the benefits of phase encoding are lacking, and th…
▽ More
Magnetic resonance microscopy images at cellular resolution (< 10 microns) are limited by diffusion. SNR and spatial resolution suffer from the dephasing of transverse magnetization caused by diffusion of spins in strong gradients. Such effects may be reduced by using phase encoding instead of frequency encoding readout gradients. Demonstration of the benefits of phase encoding are lacking, and the conditions in which it is preferred are not clearly established. We quantify when phase encoding outperforms a readout gradient with emphasis on the detrimental effects of diffusion on SNR and resolution. A 15.2T MRI scanner, with 1 T/m gradients, and micro solenoid RF coils < 1 mm in diameter, were used to quantify diffusion effects on resolution and SNR of frequency and phase encoded acquisitions. Frequency and phase encoding resolution and SNR per square root time were calculated and measured for images at the diffusion limited resolution. The point-spread-function was measured for phase and frequency encoding using additional constant time gradients with voxels 3-15 microns. The effect of diffusion during the readout gradient on SNR was experimentally demonstrated. The achieved resolutions of frequency and phase encoded acquisitions were measured via the point-spread-function. SNR per square root time and actual resolution were calculated for a wide range of gradient amplitudes, diffusion coefficients, and relaxation properties. The results provide a practical guide on how to choose between phase and frequency encoding. Images of excised rat spinal cord at 10 x 10 microns in-plane demonstrate benefits of phase encoding in the form of higher measured resolution and SNR vs the same image acquired with a conventional readout. We demonstrate the extent to which phase encoding outperforms readout gradients in SNR and resolution over a wide range of voxel sizes, sample, and hardware properties.
△ Less
Submitted 3 January, 2023; v1 submitted 2 January, 2023;
originally announced January 2023.