A Comparison of Proton Stopping Power Measured with Proton CT and x-ray CT in Fresh Post-Mortem Porcine Structures
Authors:
Don F. DeJongh,
Ethan A. DeJongh,
Victor Rykalin,
Greg DeFillippo,
Mark Pankuch,
Andrew W. Best,
George Coutrakon,
Kirk L. Duffin,
Nicholas T. Karonis,
Caesar E. Ordoñez,
Christina Sarosiek,
Reinhard W. Schulte,
John R. Winans,
Alec M. Block,
Courtney L. Hentz,
James S. Welsh
Abstract:
Purpose: Currently, calculations of proton range in proton therapy patients are based on a conversion of CT Hounsfield Units of patient tissues into proton relative stopping power. Uncertainties in this conversion necessitate larger proximal and distal planned target volume margins. Proton CT can potentially reduce these uncertainties by directly measuring proton stopping power. We aim to demonstr…
▽ More
Purpose: Currently, calculations of proton range in proton therapy patients are based on a conversion of CT Hounsfield Units of patient tissues into proton relative stopping power. Uncertainties in this conversion necessitate larger proximal and distal planned target volume margins. Proton CT can potentially reduce these uncertainties by directly measuring proton stopping power. We aim to demonstrate proton CT imaging with complex porcine samples, to analyze in detail three-dimensional regions of interest, and to compare proton stopping powers directly measured by proton CT to those determined from x-ray CT scans.
Methods: We have used a prototype proton imaging system with single proton tracking to acquire proton radiography and proton CT images of a sample of porcine pectoral girdle and ribs, and a pig's head. We also acquired close in time x-ray CT scans of the same samples, and compared proton stopping power measurements from the two modalities. In the case of the pig's head, we obtained x-ray CT scans from two different scanners, and compared results from high-dose and low-dose settings.
Results: Comparing our reconstructed proton CT images with images derived from x-ray CT scans, we find agreement within 1% to 2% for soft tissues, and discrepancies of up to 6% for compact bone. We also observed large discrepancies, up to 40%, for cavitated regions with mixed content of air, soft tissue, and bone, such as sinus cavities or tympanic bullae.
Conclusions: Our images and findings from a clinically realistic proton CT scanner demonstrate the potential for proton CT to be used for low-dose treatment planning with reduced margins.
△ Less
Submitted 29 October, 2021; v1 submitted 11 December, 2020;
originally announced December 2020.
-
Analysis of characteristics of images acquired with a prototype clinical proton radiography system
Authors:
Christina Sarosiek,
Ethan A. DeJongh,
George Coutrakon,
Don F. DeJongh,
Kirk L. Duffin,
Nicholas T. Karonis,
Caesar E. Ordoñez,
Mark Pankuch,
Victor Rykalin,
John R. Winans,
James S. Welsh
Abstract:
Verification of patient specific proton stopping powers obtained in the patient treatment position can be used to reduce the distal margins needed in particle beam planning. Proton radiography can be used as a pre-treatment instrument to verify integrated stopping power consistency with the treatment planning CT. Although a proton radiograph is a pixel by pixel representation of integrated stoppin…
▽ More
Verification of patient specific proton stopping powers obtained in the patient treatment position can be used to reduce the distal margins needed in particle beam planning. Proton radiography can be used as a pre-treatment instrument to verify integrated stopping power consistency with the treatment planning CT. Although a proton radiograph is a pixel by pixel representation of integrated stopping powers, the image may also be of high enough quality and contrast to be used for patient alignment. This investigation qualifies the accuracy and image quality of a prototype proton radiography system on a clinical proton delivery system. We have developed a clinical prototype proton radiography system designed for integration into efficient clinical workflows. We tested the images obtained by this system for water-equivalent thickness (WET) accuracy, image noise, and spatial resolution. We evaluated the WET accuracy by comparing the average WET and rms error in several regions of interest (ROI) on a proton radiograph of a custom peg phantom. We measured the spatial resolution on a CATPHAN Line Pair phantom and a custom edge phantom by measuring the 10% value of the modulation transfer function (MTF). In addition, we tested the ability to detect proton range errors due to anatomical changes in a patient with a customized CIRS pediatric head phantom and inserts of varying WET placed in the posterior fossae of the brain. We took proton radiographs of the phantom with each insert in place and created difference maps between the resulting images. Integrated proton range was measured from an ROI in the difference maps.
△ Less
Submitted 24 February, 2021; v1 submitted 9 September, 2020;
originally announced September 2020.
-
Technical Note: A fast and monolithic prototype clinical proton radiography system optimized for pencil beam scanning
Authors:
Ethan A. DeJongh,
Don F. DeJongh,
Igor Polnyi,
Victor Rykalin,
Christina Sarosiek,
George Coutrakon,
Kirk L. Duffin,
Nicholas T. Karonis,
Caesar E. Ordoñez,
Mark Pankuch,
John R. Winans,
James S. Welsh
Abstract:
Purpose: To demonstrate a proton imaging system based on well-established fast scintillator technology to achieve high performance with low cost and complexity, with the potential of a straightforward translation into clinical use. Methods: The system tracks individual protons through one (X, Y) scintillating fiber tracker plane upstream and downstream of the object and into a 13 cm-thick scintill…
▽ More
Purpose: To demonstrate a proton imaging system based on well-established fast scintillator technology to achieve high performance with low cost and complexity, with the potential of a straightforward translation into clinical use. Methods: The system tracks individual protons through one (X, Y) scintillating fiber tracker plane upstream and downstream of the object and into a 13 cm-thick scintillating block residual energy detector. The fibers in the tracker planes are multiplexed into silicon photomultipliers (SiPMs) to reduce the number of electronics channels. The light signal from the residual energy detector is collected by 16 photomultiplier tubes (PMTs). Only four signals from the PMTs are output from each event, which allows for fast signal readout. A robust calibration method of the PMT signal to residual energy has been developed to obtain accurate proton images. The development of patient-specific scan patterns using multiple input energies allows for an image to be produced with minimal excess dose delivered to the patient. Results: The calibration of signals in the energy detector produces accurate residual range measurements limited by intrinsic range straggling. We measured the water-equivalent thickness (WET) of a block of solid water (physical thickness of 6.10 mm) with a proton radiograph. The mean WET from all pixels in the block was 6.13 cm (SD 0.02 cm). The use of patient-specific scan patterns using multiple input energies enables imaging with a compact range detector. Conclusions: We have developed a prototype clinical proton radiography system for pretreatment imaging in proton radiation therapy. We have optimized the system for use with pencil beam scanning systems and have achieved a reduction of size and complexity compared to previous designs.
△ Less
Submitted 5 January, 2021; v1 submitted 9 September, 2020;
originally announced September 2020.
-
A Real-time Image Reconstruction System for Particle Treatment Planning Using Proton Computed Tomography (pCT)
Authors:
Caesar E. Ordoñez,
Nicholas Karonis,
Kirk Duffin,
George Coutrakon,
Reinhard Schulte,
Robert Johnson,
Mark Pankuch
Abstract:
Proton computed tomography (pCT) is a novel medical imaging modality for mapping the distribution of proton relative stopping power (RSP) in medical objects of interest. Compared to conventional X-ray computed tomography, where range uncertainty margins are around 3.5%, pCT has the potential to provide more accurate measurements to within 1%. This improved efficiency will be beneficial to proton-t…
▽ More
Proton computed tomography (pCT) is a novel medical imaging modality for mapping the distribution of proton relative stopping power (RSP) in medical objects of interest. Compared to conventional X-ray computed tomography, where range uncertainty margins are around 3.5%, pCT has the potential to provide more accurate measurements to within 1%. This improved efficiency will be beneficial to proton-therapy planning and pre-treatment verification. A prototype pCT imaging device has recently been developed capable of rapidly acquiring low-dose proton radiographs of head-sized objects. We have also developed an advanced, fast image reconstruction software based on distributed computing that utilizes parallel processors and graphical processing units. The combination of fast data acquisition and fast image reconstruction will enable the availability of RSP images within minutes for use in clinical settings. The performance of our image reconstruction software has been evaluated using data collected by the prototype pCT scanner from several phantoms.
△ Less
Submitted 17 July, 2017;
originally announced July 2017.
-
Results from a Prototype Proton-CT Head Scanner
Authors:
R. P. Johnson,
V. A. Bashkirov,
G. Coutrakon,
V. Giacometti,
P. Karbasi,
N. T. Karonis,
C. E. Ordoñez,
M. Pankuch,
H. F. -W. Sadrozinski,
K. E. Schubert,
R. W. Schulte
Abstract:
We are exploring low-dose proton radiography and computed tomography (pCT) as techniques to improve the accuracy of proton treatment planning and to provide artifact-free images for verification and adaptive therapy at the time of treatment. Here we report on comprehensive beam test results with our prototype pCT head scanner. The detector system and data acquisition attain a sustained rate of mor…
▽ More
We are exploring low-dose proton radiography and computed tomography (pCT) as techniques to improve the accuracy of proton treatment planning and to provide artifact-free images for verification and adaptive therapy at the time of treatment. Here we report on comprehensive beam test results with our prototype pCT head scanner. The detector system and data acquisition attain a sustained rate of more than a million protons individually measured per second, allowing a full CT scan to be completed in six minutes or less of beam time. In order to assess the performance of the scanner for proton radiography as well as computed tomography, we have performed numerous scans of phantoms at the Northwestern Medicine Chicago Proton Center including a custom phantom designed to assess the spatial resolution, a phantom to assess the measurement of relative stopping power, and a dosimetry phantom. Some images, performance, and dosimetry results from those phantom scans are presented together with a description of the instrument, the data acquisition system, and the calibration methods.
△ Less
Submitted 5 July, 2017;
originally announced July 2017.
-
Calibration and GEANT4 Simulations of the Phase II Proton Compute Tomography (pCT) Range Stack Detector
Authors:
S. A. Uzunyan,
G. Blazey,
S. Boi,
G. Coutrakon,
A. Dyshkant,
K. Francis,
D. Hedin,
E. Johnson,
J. Kalnins,
V. Zutshi,
R. Ford,
J. E. Rauch,
P. Rubinov,
G. Sellberg,
P. Wilson,
M. Naimuddin
Abstract:
Northern Illinois University in collaboration with Fermi National Accelerator Laboratory (FNAL) and Delhi University has been designing and building a proton CT scanner for applications in proton treatment planning. The Phase II proton CT scanner consists of eight planes of tracking detectors with two X and two Y coordinate measurements both before and after the patient. In addition, a range stack…
▽ More
Northern Illinois University in collaboration with Fermi National Accelerator Laboratory (FNAL) and Delhi University has been designing and building a proton CT scanner for applications in proton treatment planning. The Phase II proton CT scanner consists of eight planes of tracking detectors with two X and two Y coordinate measurements both before and after the patient. In addition, a range stack detector consisting of a stack of thin scintillator tiles, arranged in twelve eight-tile frames, is used to determine the water equivalent path length (WEPL) of each track through the patient. The X-Y coordinates and WEPL are required input for image reconstruction software to find the relative (proton) stopping powers (RSP) value of each voxel in the patient and generate a corresponding 3D image. In this Note we describe tests conducted in 2015 at the proton beam at the Central DuPage Hospital in Warrenville, IL, focusing on the range stack calibration procedure and comparisons with the GEANT~4 range stack simulation.
△ Less
Submitted 4 January, 2016; v1 submitted 3 January, 2016;
originally announced January 2016.
-
Development of a proton Computed Tomography Detector System
Authors:
Md. Naimuddin,
G. Coutrakon,
G. Blazey,
S. Boi,
A. Dyshkant,
B. Erdelyi,
D. Hedin,
E. Johnson,
J. Krider,
V. Rukalin,
S. A. Uzunyan,
V. Zutshi,
R. Fordt,
G. Sellberg,
J. E. Rauch,
M. Roman,
P. Rubinov,
P. Wilson
Abstract:
Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantageous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with…
▽ More
Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantageous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.
△ Less
Submitted 1 October, 2015;
originally announced October 2015.
-
A New Proton CT Scanner
Authors:
S. A. Uzunyan,
G. Blazey,
S. Boi,
G. Coutrakon,
A. Dyshkant,
B. Erdelyi,
D. Hedin,
E. Johnson,
J. Krider,
V. Rykalin,
V. Zutshi,
R. Ford,
G. Sellberg,
J . E. Rauch,
M. Roman,
P. Rubinov,
P. Wilson,
M. Naimuddin
Abstract:
The design, construction, and preliminary testing of a second generation proton CT scanner is presented. All current treatment planning systems at proton therapy centers use X-ray CT as the primary imaging modality for treatment planning to calculate doses to tumor and healthy tissues. One of the limitations of X-ray CT is in the conversion of X-ray attenuation coefficients to relative (proton) st…
▽ More
The design, construction, and preliminary testing of a second generation proton CT scanner is presented. All current treatment planning systems at proton therapy centers use X-ray CT as the primary imaging modality for treatment planning to calculate doses to tumor and healthy tissues. One of the limitations of X-ray CT is in the conversion of X-ray attenuation coefficients to relative (proton) stopping powers, or RSP. This results in more proton range uncertainty, larger target volumes and therefore, more dose to healthy tissues. To help improve this, we present a novel scanner capable of high dose rates, up to 2~MHz, and large area coverage, 20~x~24~cm$^2$, for imaging an adult head phantom and reconstructing more accurate RSP values.
△ Less
Submitted 4 January, 2016; v1 submitted 29 August, 2014;
originally announced September 2014.
-
Development of a proton Computed Tomography (pCT) scanner at NIU
Authors:
S. A. Uzunyan,
G. Blazey,
S. Boi,
G. Coutrakon,
A. Dyshkant,
B. Erdelyi,
A. Gearhart,
D. Hedin,
E. Johnson,
J. Krider,
V. Zutshi,
R. Ford,
T. Fitzpatrick,
G. Sellberg,
J. E. Rauch,
M. Roman,
P. Rubinov,
P. Wilson,
K. Lalwani,
M. Naimuddin
Abstract:
We describe the development of a proton Computed Tomography (pCT) scanner at Northern Illinois University (NIU) in collaboration with Fermilab and Delhi University. This paper provides an overview of major components of the scanner and a detailed description of the data acquisition system (DAQ).
We describe the development of a proton Computed Tomography (pCT) scanner at Northern Illinois University (NIU) in collaboration with Fermilab and Delhi University. This paper provides an overview of major components of the scanner and a detailed description of the data acquisition system (DAQ).
△ Less
Submitted 13 December, 2013;
originally announced December 2013.