WALINET: A water and lipid identification convolutional Neural Network for nuisance signal removal in 1H MR Spectroscopic Imaging
Authors:
Paul Weiser,
Georg Langs,
Stanislav Motyka,
Wolfgang Bogner,
Sébastien Courvoisier,
Malte Hoffmann,
Antoine Klauser,
Ovidiu C. Andronesi
Abstract:
Purpose. Proton Magnetic Resonance Spectroscopic Imaging (1H-MRSI) provides non-invasive spectral-spatial mapping of metabolism. However, long-standing problems in whole-brain 1H-MRSI are spectral overlap of metabolite peaks with large lipid signal from scalp, and overwhelming water signal that distorts spectra. Fast and effective methods are needed for high-resolution 1H-MRSI to accurately remove…
▽ More
Purpose. Proton Magnetic Resonance Spectroscopic Imaging (1H-MRSI) provides non-invasive spectral-spatial mapping of metabolism. However, long-standing problems in whole-brain 1H-MRSI are spectral overlap of metabolite peaks with large lipid signal from scalp, and overwhelming water signal that distorts spectra. Fast and effective methods are needed for high-resolution 1H-MRSI to accurately remove lipid and water signals while preserving the metabolite signal. The potential of supervised neural networks for this task remains unexplored, despite their success for other MRSI processing.
Methods. We introduce a deep-learning method based on a modified Y-NET network for water and lipid removal in whole-brain 1H-MRSI. The WALINET (WAter and LIpid neural NETwork) was compared to conventional methods such as the state-of-the-art lipid L2 regularization and Hankel-Lanczos singular value decomposition (HLSVD) water suppression. Methods were evaluated on simulated and in-vivo whole-brain MRSI using NMRSE, SNR, CRLB, and FWHM metrics.
Results. WALINET is significantly faster and needs 8s for high-resolution whole-brain MRSI, compared to 42 minutes for conventional HLSVD+L2. Quantitative analysis shows WALINET has better performance than HLSVD+L2: 1) more lipid removal with 41% lower NRMSE, 2) better metabolite signal preservation with 71% lower NRMSE in simulated data, 155% higher SNR and 50% lower CRLB in in-vivo data. Metabolic maps obtained by WALINET in healthy subjects and patients show better gray/white-matter contrast with more visible structural details.
Conclusions. WALINET has superior performance for nuisance signal removal and metabolite quantification on whole-brain 1H-MRSI compared to conventional state-of-the-art techniques. This represents a new application of deep-learning for MRSI processing, with potential for automated high-throughput workflow.
△ Less
Submitted 1 October, 2024;
originally announced October 2024.
-
SISMIK for brain MRI: Deep-learning-based motion estimation and model-based motion correction in k-space
Authors:
Oscar Dabrowski,
Jean-Luc Falcone,
Antoine Klauser,
Julien Songeon,
Michel Kocher,
Bastien Chopard,
François Lazeyras,
Sébastien Courvoisier
Abstract:
MRI, a widespread non-invasive medical imaging modality, is highly sensitive to patient motion. Despite many attempts over the years, motion correction remains a difficult problem and there is no general method applicable to all situations. We propose a retrospective method for motion estimation and correction to tackle the problem of in-plane rigid-body motion, apt for classical 2D Spin-Echo scan…
▽ More
MRI, a widespread non-invasive medical imaging modality, is highly sensitive to patient motion. Despite many attempts over the years, motion correction remains a difficult problem and there is no general method applicable to all situations. We propose a retrospective method for motion estimation and correction to tackle the problem of in-plane rigid-body motion, apt for classical 2D Spin-Echo scans of the brain, which are regularly used in clinical practice. Due to the sequential acquisition of k-space, motion artifacts are well localized. The method leverages the power of deep neural networks to estimate motion parameters in k-space and uses a model-based approach to restore degraded images to avoid ''hallucinations''. Notable advantages are its ability to estimate motion occurring in high spatial frequencies without the need of a motion-free reference. The proposed method operates on the whole k-space dynamic range and is moderately affected by the lower SNR of higher harmonics. As a proof of concept, we provide models trained using supervised learning on 600k motion simulations based on motion-free scans of 43 different subjects. Generalization performance was tested with simulations as well as in-vivo. Qualitative and quantitative evaluations are presented for motion parameter estimations and image reconstruction. Experimental results show that our approach is able to obtain good generalization performance on simulated data and in-vivo acquisitions. We provide a Python implementation at https://gitlab.unige.ch/Oscar.Dabrowski/sismik_mri/.
△ Less
Submitted 3 November, 2024; v1 submitted 20 December, 2023;
originally announced December 2023.
-
ECCENTRIC: a fast and unrestrained approach for high-resolution in vivo metabolic imaging at ultra-high field MR
Authors:
Antoine Klauser,
Bernhard Strasser,
Wolfgang Bogner,
Lukas Hingerl,
Sebastien Courvoisier,
Claudiu Schirda,
Francois Lazeyras,
Ovidiu C. Andronesi
Abstract:
A novel method for fast and high-resolution metabolic imaging, called ECcentric Circle ENcoding TRajectorIes for Compressed sensing (ECCENTRIC), has been developed and implemented at 7 Tesla MRI. ECCENTRIC is a non-Cartesian spatial-spectral encoding method optimized to accelerate magnetic resonance spectroscopic imaging (MRSI) with high signal-to-noise at ultra-high field. The approach provides f…
▽ More
A novel method for fast and high-resolution metabolic imaging, called ECcentric Circle ENcoding TRajectorIes for Compressed sensing (ECCENTRIC), has been developed and implemented at 7 Tesla MRI. ECCENTRIC is a non-Cartesian spatial-spectral encoding method optimized to accelerate magnetic resonance spectroscopic imaging (MRSI) with high signal-to-noise at ultra-high field. The approach provides flexible and random ($k,t$) sampling without temporal interleaving to improve spatial response function and spectral quality. ECCENTRIC needs low gradient amplitudes and slew-rates that reduces electrical, mechanical and thermal stress of the scanner hardware, and is robust to timing imperfection and eddy-current delays. Combined with a model-based low-rank reconstruction, this approach enables simultaneous imaging of up to 14 metabolites over the whole-brain at 2-3mm isotropic resolution in 4-10 minutes. In healthy volunteers ECCENTRIC demonstrated unprecedented spatial mapping of fine structural details of human brain neurochemistry. This innovative tool introduces a novel approach to neuroscience, providing new insights into the exploration of brain activity and physiology.
△ Less
Submitted 21 December, 2023; v1 submitted 23 May, 2023;
originally announced May 2023.
-
Dynamical analysis in a self-regulated system undergoing multiple excitations: first order differential equation approach
Authors:
Denis Mongin,
Adriana Uribe,
Julien Gateau,
Baris Gencer,
Boris Cheval,
Stéphane Cullati,
Delphine S. Courvoisier
Abstract:
This article proposes a dynamical system modeling approach for the analysis of longitudinal data of self-regulated systems experiencing multiple excitations. The aim of such an approach is to focus on the evolution of a signal (e.g., heart rate) before, during, and after excitations taking the system out of its equilibrium (e.g., physical effort during cardiac stress testing). Dynamical modeling c…
▽ More
This article proposes a dynamical system modeling approach for the analysis of longitudinal data of self-regulated systems experiencing multiple excitations. The aim of such an approach is to focus on the evolution of a signal (e.g., heart rate) before, during, and after excitations taking the system out of its equilibrium (e.g., physical effort during cardiac stress testing). Dynamical modeling can be applied to a broad range of outcomes such as physiological processes in medicine and psychosocial processes in social sciences, and it allows to extract simple characteristics of the signal studied. The model we propose is based on a first order linear differential equation defined by three main parameters corresponding to the initial equilibrium value, the dynamic characteristic time, and the reaction to the excitation. In this paper, several estimation procedures for this model are considered and tested in a simulation study, that clarifies under which conditions accurate estimates are provided. Finally, applications of this model are illustrated using cardiology data recorded during effort tests.
△ Less
Submitted 1 March, 2020; v1 submitted 21 December, 2018;
originally announced January 2019.
-
Simultaneous Multi-Harmonic Imaging of Nanoparticles in Tissues for Increased Selectivity
Authors:
Andrii Rogov,
Marie Irondelle,
Fernanda Ramos-Gomes,
Julia Bode,
Davide Staedler,
Solène Passemard,
Sébastien Courvoisier,
Yasuaki Yamamoto,
François Waharte,
Daniel Ciepielewski,
Philippe Rideau,
Sandrine Gerber-Lemaire,
Frauke Alves,
Jean Salamero,
Luigi Bonacina,
Jean-Pierre Wolf
Abstract:
We investigate the use of Bismuth Ferrite (BFO) nanoparticles for tumor tissue labelling in combination with infrared multi-photon excitation at 1250 nm. We report the efficient and simultaneous generation of second and third harmonic by the nanoparticles. On this basis, we set up a novel imaging protocol based on the co-localization of the two harmonic signals and demonstrate its benefits in term…
▽ More
We investigate the use of Bismuth Ferrite (BFO) nanoparticles for tumor tissue labelling in combination with infrared multi-photon excitation at 1250 nm. We report the efficient and simultaneous generation of second and third harmonic by the nanoparticles. On this basis, we set up a novel imaging protocol based on the co-localization of the two harmonic signals and demonstrate its benefits in terms of increased selectivity against endogenous background sources in tissue samples. Finally, we discuss the use of BFO nanoparticles as mapping reference structures for correlative light-electron microscopy.
△ Less
Submitted 3 October, 2015; v1 submitted 29 October, 2014;
originally announced October 2014.