-
Multi-Grid Detector for Neutron Spectroscopy: Results Obtained on Time-of-Flight Spectrometer CNCS
Authors:
M. Anastasopoulos,
R. Bebb,
K. Berry,
J. Birch,
T. Bryś,
J. -C. Buffet,
J. -F. Clergeau,
P. P. Deen,
G. Ehlers,
P. van Esch,
S. M. Everett,
B. Guerard,
R. Hall-Wilton,
K. Herwig,
L. Hultman,
C. Höglund,
I. Iruretagoiena,
F. Issa,
J. Jensen,
A. Khaplanov,
O. Kirstein,
I. Lopez-Higuera,
F. Piscitelli,
L. Robinson,
S. Schmidt
, et al. (1 additional authors not shown)
Abstract:
The Multi-Grid detector technology has evolved from the proof-of-principle and characterisation stages. Here we report on the performance of the Multi-Grid detector, the MG.CNCS prototype, which has been installed and tested at the Cold Neutron Chopper Spectrometer, CNCS at SNS. This has allowed a side-by-side comparison to the performance of $^3$He detectors on an operational instrument. The demo…
▽ More
The Multi-Grid detector technology has evolved from the proof-of-principle and characterisation stages. Here we report on the performance of the Multi-Grid detector, the MG.CNCS prototype, which has been installed and tested at the Cold Neutron Chopper Spectrometer, CNCS at SNS. This has allowed a side-by-side comparison to the performance of $^3$He detectors on an operational instrument. The demonstrator has an active area of 0.2 m$^2$. It is specifically tailored to the specifications of CNCS. The detector was installed in June 2016 and has operated since then, collecting neutron scattering data in parallel to the He-3 detectors of CNCS. In this paper, we present a comprehensive analysis of this data, in particular on instrument energy resolution, rate capability, background and relative efficiency. Stability, gamma-ray and fast neutron sensitivity have also been investigated. The effect of scattering in the detector components has been measured and provides input to comparison for Monte Carlo simulations. All data is presented in comparison to that measured by the $^3$He detectors simultaneously, showing that all features recorded by one detector are also recorded by the other. The energy resolution matches closely. We find that the Multi-Grid is able to match the data collected by $^3$He, and see an indication of a considerable advantage in the count rate capability. Based on these results, we are confident that the Multi-Grid detector will be capable of producing high quality scientific data on chopper spectrometers utilising the unprecedented neutron flux of the ESS.
△ Less
Submitted 3 April, 2017; v1 submitted 10 March, 2017;
originally announced March 2017.
-
Investigation of background in large-area neutron detectors due to alpha emission from impurities in aluminium
Authors:
J. Birch,
J. -C. Buffet,
J. -F. Clergeau,
P. van Esch,
M. Ferraton,
B. Guerard,
R. Hall-Wilton,
L. Hultman,
C. Höglund,
J. Jensen,
A. Khaplanov,
F. Piscitelli
Abstract:
Thermal neutron detector based on films of $^{10}$B$_4$C have been developed as an alternative to $^3$He detectors. In particular, The Multi-Grid detector concept is considered for future large area detectors for ESS and ILL instruments. An excellent signal-to-background ratio is essential to attain expected scientific results. Aluminium is the most natural material for the mechanical structure of…
▽ More
Thermal neutron detector based on films of $^{10}$B$_4$C have been developed as an alternative to $^3$He detectors. In particular, The Multi-Grid detector concept is considered for future large area detectors for ESS and ILL instruments. An excellent signal-to-background ratio is essential to attain expected scientific results. Aluminium is the most natural material for the mechanical structure of of the Multi-Grid detector and other similar concepts due to its mechanical and neutronic properties. Due to natural concentration of $α$ emitters, however, the background from $α$ particles misidentified as neutrons can be unacceptably high. We present our experience operating a detector prototype affected by this issue. Monte Carlo simulations have been used to confirm the background as $α$ particles. The issues have been addressed in the more recent implementations of the Multi-Grid detector by the use of purified aluminium as well as Ni-plating of standard aluminium. The result is the reduction in background by two orders of magnitude. A new large-area prototype has been built incorporating these modifications.
△ Less
Submitted 16 September, 2015; v1 submitted 2 July, 2015;
originally announced July 2015.
-
Study of a high spatial resolution 10B-based thermal neutron detector for application in neutron reflectometry: the Multi-Blade prototype
Authors:
F. Piscitelli,
J. C. Buffet,
J. F. Clergeau,
S. Cuccaro,
B. Guerard,
A. Khaplanov,
Q. La Manna,
J. M. Rigal,
P. Van Esch
Abstract:
Although for large area detectors it is crucial to find an alternative to detect thermal neutrons because of the 3He shortage, this is not the case for small area detectors. Neutron scattering science is still growing its instruments' power and the neutron flux a detector must tolerate is increasing. For small area detectors the main effort is to expand the detectors' performances. At Institut Lau…
▽ More
Although for large area detectors it is crucial to find an alternative to detect thermal neutrons because of the 3He shortage, this is not the case for small area detectors. Neutron scattering science is still growing its instruments' power and the neutron flux a detector must tolerate is increasing. For small area detectors the main effort is to expand the detectors' performances. At Institut Laue-Langevin (ILL) we developed the Multi-Blade detector which wants to increase the spatial resolution of 3He-based detectors for high flux applications. We developed a high spatial resolution prototype suitable for neutron reflectometry instruments. It exploits solid 10B-films employed in a proportional gas chamber. Two prototypes have been constructed at ILL and the results obtained on our monochromatic test beam line are presented here.
△ Less
Submitted 9 December, 2013;
originally announced December 2013.
-
An Information-Theoretical Approach to Image Resolution Applied to Neutron Imaging Detectors based upon Individual Discriminator Signals
Authors:
Jean-François Clergeau,
Matthieu Ferraton,
Bruno Guérard,
Anton Khaplanov,
Francesco Piscitelli,
Martin Platz,
Jean-Marie Rigal,
Patrick Van Esch,
Thibault Daullé
Abstract:
1D or 2D neutron imaging detectors with individual wire or strip readout using discriminators have the advantage of being able to treat several neutron impacts partially overlapping in time, hence reducing global dead time. A single neutron impact usually gives rise to several discriminator signals. In this paper, we introduce an information-theoretical definition of image resolution. Two point-li…
▽ More
1D or 2D neutron imaging detectors with individual wire or strip readout using discriminators have the advantage of being able to treat several neutron impacts partially overlapping in time, hence reducing global dead time. A single neutron impact usually gives rise to several discriminator signals. In this paper, we introduce an information-theoretical definition of image resolution. Two point-like spots of neutron impacts with a given distance between them act as a source of information (each neutron hit belongs to one spot or the other), and the detector plus signal treatment is regarded as an imperfect communication channel that transmits this information. The maximal mutual information obtained from this channel as a function of the distance between the spots allows to define a calibration-independent measure of resolution. We then apply this measure to quantify the power of resolution of different algorithms treating these individual discriminator signals which can be implemented in firmware. The method is then applied to different detectors existing at the ILL. Center-of-gravity methods usually improve the resolution over best-wire algorithms which are the standard way of treating these signals.
△ Less
Submitted 29 July, 2013;
originally announced July 2013.
-
Investigation of gamma-ray sensitivity of neutron detectors based on thin converter films
Authors:
Anton Khaplanov,
Francesco Piscitelli,
Jean-Claude Buffet,
Jean-Francois Clergeau,
Jonathan Correa,
Patrick van Esch,
Mathieu Ferraton,
Bruno Guerard,
Richard Hall-Wilton
Abstract:
Currently, many detector technologies for thermal neutron detection are in development in order to lower the demand for the rare 3He gas. Gas detectors with solid thin film neutron converters readout by gas proportional counter method have been proposed as an appropriate choice for applications where large area coverage is necessary. In this paper, we investigate the probability for gamma-rays to…
▽ More
Currently, many detector technologies for thermal neutron detection are in development in order to lower the demand for the rare 3He gas. Gas detectors with solid thin film neutron converters readout by gas proportional counter method have been proposed as an appropriate choice for applications where large area coverage is necessary. In this paper, we investigate the probability for gamma-rays to generate a false count in a neutron measurement. Simulated results are compared to measurement with a 10B thin film prototype and a 3He detector. It is demonstrated that equal gamma-ray rejection to that of 3He tubes is achieved with the new technology. The arguments and results presented here are also applicable to gas detectors with converters other than solid 10B layers, such as 6Li layers and 10BF3 gas.
△ Less
Submitted 26 June, 2013;
originally announced June 2013.
-
An Electrostatic Lens to Reduce Parallax in Banana Gas Detectors
Authors:
Patrick Van Esch,
Jean-Francois Clergeau,
Kadda Medjoubi
Abstract:
Cylindrical "banana" gas detectors are often used in fixed-target experiments, because they are free of parallax effects in the equatorial plane. However, there is a growing demand to increase the height of these detectors in order to be more efficient or to cover more solid angle, and hence a parallax effect starts to limit the resolution in that direction. In this paper we propose a hardware c…
▽ More
Cylindrical "banana" gas detectors are often used in fixed-target experiments, because they are free of parallax effects in the equatorial plane. However, there is a growing demand to increase the height of these detectors in order to be more efficient or to cover more solid angle, and hence a parallax effect starts to limit the resolution in that direction. In this paper we propose a hardware correction for this problem which reduces the parallax error thanks to an applied potential on the front window that makes the electrostatic field lines radially pointing to the interaction point at the entrance window. A detailed analytical analysis of the solution is also presented.
△ Less
Submitted 4 August, 2006;
originally announced August 2006.