Proton irradiation on Hydrogenated Amorphous Silicon flexible devices
Authors:
M. Menichelli,
S. Aziz,
A. Bashiri,
M. Bizzarri,
C. Buti,
L. Calcagnile,
D. Calvo,
M. Caprai,
D. Caputo,
A. P. Caricato,
R. Catalano,
M. Cazzanelli,
R. Cirio,
G. A. P. Cirrone,
F. Cittadini,
T. Croci,
G. Cuttone,
G. de Cesare,
P. De Remigis,
S. Dunand,
M. Fabi,
L. Frontini,
C. Grimani,
M. Guarrera,
H. Hasnaoui
, et al. (36 additional authors not shown)
Abstract:
Radiation damage tests in hydrogenated amorphous silicon (a-Si:H) flexible flux and dose-measuring devices have been performed with a 3 MeV proton beam, to evaluate combined displacement and total ionizing dose damage. The tested devices had two different configurations and thicknesses. The first device was a 2 um thick n-i-p diode having a 5 mm x 5 mm area. The second device was a 5 um thick char…
▽ More
Radiation damage tests in hydrogenated amorphous silicon (a-Si:H) flexible flux and dose-measuring devices have been performed with a 3 MeV proton beam, to evaluate combined displacement and total ionizing dose damage. The tested devices had two different configurations and thicknesses. The first device was a 2 um thick n-i-p diode having a 5 mm x 5 mm area. The second device was a 5 um thick charge selective contact detector having the same area. Both the devices were deposited on a flexible polyimide substrate and were irradiated up to the fluence of 1016 neq/cm2. The response to different proton fluxes has been measured before irradiation and after irradiation at 1016 neq/cm2 for charge-selective contacts and n-i-p devices. The effect of annealing for partial performance recovery at 100°C for 12 hours was also studied and a final characterization on annealed devices was performed. This test is the first combined displacement and total ionizing dose test on flexible a-Si:H devices.
△ Less
Submitted 17 December, 2024;
originally announced December 2024.
-
Characterization of a modified clinical linear accelerator for ultra-high dose rate electron beam delivery
Authors:
Umberto Deut,
Aurora Camperi,
Cristiano Cavicchi,
Roberto Cirio,
Emanuele Data,
Elisabetta Durisi,
Veronica Ferrero,
Arianna Ferro,
Simona Giordanengo,
Oscar A. Martì Villarreal,
Felix Mas Milian,
Elisabetta Medina,
Diango M. Montalvan Olivares,
Franco Mostardi,
Valeria Monti,
Roberto Sacchi,
Edoardo Salmeri,
Anna Vignati
Abstract:
Irradiations at Ultra High Dose Rate (UHDR) regimes, exceeding 40 Gy/s in single fractions lasting less than 200 ms, have shown an equivalent antitumor effect compared to conventional radio-therapy with reduced harm to normal tissues. This work details the hardware and software modi-fications implemented to deliver 10 MeV UHDR electron beams with a Linear Accelerator Elekta SL 18 MV and the beam c…
▽ More
Irradiations at Ultra High Dose Rate (UHDR) regimes, exceeding 40 Gy/s in single fractions lasting less than 200 ms, have shown an equivalent antitumor effect compared to conventional radio-therapy with reduced harm to normal tissues. This work details the hardware and software modi-fications implemented to deliver 10 MeV UHDR electron beams with a Linear Accelerator Elekta SL 18 MV and the beam characteristics obtained. GafChromic EBT XD films and an Advanced Markus chamber were used for the dosimetry characterization, while a silicon sensor assessed the machine's beam pulses stability and repeatability. Dose per pulse, average dose rate and instantaneous dose rate in the pulse were evaluated for four experimental settings, varying the source-to-surface dis-tance and the beam collimation, i.e. with and without the use of a cylindrical applicator. Results showed dose per pulse from 0.6 Gy to a few tens of Gy and average dose rate up to 300 Gy/s. The obtained results demonstrate the possibility to perform in-vitro radiobiology experiments and test of new technologies for beam monitoring and dosimetry at the upgraded LINAC, thus contributing to the electron UHDR research field.
△ Less
Submitted 22 July, 2024;
originally announced July 2024.
-
Data acquisition system for a 146-channel counter of protons in particle therapy
Authors:
S. Giordanengo,
M. Abujami,
C. Galeone,
S. Garbolino,
O. A. Martì Villarreal,
F. Mas Milian,
G. Mazza,
M. Mignone,
A. Vignati,
R. Wheadon,
R. Cirio,
V. Monaco,
R. Sacchi
Abstract:
A prototype of proton counter was developed by the University and the National Institute for Nuclear Physics of Torino to be used as online fluence beam monitor in particle therapy. The single particle identification approach aims at increasing the sensitivity and readout speed with respect to the state-of-the-art gas ionization chambers. The sensitive area is 2,7 x 2,7 cm^2 to cover the clinical…
▽ More
A prototype of proton counter was developed by the University and the National Institute for Nuclear Physics of Torino to be used as online fluence beam monitor in particle therapy. The single particle identification approach aims at increasing the sensitivity and readout speed with respect to the state-of-the-art gas ionization chambers. The sensitive area is 2,7 x 2,7 cm^2 to cover the clinical beam cross section characterized by a full width at half maximum of about 1 cm at the isocenter. The sensor is a thin Low Gain Avalanche Diode segmented in 146 strips with 180 micrometer pitch and with 50 micrometer active thickness, designed and produced by the Fondazione Bruno Kessler (Trento, Italy). The frontend readout to identify the single proton signal provided by each strip is based on a 24channel custom ASICs, named ABACUS, optimized to discriminate the signal pulses in a wide charge range (3-150 fC) with a maximum dead-time of 10 ns. With these specifications, at the maximum fluence rate of 10^8 p/(cm^2s) in the clinical energy range (60-230 MeV) and considering the silicon strips described above, a maximum pileup counting inefficiency less than 1 percent is achieved. A frontend board housing 6 ABACUS chips to readout the 146 strips was developed, the digital outputs being sent to 3 FPGAs (Kintex7) for the counting. A LabVIEW program implements the interface with the FPGAs, displays online the counting rate from each strip and stores the data for offline analysis.
△ Less
Submitted 6 May, 2022;
originally announced May 2022.
-
The CNAO Dose Delivery System for modulated scanning ion beam radiotherapy
Authors:
Simona Giordanengo,
Maria Adelaide Garella,
Flavio Marchetto,
Faiza Bourhaleb,
Mario Ciocca,
Alfredo Mirandola,
Vincenzo Monaco,
Mohammad Amin Hosseini,
Cristian Peroni,
Roberto Sacchi,
Roberto Cirio,
Marco Donetti
Abstract:
This paper describes the dose delivery system used at the Centro Nazionale di Adroterapia Oncologica (CNAO) for ion beam modulated scanning radiotherapy. CNAO Foundation, INFN and University of Torino have developed and commissioned a Dose Delivery System (DDS) to monitor and guide ion beams accelerated by a synchrotron and to distribute the dose with a 3D scanning technique. The target volume, se…
▽ More
This paper describes the dose delivery system used at the Centro Nazionale di Adroterapia Oncologica (CNAO) for ion beam modulated scanning radiotherapy. CNAO Foundation, INFN and University of Torino have developed and commissioned a Dose Delivery System (DDS) to monitor and guide ion beams accelerated by a synchrotron and to distribute the dose with a 3D scanning technique. The target volume, segmented in several layers orthogonally to the beam direction, is irradiated by thousands of pencil beams which must be steered and held to the prescribed positions until the prescribed number of particles has been delivered. At CNAO, these operations are performed by the DDS. The main components of this system are 2 independent beam monitoring detectors (BOX1 and BOX2), interfaced with 2 control systems performing real-time control, and connected to the scanning magnets and the beam chopper. As a reaction to any potential hazard, a DDS interlock signal is sent to the Patient Interlock System which immediately stops the irradiation. The tasks and operations performed by the DDS are described following the data flow from the Treatment Planning System through the end of the treatment delivery. The ability of the DDS to guarantee a safe and accurate treatment was validated during the commissioning phase by means of checks of the charge collection efficiency, gain uniformity of the chambers and 2D dose distribution homogeneity and stability. A high level of reliability and robustness has been proven by 3 years of system activity. The DDS described in this paper is one among the few worldwide existing systems to operate ion beam for modulated scanning radiotherapy. It has proven to guide and control the therapeutic pencil beams with accuracy and stability showing dose deviations lower than the acceptance threshold of 5% and 2.5% respectively during daily Quality Assurance measurements.
△ Less
Submitted 26 January, 2022;
originally announced January 2022.
-
A new detector for the beam energy measurement in proton therapy: a feasibility study
Authors:
A. Vignati,
S. Giordanengo,
F. Mas Milian,
Z. Ahmadi Ganjeh,
M. Donetti,
F. Fausti,
M. Ferrero,
O. Hammad Ali,
O. A. Martì Villarreal,
G. Mazza,
Z. Shakarami,
V. Sola,
A. Staiano,
R. Cirio,
R. Sacchi,
V. Monaco,
.
Abstract:
Fast procedures for the beam quality assessment and for the monitoring of beam energy modulations during the irradiation are among the most urgent improvements in particle therapy. Indeed, the online measurement of the particle beam energy could allow assessing the range of penetration during treatments, encouraging the development of new dose delivery techniques for moving targets. Towards this e…
▽ More
Fast procedures for the beam quality assessment and for the monitoring of beam energy modulations during the irradiation are among the most urgent improvements in particle therapy. Indeed, the online measurement of the particle beam energy could allow assessing the range of penetration during treatments, encouraging the development of new dose delivery techniques for moving targets. Towards this end, the proof of concept of a new device, able to measure in a few seconds the energy of clinical proton beams (from 60 to 230 MeV) from the Time of Flight (ToF) of protons, is presented. The prototype consists of two Ultra Fast Silicon Detector (UFSD) pads, featuring an active thickness of 80 um and a sensitive area of 3 x 3 mm2, aligned along the beam direction in a telescope configuration, connected to a broadband amplifier and readout by a digitizer. Measurements were performed at the Centro Nazionale di Adroterapia Oncologica (CNAO, Pavia, Italy), at five different clinical beam energies and four distances between the sensors (from 7 to 97 cm) for each energy. In order to derive the beam energy from the measured average ToF, several systematic effects were considered, Monte Carlo simulations were developed to validate the method and a global fit approach was adopted to calibrate the system. The results were benchmarked against the energy values obtained from the water equivalent depths provided by CNAO. Deviations of few hundreds of keV have been achieved for all considered proton beam energies for both 67 and 97 cm distances between the sensors and few seconds of irradiation were necessary to collect the required statistics. These preliminary results indicate that a telescope of UFSDs could achieve in a few seconds the accuracy required for the clinical application and therefore encourage further investigations towards the improvement and the optimization of the present prototype.
△ Less
Submitted 19 March, 2020;
originally announced March 2020.
-
Beam test results of a 16 ps timing system based on ultra-fast silicon detectors
Authors:
N. Cartiglia,
A. Staiano,
V. Sola,
R. Arcidiacono,
R. Cirio,
F. Cenna,
M. Ferrero,
V. Monaco,
R. Mulargia,
M. Obertino,
F. Ravera,
R. Sacchi,
A. Bellora,
S. Durando,
M. Mandurrino,
N. Minafra,
V. Fadeyev,
P. Freeman,
Z. Galloway,
E. Gkougkousis,
H. Grabas,
B. Gruey,
C. A. Labitan,
R. Losakul,
Z. Luce
, et al. (18 additional authors not shown)
Abstract:
In this paper we report on the timing resolution of the first production of 50 micro-meter thick Ultra-Fast Silicon Detectors (UFSD) as obtained in a beam test with pions of 180 GeV/c momentum. UFSD are based on the Low-Gain Avalanche Detectors (LGAD) design, employing n-on-p silicon sensors with internal charge multiplication due to the presence of a thin, low-resistivity diffusion layer below th…
▽ More
In this paper we report on the timing resolution of the first production of 50 micro-meter thick Ultra-Fast Silicon Detectors (UFSD) as obtained in a beam test with pions of 180 GeV/c momentum. UFSD are based on the Low-Gain Avalanche Detectors (LGAD) design, employing n-on-p silicon sensors with internal charge multiplication due to the presence of a thin, low-resistivity diffusion layer below the junction. The UFSD used in this test belongs to the first production of thin (50 μm) sensors, with an pad area of 1.4 mm2. The gain was measured to vary between 5 and 70 depending on the bias voltage. The experimental setup included three UFSD and a fast trigger consisting of a quartz bar readout by a SiPM. The timing resolution, determined comparing the time of arrival of the particle in one or more UFSD and the trigger counter, for single UFSD was measured to be 35 ps for a bias voltage of 200 V, and 26 ps for a bias voltage of 240 V, and for the combination of 3 UFSD to be 20 ps for a bias voltage of 200 V, and 15 ps for a bias voltage of 240 V.
△ Less
Submitted 3 January, 2017; v1 submitted 30 August, 2016;
originally announced August 2016.