Development of the Soft X-ray AGM-AGS RIXS Beamline at Taiwan Photon Source
Authors:
A. Singh,
H. Y. Huang,
Y. Y. Chu,
C. Y. Hua,
S. W. Lin,
H. S. Fung,
H. W. Shiu,
J. Chang,
J. H. Li,
J. Okamoto,
C. C. Chiu,
C. H. Chang,
W. B. Wu,
S. Y. Perng,
S. C. Chung,
K. Y. Kao,
S. C. Yeh,
H. Y. Chao,
J. H. Chen,
D. J. Huang,
C. T. Chen
Abstract:
We report on the development of a high-resolution and highly efficient beamline for soft-X-ray resonant inelastic X-ray scattering (RIXS) located at Taiwan Photon Source. This beamline adopts an optical design that uses an active grating monochromator (AGM) and an active grating spectrometer (AGS) to implement the energy compensation principle of grating dispersion. Active gratings are utilized to…
▽ More
We report on the development of a high-resolution and highly efficient beamline for soft-X-ray resonant inelastic X-ray scattering (RIXS) located at Taiwan Photon Source. This beamline adopts an optical design that uses an active grating monochromator (AGM) and an active grating spectrometer (AGS) to implement the energy compensation principle of grating dispersion. Active gratings are utilized to diminish defocus, coma and higher-order aberrations as well as to decrease the slope errors caused by thermal deformation and optical polishing. The AGS is mounted on a rotatable granite platform to enable momentum-resolved RIXS measurements with scattering angle over a wide range. Several high-precision instruments developed in house for this beamline are briefly described. The best energy resolution obtained from this AGM-AGS beamline was 12.4 meV at 530 eV, achieving a resolving power 42,000, while the bandwidth of the incident soft X-rays was kept at 0.5 eV. To demonstrate the scientific impacts of high-resolution RIXS, we present an example of momentum-resolved RIXS measurements on a high-temperature superconducting cuprate, La$_{2-x}$Sr$_x$CuO$_4$. The measurements reveal the A$_{1g}$ apical oxygen phonons in superconducting cuprates, opening a new opportunity to investigate the coupling between these phonons and charge density waves.
△ Less
Submitted 24 June, 2020; v1 submitted 23 June, 2020;
originally announced June 2020.
Experimental evidence of the spin selection rule in KLL Auger transition
Authors:
D. J. Huang,
W. P. Wu,
C. F. Chang,
J. Chen,
S. C. Chung,
L. H. Tjeng,
C. T. Chen,
S. G. Shyu,
C. C. Wu
Abstract:
With on- and off- resonant excitation photons, spin-resolved Auger electron spectra of epitaxial CrO$_{2}$ thin films show an experimental evidence of the spin-selective KLL Auger decay. The on-resonance O KLL Auger electrons are found to be highly spin-polarized, while the off-resonance ones with almost zero spin polarization. These results lead to conclude that the two-hole final state in KLL…
▽ More
With on- and off- resonant excitation photons, spin-resolved Auger electron spectra of epitaxial CrO$_{2}$ thin films show an experimental evidence of the spin-selective KLL Auger decay. The on-resonance O KLL Auger electrons are found to be highly spin-polarized, while the off-resonance ones with almost zero spin polarization. These results lead to conclude that the two-hole final state in KLL Auger decay is a spin-singlet. Applications to spin-resolved absorption spectroscopy are discussed.
△ Less
Submitted 12 July, 2001; v1 submitted 11 July, 2001;
originally announced July 2001.