Seven-Probe Fiber Detector for Time-Resolved Source Tracking in HDR-Brachytherapy: Experimental Evaluation
Authors:
Mathieu Gonod,
Miguel Angel Suarez,
Samir Laskri,
Gwenael Rolin,
Karine Charriere,
Emmanuel Dordor,
Julien Crouzilles,
Thomas Lihoreau,
Lionel Pazart,
Jean-Francois Vinchant,
Leone Aubignac,
Thierry Grosjean
Abstract:
{\bf Purpose:} This study evaluates a compact biocompatible Seven-probe Scintillator Detector (7SD) for monitoring HDR-BT treatment sequences across a range of dwell times and source-probe spacings representative of most HDR-BT techniques.
{\bf Methods:} The SSD comprises seven detection cells made of Gd$_2$O$_2$S:Tb, each measuring 0.28 $\pm$ 0.02 mm in diameter and 0.43 $\pm$ 0.02 mm in length…
▽ More
{\bf Purpose:} This study evaluates a compact biocompatible Seven-probe Scintillator Detector (7SD) for monitoring HDR-BT treatment sequences across a range of dwell times and source-probe spacings representative of most HDR-BT techniques.
{\bf Methods:} The SSD comprises seven detection cells made of Gd$_2$O$_2$S:Tb, each measuring 0.28 $\pm$ 0.02 mm in diameter and 0.43 $\pm$ 0.02 mm in length, coupled to the microstructured tips of silica optical fibers (110-micron diameter). The probes, spaced 15 mm apart along the fiber axis, are organized into a bundle with a total diameter of less than 0.45 mm. The SSD was tested using a MicroSelectron 9.1 Ci Ir-192 HDR afterloader connected to a BT stainless steel interstitial needle. Detection signals were acquired with an sCMOS camera equipped. Monitoring of dwell times and positions was performed by combining detection signals from all seven probes.
{\bf Results:} A total of 4,040 dwell positions were analyzed, covering source-probe spacings from 10 to 36 mm and a source travel range of 62 mm, with dwell times ranging from 0.1 to 19.5 s. The 7SD successfully identified 99.5\% of the dwell positions. In cylindrical coordinates, the measured dwell positions deviated from the planned values by 0.224 $\pm$ 0.155 mm (radial) and 0.077 $\pm$ 0.181 mm (axial, source travel axis). The average deviation from planned dwell times was 0.006 $\pm$ 0.061 s. 99.4\% of the dwell positions were measured within the 1 mm reliability threshold. The remaining 0.6\% of deviations consistently occurred at the initial dwell position of treatment sequences and appear to stem from a systematic source positioning error by the afterloader. Additionally, the detector accurately identified intentional needle mispositioning scenarios with sub-millimeter accuracy.
△ Less
Submitted 19 June, 2025;
originally announced June 2025.
-
Deep image mining for diabetic retinopathy screening
Authors:
Gwenolé Quellec,
Katia Charrière,
Yassine Boudi,
Béatrice Cochener,
Mathieu Lamard
Abstract:
Deep learning is quickly becoming the leading methodology for medical image analysis. Given a large medical archive, where each image is associated with a diagnosis, efficient pathology detectors or classifiers can be trained with virtually no expert knowledge about the target pathologies. However, deep learning algorithms, including the popular ConvNets, are black boxes: little is known about the…
▽ More
Deep learning is quickly becoming the leading methodology for medical image analysis. Given a large medical archive, where each image is associated with a diagnosis, efficient pathology detectors or classifiers can be trained with virtually no expert knowledge about the target pathologies. However, deep learning algorithms, including the popular ConvNets, are black boxes: little is known about the local patterns analyzed by ConvNets to make a decision at the image level. A solution is proposed in this paper to create heatmaps showing which pixels in images play a role in the image-level predictions. In other words, a ConvNet trained for image-level classification can be used to detect lesions as well. A generalization of the backpropagation method is proposed in order to train ConvNets that produce high-quality heatmaps. The proposed solution is applied to diabetic retinopathy (DR) screening in a dataset of almost 90,000 fundus photographs from the 2015 Kaggle Diabetic Retinopathy competition and a private dataset of almost 110,000 photographs (e-ophtha). For the task of detecting referable DR, very good detection performance was achieved: $A_z = 0.954$ in Kaggle's dataset and $A_z = 0.949$ in e-ophtha. Performance was also evaluated at the image level and at the lesion level in the DiaretDB1 dataset, where four types of lesions are manually segmented: microaneurysms, hemorrhages, exudates and cotton-wool spots. The proposed detector outperforms recent algorithms trained to detect those lesions specifically, as well as competing heatmap generation algorithms for ConvNets. This detector is part of the Messidor system for mobile eye pathology screening. Because it does not rely on expert knowledge or manual segmentation for detecting relevant patterns, the proposed solution is a promising image mining tool, which has the potential to discover new biomarkers in images.
△ Less
Submitted 28 April, 2017; v1 submitted 22 October, 2016;
originally announced October 2016.
-
Real-time analysis of cataract surgery videos using statistical models
Authors:
Katia Charrière,
Gwenolé Quellec,
Mathieu Lamard,
David Martiano,
Guy Cazuguel,
Gouenou Coatrieux,
Béatrice Cochener
Abstract:
The automatic analysis of the surgical process, from videos recorded during surgeries, could be very useful to surgeons, both for training and for acquiring new techniques. The training process could be optimized by automatically providing some targeted recommendations or warnings, similar to the expert surgeon's guidance. In this paper, we propose to reuse videos recorded and stored during catara…
▽ More
The automatic analysis of the surgical process, from videos recorded during surgeries, could be very useful to surgeons, both for training and for acquiring new techniques. The training process could be optimized by automatically providing some targeted recommendations or warnings, similar to the expert surgeon's guidance. In this paper, we propose to reuse videos recorded and stored during cataract surgeries to perform the analysis. The proposed system allows to automatically recognize, in real time, what the surgeon is doing: what surgical phase or, more precisely, what surgical step he or she is performing. This recognition relies on the inference of a multilevel statistical model which uses 1) the conditional relations between levels of description (steps and phases) and 2) the temporal relations among steps and among phases. The model accepts two types of inputs: 1) the presence of surgical tools, manually provided by the surgeons, or 2) motion in videos, automatically analyzed through the Content Based Video retrieval (CBVR) paradigm. Different data-driven statistical models are evaluated in this paper. For this project, a dataset of 30 cataract surgery videos was collected at Brest University hospital. The system was evaluated in terms of area under the ROC curve. Promising results were obtained using either the presence of surgical tools ($A_z$ = 0.983) or motion analysis ($A_z$ = 0.759). The generality of the method allows to adapt it to any kinds of surgeries. The proposed solution could be used in a computer assisted surgery tool to support surgeons during the surgery.
△ Less
Submitted 18 October, 2016;
originally announced October 2016.