Planck early results: first assessment of the High Frequency Instrument in-flight performance
Authors:
Planck HFI Core Team,
P. A. R. Ade,
N. Aghanim,
R. Ansari,
M. Arnaud,
M. Ashdown,
J. Aumont,
A. J. Banday,
M. Bartelmann,
J. G. Bartlett,
E. Battaner,
K. Benabed,
A. Benot,
J. -P. Bernard,
M. Bersanelli,
R. Bhatia,
J. J. Bock,
J. R. Bond,
J. Borrill,
F. R. Bouchet,
F. Boulanger,
T. Bradshaw,
E. Brelle,
M. Bucher,
P. Camus
, et al. (141 additional authors not shown)
Abstract:
The Planck High Frequency Instrument (HFI) is designed to measure the temperature and polarization anisotropies of the Cosmic Microwave Background and galactic foregrounds in six wide bands centered at 100, 143, 217, 353, 545 and 857 GHz at an angular resolution of 10' (100 GHz), 7' (143 GHz), and 5' (217 GHz and higher). HFI has been operating flawlessly since launch on 14 May 2009. The bolometer…
▽ More
The Planck High Frequency Instrument (HFI) is designed to measure the temperature and polarization anisotropies of the Cosmic Microwave Background and galactic foregrounds in six wide bands centered at 100, 143, 217, 353, 545 and 857 GHz at an angular resolution of 10' (100 GHz), 7' (143 GHz), and 5' (217 GHz and higher). HFI has been operating flawlessly since launch on 14 May 2009. The bolometers cooled to 100 mK as planned. The settings of the readout electronics, such as the bolometer bias current, that optimize HFI's noise performance on orbit are nearly the same as the ones chosen during ground testing. Observations of Mars, Jupiter, and Saturn verified both the optical system and the time response of the detection chains. The optical beams are close to predictions from physical optics modeling. The time response of the detection chains is close to pre-launch measurements. The detectors suffer from an unexpected high flux of cosmic rays related to low solar activity. Due to the redundancy of Planck's observations strategy, the removal of a few percent of data contaminated by glitches does not affect significantly the sensitivity. The cosmic rays heat up significantly the bolometer plate and the modulation on periods of days to months of the heat load creates a common drift of all bolometer signals which do not affect the scientific capabilities. Only the high energy cosmic rays showers induce inhomogeneous heating which is a probable source of low frequency noise.
△ Less
Submitted 11 January, 2011;
originally announced January 2011.
-
Planck Early Results. II. The thermal performance of Planck
Authors:
Planck Collaboration,
P. A. R. Ade,
N. Aghanim,
M. Arnaud,
M. Ashdown,
J. Aumont,
C. Baccigalupi,
M. Baker,
A. Balbi,
A. J. Banday,
R. B. Barreiro,
E. Battaner,
K. Benabed,
A. Benoit,
J. P. Bernard,
M. Bersanelli,
P. Bhandari,
R. Bhatia,
J. J. Bock,
A. Bonaldi,
J. R. Bond,
J. Borders,
J. Borrill,
F. R. Bouchet,
B. Bowman
, et al. (203 additional authors not shown)
Abstract:
The performance of the Planck instruments in space is enabled by their low operating temperatures, 20K for LFI and 0.1K for HFI, achieved through a combination of passive radiative cooling and three active mechanical coolers. The scientific requirement for very broad frequency coverage led to two detector technologies with widely different temperature and cooling needs. Active coolers could satisf…
▽ More
The performance of the Planck instruments in space is enabled by their low operating temperatures, 20K for LFI and 0.1K for HFI, achieved through a combination of passive radiative cooling and three active mechanical coolers. The scientific requirement for very broad frequency coverage led to two detector technologies with widely different temperature and cooling needs. Active coolers could satisfy these needs; a helium cryostat, as used by previous cryogenic space missions (IRAS, COBE, ISO, Spitzer, AKARI), could not. Radiative cooling is provided by three V-groove radiators and a large telescope baffle. The active coolers are a hydrogen sorption cooler (<20K), a 4He Joule-Thomson cooler (4.7K), and a 3He-4He dilution cooler (1.4K and 0.1K). The flight system was at ambient temperature at launch and cooled in space to operating conditions. The HFI bolometer plate reached 93mK on 3 July 2009, 50 days after launch. The solar panel always faces the Sun, shadowing the rest of Planck, andoperates at a mean temperature of 384K. At the other end of the spacecraft, the telescope baffle operates at 42.3K and the telescope primary mirror operates at 35.9K. The temperatures of key parts of the instruments are stabilized by both active and passive methods. Temperature fluctuations are driven by changes in the distance from the Sun, sorption cooler cycling and fluctuations in gas-liquid flow, and fluctuations in cosmic ray flux on the dilution and bolometer plates. These fluctuations do not compromise the science data.
△ Less
Submitted 2 January, 2012; v1 submitted 11 January, 2011;
originally announced January 2011.
-
Planck Early Results: The Planck mission
Authors:
Planck Collaboration,
P. A. R. Ade,
N. Aghanim,
M. Arnaud,
M. Ashdown,
J. Aumont,
C. Baccigalupi,
M. Baker,
A. Balbi,
A. J. Banday,
R. B. Barreiro,
J. G. Bartlett,
E. Battaner,
K. Benabed,
K. Bennett,
A. BenoƮt,
J. -P. Bernard,
M. Bersanelli,
R. Bhatia,
J. J. Bock,
A. Bonaldi,
J. R. Bond,
J. Borrill,
F. R. Bouchet,
T. Bradshaw
, et al. (250 additional authors not shown)
Abstract:
The European Space Agency's Planck satellite was launched on 14 May 2009, and has been surveying the sky stably and continuously since 13 August 2009. Its performance is well in line with expectations, and it will continue to gather scientific data until the end of its cryogenic lifetime. We give an overview of the history of Planck in its first year of operations, and describe some of the key per…
▽ More
The European Space Agency's Planck satellite was launched on 14 May 2009, and has been surveying the sky stably and continuously since 13 August 2009. Its performance is well in line with expectations, and it will continue to gather scientific data until the end of its cryogenic lifetime. We give an overview of the history of Planck in its first year of operations, and describe some of the key performance aspects of the satellite. This paper is part of a package submitted in conjunction with Planck's Early Release Compact Source Catalogue, the first data product based on Planck to be released publicly. The package describes the scientific performance of the Planck payload, and presents results on a variety of astrophysical topics related to the sources included in the Catalogue, as well as selected topics on diffuse emission.
△ Less
Submitted 16 June, 2011; v1 submitted 11 January, 2011;
originally announced January 2011.
-
The Planck High Frequency Instrument, a 3rd generation CMB experiment, and a full sky submillimeter survey
Authors:
J. M. Lamarre,
J. L. Puget,
F. Bouchet,
P. A. R. Ade,
A. Benoit,
J. P. Bernard,
J. Bock,
P. De Bernardis,
J. Charra,
F. Couchot,
J. Delabrouille,
G. Efstathiou,
M. Giard,
G. Guyot,
A. Lange,
B. Maffei,
A. Murphy,
F. Pajot,
M. Piat,
I. Ristorcelli,
D. Santos,
R. Sudiwala,
J. F. Sygnet,
J. P. Torre,
V. Yurchenko
, et al. (1 additional authors not shown)
Abstract:
The High Frequency Instrument (HFI) of Planck is the most sensitive CMB experiment ever planned. Statistical fluctuations (photon noise) of the CMB itself will be the major limitation to the sensitivity of the CMB channels. Higher frequency channels will measure galactic foregrounds. Together with the Low Frequency Instrument, this will make a unique tool to measure the full sky and to separate…
▽ More
The High Frequency Instrument (HFI) of Planck is the most sensitive CMB experiment ever planned. Statistical fluctuations (photon noise) of the CMB itself will be the major limitation to the sensitivity of the CMB channels. Higher frequency channels will measure galactic foregrounds. Together with the Low Frequency Instrument, this will make a unique tool to measure the full sky and to separate the various components of its spectrum. Measurement of the polarization of these various components will give a new picture of the CMB. In addition, HFI will provide the scientific community with new full sky maps of intensity and polarization at six frequencies, with unprecedented angular resolution and sensitivity. This paper describes the logics that prevailed to define the HFI and the performances expected from this instrument. It details several features of the HFI design that have not been published up to now.
△ Less
Submitted 5 August, 2003;
originally announced August 2003.
-
Are Solar Acoustic Modes Correlated ?
Authors:
T. Foglizzo,
R. A. Garcia,
P. Boumier,
J. Charra,
A. H. Gabriel,
G. Grec,
J. M. Robillot,
T. Roca Cortes,
S. Turck-Chieze,
R. K. Ulrich
Abstract:
We have studied the statistical properties of the energy of individual acoustic modes, extracted from 310 days of GOLF data near the solar minimum. The exponential distribution of the energy of each mode is clearly seen. The modes are found to be uncorrelated with a +-0.6 % accuracy, thus supporting the hypothesis of stochastic excitation by the solar convection. Nevertheless, the same analysis…
▽ More
We have studied the statistical properties of the energy of individual acoustic modes, extracted from 310 days of GOLF data near the solar minimum. The exponential distribution of the energy of each mode is clearly seen. The modes are found to be uncorrelated with a +-0.6 % accuracy, thus supporting the hypothesis of stochastic excitation by the solar convection. Nevertheless, the same analysis performed on the same modes just before the solar maximum, using IPHIR data, rejects the hypothesis of no correlation at a 99.3 % confidence level. A simple model suggests that 31.3 +-9.4 % of the energy of each mode is coherent among the modes studied in IPHIR data, correponding to a mean correlation of 10.7 +-5.9 %.
△ Less
Submitted 10 September, 1997;
originally announced September 1997.