SARGDV: Efficient identification of groundwater-dependent vegetation using synthetic aperture radar
Authors:
Mason Terrett,
Daniel Fryer,
Tanya Doody,
Hien Nguyen,
Pascal Castellazzi
Abstract:
Groundwater depletion impacts the sustainability of numerous groundwater-dependent vegetation (GDV) globally, placing significant stress on their capacity to provide environmental and ecological support for flora, fauna, and anthropic benefits. Industries such as mining, agriculture, and plantations are heavily reliant on groundwater, the over-exploitation of which risks impacting groundwater regi…
▽ More
Groundwater depletion impacts the sustainability of numerous groundwater-dependent vegetation (GDV) globally, placing significant stress on their capacity to provide environmental and ecological support for flora, fauna, and anthropic benefits. Industries such as mining, agriculture, and plantations are heavily reliant on groundwater, the over-exploitation of which risks impacting groundwater regimes, quality, and accessibility for nearby GDVs. Cost effective methods of GDV identification will enable strategic protection of these critical ecological systems, through improved and sustainable groundwater management by communities and industry. Recent application of synthetic aperture radar (SAR) earth observation data in Australia has demonstrated the utility of radar for identifying terrestrial groundwater-dependent ecosystems at scale. We propose a robust classification method to advance identification of GDVs at scale using processed SAR data products adapted from a recent previous method. The method includes the development of SARGDV, a binary classification model, which uses the extreme gradient boosting (XGBoost) algorithm in conjunction with three data cubes composed of Sentinel-1 SAR interferometric wide images. The images were collected as a one-year time series over Mount Gambier, a region in South Australia, known to support GDVs. The SARGDV model demonstrated high performance for classifying GDVs with 77% precision, 76% true positive rate and 96% accuracy. This method may be used to support the protection of GDV communities globally by providing a long term, cost-effective solution to identify GDVs over variable regions and climates, via the use of freely available, high-resolution, globally available Sentinel-1 SAR data sets.
△ Less
Submitted 7 September, 2020;
originally announced September 2020.
$k$-means on Positive Definite Matrices, and an Application to Clustering in Radar Image Sequences
Authors:
Daniel Fryer,
Hien Nguyen,
Pascal Castellazzi
Abstract:
We state theoretical properties for $k$-means clustering of Symmetric Positive Definite (SPD) matrices, in a non-Euclidean space, that provides a natural and favourable representation of these data. We then provide a novel application for this method, to time-series clustering of pixels in a sequence of Synthetic Aperture Radar images, via their finite-lag autocovariance matrices.
We state theoretical properties for $k$-means clustering of Symmetric Positive Definite (SPD) matrices, in a non-Euclidean space, that provides a natural and favourable representation of these data. We then provide a novel application for this method, to time-series clustering of pixels in a sequence of Synthetic Aperture Radar images, via their finite-lag autocovariance matrices.
△ Less
Submitted 25 August, 2020; v1 submitted 8 August, 2020;
originally announced August 2020.
MicroSQUID Force microscopy in a dilution refrigerator
Authors:
Danny Hykel,
Zhao-Sheng Wang,
Pauline Castellazzi,
Thierry Crozes,
Gorky Shaw,
Klaus Hasselbach,
K. F. Schuster
Abstract:
We present a new generation of a scanning MicroSQUID microscope operating in an inverted dilution refrigerator. The MicroSQUIDs have a size of 1.21$ \ μ$m\textsuperscript{2} and a magnetic flux sensitivity of 120 $μΦ_{0} / \sqrt{\textrm{Hz}}$ and thus a field sensitivity of %$550^{-6} \ Φ_{0} / \sqrt{\textrm{Hz}}$ 550$ \ μ\textrm{G}/ \sqrt{\textrm{Hz}}$. The scan range at low temperatures is about…
▽ More
We present a new generation of a scanning MicroSQUID microscope operating in an inverted dilution refrigerator. The MicroSQUIDs have a size of 1.21$ \ μ$m\textsuperscript{2} and a magnetic flux sensitivity of 120 $μΦ_{0} / \sqrt{\textrm{Hz}}$ and thus a field sensitivity of %$550^{-6} \ Φ_{0} / \sqrt{\textrm{Hz}}$ 550$ \ μ\textrm{G}/ \sqrt{\textrm{Hz}}$. The scan range at low temperatures is about 80 $μ$m and a coarse displacement of 5 mm in x and y direction has been implemented. The MicroSQUID-to-sample distance is regulated using a tuning fork based force detection. A MicroSQUID-to-sample distance of 420 nm has been obtained. The reliable knowledge of this distance is necessary to obtain a trustworthy estimate of the absolute value of the superconducting penetration depth. An outlook will be given on the ongoing direction of development.
△ Less
Submitted 23 March, 2014;
originally announced March 2014.