Single-mode waveguides for GRAVITY II. Single-mode fibers and Fiber Control Unit
Authors:
G. Perrin,
L. Jocou,
K. Perraut,
J. Ph. Berger,
R. Dembet,
P. Fédou,
S. Lacour,
F. Chapron,
C. Collin,
S. Poulain,
V. Cardin,
F. Joulain,
F. Eisenhauer,
X. Haubois,
S. Gillessen,
M. Haug,
F. Hausmann,
P. Kervella,
P. Léna,
M. Lippa,
O. Pfuh,
S. Rabien,
A. Amorim,
W. Brandner,
C. Straubmeier
Abstract:
The 2nd generation VLTI instrument GRAVITY is a two-field infrared interferometer operating in the K band between 1.97 and 2.43 $μ$m with either the four 8 m or the four 1.8 m telescopes of the Very Large Telescope (VLT). Beams collected by the telescopes are corrected with adaptive optics systems and the fringes are stabilized with a fringe-tracking system. A metrology system allows the measureme…
▽ More
The 2nd generation VLTI instrument GRAVITY is a two-field infrared interferometer operating in the K band between 1.97 and 2.43 $μ$m with either the four 8 m or the four 1.8 m telescopes of the Very Large Telescope (VLT). Beams collected by the telescopes are corrected with adaptive optics systems and the fringes are stabilized with a fringe-tracking system. A metrology system allows the measurement of internal path lengths in order to achieve high-accuracy astrometry. High sensitivity and high interferometric accuracy are achieved thanks to (i) correction of the turbulent phase, (ii) the use of low-noise detectors, and (iii) the optimization of photometric and coherence throughput. Beam combination and most of the beam transport are performed with single-mode waveguides in vacuum and at low temperature. In this paper, we present the functions and performance achieved with weakly birefringent standard single-mode fiber systems in GRAVITY. Fibered differential delay lines (FDDLs) are used to dynamically compensate for up to 6 mm of delay between the science and reference targets. Fibered polarization rotators allow us to align polarizations in the instrument and make the single-mode beam combiner close to polarization neutral. The single-mode fiber system exhibits very low birefringence (less than 23°), very low attenuation (3.6-7 dB/km across the K band), and optimized differential dispersion (less than 2.04 $μ$rad cm2 at zero extension of the FDDLs). As a consequence, the typical fringe contrast losses due to the single-mode fibers are 6% to 10% in the lowest-resolution mode and 5% in the medium- and high-resolution modes of the instrument for a photometric throughput of the fiber chain of the order of 90%. There is no equivalent of this fiber system to route and modally filter beams with delay and polarization control in any other K-band beamcombiner.
△ Less
Submitted 19 January, 2024;
originally announced January 2024.
Time-resolving magnetic scattering on rare-earth ferrimagnets with a bright soft-X-ray high-harmonic source
Authors:
G. Fan,
K. Legare,
V. Cardin,
X. Xie,
E. Kaksis,
G. Andriukaitis,
A. Pugzlys,
B. E. Schmidt,
J. P. Wolf,
M. Hehn,
G. Malinowski,
B. Vodungbo,
E. Jal,
J. Luning,
N. Jaouen,
Z. Tao,
A. Baltuska,
F. Legare,
T. Balciunas
Abstract:
We demonstrate the first time-resolved X-ray resonant magnetic scattering (tr-XRMS) experiment at the N edge of Tb at 155 eV performed using a tabletop high-brightness high-harmonic generation (HHG) source. In contrast to static X-ray imaging applications, such optical-pump X-ray-probe studies pose a different set of challenges for the ultrafast driver laser because a high photon flux of X-rays re…
▽ More
We demonstrate the first time-resolved X-ray resonant magnetic scattering (tr-XRMS) experiment at the N edge of Tb at 155 eV performed using a tabletop high-brightness high-harmonic generation (HHG) source. In contrast to static X-ray imaging applications, such optical-pump X-ray-probe studies pose a different set of challenges for the ultrafast driver laser because a high photon flux of X-rays resonant with the N edge must be attained at a low repetition rate to avoid thermal damage of the sample. This laboratory-scale X-ray magnetic diffractometer is enabled by directly driving HHG in helium with terawatt-level 1 um laser fields, which are obtained through pulse compression after a high-energy kHz-repetition-rate Yb:CaF2 amplifier. The high peak power of the driving fields allows us to reach the fully phase-matching conditions in helium, which yields the highest photon flux (>2x10^9 photons/s/1% bandwidth) in the 100-220 eV spectral range, to the best of our knowledge. Our proof-of-concept tr-XRMS measurements clearly resolve the spatio-temporal evolution of magnetic domains in Co/Tb ferrimagnetic alloys with femtosecond and nanometer resolution. In addition to the ultrafast demagnetization, we observe magnetic domain expansion with a domain wall velocity similar to that induced by spin transfer torque. The demonstrated method opens up new opportunities for time-space-resolved magnetic scattering with elemental specificity on various magnetic, orbital and electronic orderings in condensed matter systems.
△ Less
Submitted 31 October, 2019;
originally announced October 2019.