Correcting for T1 bias in Magnetization Transfer Saturation (MTsat) Maps Using Sparse-MP2RAGE
Authors:
Christopher D. Rowley,
Mark C. Nelson,
Jennifer S. W. Campbell,
Ilana R. Leppert,
G. Bruce Pike,
Christine L. Tardif
Abstract:
Purpose: Magnetization transfer saturation (MTsat) mapping is commonly used to examine the macromolecular content of brain tissue. This study compared variable flip angle (VFA) T1 mapping against compressed sensing (cs)MP2RAGE T1 mapping for accelerating MTsat imaging. Methods: VFA, MP2RAGE and csMP2RAGE were compared against inversion recovery (IR) T1 in a phantom at 3 Tesla. The same 1 mm VFA, M…
▽ More
Purpose: Magnetization transfer saturation (MTsat) mapping is commonly used to examine the macromolecular content of brain tissue. This study compared variable flip angle (VFA) T1 mapping against compressed sensing (cs)MP2RAGE T1 mapping for accelerating MTsat imaging. Methods: VFA, MP2RAGE and csMP2RAGE were compared against inversion recovery (IR) T1 in a phantom at 3 Tesla. The same 1 mm VFA, MP2RAGE and csMP2RAGE protocols were acquired in four healthy subjects to compare the resulting T1 and MTsat. Bloch-McConnell simulations were used to investigate differences between the phantom and in vivo T1 results. Finally, ten healthy controls were imaged twice with the csMP2RAGE MTsat protocol to quantify repeatability. Results: The MP2RAGE and csMP2RAGE protocols were 13.7% and 32.4% faster than the VFA protocol, respectively. All approaches provided accurate T1 values (<5% difference) in the phantom, but the accuracy of the T1 times was more impacted by differences in T2 for VFA than for MP2RAGE. In vivo, VFA generated longer T1 times than MP2RAGE and csMP2RAGE. Simulations suggest that the bias in the T1 values between VFA and IR-based approaches (MP2RAGE and IR) could be explained by the MT-effects from the inversion pulse. In the test-retest experiment, we found that the csMP2RAGE has a minimum detectable change of 3% for T1 mapping and 7.9% for MTsat imaging. Conclusions: We demonstrated that csMP2RAGE can be used in place of VFA T1 mapping in an MTsat protocol. Furthermore, a shorter scan time and high repeatability can be achieved using the csMP2RAGE sequence.
△ Less
Submitted 13 October, 2023;
originally announced October 2023.
-
Optimization of acquisition parameters for cortical inhomogeneous magnetization transfer (ihMT) imaging using a rapid gradient echo readout
Authors:
Christopher D. Rowley,
Jennifer S. W. Campbell,
Ilana R. Leppert,
Mark C. Nelson,
G. Bruce Pike,
Christine L. Tardif
Abstract:
Purpose: Imaging biomarkers with increased myelin specificity are needed to better understand the complex progression of neurological disorders. Inhomogeneous magnetization transfer (ihMT) imaging is an emergent technique that has a high degree of specificity for myelin content but suffers from low signal-to-noise ratio (SNR). This study used simulations to determine optimal sequence parameters fo…
▽ More
Purpose: Imaging biomarkers with increased myelin specificity are needed to better understand the complex progression of neurological disorders. Inhomogeneous magnetization transfer (ihMT) imaging is an emergent technique that has a high degree of specificity for myelin content but suffers from low signal-to-noise ratio (SNR). This study used simulations to determine optimal sequence parameters for ihMT imaging for use in high-resolution cortical mapping. Methods: MT-weighted cortical image intensity and ihMT SNR were simulated using modified Bloch equations for a range of sequence parameters. The acquisition time was limited to 4.5 min/volume. A custom MT-weighted RAGE sequence with center-out k-space encoding was used to enhance SNR at 3 Tesla. Pulsed MT imaging was studied over a range of saturation parameters and the impact of the turbo-factor on effective ihMT was investigated. 1 mm isotropic ihMTsat maps were generated in 25 healthy adults using an optimized protocol. Results: Greater SNR was observed for larger number of bursts consisting of 6-8 saturation pulses each, combined with a high readout turbo-factor. However, that protocol suffered from a point spread function that was more than twice the nominal resolution. For high-resolution cortical imaging, we selected a protocol with a higher effective resolution at the cost of a lower SNR. We present the first group-average ihMTsat whole-brain map at 1 mm isotropic resolution. Conclusion: This study presents the impact of saturation and excitation parameters on ihMTsat SNR and resolution. We demonstrate the feasibility of high-resolution cortical myelin imaging using ihMTsat in less than 20 minutes.
△ Less
Submitted 9 June, 2023; v1 submitted 14 February, 2023;
originally announced February 2023.
-
Promise and pitfalls of g-ratio estimation with MRI
Authors:
Jennifer S. W. Campbell,
Ilana R. Leppert,
Mathieu Boudreau,
Sridar Narayanan,
Tanguy Duval,
Julien Cohen-Adad,
G. Bruce Pike,
Nikola Stikov
Abstract:
The fiber g-ratio is the ratio of the inner to the outer diameter of the myelin sheath of a myelinated axon. It has a limited dynamic range in healthy white matter, as it is optimized for speed of signal conduction, cellular energetics, and spatial constraints. In vivo imaging of the g-ratio in health and disease would greatly increase our knowledge of the nervous system and our ability to diagnos…
▽ More
The fiber g-ratio is the ratio of the inner to the outer diameter of the myelin sheath of a myelinated axon. It has a limited dynamic range in healthy white matter, as it is optimized for speed of signal conduction, cellular energetics, and spatial constraints. In vivo imaging of the g-ratio in health and disease would greatly increase our knowledge of the nervous system and our ability to diagnose, monitor, and treat disease. MRI based g-ratio imaging was first conceived in 2011, and expanded to be feasible in full brain with preliminary results in 2013. This manuscript reviews the growing g-ratio imaging literature and speculates on future applications. It details the methodology for imaging the g-ratio with MRI, and describes the known pitfalls and challenges in doing so.
△ Less
Submitted 25 August, 2017; v1 submitted 10 January, 2017;
originally announced January 2017.