-
Performance of the MORA Apparatus for Testing Time-Reversal Invariance in Nuclear Beta Decay
Authors:
N. Goyal,
A. Singh,
S. Daumas-Tschopp,
L. M. Motilla Martinez,
G. Ban,
V. Bosquet,
J. F. Cam,
P. Chauveau,
S. Chinthakayala,
G. Fremont,
R. P. De Groote,
F. de Oliveira Santos,
T. Eronen,
A. Falkowski,
X. Flechard,
Z. Ge,
M. Gonzalez-Alonso,
H. Guerin,
L. Hayen,
A. Jaries,
M. Jbayli,
A. Jokinen,
A. Kankainen,
B. Kootte,
R. Kronholm
, et al. (18 additional authors not shown)
Abstract:
The MORA experimental setup is designed to measure the triple-correlation D parameter in nuclear beta decay. The D coefficient is sensitive to possible violations of time-reversal invariance. The experimental configuration consists of a transparent Paul trap surrounded by a detection setup with alternating beta and recoil-ion detectors. The octagonal symmetry of the detection setup optimizes the s…
▽ More
The MORA experimental setup is designed to measure the triple-correlation D parameter in nuclear beta decay. The D coefficient is sensitive to possible violations of time-reversal invariance. The experimental configuration consists of a transparent Paul trap surrounded by a detection setup with alternating beta and recoil-ion detectors. The octagonal symmetry of the detection setup optimizes the sensitivity of positron-recoil-ion coincidence rates to the D correlation, while reducing systematic effects. MORA utilizes an innovative in-trap laser polarization technique. The design and performance of the ion trap, associated beamline elements, lasers and beta and recoil-ion detectors, are presented. Recent progress towards the polarization proof-of-principle is described.
△ Less
Submitted 22 April, 2025;
originally announced April 2025.
-
Realization and simulations of the new SPES Beam Cooler
Authors:
A. Ruzzon,
M. Maggiore,
C. Roncolato,
G. Ban,
J. F. Cam,
C. Gautier,
C. Vandamme
Abstract:
In order to allow a good separation of isotopes in a High Resolution Mass Spectrometer (HRMS), the transverse emittance and the energy spread of the beam should have very low values, for this reason a Beam Cooler (BC) is planned to be located between the ISOL target, i.e. the beam source, and the HRMS in the new project Selective Production of Exotic Species (SPES).
In the SPES project the spect…
▽ More
In order to allow a good separation of isotopes in a High Resolution Mass Spectrometer (HRMS), the transverse emittance and the energy spread of the beam should have very low values, for this reason a Beam Cooler (BC) is planned to be located between the ISOL target, i.e. the beam source, and the HRMS in the new project Selective Production of Exotic Species (SPES).
In the SPES project the spectrometer resolution must be higher than dm/m=5E-5 and thus the features of the beam at the entrance of the HRMS should be at least emittance (95%, normalized) < 8.3E-3 pi mm mrad and sigma_E < 1.5eV.
A new BC has been designed and realized by the Laboratoire de Physique Corpuscolaire (LPC) at Caen, France, for the SPES facility at Laboratori Nazionali di Legnaro (LNL), near Padova, Italy.
BCs cool down the beam thanks to a dissipative process in which the thermal energy passes from the beam ions to another medium whose constituent is typically much lighter, Helium gas in our case. This process takes place inside a confinement system that on the one hand to limit the spread of the cooling medium, and on the other to allow the beam to continue along the required trajectory, in the presented device it is a row of radio frequency quadrupoles in an almost closed chamber.
This document presents the main features of the new BC together with the results of a preliminary study where the beam dynamic has been simulated. The analysis embeds also the investigation of the gas distribution inside and outside the BC.
The beam dynamic simulations are based on the Simion code while the estimation of the gas distribution is computed with MolFlow+.
Simulations show that accurately setting the BC leads to a large improvement of the emittance while the energy spread still needs to be improved. Limiting the gas pressure in the acceleration zone seems to allow the required final boost.
△ Less
Submitted 4 October, 2023;
originally announced October 2023.
-
The spiral1 charge breeder: key points for a performant 1+ beam injection
Authors:
L. Maunoury,
O. Kamalou,
J. F. Cam,
S. Damoy,
P. Delahaye,
M. Dubois,
R. Frigot,
S. Hormigos,
C. Vandamme
Abstract:
The SPIRAL1 charge breeder is now under operation. Radioactive beam has already been delivered [1] to Physicist for performing experiment. Although charge breeding efficiencies demonstrated high performances for stable ion beams, those efficiencies regarding radioactive ion beams were found, in the first experiments, lower than expected. The beam optics, prior to the injection of the 1+ ions into…
▽ More
The SPIRAL1 charge breeder is now under operation. Radioactive beam has already been delivered [1] to Physicist for performing experiment. Although charge breeding efficiencies demonstrated high performances for stable ion beams, those efficiencies regarding radioactive ion beams were found, in the first experiments, lower than expected. The beam optics, prior to the injection of the 1+ ions into the SPIRAL1 charge breeder, is of prime importance [2] for getting such high efficiencies. Moreover, the intensities of the radioactive ion beams are so low, that it is really difficult to tune the charge breeder. The tuning of the charge breeder for radioactive ion beams requires a particular procedure often referred as blind tuning. A stable beam hav-ing a close Brho (few percent) is required to find out the set of optic parameters preceding the tuning of the radioactive beam. Hence, it has been decided to focus our effort on that procedure as to get control of the 1+ beam optics leading to high charge breeding efficiencies whatever the 1+ mass, energy and Target Ion Source System (TISS) used. Being aware that each TISS provide ion beams with a specific energy spread DeltaE, and given that the acceptance energy win-dow of the charge breeder is rather narrow; that parameter must play also an important role in the whole charge breed-ing efficiency.
△ Less
Submitted 17 December, 2020;
originally announced December 2020.
-
Study of SPIRAL 2 High intensity Radiofrequency Cooler: Cooling of very high intensity ion beams
Authors:
Ramzi Boussaid,
G. Ban,
J. F. Cam
Abstract:
The experimental study of Spiral-2 High Intensity Radiofrequency Cooler prototype (SHIRaC) is the goal of this paper.
The experimental study of Spiral-2 High Intensity Radiofrequency Cooler prototype (SHIRaC) is the goal of this paper.
△ Less
Submitted 19 March, 2015; v1 submitted 5 March, 2014;
originally announced March 2014.