$^{28}$Al Half-life Measurement and the negative mirror asymmetry between the $^{28}$Al($β^-$)$^{28m}$Si and $^{28}$P($β^+$)$^{28m}$Si decays
Authors:
B. Liu,
M. Brodeur,
D. W. Bardayan,
F. D. Becchetti,
C. Boomershine,
D. P. Burdette,
L. Caves,
O. Olivas-Gomez,
S. L. Henderson,
J. J. Kolata,
J. Long,
A. D. Nelson,
P. D. O'Malley,
A. Pardo,
R. Zite
Abstract:
In the past, the mirror asymmetry parameter has been proposed as a probing mechanism for the presence of beyond the Standard Model second-class currents in nuclear beta decay transitions. However, this was hindered by large uncertainties in the required nuclear structure correction terms. Recently, a new calculation of these corrections attempted, but could not fully explain the negative mirror as…
▽ More
In the past, the mirror asymmetry parameter has been proposed as a probing mechanism for the presence of beyond the Standard Model second-class currents in nuclear beta decay transitions. However, this was hindered by large uncertainties in the required nuclear structure correction terms. Recently, a new calculation of these corrections attempted, but could not fully explain the negative mirror asymmetry between the $^{28}$Al($β^-$)$^{28m}$Si and $^{28}$P($β^+$)$^{28m}$Si decays. To put the mirror asymmetry parameter on a more solid footing, the half-life of $^{28}$Al was measured for the first time using a radioactive ion beam at the Nuclear Science Laboratory of the University of Notre Dame. The new result, $t_{1/2}=$134.432(34) s, is consistent with most of the past data except for one highly discrepant measurement. The new mirror asymmetry parameter of -3.5(10)$\%$ obtained still does not agree with nuclear structure calculations.
△ Less
Submitted 3 May, 2025;
originally announced May 2025.
-
Obtaining high resolution excitation functions with an active thick-target approach and validating them with mirror nuclei
Authors:
S. Hudan,
J. E. Johnstone,
Rohit Kumar,
R. T. deSouza,
J. Allen,
D. W. Bardayan,
D. Blankstein,
C. Boomershine,
S. Carmichael,
A. Clark,
S. Coil,
S. L. Henderson,
P. D. O'Malley,
W. W. von Seeger
Abstract:
Measurement of fusion excitation functions for stable nuclei has largely been restricted to nuclei with significant natural abundance. Typically, to investigate neighboring nuclei with low natural abundance has required obtaining isotopically enriched material. This restriction often limits the ability to perform such measurements. We report the measurement of a high quality fusion excitation func…
▽ More
Measurement of fusion excitation functions for stable nuclei has largely been restricted to nuclei with significant natural abundance. Typically, to investigate neighboring nuclei with low natural abundance has required obtaining isotopically enriched material. This restriction often limits the ability to perform such measurements. We report the measurement of a high quality fusion excitation function for a $^{17}$O beam produced from unenriched material with 0.038\% natural abundance. The measurement is enabled by using an active thick-target approach and the accuracy of the result is validated using its mirror nucleus $^{17}$F and resonances. The result provides important information about the average fusion cross-section for the oxygen isotopic chain as a function of neutron excess.
△ Less
Submitted 18 April, 2023;
originally announced April 2023.
-
Light Response of Poly(ethylene 2,6-napthalate) to Neutrons
Authors:
Brennan Hackett,
Richard deBoer,
Yuri Efremenko,
Michael Febbraro,
Jason Nattress,
Dan Bardayan,
Chevelle Boomershine,
Kristyn Brandenburg,
Stefania Dede,
Joseph Derkin,
Ruoyu Fang,
Adam Fritsch,
August Gula,
Gyurky Gyorgy,
Gula Hamad,
Yenuel Jones-Alberty,
Beka Kelmar,
Khachatur Manukyan,
Miriam Matney,
John McDonaugh,
Shane Moylan,
Patrick O'Malley,
Shahina Shahina,
Nisha Singh
Abstract:
There is increasing necessity for low background active materials as ton-scale, rare-event and cryogenic detectors are developed. Poly(ethylene-2,6-naphthalate) (PEN) has been considered for these applications because of its robust structural characteristics, and its scintillation light in the blue wavelength region. Radioluminescent properties of PEN have been measured to aid in the evaluation of…
▽ More
There is increasing necessity for low background active materials as ton-scale, rare-event and cryogenic detectors are developed. Poly(ethylene-2,6-naphthalate) (PEN) has been considered for these applications because of its robust structural characteristics, and its scintillation light in the blue wavelength region. Radioluminescent properties of PEN have been measured to aid in the evaluation of this material. In this article we present a measurement of PEN's quenching factor using three different neutron sources; neutrons emitted from spontaneous fission in $^{252}$Cf, neutrons generated from a DD generator, and neutrons emitted from the $^{13}$C($α$,n)$^{16}$O and the $^{7}$Li(p,n)$^{7}$Be nuclear reactions. The fission source used time-of-flight to determine the neutron energy, and the neutron energy from the nuclear reactions was defined using thin targets and reaction kinematics. The Birk's factor and scintillation efficiency were found to be $kB = 0.12 \pm 0.01$ mm MeV$^{-1}$ and $S = 1.31\pm0.09$ MeV$_{ee}$ MeV$^{-1}$ from a simultaneous analysis of the data obtained from the three different sources. With these parameters, it is possible to evaluate PEN as a viable material for large-scale, low background physics experiments.
△ Less
Submitted 21 August, 2024; v1 submitted 6 April, 2022;
originally announced April 2022.
-
MuSIC@Indiana: an effective tool for accurate measurement of fusion with low-intensity radioactive beams
Authors:
J. E. Johnstone,
Rohit Kumar,
S. Hudan,
Varinderjit Singh,
R. T. deSouza,
J. Allen,
D. W. Bardayan,
D. Blankstein,
C. Boomershine,
S. Carmichael,
A. M. Clark,
S. Coil,
S. L. Henderson,
P. D. O'Malley
Abstract:
The design, construction, and characterization of the Multi-Sampling Ionization Chamber, MuSIC@Indiana, are described. This detector provides efficient and accurate measurement of the fusion cross-section at near-barrier energies. The response of the detector to low-intensity beams of $^{17,18}$O, $^{19}$F, $^{23}$Na, $^{24,26}$Mg, $^{27}$Al, and $^{28}$Si at E$_{lab}$ = 50-60 MeV was examined. Mu…
▽ More
The design, construction, and characterization of the Multi-Sampling Ionization Chamber, MuSIC@Indiana, are described. This detector provides efficient and accurate measurement of the fusion cross-section at near-barrier energies. The response of the detector to low-intensity beams of $^{17,18}$O, $^{19}$F, $^{23}$Na, $^{24,26}$Mg, $^{27}$Al, and $^{28}$Si at E$_{lab}$ = 50-60 MeV was examined. MuSIC@Indiana was commissioned by measuring the $^{18}$O+$^{12}$C fusion excitation function for 11 $<$ E$_{cm}$ $<$ 20 MeV using CH$_{4}$ gas. A simple, effective analysis cleanly distinguishes proton capture and two-body scattering events from fusion on carbon. With MuSIC@Indiana, measurement of 15 points on the excitation function for a single incident beam energy is achieved. The resulting excitation function is shown to be in good agreement with literature data
△ Less
Submitted 12 July, 2021;
originally announced July 2021.