-
H2-roaming dynamics in the formation of H3+ following two-photon double ionization of ethanol and aminoethanol
Authors:
Aaron Ngai,
Sebastian Hartweg,
Jakob D. Asmussen,
Björn Bastian,
Matteo Bonanomi,
Carlo Callegari,
Miltcho Danailov,
Michele di Fraia,
Raimund Feifel,
Sarang Dev Ganeshamandiram,
Sivarama Krishnan,
Aaron LaForge,
Friedemann Landmesser,
Ltaief Ben Ltaief,
Moritz Michelbach,
Nitish Pal,
Oksana Plekan,
Nicolas Rendler,
Lorenzo Raimondi,
Fabian Richter,
Audrey Scognamiglio,
Tobias Sixt,
Richard J. Squibb,
Katrin Dulitz,
Frank Stienkemeier
, et al. (1 additional authors not shown)
Abstract:
Roaming reactions involving a neutral fragment of a molecule that transiently wanders around another fragment before forming a new bond are intriguing and peculiar pathways for molecular rearrangement. Such reactions can occur for example upon double ionization of small organic molecules, and have recently sparked much scientific interest. We have studied the dynamics of the H$_2$-roaming reaction…
▽ More
Roaming reactions involving a neutral fragment of a molecule that transiently wanders around another fragment before forming a new bond are intriguing and peculiar pathways for molecular rearrangement. Such reactions can occur for example upon double ionization of small organic molecules, and have recently sparked much scientific interest. We have studied the dynamics of the H$_2$-roaming reaction leading to the formation of H$_3^+$ after two-photon double ionization of ethanol and 2-aminoethanol, using an XUV-UV pump-probe scheme. For ethanol, we find dynamics similar to previous studies employing different pump-probe schemes, indicating the independence of the observed dynamics from the method of ionization and the photon energy of the disruptive probe pulse. Surprisingly, we do not observe a kinetic isotope effect in ethanol-D$_6$, in contrast to previous experiments on methanol where such an effect was observed. This distinction indicates fundamental differences in the energetics of the reaction pathways as compared to the methanol molecule. The larger number of possible roaming pathways compared to methanol complicates the analysis considerably. In contrast to previous studies, we additionally analyze a broad range of dissociative ionization products, which feature distinct dynamics from that of H$_{3}^{+}$ and allow initial insight into the action of the disruptive UV-probe pulse.
△ Less
Submitted 31 March, 2025;
originally announced March 2025.
-
Unraveling the relaxation dynamics of Uracil: insights from time-resolved X-ray photoelectron spectroscopy
Authors:
Davide Faccialà,
Matteo Bonanomi,
Bruno Nunes Cabral Tenorio,
Lorenzo Avaldi,
Paola Bolognesi,
Carlo Callegari,
Marcello Coreno,
Sonia Coriani,
Piero Decleva,
Michele Devetta,
Nađa Došlić,
Alberto De Fanis,
Michele Di Fraia,
Fabiano Lever,
Tommaso Mazza,
Michael Meyer,
Terry Mullins,
Yevheniy Ovcharenko,
Nitish Pal,
Maria Novella Piancastelli,
Robert Richter,
Daniel E. Rivas,
Marin Sapunar,
Björn Senfftleben,
Sergey Usenko
, et al. (4 additional authors not shown)
Abstract:
We report a study of the electronic and nuclear relaxation dynamics of the photoexcited RNA base uracil in the gas phase, using time-resolved core level photoelectron spectroscopy together with high level calculations. The dynamics was investigated by trajectory surface-hopping calculations, and the core ionization energies were calculated for geometries sampled from these. The molecule was excite…
▽ More
We report a study of the electronic and nuclear relaxation dynamics of the photoexcited RNA base uracil in the gas phase, using time-resolved core level photoelectron spectroscopy together with high level calculations. The dynamics was investigated by trajectory surface-hopping calculations, and the core ionization energies were calculated for geometries sampled from these. The molecule was excited by a UV laser and dynamics was probed on the oxygen, nitrogen and carbon site by core electron spectroscopy. Assuming a particular model, we find that the initially excited $S_2(ππ^*)$ state of uracil decays with a time constant of 17 $\pm$ 4 fs to the ground state directly, or to the $S_1(nπ^*)$ state via internal conversion. We find no evidence that the $S_1(nπ^*)$ state decays to the ground state by internal conversion; instead it decays to triplet states with a time constant of 1.6 $\pm$ 0.4 ps. Oscillations of the $S_1(nπ^*)$ state O 1s intensity as a function of time correlate with those of calculated C4=O8 and C5=C6 bond lengths, which undergo a sudden expansion following the initial $π\to π^*$ excitation. We also observe oscillations in the mean energy of the main line (core ionized ionic state), which we tentatively assign to dynamics of the hot ground state. Our calculations support our interpretation of the data, and provide detailed insight into the relaxation processes of uracil.
△ Less
Submitted 24 March, 2025;
originally announced March 2025.
-
Relaxation dynamics in excited helium nanodroplets probed with high resolution, time-resolved photoelectron spectroscopy
Authors:
A. C. LaForge,
J. D. Asmussen,
B. Bastian,
M. Bonanomi,
C. Callegari S. De,
M. Di Fraia,
L. Gorman,
S. Hartweg,
S. R. Krishnan,
M. F. Kling,
D. Mishra,
S. Mandal,
A. Ngai,
N. Pal,
O. Plekan,
K. C. Prince,
P. Rosenberger,
E. Aguirre Serrata,
F. Stienkemeier,
N. Berrah,
M. Mudrich
Abstract:
Superfluid helium nanodroplets are often considered as transparent and chemically inert nanometer-sized cryo-matrices for high-resolution or time-resolved spectroscopy of embedded molecules and clusters. On the other hand, when the helium nanodroplets are resonantly excited with XUV radiation, a multitude of ultrafast processes are initiated, such as relaxation into metastable states, formation of…
▽ More
Superfluid helium nanodroplets are often considered as transparent and chemically inert nanometer-sized cryo-matrices for high-resolution or time-resolved spectroscopy of embedded molecules and clusters. On the other hand, when the helium nanodroplets are resonantly excited with XUV radiation, a multitude of ultrafast processes are initiated, such as relaxation into metastable states, formation of nanoscopic bubbles or excimers, and autoionization channels generating low-energy free electrons. Here, we discuss the full spectrum of ultrafast relaxation processes observed when helium nanodroplets are electronically excited. In particular, we perform an in-depth study of the relaxation dynamics occurring in the lowest 1s2s and 1s2p droplet bands using high resolution, time-resolved photoelectron spectroscopy. The simplified excitation scheme and improved resolution allow us to identify the relaxation into metastable triplet and excimer states even when exciting below the droplets' autoionization threshold, unobserved in previous studies.
△ Less
Submitted 13 March, 2025;
originally announced March 2025.
-
Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20$-$300 GeV/c
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
J. P. Figueiredo de sa Sousa de Almeida,
P. G. Dias de Almeida,
A. Alpana,
M. Alyari,
I. Andreev,
U. Aras,
P. Aspell,
I. O. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
S. Banerjee,
P. DeBarbaro,
P. Bargassa,
D. Barney,
F. Beaudette
, et al. (435 additional authors not shown)
Abstract:
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing med…
▽ More
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly readout by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.
△ Less
Submitted 27 May, 2023; v1 submitted 9 November, 2022;
originally announced November 2022.
-
Applications of Blockchain for the Governance of Integrated Project Delivery: A Crypto Commons Approach
Authors:
Jens J. Hunhevicz,
Pierre-Antoine Brasey,
Marcella M. M. Bonanomi,
Daniel M. Hall,
Martin Fischer
Abstract:
This paper outlines why and how blockchain can digitally support and evolve the governance of collaborative project deliveries, such as integrated project deliveries (IPDs), to provide the foundation for novel and disruptive forms of organizational collaboration in the construction industry. Previous work has conceptualized IPDs as a common pool resource (CPR) scenario, where shared resources are…
▽ More
This paper outlines why and how blockchain can digitally support and evolve the governance of collaborative project deliveries, such as integrated project deliveries (IPDs), to provide the foundation for novel and disruptive forms of organizational collaboration in the construction industry. Previous work has conceptualized IPDs as a common pool resource (CPR) scenario, where shared resources are collectively governed. Through the use of blockchain and smart contracts for trustworthy peer-to-peer transactions and execution logic, Ostrom's design principles can be digitally encoded to scale CPR scenarios. Building on the identified connections, the paper 1) synthesizes fourteen blockchain-based mechanisms to govern CPRs, 2) identifies twenty-two applications of these mechanisms to govern IPDs, and 3) introduces a conceptualization of the above relationships towards a holistic understanding of collaborative project deliveries on the crypto commons for novel collective organization of construction project delivery between both humans and machines.
△ Less
Submitted 14 July, 2022;
originally announced July 2022.
-
Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
F. Alam Khan,
M. Alhusseini,
J. Alison,
A. Alpana,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
P. Aspell,
I. O. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
S. Bannerjee,
P. Bargassa,
D. Barney,
F. Beaudette
, et al. (364 additional authors not shown)
Abstract:
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glu…
▽ More
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1 cm$^2$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.
△ Less
Submitted 31 March, 2022; v1 submitted 12 November, 2021;
originally announced November 2021.
-
A study of muon-electron elastic scattering in a test beam
Authors:
Giovanni Abbiendi,
Giovanni Ballerini,
Dipanwita Banerjee,
Johannes Bernhard,
Matteo Bonanomi,
Claudia Brizzolari,
Luca G. Foggetta,
Mateusz Goncerz,
Fedor V. Ignatov,
Marco Incagli,
Marcin Kucharczyk,
Umberto Marconi,
Valerio Mascagna,
Clara Matteuzzi,
Riccardo Pilato,
Dinko Pocanic,
Michela Prest,
Antonio Principe,
Federico Ronchetti,
Mattia Soldani,
Roberto Tenchini,
Erik Vallazza,
Graziano Venanzoni,
Mariusz Witek,
Milosz Zdybal
Abstract:
In 2018, a test run with muons in the North Area at CERN was performed, running parasitically downstream of the COMPASS spectrometer. The aim of the test was to investigate the elastic interactions of muons on atomic electrons, in an experimental configuration similar to the one proposed by the project MUonE, which plans to perform a very precise measurement of the differential cross-section of th…
▽ More
In 2018, a test run with muons in the North Area at CERN was performed, running parasitically downstream of the COMPASS spectrometer. The aim of the test was to investigate the elastic interactions of muons on atomic electrons, in an experimental configuration similar to the one proposed by the project MUonE, which plans to perform a very precise measurement of the differential cross-section of the elastic interactions. COMPASS was taking data with a 190 GeV pion beam, stopped in a tungsten beam dump: the muons from these pions decays passed through a setup including a graphite target followed by 10 planes of Si tracker and a BGO crystal electromagnetic calorimeter placed at the end of the tracker. The elastic scattering events were analysed, and compared to expectations from MonteCarlo simulation.
△ Less
Submitted 29 April, 2021; v1 submitted 22 February, 2021;
originally announced February 2021.
-
Construction and commissioning of CMS CE prototype silicon modules
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
M. Andrews,
P. Aspell,
I. A. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
P. Bargassa,
D. Barney,
E. Becheva,
P. Behera,
A. Belloni
, et al. (307 additional authors not shown)
Abstract:
As part of its HL-LHC upgrade program, the CMS Collaboration is developing a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modul…
▽ More
As part of its HL-LHC upgrade program, the CMS Collaboration is developing a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modules have been constructed with 6-inch hexagonal silicon sensors with cell areas of 1.1~$cm^2$, and the SKIROC2-CMS readout ASIC. Beam tests of different sampling configurations were conducted with the prototype modules at DESY and CERN in 2017 and 2018. This paper describes the construction and commissioning of the CE calorimeter prototype, the silicon modules used in the construction, their basic performance, and the methods used for their calibration.
△ Less
Submitted 10 December, 2020;
originally announced December 2020.
-
The DAQ system of the 12,000 Channel CMS High Granularity Calorimeter Prototype
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
M. Andrews,
P. Aspell,
I. A. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
P. Bargassa,
D. Barney,
E. Becheva,
P. Behera,
A. Belloni
, et al. (307 additional authors not shown)
Abstract:
The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endca…
▽ More
The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ${\approx}12,000\rm{~channels}$ of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry PI computers.
△ Less
Submitted 8 December, 2020; v1 submitted 7 December, 2020;
originally announced December 2020.
-
Results on Multiple Coulomb Scattering from 12 and 20 GeV electrons on Carbon targets
Authors:
G. Abbiendi,
J. Bernhard,
F. Betti,
M. Bonanomi,
C. M. Carloni Calame,
M. Garattini,
Y. Gavrikov,
G. Hall,
F. Iacoangeli,
F. Ignatov,
M. Incagli,
V. Ivanchenko,
F. Ligabue,
T. O. James,
U. Marconi,
C. Matteuzzi,
M. Passera,
M. Pesaresi,
F. Piccinini,
R. N. Pilato,
F. Pisani,
A. Principe,
W. Scandale,
R. Tenchini,
G. Venanzoni
Abstract:
Multiple scattering effects of 12 and 20 GeV electrons on 8 and 20 mm thickness carbon targets have been studied with high-resolution silicon microstrip detectors of the UA9 apparatus at the H8 line at CERN. Comparison of the scattering angle between data and GEANT4 simulation shows excellent agreement in the core of the distributions leaving some residual disagreement in the tails.
Multiple scattering effects of 12 and 20 GeV electrons on 8 and 20 mm thickness carbon targets have been studied with high-resolution silicon microstrip detectors of the UA9 apparatus at the H8 line at CERN. Comparison of the scattering angle between data and GEANT4 simulation shows excellent agreement in the core of the distributions leaving some residual disagreement in the tails.
△ Less
Submitted 19 April, 2020; v1 submitted 28 May, 2019;
originally announced May 2019.