-
AEgIS Experiment at CERN: Design and Commissioning of SARA (Scintillator Assemblies to Reveal Annihilations)
Authors:
P. Conte,
G. Consolati,
M. Prata,
M. Berghold,
R. Caravita,
R. Ferguson,
M. Grosbart,
F. Guatieri,
S. Haider,
G. Khatri,
L. Lappo,
P. Moskal,
M. Münster,
L. Penasa,
S. Sharma
Abstract:
SARA is the system of plastic scintillators coupled with silicon photomultipliers that will take part in the AEgIS experiment at CERN, measuring the time-of-flight of antihydrogen as it falls through a moiré deflectometer. Its development focused on simplicity, versatility and economy of the design and was supported by both physical tests and finite elements numerical simulations. The instrument's…
▽ More
SARA is the system of plastic scintillators coupled with silicon photomultipliers that will take part in the AEgIS experiment at CERN, measuring the time-of-flight of antihydrogen as it falls through a moiré deflectometer. Its development focused on simplicity, versatility and economy of the design and was supported by both physical tests and finite elements numerical simulations. The instrument's structure pairs the utilization of the scintillators as structural components with custom made 3D printed corner elements and the electronics allows to select between coincidence discrimination made on each scintillator and made between different scintillators.
△ Less
Submitted 10 June, 2025;
originally announced June 2025.
-
Real-time antiproton annihilation vertexing with sub-micron resolution
Authors:
M. Berghold,
D. Orsucci,
F. Guatieri,
S. Alfaro,
M. Auzins,
B. Bergmann,
P. Burian,
R. S. Brusa,
A. Camper,
R. Caravita,
F. Castelli,
G. Cerchiari,
R. Ciuryło,
A. Chehaimi,
G. Consolati,
M. Doser,
K. Eliaszuk,
R. Ferguson,
M. Germann,
A. Giszczak,
L. T. Glöggler,
Ł. Graczykowski,
M. Grosbart,
F. Guatieri,
N. Gusakova
, et al. (42 additional authors not shown)
Abstract:
The primary goal of the AEgIS experiment is to precisely measure the free fall of antihydrogen within Earth's gravitational field. To this end, a cold ~50K antihydrogen beam has to pass through two grids forming a moiré deflectometer before annihilating onto a position-sensitive detector, which shall determine the vertical position of the annihilation vertex relative to the grids with micrometric…
▽ More
The primary goal of the AEgIS experiment is to precisely measure the free fall of antihydrogen within Earth's gravitational field. To this end, a cold ~50K antihydrogen beam has to pass through two grids forming a moiré deflectometer before annihilating onto a position-sensitive detector, which shall determine the vertical position of the annihilation vertex relative to the grids with micrometric accuracy. Here we introduce a vertexing detector based on a modified mobile camera sensor and experimentally demonstrate that it can measure the position of antiproton annihilations with an accuracy of $0.62^{+0.40}_{-0.22}μm$, which represents a 35-fold improvement over the previous state-of-the-art for real-time antiproton vertexing. Importantly, these antiproton detection methods are directly applicable to antihydrogen. Moreover, the sensitivity to light of the sensor enables the in-situ calibration of the moiré deflectometer, significantly reducing systematic errors. This sensor emerges as a breakthrough technology for achieving the \aegis scientific goals and has been selected as the basis for the development of a large-area detector for conducting antihydrogen gravity measurements.
△ Less
Submitted 23 June, 2024;
originally announced June 2024.
-
Imaging low-energy positron beams in real-time with unprecedented resolution
Authors:
Michael Berghold,
Vassily Vadimovitch Burwitz,
Lucian Mathes,
Christoph Pascal Hugenschmidt,
Francesco Guatieri
Abstract:
Particle beams focused to micrometer-sized spots play a crucial role in forefront research using low-energy positrons. Their expedient and wide application, however, requires highly-resolved, fast beam diagnostics. We have developed two different methods to modify a commercial imaging sensor to make it sensitive to low-energy positrons. The first method consists in removing the micro-lens array an…
▽ More
Particle beams focused to micrometer-sized spots play a crucial role in forefront research using low-energy positrons. Their expedient and wide application, however, requires highly-resolved, fast beam diagnostics. We have developed two different methods to modify a commercial imaging sensor to make it sensitive to low-energy positrons. The first method consists in removing the micro-lens array and Bayer filter from the sensor surface and depositing a phosphor layer in their place. This procedure results in a detector capable of imaging positron beams with energies down to a few tens of eV, or an intensity as low as 35 particles/s/mm2 when the beam energy exceeds 10keV. The second approach omits the phosphor deposition; with the resulting device we succeeded in detecting single positrons with energies upwards of 6 keV and efficiency up to 93%. The achieved spatial resolution of 0.97 micrometers is unprecedented for real-time positron detectors.
△ Less
Submitted 6 June, 2023;
originally announced June 2023.