-
Lung Cancer Lesion Detection in Histopathology Images Using Graph-Based Sparse PCA Network
Authors:
Sundaresh Ram,
Wenfei Tang,
Alexander J. Bell,
Cara Spencer,
Alexander Buschhaus,
Charles R. Hatt,
Marina Pasca diMagliano,
Jeffrey J. Rodriguez,
Stefanie Galban,
Craig J. Galban
Abstract:
Early detection of lung cancer is critical for improvement of patient survival. To address the clinical need for efficacious treatments, genetically engineered mouse models (GEMM) have become integral in identifying and evaluating the molecular underpinnings of this complex disease that may be exploited as therapeutic targets. Assessment of GEMM tumor burden on histopathological sections performed…
▽ More
Early detection of lung cancer is critical for improvement of patient survival. To address the clinical need for efficacious treatments, genetically engineered mouse models (GEMM) have become integral in identifying and evaluating the molecular underpinnings of this complex disease that may be exploited as therapeutic targets. Assessment of GEMM tumor burden on histopathological sections performed by manual inspection is both time consuming and prone to subjective bias. Therefore, an interplay of needs and challenges exists for computer-aided diagnostic tools, for accurate and efficient analysis of these histopathology images. In this paper, we propose a simple machine learning approach called the graph-based sparse principal component analysis (GS-PCA) network, for automated detection of cancerous lesions on histological lung slides stained by hematoxylin and eosin (H&E). Our method comprises four steps: 1) cascaded graph-based sparse PCA, 2) PCA binary hashing, 3) block-wise histograms, and 4) support vector machine (SVM) classification. In our proposed architecture, graph-based sparse PCA is employed to learn the filter banks of the multiple stages of a convolutional network. This is followed by PCA hashing and block histograms for indexing and pooling. The meaningful features extracted from this GS-PCA are then fed to an SVM classifier. We evaluate the performance of the proposed algorithm on H&E slides obtained from an inducible K-rasG12D lung cancer mouse model using precision/recall rates, F-score, Tanimoto coefficient, and area under the curve (AUC) of the receiver operator characteristic (ROC) and show that our algorithm is efficient and provides improved detection accuracy compared to existing algorithms.
△ Less
Submitted 15 February, 2022; v1 submitted 27 October, 2021;
originally announced October 2021.
-
Macroscopic polarization in the nominally ergodic relaxor state of lead magnesium niobate
Authors:
Lukas M. Riemer,
Kanghyun Chu,
Yang Li,
Hana Ursic,
Andrew J. Bell,
Brahim Dkhil,
Dragan Damjanovic
Abstract:
Macroscopic polarity and its dynamic response to external electric fields and temperature in the nominally ergodic relaxor phase of pristine lead magnesium niobate crystals and ceramics, Pb(Mg1/3Nb2/3)O3 (PMN), were investigated. Dynamic pyroelectric measurements provide evidence for persistent macroscopic polarity of the samples. Annealing experiments below and above Burns temperature of polarize…
▽ More
Macroscopic polarity and its dynamic response to external electric fields and temperature in the nominally ergodic relaxor phase of pristine lead magnesium niobate crystals and ceramics, Pb(Mg1/3Nb2/3)O3 (PMN), were investigated. Dynamic pyroelectric measurements provide evidence for persistent macroscopic polarity of the samples. Annealing experiments below and above Burns temperature of polarized samples relate this polarity to the presence of polar nano entities and their dynamics. The dc electric field strength required for macroscopic polarization reversal is similar to the amplitude of the ac field where dynamic nonlinear dielectric permittivity reaches maximum. Consequently, the aforementioned maximum is related to the reorientation of polar nano entities. The results question the existence of an ergodic state in PMN below Burns temperature.
△ Less
Submitted 5 November, 2020;
originally announced November 2020.
-
Dielectric properties of relaxor-ferroelectric ceramic and single crystal Pb(In$_{1/2}$Nb$_{1/2}$)O$_{3}$-Pb(Mg$_{1/3}$Nb$_{2/3}$)O$_{3}$-PbTiO$_{3}$ at cryogenic temperatures
Authors:
Philippa M. Shepley,
Laura A. Stoica,
Yang Li,
Gavin Burnell,
Andrew J. Bell
Abstract:
We investigate the low temperature behaviour of Pb(In$_{1/2}$Nb$_{1/2}$)O$_{3}$-Pb(Mg$_{1/3}$Nb$_{2/3}$)O$_{3}$-PbTiO$_{3}$ using dielectric permittivity measurements. We compare single crystal plates measured in the [001] and [111] directions with a polycrystalline ceramic of the same composition. Poled crystals behave very differently to unpoled crystals, whereas the dielectric spectrum of the c…
▽ More
We investigate the low temperature behaviour of Pb(In$_{1/2}$Nb$_{1/2}$)O$_{3}$-Pb(Mg$_{1/3}$Nb$_{2/3}$)O$_{3}$-PbTiO$_{3}$ using dielectric permittivity measurements. We compare single crystal plates measured in the [001] and [111] directions with a polycrystalline ceramic of the same composition. Poled crystals behave very differently to unpoled crystals, whereas the dielectric spectrum of the ceramic changes very little on poling. A large, frequency dependent dielectric relaxation seen in the poled [001] crystal around 100 K is much less prominent in the [111] crystal, and doesn't occur in the ceramic. Preparation conditions and the microstructure of the material play a role in the low temperature dynamics of relaxor-ferroelectric crystals.
△ Less
Submitted 16 February, 2018;
originally announced February 2018.
-
Multiferroic clusters: a new perspective for relaxor-type room-temperature multiferroics
Authors:
Leonard F. Henrichs,
Oscar Cespedes,
James Bennett,
Joachim Landers,
Soma Salamon,
Christian Heuser,
Tim Helbig,
Oliver Gutfleisch,
Doru C. Lupascu,
Heiko Wende,
Wolfgang Kleemann,
Andrew J. Bell
Abstract:
Multiferroics are promising for sensor and memory applications, but despite all efforts invested in their research no single-phase material displaying both ferroelectricity and large magnetization at room-temperature has hitherto been reported. This situation has substantially been improved in the novel relaxor ferroelectric single-phase , where polar nanoregions (PNR) transform into static-PNR (S…
▽ More
Multiferroics are promising for sensor and memory applications, but despite all efforts invested in their research no single-phase material displaying both ferroelectricity and large magnetization at room-temperature has hitherto been reported. This situation has substantially been improved in the novel relaxor ferroelectric single-phase , where polar nanoregions (PNR) transform into static-PNR (SPNR) as evidenced by piezoresponse force microscopy (PFM) and simultaneously enable congruent multiferroic clusters (MFC) to emerge from inherent ferrimagnetic Bi(Fe,Co)O3 regions as verified by magnetic force microscopy (MFM) and secondary ion mass spectrometry (SIMS). On these MFC, exceptionally large direct and converse magnetoelectric coupling coefficients, at room-temperature, were measured by PFM and MFM respectively. We expect the non-ergodic relaxor properties which are governed by the Bi0.5K0.5TiO3 component to play a vital role in the strong ME coupling, by providing an electrically and mechanically flexible environment to MFC. This new class of non-ergodic relaxor multiferroics bears great potential for applications. Especially the prospect of a ME nanodot storage device seems appealing.
△ Less
Submitted 26 February, 2016;
originally announced February 2016.
-
Choice of tip, signal stability and practical aspects of Piezoresponse-Force-Microscopy
Authors:
L. F. Henrichs,
J. Bennett,
A. J. Bell
Abstract:
Piezoresponse force-microscopy (PFM) has become the standard tool to investigate ferroelectrics on the micro- and nanoscale. However, reliability of PFM signals is often problematic and their quantification is challenging and thus not widely applied. Here, we present a study of the reproducibility of PFM signals and of the so-called PFM background signal which has been reported in literature. We f…
▽ More
Piezoresponse force-microscopy (PFM) has become the standard tool to investigate ferroelectrics on the micro- and nanoscale. However, reliability of PFM signals is often problematic and their quantification is challenging and thus not widely applied. Here, we present a study of the reproducibility of PFM signals and of the so-called PFM background signal which has been reported in literature. We find that PFM signals are generally reproducible to certain extents. The PFM signal difference between 180° domains on periodically-poled lithium niobate (PPLN) is taken as the reference signal in a large number of measurements, carried out in a low frequency regime (30-70 kHz). We show that in comparison to Pt coated tips, diamond coated tips exhibit improved signal stability, lower background signal and less imaging artifacts related to PFM which is reflected in the spread of measurements. This is attributed to the improved mechanical stability of the conductive layer. The average deviation of the mean PFM signal is 38.3%, for a diamond coated tip. Although this deviation is relatively high, it is far better than values from literature which showed a deviation of approx. 73.1%. Additionally, we find that the average deviation of the background signal from 0 is 11.6% of the PPLN domain contrast. Thus, the background signal needs to be taken into account when quantifying PFM signals and should be subtracted from PFM signals. Those results are important for quantification of PFM signals, since PPLN might be used for this purpose when PFM signals measured on PPLN are related to its macroscopic d33 coefficient. Finally, the crucial influence of sample polishing on PFM signals is shown and we recommend to use a multistep polishing route with a final step involving 200 nm sized colloidal silica particles.
△ Less
Submitted 14 January, 2016;
originally announced January 2016.
-
MD Simulation for Head-on Collision of Liquid Nanodroplets Obeying Modified L-J Potential
Authors:
Alexander J. Bell
Abstract:
This project models and studies the `head-on' collision of liquid helium nanodroplets within a vacuum, using molecular dynamics simulation techniques. Programs written in MATLAB and C are utilized in tandem to facilitate computer experimentation that achieves this goal. The most expensive computation, that of collision simulation, is handled by a HPC cluster `ALICE' at the University of Leicester.…
▽ More
This project models and studies the `head-on' collision of liquid helium nanodroplets within a vacuum, using molecular dynamics simulation techniques. Programs written in MATLAB and C are utilized in tandem to facilitate computer experimentation that achieves this goal. The most expensive computation, that of collision simulation, is handled by a HPC cluster `ALICE' at the University of Leicester.
Colliding droplets are modelled as roughly spherical collections of points, cut from a simple cubic lattice, obeying a modified Lennard-Jones potential, with average velocities initialized to ensure a `head-on' collision. These point-sets are then allowed to collide within a cuboid region, designed to take advantage of the observed angular distribution of post-collision fragmentation (favoring a plane orthogonal to `collision axis').
To implement the developed theoretical model, an existing C script by D. C. Rapaport, for modelling a homogeneous liquid state, is edited by the author to fit the given, highly heterogeneous scenario. To do analysis on the resulting positions and velocities of points in time, a precise definition of `droplet' was required. An object is defined, from the perspective of metric space, to satisfy this need. An existing cluster analysis algorithm, DBSCAN, is used to apply this definition to the points in simulation.
The results presented here focus on three distinct properties of post-collision droplets, these being size, speed and temperature; for collision speed varying across ten equidistant averages chosen based on visual examination of collisions. Quantitative evidence of post-collision droplet speed being inversely proportional to droplet radius is presented, droplet temperature distribution post-collision is noted, and qualitative change in collision behavior across a certain threshold of collision speed is observed.
△ Less
Submitted 4 July, 2015;
originally announced July 2015.
-
Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data
Authors:
The CMS,
LHCb Collaborations,
:,
V. Khachatryan,
A. M. Sirunyan,
A. Tumasyan,
W. Adam,
T. Bergauer,
M. Dragicevic,
J. Erö,
M. Friedl,
R. Frühwirth,
V. M. Ghete,
C. Hartl,
N. Hörmann,
J. Hrubec,
M. Jeitler,
W. Kiesenhofer,
V. Knünz,
M. Krammer,
I. Krätschmer,
D. Liko,
I. Mikulec,
D. Rabady,
B. Rahbaran
, et al. (2807 additional authors not shown)
Abstract:
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six sta…
▽ More
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six standard deviations, and the best measurement of its branching fraction so far. Furthermore, evidence for the $B^0\toμ^+μ^-$ decay is obtained with a statistical significance of three standard deviations. The branching fraction measurements are statistically compatible with SM predictions and impose stringent constraints on several theories beyond the SM.
△ Less
Submitted 17 August, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.
-
The thermodynamics of prediction
Authors:
Susanne Still,
David A. Sivak,
Anthony J. Bell,
Gavin E. Crooks
Abstract:
A system responding to a stochastic driving signal can be interpreted as computing, by means of its dynamics, an implicit model of the environmental variables. The system's state retains information about past environmental fluctuations, and a fraction of this information is predictive of future ones. The remaining nonpredictive information reflects model complexity that does not improve predictiv…
▽ More
A system responding to a stochastic driving signal can be interpreted as computing, by means of its dynamics, an implicit model of the environmental variables. The system's state retains information about past environmental fluctuations, and a fraction of this information is predictive of future ones. The remaining nonpredictive information reflects model complexity that does not improve predictive power, and thus represents the ineffectiveness of the model. We expose the fundamental equivalence between this model inefficiency and thermodynamic inefficiency, measured by dissipation. Our results hold arbitrarily far from thermodynamic equilibrium and are applicable to a wide range of systems, including biomolecular machines. They highlight a profound connection between the effective use of information and efficient thermodynamic operation: any system constructed to keep memory about its environment and to operate with maximal energetic efficiency has to be predictive.
△ Less
Submitted 5 October, 2012; v1 submitted 15 March, 2012;
originally announced March 2012.
-
Performance of the Fast Beam Conditions Monitor BCM1F of CMS in the first running periods of LHC
Authors:
R. S. Schmidt,
A. J. Bell,
E. Castro,
R. Hall-Wilton,
M. Hempel,
W. Lange,
W. Lohmann,
S. Müller,
V. Ryjov,
D. Stickland,
R. Walsh
Abstract:
The Beam Conditions and Radiation Monitoring System, BRM, is implemented in CMS to protect the detector and provide an interface to the LHC. Seven sub-systems monitor beam conditions and the radiation level inside the detector on different time scales. They detect adverse beam conditions, facilitate beam tuning close to CMS, and measure the doses accumulated in different detector components. Data…
▽ More
The Beam Conditions and Radiation Monitoring System, BRM, is implemented in CMS to protect the detector and provide an interface to the LHC. Seven sub-systems monitor beam conditions and the radiation level inside the detector on different time scales. They detect adverse beam conditions, facilitate beam tuning close to CMS, and measure the doses accumulated in different detector components. Data are taken and analysed independently of the CMS data acquisition, displayed in the control room, and provide inputs to the trigger system and the LHC operators. In case of beam conditions dangerous to the CMS detector, a beam abort is induced.
The Fast Beam Conditions Monitor, BCM1F, is a flux counter close to the beam pipe inside the tracker volume. It uses single-crystal CVD diamond sensors, radiation-hard FE electronics, and optical signal transmission to measure the beam halo as well as collision products bunch by bunch. The system has been operational during the initiatory runs of LHC in September 2008. It works reliably since the restart in 2009 and is invaluable to CMS for everyday LHC operation. A characterisation of the system on the basis of data collected during LHC operation is presented.
△ Less
Submitted 16 December, 2010;
originally announced December 2010.
-
Critical mass in nonzero temperature QCD with staggered fermions
Authors:
I. M. Barbour,
A. J. Bell,
E. G. Klepfish
Abstract:
The behaviour of the chiral condensate in QCD is investigated by means of a study of the distribution of the zeros of the partition function in the complex quark mass plane. Simulations are performed at fixed temperature on three different spatial volumes at $β=5.04$ and at $β=4.9$ and $β=5.2$ on a $4^4$ lattice. Evidence is found for a chirally related transition at non-zero quark mass in the i…
▽ More
The behaviour of the chiral condensate in QCD is investigated by means of a study of the distribution of the zeros of the partition function in the complex quark mass plane. Simulations are performed at fixed temperature on three different spatial volumes at $β=5.04$ and at $β=4.9$ and $β=5.2$ on a $4^4$ lattice. Evidence is found for a chirally related transition at non-zero quark mass in the intermediate coupling region for $β< 5.2 $ but superimposed upon a smooth behaviour for the condensate. The critical mass at which this transition is found is only weakly dependent on the spatial volume and decreas with decreasing temperature.
△ Less
Submitted 23 May, 1992;
originally announced May 1992.