Skip to main content

Showing 1–30 of 30 results for author: Behnke, E

.
  1. arXiv:2504.13089  [pdf, other

    hep-ex hep-ph

    Absorption of Fermionic Dark Matter in the PICO-60 C$_{3}$F$_{8}$ Bubble Chamber

    Authors: E. Adams, B. Ali, R. Anderson-Dornan, I. J. Arnquist, M. Bai, D. Baxter, E. Behnke, B. Broerman, C. J. Chen, K. Clark, J. I. Collar, P. S. Cooper, D. Cranshaw, C. Cripe, M. Crisler, C. E. Dahl, M. Das, S. Das, S. Fallows, J. Farine, R. Filgas, A. García-Viltres, G. Giroux, O. Harris, H. Hawley-Herrera , et al. (36 additional authors not shown)

    Abstract: Fermionic dark matter absorption on nuclear targets via neutral current interactions is explored using a non-relativistic effective field theory framework. An analysis of data from the PICO-60 C$_{3}$F$_{8}$ bubble chamber sets leading constraints on spin-independent absorption for dark matter masses below 23 MeV/$\textit{c}^2$ and establishes the first limits on spin-dependent absorptive interact… ▽ More

    Submitted 17 April, 2025; originally announced April 2025.

  2. arXiv:2410.07241  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Low-threshold response of a scintillating xenon bubble chamber to nuclear and electronic recoils

    Authors: E. Alfonso-Pita, E. Behnke, M. Bressler, B. Broerman, K. Clark, R. Coppejans, J. Corbett, M. Crisler, C. E. Dahl, K. Dering, A. de St. Croix, D. Durnford, P. Giampa, J. Hall, O. Harris, H. Hawley-Herrera, N. Lamb, M. Laurin, I. Levine, W. H. Lippincott, R. Neilson, M. -C. Piro, D. Pyda, Z. Sheng, G. Sweeney , et al. (7 additional authors not shown)

    Abstract: A device filled with pure xenon first demonstrated the ability to operate simultaneously as a bubble chamber and scintillation detector in 2017. Initial results from data taken at thermodynamic thresholds down to ~4 keV showed sensitivity to ~20 keV nuclear recoils with no observable bubble nucleation by $γ$-ray interactions. This paper presents results from further operation of the same device at… ▽ More

    Submitted 12 February, 2025; v1 submitted 7 October, 2024; originally announced October 2024.

    Comments: 11 pages, 7 figures

    Journal ref: Phys. Rev. D 111, 032002 (2025)

  3. Batch VUV4 Characterization for the SBC-LAr10 scintillating bubble chamber

    Authors: H. Hawley-Herrera, E. Alfonso-Pita, E. Behnke, M. Bressler, B. Broerman, K. Clark, J. Corbett, C. E. Dahl, K. Dering, A. de St. Croix, D. Durnford, P. Giampa, J. Hall, O. Harris, N. Lamb, M. Laurin, I. Levine, W. H. Lippincott, X. Liu, N. Moss, R. Neilson, M. -C. Piro, D. Pyda, Z. Sheng, G. Sweeney , et al. (6 additional authors not shown)

    Abstract: The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10~kg of liquid argon. A dark-count characterization technique, which avoids the use of a single-photon source, was used at two temperatures to measure the VUV4 SiPMs breakdown voltage ($V_{\text{BD}}$), the SiPM gain (… ▽ More

    Submitted 22 July, 2024; v1 submitted 28 May, 2024; originally announced May 2024.

    Comments: 25 pages, 19 figures

    Report number: FERMILAB-PUB-24-0280-LDRD-PPD

  4. arXiv:2301.08993  [pdf, other

    astro-ph.CO hep-ex hep-ph

    Search for inelastic dark matter-nucleus scattering with the PICO-60 CF$_{3}$I and C$_{3}$F$_{8}$ bubble chambers

    Authors: E. Adams, B. Ali, I. J. Arnquist, D. Baxter, E. Behnke, M. Bressler, B. Broerman, C. J. Chen, K. Clark, J. I. Collar, P. S. Cooper, C. Cripe, M. Crisler, C. E. Dahl, M. Das, S. Fallows, J. Farine, R. Filgas, A. García Viltres, G. Giroux, O. Harris, T. Hillier, E. W. Hoppe, C. M. Jackson, M. Jin , et al. (30 additional authors not shown)

    Abstract: PICO bubble chambers have exceptional sensitivity to inelastic dark matter-nucleus interactions due to a combination of their extended nuclear recoil energy detection window from a few keV to $O$(100 keV) or more and the use of iodine as a heavy target. Inelastic dark matter-nucleus scattering is interesting for studying the properties of dark matter, where many theoretical scenarios have been dev… ▽ More

    Submitted 21 January, 2023; originally announced January 2023.

    Comments: 7 pages, 3 figures

  5. arXiv:2207.12400  [pdf, other

    physics.ins-det astro-ph.IM hep-ex nucl-ex

    Snowmass 2021 Scintillating Bubble Chambers: Liquid-noble Bubble Chambers for Dark Matter and CE$ν$NS Detection

    Authors: E. Alfonso-Pita, M. Baker, E. Behnke, A. Brandon, M. Bressler, B. Broerman, K. Clark, R. Coppejans, J. Corbett, C. Cripe, M. Crisler, C. E. Dahl, K. Dering, A. de St. Croix, D. Durnford, K. Foy, P. Giampa, J. Gresl, J. Hall, O. Harris, H. Hawley-Herrera, C. M. Jackson, M. Khatri, Y. Ko, N. Lamb , et al. (20 additional authors not shown)

    Abstract: The Scintillating Bubble Chamber (SBC) Collaboration is developing liquid-noble bubble chambers for the quasi-background-free detection of low-mass (GeV-scale) dark matter and coherent scattering of low-energy (MeV-scale) neutrinos (CE$ν$NS). The first physics-scale demonstrator of this technique, a 10-kg liquid argon bubble chamber dubbed SBC-LAr10, is now being commissioned at Fermilab. This dev… ▽ More

    Submitted 29 September, 2022; v1 submitted 21 July, 2022; originally announced July 2022.

    Comments: 35 pages, 12 figures, contributed white paper to Snowmass 2021 (final version for Snowmass proceedings)

    Report number: FERMILAB-CONF-22-535-LDRD-PPD

  6. arXiv:2205.05771  [pdf, other

    physics.ins-det astro-ph.IM

    Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C$_3$F$_8$ dark matter detectors

    Authors: B. Ali, I. J. Arnquist, D. Baxter, E. Behnke, M. Bressler, B. Broerman, K. Clark, J. I. Collar, P. S. Cooper, C. Cripe, M. Crisler, C. E. Dahl, M. Das, D. Durnford, S. Fallows, J. Farine, R. Filgas, A. García-Viltres, F. Girard, G. Giroux, O. Harris, E. W. Hoppe, C. M. Jackson, M. Jin, C. B. Krauss , et al. (32 additional authors not shown)

    Abstract: The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct… ▽ More

    Submitted 7 November, 2022; v1 submitted 11 May, 2022; originally announced May 2022.

    Comments: 17 pages, 22 figures, 5 tables

    Journal ref: Phys. Rev. D 106, 122003 (2022)

  7. arXiv:2204.10340  [pdf, other

    astro-ph.CO hep-ex hep-ph

    Results on photon-mediated dark matter-nucleus interactions from the PICO-60 C$_{3}$F$_{8}$ bubble chamber

    Authors: B. Ali, I. J. Arnquist, D. Baxter, E. Behnke, M. Bressler, B. Broerman, C. J. Chen, K. Clark, J. I. Collar, P. S. Cooper, C. Cripe, M. Crisler, C. E. Dahl, M. Das, D. Durnford, S. Fallows, J. Farine, R. Filgas, A. García-Viltres, G. Giroux, O. Harris, T. Hillier, E. W. Hoppe, C. M. Jackson, M. Jin , et al. (30 additional authors not shown)

    Abstract: Many compelling models predict dark matter coupling to the electromagnetic current through higher multipole interactions, while remaining electrically neutral. Different multipole couplings have been studied, among them anapole moment, electric and magnetic dipole moments, and millicharge. This study sets limits on the couplings for these photon-mediated interactions using non-relativistic contact… ▽ More

    Submitted 21 April, 2022; originally announced April 2022.

  8. arXiv:2101.08785  [pdf, other

    hep-ex hep-ph nucl-ex physics.ins-det

    Physics reach of a low threshold scintillating argon bubble chamber in coherent elastic neutrino-nucleus scattering reactor experiments

    Authors: L. J. Flores, Eduardo Peinado, E. Alfonso-Pita, K. Allen, M. Baker, E. Behnke, M. Bressler, K. Clark, R. Coppejans, C. Cripe, M. Crisler, C. E. Dahl, A. de St. Croix, D. Durnford, P. Giampa, O. Harris, P. Hatch, H. Hawley, C. M. Jackson, Y. Ko, C. Krauss, N. Lamb, M. Laurin, I. Levine, W. H. Lippincott , et al. (9 additional authors not shown)

    Abstract: The physics reach of a low threshold (100 eV) scintillating argon bubble chamber sensitive to Coherent Elastic neutrino-Nucleus Scattering (CE$ν$NS) from reactor neutrinos is studied. The sensitivity to the weak mixing angle, neutrino magnetic moment, and a light $Z'$ gauge boson mediator are analyzed. A Monte Carlo simulation of the backgrounds is performed to assess their contribution to the sig… ▽ More

    Submitted 26 May, 2021; v1 submitted 21 January, 2021; originally announced January 2021.

    Comments: 9 pages, 5 figures. v2: figures added, minor changes. Matches published version

    Journal ref: Phys. Rev. D 103, 091301 (2021)

  9. Velocity independent constraints on spin-dependent DM-nucleon interactions from IceCube and PICO

    Authors: IceCube Collaboration, M. G. Aartsen, M. Ackermann, J. Adams, J. A. Aguilar, M. Ahlers, M. Ahrens, C. Alispach, K. Andeen, T. Anderson, I. Ansseau, G. Anton, C. Argüelles, J. Auffenberg, S. Axani, P. Backes, H. Bagherpour, X. Bai, A. Balagopal V., A. Barbano, S. W. Barwick, B. Bastian, V. Baum, S. Baur, R. Bay , et al. (398 additional authors not shown)

    Abstract: Adopting the Standard Halo Model (SHM) of an isotropic Maxwellian velocity distribution for dark matter (DM) particles in the Galaxy, the most stringent current constraints on their spin-dependent scattering cross-section with nucleons come from the IceCube neutrino observatory and the PICO-60 C$_3$F$_8$ superheated bubble chamber experiments. The former is sensitive to high energy neutrinos from… ▽ More

    Submitted 25 May, 2020; v1 submitted 29 July, 2019; originally announced July 2019.

    Comments: 9 pages, 3 figures, 1 table. To appear in Eur.Phys.J. C

    Journal ref: Eur. Phys. J. C 80 (2020) 819

  10. arXiv:1905.12522  [pdf, ps, other

    physics.ins-det astro-ph.CO hep-ex hep-ph

    Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$ Bubble Chambers

    Authors: C. Amole, M. Ardid, I. J. Arnquist, D. M. Asner, D. Baxter, E. Behnke, M. Bressler, B. Broerman, G. Cao, C. J. Chen, S. Chen, U. Chowdhury, K. Clark, J. I. Collar, P. S. Cooper, C. B. Coutu, C. Cowles, M. Crisler, G. Crowder, N. A. Cruz-Venegas, C. E. Dahl, M. Das, S. Fallows, J. Farine, R. Filgas , et al. (54 additional authors not shown)

    Abstract: The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by… ▽ More

    Submitted 25 November, 2020; v1 submitted 29 May, 2019; originally announced May 2019.

    Comments: 18 pages, 12 figures

    Journal ref: Phys. Rev. D 100, 082006 (2019)

  11. arXiv:1902.04031  [pdf, other

    astro-ph.CO hep-ex physics.ins-det

    Dark Matter Search Results from the Complete Exposure of the PICO-60 C$_3$F$_8$ Bubble Chamber

    Authors: C. Amole, M. Ardid, I. J. Arnquist, D. M. Asner, D. Baxter, E. Behnke, M. Bressler, B. Broerman, G. Cao, C. J. Chen, U. Chowdhury, K. Clark, J. I. Collar, P. S. Cooper, C. B. Coutu, C. Cowles, M. Crisler, G. Crowder, N. A. Cruz-Venegas, C. E. Dahl, M. Das, S. Fallows, J. Farine, I. Felis, R. Filgas , et al. (47 additional authors not shown)

    Abstract: Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total backgr… ▽ More

    Submitted 11 February, 2019; originally announced February 2019.

    Comments: 9 pages, 8 figures

    Journal ref: Phys. Rev. D 100, 022001 (2019)

  12. arXiv:1811.11308  [pdf, other

    physics.comp-ph physics.ins-det

    Developing a Bubble Chamber Particle Discriminator Using Semi-Supervised Learning

    Authors: B. Matusch, C. Amole, M. Ardid, I. J. Arnquist, D. M. Asner, D. Baxter, E. Behnke, M. Bressler, B. Broerman, G. Cao, C. J. Chen, U. Chowdhury, K. Clark, J. I. Collar, P. S. Cooper, C. B. Coutu, C. Cowles, M. Crisler, G. Crowder, N. A. Cruz-Venegas, C. E. Dahl, M. Das, S. Fallows, J. Farine, I. Felis , et al. (48 additional authors not shown)

    Abstract: The identification of non-signal events is a major hurdle to overcome for bubble chamber dark matter experiments such as PICO-60. The current practice of manually developing a discriminator function to eliminate background events is difficult when available calibration data is frequently impure and present only in small quantities. In this study, several different discriminator input/preprocessing… ▽ More

    Submitted 27 November, 2018; originally announced November 2018.

    Comments: 27 pages, 10 figures

  13. arXiv:1702.07666  [pdf, ps, other

    astro-ph.CO hep-ex physics.ins-det

    Dark Matter Search Results from the PICO-60 C$_3$F$_8$ Bubble Chamber

    Authors: C. Amole, M. Ardid, I. J. Arnquist, D. M. Asner, D. Baxter, E. Behnke, P. Bhattacharjee, H. Borsodi, M. Bou-Cabo, P. Campion, G. Cao, C. J. Chen, U. Chowdhury, K. Clark, J. I. Collar, P. S. Cooper, M. Crisler, G. Crowder, C. E. Dahl, M. Das, S. Fallows, J. Farine, I. Felis, R. Filgas, F. Girard , et al. (37 additional authors not shown)

    Abstract: New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less th… ▽ More

    Submitted 2 August, 2017; v1 submitted 24 February, 2017; originally announced February 2017.

    Comments: 6 pages, 6 figures

    Journal ref: Phys. Rev. Lett. 118, 251301 (2017)

  14. arXiv:1611.01499  [pdf, other

    hep-ex astro-ph.CO physics.ins-det

    Final Results of the PICASSO Dark Matter Search Experiment

    Authors: E. Behnke, M. Besnier, P. Bhattacharjee, X. Dai, M. Das, A. Davour, F. Debris, N. Dhungana, J. Farine, M. Fines-Neuschild, S. Gagnebin, G. Giroux, E. Grace, C. M. Jackson, A. Kamaha, C. B. Krauss, M. Lafrenière, M. Laurin, I. Lawson, L. Lessard, I. Levine, D. Marlisov, J. -P. Martin, P. Mitra, A. J. Noble , et al. (9 additional authors not shown)

    Abstract: The PICASSO dark matter search experiment operated an array of 32 superheated droplet detectors containing 3.0 kg of C$_{4}$F$_{10}$ and collected an exposure of 231.4 kgd at SNOLAB between March 2012 and January 2014. We report on the final results of this experiment which includes for the first time the complete data set and improved analysis techniques including \mbox{acoustic} localization to… ▽ More

    Submitted 23 March, 2017; v1 submitted 4 November, 2016; originally announced November 2016.

    Comments: 24 pages, 7 figures

    Journal ref: Astropart. Phys. 90, 85-92 (2017)

  15. arXiv:1601.03729  [pdf, other

    astro-ph.CO physics.ins-det

    Improved dark matter search results from PICO-2L Run 2

    Authors: C. Amole, M. Ardid, I. J. Arnquist, D. M. Asner, D. Baxter, E. Behnke, P. Bhattacharjee, H. Borsodi, M. Bou-Cabo, S. J. Brice, D. Broemmelsiek, K. Clark, J. I. Collar, P. S. Cooper, M. Crisler, C. E. Dahl, M. Das, F. Debris, S. Fallows, J. Farine, I. Felis, R. Filgas, M. Fines-Neuschild, F. Girard, G. Giroux , et al. (33 additional authors not shown)

    Abstract: New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$ bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic threshold energy of 3.3$\,$keV. These data show that measures taken to control particulate contamination in the superheated fluid resulted in the absence of the anomalous background events observed in the first run of this bubble chamber. One single nu… ▽ More

    Submitted 25 March, 2016; v1 submitted 14 January, 2016; originally announced January 2016.

    Journal ref: Phys. Rev. D 93, 061101 (2016)

  16. arXiv:1510.07754  [pdf, other

    hep-ex astro-ph.CO physics.ins-det

    Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber

    Authors: C. Amole, M. Ardid, D. M. Asner, D. Baxter, E. Behnke, P. Bhattacharjee, H. Borsodi, M. Bou-Cabo, S. J. Brice, D. Broemmelsiek, K. Clark, J. I. Collar, P. S. Cooper, M. Crisler, C. E. Dahl, S. Daley, M. Das, F. Debris, N. Dhungana, J. Farine, I. Felis, R. Filgas, F. Girard, G. Giroux, A. Grandison , et al. (34 additional authors not shown)

    Abstract: New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays… ▽ More

    Submitted 3 March, 2016; v1 submitted 26 October, 2015; originally announced October 2015.

    Comments: v3 to reflect published version

    Journal ref: Phys. Rev. D 93, 052014 (2016)

  17. arXiv:1503.00008  [pdf, other

    astro-ph.CO physics.ins-det

    Dark Matter Search Results from the PICO-2L C$_3$F$_8$ Bubble Chamber

    Authors: C. Amole, M. Ardid, D. M. Asner, D. Baxter, E. Behnke, P. Bhattacharjee, H. Borsodi, M. Bou-Cabo, S. J. Brice, D. Broemmelsiek, K. Clark, J. I. Collar, P. S. Cooper, M. Crisler, C. E. Dahl, S. Daley, M. Das, F. Debris, N. Dhungana, J. Farine, I. Felis, R. Filgas, M. Fines-Neuschild, F. Girard, G. Giroux , et al. (32 additional authors not shown)

    Abstract: New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble chamber in the 2100 meter deep SNOLAB underground laboratory, with a total exposure of 211.5 kg-days at four different recoil energy thresholds ranging from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron recoil and alpha rejection capabilities at very low thresholds, including the first observation o… ▽ More

    Submitted 29 June, 2015; v1 submitted 27 February, 2015; originally announced March 2015.

    Comments: 6 pages, 6 figures, v2 to match published version

    Journal ref: Phys. Rev. Lett. 114, 231302 (2015)

  18. arXiv:1304.6001  [pdf, other

    physics.ins-det astro-ph.CO hep-ex

    Direct Measurement of the Bubble Nucleation Energy Threshold in a CF3I Bubble Chamber

    Authors: COUPP Collaboration, E. Behnke, T. Benjamin, S. J. Brice, D. Broemmelsiek, J. I. Collar, P. S. Cooper, M. Crisler, C. E. Dahl, D. Fustin, J. Hall, C. Harnish, I. Levine, W. H. Lippincott, T. Moan, T. Nania, R. Neilson, E. Ramberg, A. E. Robinson, A. Sonnenschein, E. Vázquez-Jáuregui, R. A. Rivera, L. Uplegger

    Abstract: We have directly measured the energy threshold and efficiency for bubble nucleation from iodine recoils in a CF3I bubble chamber in the energy range of interest for a dark matter search. These interactions cannot be probed by standard neutron calibration methods, so we develop a new technique by observing the elastic scattering of 12 GeV/c negative pions. The pions are tracked with a silicon pixel… ▽ More

    Submitted 31 January, 2014; v1 submitted 22 April, 2013; originally announced April 2013.

    Comments: 5 pages, 3 figures

    Report number: FERMILAB-PUB-10-318-A-CD-E

    Journal ref: Phys. Rev. D 88, 021102 (2013)

  19. arXiv:1204.3094  [pdf, ps, other

    astro-ph.CO hep-ex nucl-ex

    First dark matter search results from a 4-kg CF$_3$I bubble chamber operated in a deep underground site

    Authors: E. Behnke, J. Behnke, S. J. Brice, D. Broemmelsiek, J. I. Collar, A. Conner, P. S. Cooper, M. Crisler, C. E. Dahl, D. Fustin, E. Grace, J. Hall, M. Hu, I. Levine, W. H. Lippincott, T. Moan, T. Nania, E. Ramberg, A. E. Robinson, A. Sonnenschein, M. Szydagis, E. Vázquez-Jáuregui

    Abstract: New data are reported from the operation of a 4.0 kg CF$_{3}$I bubble chamber in the 6800-foot-deep SNOLAB underground laboratory. The effectiveness of ultrasound analysis in discriminating alpha-decay background events from single nuclear recoils has been confirmed, with a lower bound of $>$99.3% rejection of alpha-decay events. Twenty single nuclear recoil event candidates and three multiple bub… ▽ More

    Submitted 19 September, 2012; v1 submitted 13 April, 2012; originally announced April 2012.

    Comments: 9 pages, 7 figures, 2 tables

    Report number: FERMILAB-PUB-12-098-AD-AE-CD-E-PPD

    Journal ref: Phys. Rev. D 86, 052001 (2012)

  20. Constraints on Low-Mass WIMP Interactions on 19F from PICASSO

    Authors: The PICASSO Collaboration, S. Archambault, E. Behnke, P. Bhattacharjee, S. Bhattacharya, X. Dai, M. Das, A. Davour, F. Debris, N. Dhungana, J. Farine, S. Gagnebin, G. Giroux, E. Grace, C. M. Jackson, A. Kamaha, C. Krauss, S. Kumaratunga, M. Lafrenière, M. Laurin, I. Lawson, L. Lessard, I. Levine, C. Levy, R. P. MacDonald , et al. (15 additional authors not shown)

    Abstract: Recent results from the PICASSO dark matter search experiment at SNOLAB are reported. These results were obtained using a subset of 10 detectors with a total target mass of 0.72 kg of 19F and an exposure of 114 kgd. The low backgrounds in PICASSO allow recoil energy thresholds as low as 1.7 keV to be obtained which results in an increased sensitivity to interactions from Weakly Interacting Massive… ▽ More

    Submitted 28 March, 2012; v1 submitted 6 February, 2012; originally announced February 2012.

    Comments: 23 pages, 7 figures, to be published in Phys. Lett. B

    Journal ref: Phys. Lett. B711 (2012) 153-161

  21. arXiv:1011.4553  [pdf, ps, other

    physics.ins-det astro-ph.IM hep-ex nucl-ex

    New Insights into Particle Detection with Superheated Liquids

    Authors: S. Archambault, F. Aubin, M. Auger, M. Beleshi, E. Behnke, J. Behnke, B. Beltran, K. Clark, X. Dai, A. Davour, F. Debris. J. Farine, M. -H. Genest, G. Giroux, R. Gornea, R. Faust, H. Hinnefeld, A. Kamaha, C. B. Krauss, M. Lafrenière, M. Laurin, I. Lawson, C. Leroy, C. Lévy, L. Lessard, I. Levine , et al. (12 additional authors not shown)

    Abstract: We report new results obtained in calibrations of superheated liquid droplet detectors used in dark matter searches with different radiation sources (n,$α$,$γ$). In particular, detectors were spiked with alpha-emitters located inside and outside the droplets. It is shown that the responses are different, depending on whether alpha particles or recoil nuclei create the signals. The energy threshold… ▽ More

    Submitted 20 November, 2010; originally announced November 2010.

    Journal ref: New J.Phys.13:043006,2011

  22. arXiv:1008.3518  [pdf, ps, other

    astro-ph.CO hep-ex nucl-ex

    Improved Limits on Spin-Dependent WIMP-Proton Interactions from a Two Liter CF$_3$I Bubble Chamber

    Authors: E. Behnke, J. Behnke, S. J. Brice, D. Broemmelsiek, J. I. Collar, P. S. Cooper, M. Crisler, C. E. Dahl, D. Fustin, J. Hall, J. H. Hinnefeld, M. Hu, I. Levine, E. Ramberg, T. Shepherd, A. Sonnenschein, M. Szydagis

    Abstract: Data from the operation of a bubble chamber filled with 3.5 kg of CF$_{3}$I in a shallow underground site are reported. An analysis of ultrasound signals accompanying bubble nucleations confirms that alpha decays generate a significantly louder acoustic emission than single nuclear recoils, leading to an efficient background discrimination. Three dark matter candidate events were observed during a… ▽ More

    Submitted 7 March, 2011; v1 submitted 20 August, 2010; originally announced August 2010.

    Comments: 4 pages, 4 figures V2 submitted to match journal version

    Journal ref: Phys.Rev.Lett.106:021303,2011

  23. Dark Matter Spin-Dependent Limits for WIMP Interactions on 19-F by PICASSO

    Authors: S. Archambault, F. Aubin, M. Auger, E. Behnke, B. Beltran, K. Clark, X. Dai, A. Davour, J. Farine, R. Faust, M. -H. Genest, G. Giroux, R. Gornea, C. Krauss, S. Kumaratunga, I. Lawson, C. Leroy, L. Lessard, C. Levy, I. Levine, R. MacDonald, J. -P. Martin, P. Nadeau, A. Noble, M. -C. Piro , et al. (7 additional authors not shown)

    Abstract: The PICASSO experiment at SNOLAB reports new results for spin-dependent WIMP interactions on $^{19}$F using the superheated droplet technique. A new generation of detectors and new features which enable background discrimination via the rejection of non-particle induced events are described. First results are presented for a subset of two detectors with target masses of $^{19}$F of 65 g and 69 g… ▽ More

    Submitted 10 November, 2009; v1 submitted 2 July, 2009; originally announced July 2009.

    Comments: Revised version, accepted for publication in Phys. Lett. B, 20 pages, 7 figures

    Journal ref: Phys.Lett.B682:185-192,2009

  24. arXiv:0807.1536  [pdf, ps, other

    physics.ins-det hep-ex

    Discrimination of nuclear recoils from alpha particles with superheated liquids

    Authors: F. Aubin, M. Auger, E. Behnke, B. Beltran, K. Clark, X. Dai, A. Davour, M. -H. Genest, G. Giroux, R. Gornea, R. Faust, C. B. Krauss, C. Leroy, L. Lessard, I. Levine, C. Levy, J. -P. Martin, T. Morlat, A. J. Noble, P. Nadeau, M. -C. Piro, S. Pospisil, T. Shepherd, J. Sodomka, N. Starinski , et al. (4 additional authors not shown)

    Abstract: The PICASSO collaboration observed for the first time a significant difference between the acoustic signals induced by neutrons and alpha particles in a detector based on superheated liquids. This new discovery offers the possibility of improved background suppression and could be especially useful for dark matter experiments. This new effect may be attributed to the formation of multiple bubble… ▽ More

    Submitted 23 September, 2008; v1 submitted 10 July, 2008; originally announced July 2008.

    Comments: 7 pages, 4 figures. accepted for publication in New Journal of Physics

    Journal ref: NewJ.Phys.10:103017,2008

  25. arXiv:0804.2886  [pdf, ps, other

    astro-ph hep-ex physics.ins-det

    Improved Spin-Dependent WIMP Limits from a Bubble Chamber

    Authors: E. Behnke, J. I. Collar, P. S. Cooper, K. Crum, M. Crisler, M. Hu, I. Levine, D. Nakazawa, H. Nguyen, B. Odom, E. Ramberg, J. Rasmussen, N. Riley, A. Sonnenschein, M. Szydagis, R. Tschirhart

    Abstract: Bubble Chambers provided the dominant particle detection technology in accelerator experiments for several decades, eventually falling into disuse with the advent of other techniques. We report here on the first period of operation of an ultra-clean, room-temperature bubble chamber containing 1.5 kg of superheated CF$_{3}$I, a target maximally sensitive to spin-dependent and -independent Weakly… ▽ More

    Submitted 17 April, 2008; originally announced April 2008.

    Comments: This is the author's version of the work. It is posted here by permission of the AAAS for personal use, not for redistribution. The definitive version was published in Science 319, 15 February 2008, doi:10.1126/science.1149999

    Journal ref: Science 319:933-936,2008

  26. Response of Superheated Droplet Detectors of the PICASSO Dark Matter Search Experiment

    Authors: The PICASSO Collaboration, M. Barnabe-Heider, E. Behnke, K. Clark, M. Di Marco, P. Doane, W. Feighery, M. -H. Genest, R. Gornea, R. Guenette, S. Kanagalingam, C. B. Krauss, C. Leroy, L. Lessard, I. Levine, J. -P. Martin, C. Muthusi, A. J. Noble, R. Noulty, U. Wichoski, V. Zacek

    Abstract: We present results of systematic studies of the radiation response of superheated liquid droplet detectors, which are used in the PICASSO dark matter search experiment. This detection technique is based on the phase transitions of superheated liquid Freon droplets dispersed and trapped in a polymerized gel. Phase transitions can be induced by nuclear recoils following particle interactions and,… ▽ More

    Submitted 15 August, 2005; originally announced August 2005.

    Comments: 70 pages, 33 low resolution figures; higher resolution figures available at http://picassoweb.lps.umontreal.ca/ . Submitted to NIM A

    Journal ref: Nucl.Instrum.Meth. A555 (2005) 184-204

  27. Improved Spin Dependent Limits from the PICASSO Dark Matter Search Experiment

    Authors: The PICASSO Collaboration, M. Barnabe-Heider, E. Behnke, K. Clark, M. Di Marco, P. Doane, W. Feighery, M. -H. Genest, R. Gornea, R. Guenette, S. Kanagalingam, C. B. Krauss, C. Leroy, L. Lessard, I. Levine, J. -P. Martin, C. Muthusi, A. J. Noble, R. Noulty, U. Wichoski, V. Zacek

    Abstract: The PICASSO experiment reports an improved limit for the existence of cold dark matter WIMPs interacting via spin-dependent interactions with nuclei. The experiment is installed in the Sudbury Neutrino Observatory at a depth of 2070 m. With superheated C4F10 droplets as the active material, and an exposure of 1.98+-0.19 kgd, no evidence for a WIMP signal was found. For a WIMP mass of 29 GeV/c2,… ▽ More

    Submitted 9 August, 2005; v1 submitted 15 February, 2005; originally announced February 2005.

    Comments: 24 pages, 6 figures; text expanded for clarity, new figure added. To be published in Phys. Lett. B

    Journal ref: Phys.Lett.B624:186-194,2005

  28. arXiv:physics/0408126  [pdf

    physics.ins-det hep-ex

    Simulation of Special Bubble Detectors for PICASSO

    Authors: The PICASSO Collaboration, G. Azuelos, M. Barnabe-Heider, E. Behnke, K. Clark, M. Di Marco, P. Doane, W. Feighery, M-H. Genest, R. Gornea, R. Guenette, S. Kanagalingam, C. Krauss, C. Leroy, L. Lessard, I. Levine, J. P. Martin, A. J. Noble, R. Noulty, S. N. Shore, U. Wichoski, V . Zacek

    Abstract: The PICASSO project is a cold dark matter (CDM) search experiment relying on the superheated droplet technique. The detectors use superheated freon liquid droplets (active material) dispersed and trapped in a polymerized gel. This detection technique is based on the phase transition of superheated droplets at about room temperature and ambient pressure. The phase transition is induced by nuclear… ▽ More

    Submitted 30 August, 2004; originally announced August 2004.

    Comments: 13 pages, 4 figures. To appear in the Proceedings of the 14th International Conference on Solid State Dosimetry, June 27 - July 2 2004, Yale University, New Haven, CT, USA

    Journal ref: Radiat.Prot.Dosim.120:499-502,2006

  29. Status of the PICASSO Project

    Authors: The PICASSO Collaboration, M. Barnabe-Heider, E. Behnke, J. Behnke, M. Di Marco, P. Doane, W. Feighery, M-H. Genest, R. Gornea, S. Kanagalingam, C. Leroy, L. Lessard, I. Levine, J. P. Martin, C. Mathusi, J. Neurenberg, A. J. Noble, R. Noulty, R. Nymberg, S. N. Shore, U. Wichoski, V. Zacek

    Abstract: The Picasso project is a dark matter search experiment based on the superheated droplet technique. Preliminary runs performed at the Picasso Lab in Montreal have showed the suitability of this detection technique to the search for weakly interacting cold dark matter particles. In July 2002, a new phase of the project started. A batch of six 1-liter detectors with an active mass of approximately… ▽ More

    Submitted 17 December, 2003; originally announced December 2003.

    Comments: 3 pages, 2 figures. To appear in the Proceedings of the TAUP 2003 conference, 5-9 September, 2003, University of Washington, Seattle, USA

    Journal ref: Nuclear Physics B (Proc. Suppl.) 138 (2005) 160

  30. arXiv:hep-ex/0311034  [pdf, ps, other

    hep-ex

    Characterization of the Response of Superheated Droplet (Bubble) Detectors

    Authors: The PICASSO Collaboration, M. Barnabe-Heider, E. Behnke, J. Behnke, M. Di Marco, P. Doane, W. Feighery, M-H. Genest, R. Gornea, S. Kanagalingam, C. Leroy, L. Lessard, I. Levine, J. P. Martin, C. Mathusi, J. Neurenberg, A. J. Noble, R. Noulty, R. Nymberg, S. N. Shore, U. Wichoski, V. Zacek

    Abstract: The PICASSO project is a cold dark matter (CDM) search experiment relying on the superheated droplet technique. The detectors use superheated freon liquid droplets (active material) dispersed and trapped in a polymerized gel. This detection technique is based on the phase transition of superheated droplets at room or moderate temperatures. The phase transitions are induced by nuclear recoils whe… ▽ More

    Submitted 14 November, 2003; originally announced November 2003.

    Comments: 10 pages, 7 figures, to appear in the "Proceedings of the 8th ICATPP Conference on Astroparticle, Particle, Space Physics, Detectors and Medical Physics Applications", 6-10 October 2003, Villa Erba, Como, Italy