-
Parameter choices in HaarPSI for IQA with medical images
Authors:
Clemens Karner,
Janek Gröhl,
Ian Selby,
Judith Babar,
Jake Beckford,
Thomas R Else,
Timothy J Sadler,
Shahab Shahipasand,
Arthikkaa Thavakumar,
Michael Roberts,
James H. F. Rudd,
Carola-Bibiane Schönlieb,
Jonathan R Weir-McCall,
Anna Breger
Abstract:
When developing machine learning models, image quality assessment (IQA) measures are a crucial component for the evaluation of obtained output images. However, commonly used full-reference IQA (FR-IQA) measures have been primarily developed and optimized for natural images. In many specialized settings, such as medical images, this poses an often overlooked problem regarding suitability. In previo…
▽ More
When developing machine learning models, image quality assessment (IQA) measures are a crucial component for the evaluation of obtained output images. However, commonly used full-reference IQA (FR-IQA) measures have been primarily developed and optimized for natural images. In many specialized settings, such as medical images, this poses an often overlooked problem regarding suitability. In previous studies, the FR-IQA measure HaarPSI showed promising behavior regarding generalizability. The measure is based on Haar wavelet representations and the framework allows optimization of two parameters. So far, these parameters have been aligned for natural images. Here, we optimize these parameters for two medical image data sets, a photoacoustic and a chest X-ray data set, with IQA expert ratings. We observe that they lead to similar parameter values, different to the natural image data, and are more sensitive to parameter changes. We denote the novel optimized setting as HaarPSI$_{MED}$, which improves the performance of the employed medical images significantly (p<0.05). Additionally, we include an independent CT test data set that illustrates the generalizability of HaarPSI$_{MED}$, as well as visual examples that qualitatively demonstrate the improvement. The results suggest that adapting common IQA measures within their frameworks for medical images can provide a valuable, generalizable addition to employment of more specific task-based measures.
△ Less
Submitted 8 April, 2025; v1 submitted 31 October, 2024;
originally announced October 2024.
-
Primeness of generalized parking functions
Authors:
Sam Armon,
Joanne Beckford,
Dillon Hanson,
Naomi Krawzik,
Olya Mandelshtam,
Lucy Martinez,
Catherine Yan
Abstract:
Classical parking functions are a generalization of permutations that appear in many combinatorial structures. Prime parking functions are indecomposable components such that any classical parking function can be uniquely described as a direct sum of prime ones. In this article, we extend the notion of primeness to three generalizations of classical parking functions: vector parking functions,…
▽ More
Classical parking functions are a generalization of permutations that appear in many combinatorial structures. Prime parking functions are indecomposable components such that any classical parking function can be uniquely described as a direct sum of prime ones. In this article, we extend the notion of primeness to three generalizations of classical parking functions: vector parking functions, $(p,q)$-parking functions, and two-dimensional vector parking functions. We study their enumeration by obtaining explicit formulas for the number of prime vector parking functions when the vector is an arithmetic progression, prime $(p,q)$-parking functions, and prime two-dimensional vector parking functions when the weight matrix is an affine transformation of the coordinates.
△ Less
Submitted 29 October, 2024;
originally announced October 2024.
-
A study on the adequacy of common IQA measures for medical images
Authors:
Anna Breger,
Clemens Karner,
Ian Selby,
Janek Gröhl,
Sören Dittmer,
Edward Lilley,
Judith Babar,
Jake Beckford,
Thomas R Else,
Timothy J Sadler,
Shahab Shahipasand,
Arthikkaa Thavakumar,
Michael Roberts,
Carola-Bibiane Schönlieb
Abstract:
Image quality assessment (IQA) is standard practice in the development stage of novel machine learning algorithms that operate on images. The most commonly used IQA measures have been developed and tested for natural images, but not in the medical setting. Reported inconsistencies arising in medical images are not surprising, as they have different properties than natural images. In this study, we…
▽ More
Image quality assessment (IQA) is standard practice in the development stage of novel machine learning algorithms that operate on images. The most commonly used IQA measures have been developed and tested for natural images, but not in the medical setting. Reported inconsistencies arising in medical images are not surprising, as they have different properties than natural images. In this study, we test the applicability of common IQA measures for medical image data by comparing their assessment to manually rated chest X-ray (5 experts) and photoacoustic image data (2 experts). Moreover, we include supplementary studies on grayscale natural images and accelerated brain MRI data. The results of all experiments show a similar outcome in line with previous findings for medical images: PSNR and SSIM in the default setting are in the lower range of the result list and HaarPSI outperforms the other tested measures in the overall performance. Also among the top performers in our experiments are the full reference measures FSIM, LPIPS and MS-SSIM. Generally, the results on natural images yield considerably higher correlations, suggesting that additional employment of tailored IQA measures for medical imaging algorithms is needed.
△ Less
Submitted 20 December, 2024; v1 submitted 29 May, 2024;
originally announced May 2024.