-
Design and performance of LED calibration system prototype for the lead tungstate crystal calorimeter
Authors:
V. A. Batarin,
J. Butler,
A. M. Davidenko,
A. A. Derevschikov,
Y. M. Goncharenko,
V. N. Grishin,
V. A. Kachanov,
V. Y. Khodyrev,
A. S. Konstantinov,
V. A. Kormilitsin,
V. I. Kravtsov,
Y. Kubota,
V. S. Lukanin,
Y. A. Matulenko,
Y. M. Melnick,
A. P. Meschanin,
N. E. Mikhalin,
N. G. Minaev,
V. V. Mochalov,
D. A. Morozov,
L. V. Nogach,
A. V. Ryazantsev,
P. A. Semenov,
V. K. Semenov,
K. E. Shestermanov
, et al. (6 additional authors not shown)
Abstract:
A highly stable monitoring system based on blue and red light emitting diodes coupled to a distribution network comprised of optical fibers has been developed for an electromagnetic calorimeter that uses lead tungstate crystals readout with photomultiplier tubes. We report of the system prototype design and on the results of laboratory tests. Stability better than 0.1% (r.m.s.) has been achieved…
▽ More
A highly stable monitoring system based on blue and red light emitting diodes coupled to a distribution network comprised of optical fibers has been developed for an electromagnetic calorimeter that uses lead tungstate crystals readout with photomultiplier tubes. We report of the system prototype design and on the results of laboratory tests. Stability better than 0.1% (r.m.s.) has been achieved during one week of prototype operation.
△ Less
Submitted 29 September, 2005; v1 submitted 28 September, 2005;
originally announced September 2005.
-
Correlation of Beam Electron and LED Signal Losses under Irradiation and Long-term Recovery of Lead Tungstate Crystals
Authors:
V. A. Batarin,
J. Butler,
A. M. Davidenko,
A. A. Derevschikov,
Y. M. Goncharenko,
V. N. Grishin,
V. A. Kachanov,
A. S. Konstantinov,
V. I. Kravtsov,
Y. Kubota,
V. S. Lukanin,
Y. A. Matulenko,
Y. M. Melnick,
A. P. Meschanin,
N. E. Mikhalin,
N. G. Minaev,
V. V. Mochalov,
D. A. Morozov,
L. V. Nogach,
A. V. Ryazantsev,
P. A. Semenov,
V. K. Semenov,
K. E. Shestermanov,
L. F. Soloviev,
S. Stone
, et al. (4 additional authors not shown)
Abstract:
Radiation damage in lead tungstate crystals reduces their transparency. The calibration that relates the amount of light detected in such crystals to incident energy of photons or electrons is of paramount importance to maintaining the energy resolution the detection system. We report on tests of lead tungstate crystals, read out by photomultiplier tubes, exposed to irradiation by monoenergetic…
▽ More
Radiation damage in lead tungstate crystals reduces their transparency. The calibration that relates the amount of light detected in such crystals to incident energy of photons or electrons is of paramount importance to maintaining the energy resolution the detection system. We report on tests of lead tungstate crystals, read out by photomultiplier tubes, exposed to irradiation by monoenergetic electron or pion beams. The beam electrons themselves were used to measure the scintillation light output, and a blue light emitting diode (LED) was used to track variations of crystals transparency. We report on the correlation of the LED measurement with radiation damage by the beams and also show that it can accurately monitor the crystals recovery from such damage.
△ Less
Submitted 13 April, 2005;
originally announced April 2005.
-
Study of Possible Scintillation Mechanism Damage in PbWO4 Crystals After Pion Irradiation
Authors:
V. A. Batarin,
J. Butler,
T. Y. Chen,
A. M. Davidenko,
A. A. Derevschikov,
Y. M. Goncharenko,
V. N. Grishin,
V. A. Kachanov,
A. S. Konstantinov,
V. I. Kravtsov,
V. A. Kormilitsin,
Y. Kubota,
V. S. Lukanin,
Y. A. Matulenko,
Y. M. Melnick,
A. P. Meschanin,
N. E. Mikhalin,
N. G. Minaev,
V. V. Mochalov,
D. A. Morozov,
L. V. Nogach,
A. V. Ryazantsev,
P. A. Semenov,
V. K. Semenov,
K. E. Shestermanov
, et al. (6 additional authors not shown)
Abstract:
We employed two independent methods to study possible damage to the scintillation mechanism in lead tungstate crystals due to irradiation by a 34 GeV pion beam. First, 10 crystals were irradiated simultaneously over 30 hours by a narrow beam, so that only a small region of each crystal was affected. We studied the effect of the irradiation on the light output non-uniformity. If a localized degra…
▽ More
We employed two independent methods to study possible damage to the scintillation mechanism in lead tungstate crystals due to irradiation by a 34 GeV pion beam. First, 10 crystals were irradiated simultaneously over 30 hours by a narrow beam, so that only a small region of each crystal was affected. We studied the effect of the irradiation on the light output non-uniformity. If a localized degradation was observed, it would indicate damage to the scintillation mechanism. Secondly, we detected light output using two phototubes attached to sides of a crystal. Since these phototubes detect scintillation light only from a small localized region, the effect of transmission loss should be minimal. We did not see any statistically significant evidence for scintillation mechanism damage with either method. The effect is consistent with zero, and the upper limit is 0.5% at 95% C.L.
△ Less
Submitted 22 October, 2004; v1 submitted 19 October, 2004;
originally announced October 2004.
-
Search for Theta(1540)^+ in exclusive proton-induced reaction p+C(N) \to Theta^+ \bar{K}^0 + C(N) at the energy of 70 GeV
Authors:
SPHINX Collaboration,
Yu. M. Antipov,
A. V. Artamonov,
V. A. Batarin,
O. V. Eroshin,
V. Z. Kolganov,
A. S. Konstantinov,
A. P. Kozhevnikov,
V. F. Kurshetsov,
A. E. Kushnirenko,
L. G. Landsberg,
V. M. Leontiev,
G. S. Lomkatsi,
V. A. Mukhin,
V. V. Molchanov,
A. P. Nilov,
D. I. Patalakha,
S. V. Petrenko,
A. I. Petrukhin,
V. T. Smolyankin,
D. V. Vavilov,
V. A. Victorov
Abstract:
A search for narrow Theta(1540)^+, a candidate for pentaquark baryon with positive strangeness, has been performed in an exclusive proton-induced reaction p+C(N) \to Theta^+ \bar{K}^0 + C(N) on carbon nuclei or quasifree nucleons at E_{beam}=70 GeV (sqrt{s} = 11.5 GeV) studying nK^+, pK_S and pK_L decay channels of Theta(1540)^+ in four different final states of the Theta^+ \bar{K}^0 system. In…
▽ More
A search for narrow Theta(1540)^+, a candidate for pentaquark baryon with positive strangeness, has been performed in an exclusive proton-induced reaction p+C(N) \to Theta^+ \bar{K}^0 + C(N) on carbon nuclei or quasifree nucleons at E_{beam}=70 GeV (sqrt{s} = 11.5 GeV) studying nK^+, pK_S and pK_L decay channels of Theta(1540)^+ in four different final states of the Theta^+ \bar{K}^0 system. In order to assess the quality of the identification of the final states with neutron or K_L we reconstructed Lambda(1520)\to nK_S and phi\to K_LK_S decays in the calibration reactions p+C(N)\to Lambda(1520)K^+ + C(N) and p+C(N)\to pφ+ C(N). We found no evidence for narrow pentaquark peak in any of the studied final states and decay channels. Assuming that the production characteristics of the Theta^+ \bar{K^0} system are not drastically different from those of the Lambda(1520)K^+ and pφsystems, we established upper limits on the cross section ratios sigma(Theta^+\bar{K}^0)/sigma(Lambda(1520)K^+) < 0.02 and sigma(Theta^+\bar{K}^0)/sigma(pφ) < 0.15 at 90% CL and a preliminary upper limit for the forward hemisphere cross section sigma(Theta^+\bar{K}^0) < 30 nb/nucleon.
△ Less
Submitted 14 July, 2004;
originally announced July 2004.
-
Measurement of the radiative decay width Γ[Λ(1520) --> Λγ] with the SPHINX spectrometer
Authors:
Yu. M. Antipov,
A. V. Artamonov,
V. A. Batarin,
D. V. Vavilov,
V. A. Victorov,
O. V. Eroshin,
S. V. Golovkin,
Yu. P. Gorin,
V. Z. Kolganov,
A. P. Kozhevnikov,
A. S. Konstantinov,
V. P. Kubarovsky,
V. F. Kurshetsov,
L. G. Landsberg,
V. M. Leontiev,
G. S. Lomkatsi,
V. V. Molchanov,
V. A. Mukhin,
A. F. Nilov,
D. I. Patalakha,
S. V. Petrenko,
V. T. Smolyankin
Abstract:
The radiative decay Λ(1520) --> Λγwas measured directly in the study of exclusive diffractive-like reaction p + N --> Λ(1520) K^+ + N, Λ(1520) --> Λγwith the SPHINX spectrometer. The values of the branching and partial width of this radiative decay were obtained: BR[Λ(1520) --> Λγ] = (1.02+/-0.21(stat)+/-0.15(syst))x10^{-2} and Γ[Λ(1520) --> Λγ] = 159+/-33(stat)+/-26(syst) keV.
The radiative decay Λ(1520) --> Λγwas measured directly in the study of exclusive diffractive-like reaction p + N --> Λ(1520) K^+ + N, Λ(1520) --> Λγwith the SPHINX spectrometer. The values of the branching and partial width of this radiative decay were obtained: BR[Λ(1520) --> Λγ] = (1.02+/-0.21(stat)+/-0.15(syst))x10^{-2} and Γ[Λ(1520) --> Λγ] = 159+/-33(stat)+/-26(syst) keV.
△ Less
Submitted 27 October, 2004; v1 submitted 15 June, 2004;
originally announced June 2004.
-
Development of a Momentum Determined Electron Beam in the 1 -45 GeV Range
Authors:
V. A. Batarin,
J. Butler,
A. A. Derevschikov,
Yu. V. Formin,
V. Frolov,
V. N. Grishin,
V. A. Kachanov,
V. Y. Khodyrev,
A. S. Konstantinov,
V. I. Krasvtsov,
Y. Kubota,
V. M. Leontiev,
V. A. Maisheev,
Ya. A. Matulenko,
A. P. Meschanin,
Y. M. Melnick,
N. G. Minaev,
V. V. Mochalov,
D. A. Morozov,
L. V. Nogach,
P. A. Semenov,
K. E. Shestermanov,
L. F. Soloviev,
V. L. Solovianov,
S. Stone
, et al. (5 additional authors not shown)
Abstract:
A beam line for electrons with energies in the range of 1 to 45 GeV, low contamination of hadrons and muons and high intensity up to 10^6 per accelerator spill at 27 GeV was setup at U70 accelerator in Protvino, Russia. A beam tagging system based on drift chambers with 160 micron resolution was able to measure relative electron beam momentum precisely. The resolution sigma_p p was 0.13% at 45 G…
▽ More
A beam line for electrons with energies in the range of 1 to 45 GeV, low contamination of hadrons and muons and high intensity up to 10^6 per accelerator spill at 27 GeV was setup at U70 accelerator in Protvino, Russia. A beam tagging system based on drift chambers with 160 micron resolution was able to measure relative electron beam momentum precisely. The resolution sigma_p p was 0.13% at 45 GeV where multiple scattering is negligible. This test beam setup provided the possibility to study properties of lead tungstate crystals (PbWO_4) for the BTeV experiment at Fermilab.
△ Less
Submitted 9 August, 2002;
originally announced August 2002.