-
Open-Loop and Model Predictive Control for Electric Vehicle Charging to Manage Excess Renewable Energy Supply in Texas
Authors:
Kelsey M. Nelson,
Maureen S. Golan,
Matthew D. Bartos,
Javad Mohammadi
Abstract:
Modern power grids are evolving to become more interconnected, include more electric vehicles (EVs), and utilize more renewable energy sources (RES). Increased interconnectivity provides an opportunity to manage EVs and RES by using price signaling to shift EV loads towards periods of high RES output. This work uses ERCOT's 2035 RES installation plans and projections for Texas's EV fleet to examin…
▽ More
Modern power grids are evolving to become more interconnected, include more electric vehicles (EVs), and utilize more renewable energy sources (RES). Increased interconnectivity provides an opportunity to manage EVs and RES by using price signaling to shift EV loads towards periods of high RES output. This work uses ERCOT's 2035 RES installation plans and projections for Texas's EV fleet to examine and compare how both open-loop control and model predictive control (MPC) schemes can leverage time varying rates for EV charging to utilize excess RES supply that may otherwise be underutilized in a highly weather-dependent grid. The results show that while open-loop control increases RES usage, MPC increases RES usage even further by responding to RES outputs that differ from forecasts due to the inherent uncertainty of weather predictions. If MPC is used with time steps that are too frequent, however, difficulties arise; EV owners may find it too onerous to keep up with changing price structures, and frequent over-corrections to charging profiles can lead to a ``rebound peak" phenomenon. Therefore, control schemes should balance maximizing RES usage with ensuring customer participation.
△ Less
Submitted 11 December, 2024;
originally announced December 2024.
-
Aging suppression in Multistrip Multigap Resistive Plate Chambers for high counting rate experiments
Authors:
M. Petris,
V. Aprodu,
D. Bartos,
D. Dorobantu,
V. Duta,
M. Petrovici,
A. Radu
Abstract:
A long term operation of Multi-Strip Multi-Gap Resistive Plate Chambers (MSMGRPC) with gas mixtures based on C2H2F4 and SF6 leads to aging effects, observed as depositions on the surface of the resistive electrodes. Moreover, enhanced depositions and higher noise rates were evidenced around the nylon spacers used for defining the gas gaps between the resistive electrodes. The aging effects are ref…
▽ More
A long term operation of Multi-Strip Multi-Gap Resistive Plate Chambers (MSMGRPC) with gas mixtures based on C2H2F4 and SF6 leads to aging effects, observed as depositions on the surface of the resistive electrodes. Moreover, enhanced depositions and higher noise rates were evidenced around the nylon spacers used for defining the gas gaps between the resistive electrodes. The aging effects are reflected in an increase of the dark current and dark counting rate, with negative impact on the long term performance of the chamber and data volume in a free running readout mode operation. MSMGRPC prototypes designed with a direct gas flow through the gas gaps and minimization of the number of spacers in the active area were developed as mitigation solution. Prototypes with this new design and different granularities were assembled using fishing line as spacers and investigated for aging effects. Although a significant reduction in the dark current and dark counting rate was evidenced, dark counting rate localized around the fishing line spacers remains. In this paper, a new generation of direct flow chambers based on discrete spacers is presented. The results of their aging investigations show that, even at lower gas flows, the aging effects become negligible.
△ Less
Submitted 21 March, 2024;
originally announced March 2024.
-
The Keck Planet Imager and Characterizer: A dedicated single-mode fiber injection unit for high resolution exoplanet spectroscopy
Authors:
Jacques-Robert Delorme,
Nemanja Jovanovic,
Daniel Echeverri,
Dimitri Mawet,
J. Kent Wallace,
Randall D. Bartos,
Sylvain Cetre,
Peter Wizinowich,
Sam Ragland,
Scott Lilley,
Edward Wetherell,
Greg Doppmann,
Jason J. Wang,
Evan C. Morris,
Jean-Baptiste Ruffio,
Emily C. Martin,
Michael P. Fitzgerald,
Garreth Ruane,
Tobias Schofield,
Nick Suominen,
Benjamin Calvin,
Eric Wang,
Kenneth Magnone,
Christopher Johnson,
Ji Man Sohn
, et al. (6 additional authors not shown)
Abstract:
The Keck Planet Imager and Characterizer (KPIC) is a purpose-built instrument to demonstrate new technological and instrumental concepts initially developed for the exoplanet direct imaging field. Located downstream of the current Keck II adaptive optic system, KPIC contains a fiber injection unit (FIU) capable of combining the high-contrast imaging capability of the adaptive optics system with th…
▽ More
The Keck Planet Imager and Characterizer (KPIC) is a purpose-built instrument to demonstrate new technological and instrumental concepts initially developed for the exoplanet direct imaging field. Located downstream of the current Keck II adaptive optic system, KPIC contains a fiber injection unit (FIU) capable of combining the high-contrast imaging capability of the adaptive optics system with the high dispersion spectroscopy capability of the current Keck high resolution infrared spectrograph (NIRSPEC). Deployed at Keck in September 2018, this instrument has already been used to acquire high resolution spectra ($R > 30,000$) of multiple targets of interest. In the near term, it will be used to spectrally characterize known directly imaged exoplanets and low-mass brown dwarf companions visible in the northern hemisphere with a spectral resolution high enough to enable spin and planetary radial velocity measurements as well as Doppler imaging of atmospheric weather phenomena. Here we present the design of the FIU, the unique calibration procedures needed to operate a single-mode fiber instrument and the system performance.
△ Less
Submitted 26 July, 2021;
originally announced July 2021.
-
Ageing studies of Multi-Strip Multi-Gap Resistive Plate Counters based on low resistivity glass electrodes in high irradiation dose
Authors:
D. Bartos,
C. Burducea,
I. Burducea,
G. Caragheorgheopol,
F. Constantin,
L. Craciun,
D. Dorobantu,
M. Ghena,
D. Iancu,
A. Marcu,
G. Mateescu,
P. Mereuta,
V. Moise,
C. Negrila,
D. Negut,
M. Petris,
M. Petrovici,
L. Radulescu,
V. Aprodu,
L. Prodan,
A. radu,
G. Stoian
Abstract:
Detailed tests and analysis of ageing effects of high irradiation dose on Multi-Strip Multi-Gap Resistive Plate Counters based on low resistivity glass electrodes were performed. MSMGRPC efficiency and cluster size before irradiation are measured and compared with their values after irradiation in a high irradiation dose accessed at a multi-purpose irradiation facility of IFIN-HH based on $^{60}$C…
▽ More
Detailed tests and analysis of ageing effects of high irradiation dose on Multi-Strip Multi-Gap Resistive Plate Counters based on low resistivity glass electrodes were performed. MSMGRPC efficiency and cluster size before irradiation are measured and compared with their values after irradiation in a high irradiation dose accessed at a multi-purpose irradiation facility of IFIN-HH based on $^{60}$Co source. The composition and properties of the deposited layers on the glass electrodes, studied based on a multitude of analysis methods, i.e. SEM, XPS, foil-ERDA, RBS, AFM and THz-TDS, are presented.
△ Less
Submitted 25 August, 2021; v1 submitted 24 May, 2021;
originally announced May 2021.
-
A method to adjust the impedance of the transmission line in a Multi-Strip Multi-Gap Resistive Plate Counter
Authors:
D. Bartoş,
M. Petriş,
M. Petrovici,
L. Rădulescu,
V. Simion
Abstract:
While in a triggered experiment the matching of the RPC transmission line impedance with the one of the front-end electronics is less critical, for a trigger-less data recording this becomes mandatory. As expected, impedance matching is not straightforward when other requirements in terms of time and position resolutions, efficiency and granularity, have to be fulfilled in the same time. A method…
▽ More
While in a triggered experiment the matching of the RPC transmission line impedance with the one of the front-end electronics is less critical, for a trigger-less data recording this becomes mandatory. As expected, impedance matching is not straightforward when other requirements in terms of time and position resolutions, efficiency and granularity, have to be fulfilled in the same time. A method and the very first results obtained with a RPC prototype built based on it, presented in this paper, show that the impedance matching, independent of its granularity, can be achieved using an innovative architecture of the RPC.
△ Less
Submitted 8 August, 2017;
originally announced August 2017.
-
Speckle suppression and companion detection using coherent differential imaging
Authors:
Michael Bottom,
J. Kent Wallace,
Randall D. Bartos,
J. Chris Shelton,
Eugene Serabyn
Abstract:
Residual speckles due to aberrations arising from optical errors after the split between the wavefront sensor and the science camera path are the most significant barriers to imaging extrasolar planets. While speckles can be suppressed using the science camera in conjunction with the deformable mirror, this requires knowledge of the phase of the electric field in the focal plane. We describe a met…
▽ More
Residual speckles due to aberrations arising from optical errors after the split between the wavefront sensor and the science camera path are the most significant barriers to imaging extrasolar planets. While speckles can be suppressed using the science camera in conjunction with the deformable mirror, this requires knowledge of the phase of the electric field in the focal plane. We describe a method which combines a coronagraph with a simple phase-shifting interferometer to measure and correct speckles in the full focal plane. We demonstrate its initial use on the Stellar Double Coronagraph at the Palomar Observatory. We also describe how the same hardware can be used to distinguish speckles from true companions by measuring the coherence of the optical field in the focal plane. We present results observing the brown dwarf HD 49197b with this technique, demonstrating the ability to detect the presence of a companion even when it is buried in the speckle noise, without the use of any standard "calibration" techniques. We believe this is the first detection of a substellar companion using the coherence properties of light.
△ Less
Submitted 3 October, 2016;
originally announced October 2016.
-
Challenges in QCD matter physics - The Compressed Baryonic Matter experiment at FAIR
Authors:
CBM Collaboration,
T. Ablyazimov,
A. Abuhoza,
R. P. Adak,
M. Adamczyk,
K. Agarwal,
M. M. Aggarwal,
Z. Ahammed,
F. Ahmad,
N. Ahmad,
S. Ahmad,
A. Akindinov,
P. Akishin,
E. Akishina,
T. Akishina,
V. Akishina,
A. Akram,
M. Al-Turany,
I. Alekseev,
E. Alexandrov,
I. Alexandrov,
S. Amar-Youcef,
M. Anđelić,
O. Andreeva,
C. Andrei
, et al. (563 additional authors not shown)
Abstract:
Substantial experimental and theoretical efforts worldwide are devoted to explore the phase diagram of strongly interacting matter. At LHC and top RHIC energies, QCD matter is studied at very high temperatures and nearly vanishing net-baryon densities. There is evidence that a Quark-Gluon-Plasma (QGP) was created at experiments at RHIC and LHC. The transition from the QGP back to the hadron gas is…
▽ More
Substantial experimental and theoretical efforts worldwide are devoted to explore the phase diagram of strongly interacting matter. At LHC and top RHIC energies, QCD matter is studied at very high temperatures and nearly vanishing net-baryon densities. There is evidence that a Quark-Gluon-Plasma (QGP) was created at experiments at RHIC and LHC. The transition from the QGP back to the hadron gas is found to be a smooth cross over. For larger net-baryon densities and lower temperatures, it is expected that the QCD phase diagram exhibits a rich structure, such as a first-order phase transition between hadronic and partonic matter which terminates in a critical point, or exotic phases like quarkyonic matter. The discovery of these landmarks would be a breakthrough in our understanding of the strong interaction and is therefore in the focus of various high-energy heavy-ion research programs. The Compressed Baryonic Matter (CBM) experiment at FAIR will play a unique role in the exploration of the QCD phase diagram in the region of high net-baryon densities, because it is designed to run at unprecedented interaction rates. High-rate operation is the key prerequisite for high-precision measurements of multi-differential observables and of rare diagnostic probes which are sensitive to the dense phase of the nuclear fireball. The goal of the CBM experiment at SIS100 (sqrt(s_NN) = 2.7 - 4.9 GeV) is to discover fundamental properties of QCD matter: the phase structure at large baryon-chemical potentials (mu_B > 500 MeV), effects of chiral symmetry, and the equation-of-state at high density as it is expected to occur in the core of neutron stars. In this article, we review the motivation for and the physics programme of CBM, including activities before the start of data taking in 2022, in the context of the worldwide efforts to explore high-density QCD matter.
△ Less
Submitted 29 March, 2017; v1 submitted 6 July, 2016;
originally announced July 2016.
-
Time and position resolution of high granularity, high counting rate MRPC for the inner zone of the CBM-TOF wall
Authors:
M. Petriş,
D. Bartoş,
G. Caragheorgheopol,
I. Deppner,
J. Frühauf,
N. Herrmann,
M. Kiš,
P-A. Loizeau,
M. Petrovici,
L. Rǎdulescu,
V. Simion,
C. Simon
Abstract:
Multi-gap RPC prototypes with readout on a multi-strip electrode were developed for the small polar angle region of the CBM-TOF subdetector, the most demanding zone in terms of granularity and counting rate. The prototypes are based on low resistivity ($\sim$10$^{10}$ $Ω$cm) glass electrodes for performing in high counting rate environment. The strip width/pitch size was chosen such to fulfill the…
▽ More
Multi-gap RPC prototypes with readout on a multi-strip electrode were developed for the small polar angle region of the CBM-TOF subdetector, the most demanding zone in terms of granularity and counting rate. The prototypes are based on low resistivity ($\sim$10$^{10}$ $Ω$cm) glass electrodes for performing in high counting rate environment. The strip width/pitch size was chosen such to fulfill the impedance matching with the front-end electronics and the granularity requirements of the innermost zone of the CBM-TOF wall. The in-beam tests using secondary particles produced in heavy ion collisions on a Pb target at SIS18 - GSI Darmstadt and SPS - CERN were focused on the performance of the prototype in conditions similar to the ones expected at SIS100/FAIR. An efficiency larger than 98\% and a system time resolution in the order of 70~-~80~ps were obtained in high counting rate and high multiplicity environment.
△ Less
Submitted 9 May, 2016;
originally announced May 2016.