-
First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
Authors:
J. Aalbers,
D. S. Akerib,
C. W. Akerlof,
A. K. Al Musalhi,
F. Alder,
A. Alqahtani,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
S. Azadi,
A. J. Bailey,
A. Baker,
J. Balajthy,
S. Balashov,
J. Bang,
J. W. Bargemann,
M. J. Barry,
J. Barthel,
D. Bauer,
A. Baxter
, et al. (322 additional authors not shown)
Abstract:
The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dakota, USA. This Letter reports results from LUX-ZEPLIN's first search for weakly interacting massive particles (WIMPs) with an exposure of 60~live days using a fiducial mass of 5.5 t. A profile-likelihood ratio analysis s…
▽ More
The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dakota, USA. This Letter reports results from LUX-ZEPLIN's first search for weakly interacting massive particles (WIMPs) with an exposure of 60~live days using a fiducial mass of 5.5 t. A profile-likelihood ratio analysis shows the data to be consistent with a background-only hypothesis, setting new limits on spin-independent WIMP-nucleon, spin-dependent WIMP-neutron, and spin-dependent WIMP-proton cross sections for WIMP masses above 9 GeV/c$^2$. The most stringent limit is set for spin-independent scattering at 36 GeV/c$^2$, rejecting cross sections above 9.2$\times 10^{-48}$ cm$^2$ at the 90% confidence level.
△ Less
Submitted 2 August, 2023; v1 submitted 8 July, 2022;
originally announced July 2022.
-
An application of sums of triple products of binomials
Authors:
Michael J. J. Barry
Abstract:
We prove that a certain family of sums of products of three binomials has alternating behavior modulo a prime $p$. To accomplish this we rewrite these sums as signed sums of products of three binomials, the better to handle $p$, and we give closed-form expressions for two related sums of signed products of three binomials.
We prove that a certain family of sums of products of three binomials has alternating behavior modulo a prime $p$. To accomplish this we rewrite these sums as signed sums of products of three binomials, the better to handle $p$, and we give closed-form expressions for two related sums of signed products of three binomials.
△ Less
Submitted 23 February, 2022;
originally announced February 2022.
-
Generators for Decompositions of Tensor Products of Indecomposable Modules
Authors:
Michael J. J. Barry
Abstract:
Let $F$ be a field of non-zero characteristic $p$, let $G$ be a cyclic group of order $q =p^a$ for some positive integer $a$, and let $U$ and $W$ be indecomposable $F G$-modules. We identify a generator for each of the indecomposable components of $U \otimes W$ in terms of a particular $F$-basis of $U \otimes W$, extending previous work in which each component occurred with multiplicity one. An an…
▽ More
Let $F$ be a field of non-zero characteristic $p$, let $G$ be a cyclic group of order $q =p^a$ for some positive integer $a$, and let $U$ and $W$ be indecomposable $F G$-modules. We identify a generator for each of the indecomposable components of $U \otimes W$ in terms of a particular $F$-basis of $U \otimes W$, extending previous work in which each component occurred with multiplicity one. An anonymous reviewer helped us realize that our results are really just a translation of previous results of Iiwa and Iwamatsu to our situation.
△ Less
Submitted 10 January, 2022;
originally announced January 2022.
-
Set Equality in Combinatorial Game Theory
Authors:
Michael J. J. Barry
Abstract:
In Combinatorial Game Theory, the fundamental relation of game equivalence, denoted by $=$, is introduced early on and overrides the notion of set equality. We explore what happens if set equality is given its due before game equivalence is introduced.
In Combinatorial Game Theory, the fundamental relation of game equivalence, denoted by $=$, is introduced early on and overrides the notion of set equality. We explore what happens if set equality is given its due before game equivalence is introduced.
△ Less
Submitted 2 September, 2020;
originally announced September 2020.
-
The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs
Authors:
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
S. Aviles,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame,
J. Bensinger
, et al. (365 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherent…
▽ More
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and bespoke detector systems to assay scintillator are presented.
△ Less
Submitted 28 February, 2022; v1 submitted 3 June, 2020;
originally announced June 2020.
-
The Effect of Treatment-Related Deaths and "Sticky" Diagnoses on Recorded Prostate Cancer Mortality
Authors:
H. Gilbert Welch,
Michael J. Barry,
William C Black,
Yunjie Song,
Elliott S. Fisher
Abstract:
Background: Although recorded cancer mortality should include both deaths from cancer and deaths from cancer treatment, there is evidence suggesting that the measure may be incomplete. To investigate the completeness of recorded prostate cancer mortality, we compared other-cause (non-prostate cancer) mortality in men found and not found to have prostate cancer following a needle biopsy.
Methods:…
▽ More
Background: Although recorded cancer mortality should include both deaths from cancer and deaths from cancer treatment, there is evidence suggesting that the measure may be incomplete. To investigate the completeness of recorded prostate cancer mortality, we compared other-cause (non-prostate cancer) mortality in men found and not found to have prostate cancer following a needle biopsy.
Methods: We linked Medicare claims data to SEER data to analyze survival in the population of men aged 65+ enrolled in Medicare who resided in a SEER area and received a needle biopsy in 1993-2001. We compared other-cause mortality in men found to have prostate cancer (n=53,462) to that in men not found to have prostate cancer (n=103,659).
Results: The age-race adjusted other-cause mortality rate was 471 per 10,000 person-years in men found to have prostate cancer vs. 468 per 10,000 in men not found to have prostate cancer (RR = 1.01;95% CI:0.98-1.03). The effect was modified, however, by age. The RR declined in a stepwise fashion from 1.08 (95% CI:1.03-1.14) in men age 65-69 to 0.89 (95% CI:0.83-0.95) in men age 85 and older. If the excess (or deficit) in other-cause mortality were added to the recorded prostate cancer mortality, prostate cancer mortality would rise 23% in the youngest age group (from 90 to 111 per 10,000) and would fall 30% in the oldest age group (from 551 to 388 per 10,000).
Conclusion: Although recorded prostate cancer mortality appears to be an accurate measure overall, it systematically underestimates the mortality associated with prostate cancer diagnosis and treatment in younger men and overestimates it in the very old. We surmise that in younger men treatment-related deaths are incompletely captured in recorded prostate cancer mortality, while in older men the diagnosis "sticks"-- once diagnosed, they are more likely to be said to have died from the disease.
△ Less
Submitted 2 January, 2020;
originally announced January 2020.
-
The LUX-ZEPLIN (LZ) Experiment
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
J. Barthel,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame
, et al. (357 additional authors not shown)
Abstract:
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n…
▽ More
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
△ Less
Submitted 3 November, 2019; v1 submitted 20 October, 2019;
originally announced October 2019.
-
More on Periodicity and Duality associated with Jordan partitions
Authors:
Michael J. J. Barry
Abstract:
Let $J_r$ denote a full $r \times r$ Jordan block matrix with eigenvalue $1$ over a field $F$ of characteristic $p$. For positive integers $r$ and $s$ with $r \leq s$, the Jordan canonical form of the $r s \times r s$ matrix $J_{r} \otimes J_{s}$ has the form $J_{λ_1} \oplus J_{λ_2} \oplus \dots \oplus J_{λ_{r}}$ where $λ_1 \geq λ_2 \geq \dots \geq λ_{r}>0$. This decomposition determines a partiti…
▽ More
Let $J_r$ denote a full $r \times r$ Jordan block matrix with eigenvalue $1$ over a field $F$ of characteristic $p$. For positive integers $r$ and $s$ with $r \leq s$, the Jordan canonical form of the $r s \times r s$ matrix $J_{r} \otimes J_{s}$ has the form $J_{λ_1} \oplus J_{λ_2} \oplus \dots \oplus J_{λ_{r}}$ where $λ_1 \geq λ_2 \geq \dots \geq λ_{r}>0$. This decomposition determines a partition $λ(r,s,p)=(λ_1,λ_2,\dots, λ_{r})$ of $r s$, known as the \textbf{Jordan partition}, but the values of the parts depend on $r$, $s$, and $p$. Write \[(λ_1,λ_2,\dots, λ_{r})=(\overbrace{μ_1,\dots,μ_1}^{m_1},\overbrace{μ_2,\dots,μ_2}^{m_2},\dots, \overbrace{μ_k,\dots,μ_k}^{m_k}) =(m_1 \cdot μ_1, \dots,m_k \cdot μ_k),\] where $μ_1>μ_2>\dots>μ_k>0$, and denote the composition $(m_1,\dots,m_k)$ of $r$ by $c(r,s,p)$. A recent result of Glasby, Praeger, and Xia in \cite{GPX} implies that if $r \leq p^β$, $c(r,s,p)$ is periodic in the second variable $s$ with period length $p^β$ and exhibits a reflection property within that period. We determine the least period length and we exhibit new partial subperiodic and partial subreflective behavior.
△ Less
Submitted 15 July, 2019;
originally announced July 2019.
-
LUX-ZEPLIN (LZ) Technical Design Report
Authors:
B. J. Mount,
S. Hans,
R. Rosero,
M. Yeh,
C. Chan,
R. J. Gaitskell,
D. Q. Huang,
J. Makkinje,
D. C. Malling,
M. Pangilinan,
C. A. Rhyne,
W. C. Taylor,
J. R. Verbus,
Y. D. Kim,
H. S. Lee,
J. Lee,
D. S. Leonard,
J. Li,
J. Belle,
A. Cottle,
W. H. Lippincott,
D. J. Markley,
T. J. Martin,
M. Sarychev,
T. E. Tope
, et al. (237 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
△ Less
Submitted 27 March, 2017;
originally announced March 2017.
-
Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches
Authors:
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
S. K. Alsum,
H. M. Araújo,
I. J. Arnquist,
M. Arthurs,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
M. J. Barry,
J. Belle,
P. Beltrame,
T. Benson,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
K. E. Boast,
A. Bolozdynya,
B. Boxer,
R. Bramante,
P. Brás,
J. H. Buckley,
V. V. Bugaev
, et al. (180 additional authors not shown)
Abstract:
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals,…
▽ More
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals, the determination of factors limiting radiopure production, and the selection of titanium for construction of the LZ cryostat and other detector components. This titanium has been measured with activities of $^{238}$U$_{e}$~$<$1.6~mBq/kg, $^{238}$U$_{l}$~$<$0.09~mBq/kg, $^{232}$Th$_{e}$~$=0.28\pm 0.03$~mBq/kg, $^{232}$Th$_{l}$~$=0.25\pm 0.02$~mBq/kg, $^{40}$K~$<$0.54~mBq/kg, and $^{60}$Co~$<$0.02~mBq/kg (68\% CL). Such low intrinsic activities, which are some of the lowest ever reported for titanium, enable its use for future dark matter and other rare event searches. Monte Carlo simulations have been performed to assess the expected background contribution from the LZ cryostat with this radioactivity. In 1,000 days of WIMP search exposure of a 5.6-tonne fiducial mass, the cryostat will contribute only a mean background of $0.160\pm0.001$(stat)$\pm0.030$(sys) counts.
△ Less
Submitted 26 September, 2017; v1 submitted 8 February, 2017;
originally announced February 2017.
-
LUX-ZEPLIN (LZ) Conceptual Design Report
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
S. K. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
M. J. Barry,
P. Bauer,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
K. E. Boast,
A. I. Bolozdynya,
E. M. Boulton,
R. Bramante,
J. H. Buckley,
V. V. Bugaev,
R. Bunker,
S. Burdin,
J. K. Busenitz
, et al. (170 additional authors not shown)
Abstract:
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive exp…
▽ More
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive experiment for WIMPs in this mass region by the end of the decade. This report describes in detail the design of the LZ technical systems. Expected backgrounds are quantified and the performance of the experiment is presented. The LZ detector will be located at the Sanford Underground Research Facility in South Dakota. The organization of the LZ Project and a summary of the expected cost and current schedule are given.
△ Less
Submitted 23 September, 2015; v1 submitted 9 September, 2015;
originally announced September 2015.
-
Generators for Decompositions of Tensor Products of Modules associated with standard Jordan partitions
Authors:
Michael J. J. Barry
Abstract:
If $K$ is a field of finite characteristic $p$, $G$ is a cyclic group of order $q=p^α$, $U$ and $W$ are indecomposable $KG$-modules with $\dim U=m$ and $\dim W=n$, and $λ(m,n,p)$ is a standard Jordan partition of $ m n$, we describe how to find a generator for each of the indecomposable components of the $KG$-module $U \otimes W$.
If $K$ is a field of finite characteristic $p$, $G$ is a cyclic group of order $q=p^α$, $U$ and $W$ are indecomposable $KG$-modules with $\dim U=m$ and $\dim W=n$, and $λ(m,n,p)$ is a standard Jordan partition of $ m n$, we describe how to find a generator for each of the indecomposable components of the $KG$-module $U \otimes W$.
△ Less
Submitted 7 August, 2015;
originally announced August 2015.
-
On a Question of Glasby, Praeger, and Xia in Characteristic $2$
Authors:
Michael J. J. Barry
Abstract:
Recently, Glasby, Praeger, and Xia asked for necessary and sufficient conditions for the `Jordan partition' $λ(m,n,p)$ to be standard. Previously we gave such conditions when $p$ is any odd prime. Here we give such conditions when $p=2$. Our main result is that $λ(m,n,2)$ is never standard for $4 \leq m \leq n$.
Recently, Glasby, Praeger, and Xia asked for necessary and sufficient conditions for the `Jordan partition' $λ(m,n,p)$ to be standard. Previously we gave such conditions when $p$ is any odd prime. Here we give such conditions when $p=2$. Our main result is that $λ(m,n,2)$ is never standard for $4 \leq m \leq n$.
△ Less
Submitted 14 March, 2014;
originally announced March 2014.
-
On a Question of Glasby, Praeger, and Xia
Authors:
Michael J. J. Barry
Abstract:
Recently, Glasby, Praeger, and Xia asked for necessary and sufficient conditions for the `Jordan Partition' $λ(r,s,p)$ to be standard. We give such conditions when $p$ is an odd prime.
Recently, Glasby, Praeger, and Xia asked for necessary and sufficient conditions for the `Jordan Partition' $λ(r,s,p)$ to be standard. We give such conditions when $p$ is an odd prime.
△ Less
Submitted 26 February, 2014;
originally announced February 2014.
-
On Conditions Relating to Nonsolvability
Authors:
Michael J. J. Barry
Abstract:
Recent work of Kaplan and Levy refining a nonsolvability criterion proved by Thompson in his N-Groups paper prompts questions on whether certain conditions on groups are equivalent to nonsolvability.
Recent work of Kaplan and Levy refining a nonsolvability criterion proved by Thompson in his N-Groups paper prompts questions on whether certain conditions on groups are equivalent to nonsolvability.
△ Less
Submitted 22 September, 2011;
originally announced September 2011.