Rydberg Atom Electric Field Sensors as Linear Time-invariant Systems
Authors:
Neel Malvania,
Garry Jacyna,
Bonnie L. Schmittberger Marlow,
Zachary N. Hardesty-Shaw,
Kathryn L. Nicolich,
Kelly M. Backes,
Jamie L. MacLennan,
Charles T. Fancher
Abstract:
Over the past decade, Rydberg atom electric field sensors have been under investigation as potential alternatives or complements to conventional antenna-based receivers for select applications in RF communications, remote sensing, and precision metrology. To understand the potential utility of these devices for various use cases, it is crucial to develop models that accurately predict key performa…
▽ More
Over the past decade, Rydberg atom electric field sensors have been under investigation as potential alternatives or complements to conventional antenna-based receivers for select applications in RF communications, remote sensing, and precision metrology. To understand the potential utility of these devices for various use cases, it is crucial to develop models that accurately predict key performance metrics such as instantaneous bandwidth and dynamic range. However, existing numerical models require solving a large set of coupled differential equations that is computationally intensive and lengthy to solve. We present an analytic approach that can be used to derive an impulse response function that allows up to two orders-of-magnitude reduction in computation time compared to the full time-dependent integration of the equations of motion. This approach can be used to enable rapid assessments of the Rydberg sensor's response to various waveforms.
△ Less
Submitted 30 April, 2025;
originally announced May 2025.
-
Performance of Antenna-based and Rydberg Quantum RF Sensors in the Electrically Small Regime
Authors:
K. M. Backes,
P. K. Elgee,
K. -J. LeBlanc,
C. T. Fancher,
D. H. Meyer,
P. D. Kunz,
N. Malvania,
K. M. Nicolich,
J. C. Hill,
B. L. Schmittberger Marlow,
K. C. Cox
Abstract:
Rydberg atom electric field sensors are tunable quantum sensors that can perform sensitive radio frequency (RF) measurements. Their qualities have piqued interest at longer wavelengths where their small size compares favorably to impedance-matched antennas. Here, we compare the signal detection sensitivity of cm-scale Rydberg sensors to similarly sized room-temperature electrically small antennas…
▽ More
Rydberg atom electric field sensors are tunable quantum sensors that can perform sensitive radio frequency (RF) measurements. Their qualities have piqued interest at longer wavelengths where their small size compares favorably to impedance-matched antennas. Here, we compare the signal detection sensitivity of cm-scale Rydberg sensors to similarly sized room-temperature electrically small antennas with active and passive receiver backends. We present and analyze effective circuit models for each sensor type, facilitating a fair sensitivity comparison for cm-scale sensors. We calculate that contemporary Rydberg sensor implementations are less sensitive than unmatched antennas with active amplification. However, we find that idealized Rydberg sensors operating with a maximized atom number and at the standard quantum limit may perform well beyond the capabilities of antenna-based sensors at room temperature, the sensitivities of both lying below typical atmospheric background noise.
△ Less
Submitted 26 August, 2024;
originally announced August 2024.
-
New Results from HAYSTAC's Phase II Operation with a Squeezed State Receiver
Authors:
HAYSTAC Collaboration,
M. J. Jewell,
A. F. Leder,
K. M. Backes,
Xiran Bai,
K. van Bibber,
B. M. Brubaker,
S. B. Cahn,
A. Droster,
Maryam H. Esmat,
Sumita Ghosh,
Eleanor Graham,
Gene C. Hilton,
H. Jackson,
Claire Laffan,
S. K. Lamoreaux,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
R. H. Maruyama,
D. A. Palken,
N. M. Rapidis,
E. P. Ruddy,
M. Simanovskaia,
Sukhman Singh
, et al. (4 additional authors not shown)
Abstract:
A search for dark matter axions with masses $>10 μeV/c^{2}$ has been performed using the HAYSTAC experiment's squeezed state receiver to achieve sub-quantum limited noise. This report includes details of the design and operation of the experiment previously used to search for axions in the mass ranges $16.96-17.12$ and $17.14-17.28 μeV/c^{2}$($4.100-4.140$GHz) and $4.145-4.178$GHz) as well as upgr…
▽ More
A search for dark matter axions with masses $>10 μeV/c^{2}$ has been performed using the HAYSTAC experiment's squeezed state receiver to achieve sub-quantum limited noise. This report includes details of the design and operation of the experiment previously used to search for axions in the mass ranges $16.96-17.12$ and $17.14-17.28 μeV/c^{2}$($4.100-4.140$GHz) and $4.145-4.178$GHz) as well as upgrades to facilitate an extended search at higher masses. These upgrades include improvements to the data acquisition routine which have reduced the effective dead time by a factor of 5, allowing for the new region to be scanned $\sim$1.6 times faster with comparable sensitivity. No statistically significant evidence of an axion signal is found in the range $18.44-18.71μeV/c^{2}$($4.459-4.523$GHz), leading to an aggregate upper limit exclusion at the $90\%$ level on the axion-photon coupling of $2.06\times g_γ^{KSVZ}$.
△ Less
Submitted 26 January, 2023; v1 submitted 23 January, 2023;
originally announced January 2023.
-
A quantum-enhanced search for dark matter axions
Authors:
K. M. Backes,
D. A. Palken,
S. Al Kenany,
B. M. Brubaker,
S. B. Cahn,
A. Droster,
Gene C. Hilton,
Sumita Ghosh,
H. Jackson,
S. K. Lamoreaux,
A. F. Leder,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
R. H. Maruyama,
N. M. Rapidis,
M. Simanovskaia,
Sukhman Singh,
D. H. Speller,
I. Urdinaran,
Leila R. Vale,
E. C. van Assendelft,
K. van Bibber,
H. Wang
Abstract:
In dark matter axion searches, quantum uncertainty manifests as a fundamental noise source, limiting the measurement of the quadrature observables used for detection. We use vacuum squeezing to circumvent the quantum limit in a search for a new particle. By preparing a microwave-frequency electromagnetic field in a squeezed state and near-noiselessly reading out only the squeezed quadrature, we do…
▽ More
In dark matter axion searches, quantum uncertainty manifests as a fundamental noise source, limiting the measurement of the quadrature observables used for detection. We use vacuum squeezing to circumvent the quantum limit in a search for a new particle. By preparing a microwave-frequency electromagnetic field in a squeezed state and near-noiselessly reading out only the squeezed quadrature, we double the search rate for axions over a mass range favored by recent theoretical projections. We observe no signature of dark matter axions in the combined $16.96-17.12$ and $17.14-17.28\spaceμ\text{eV}/c^2$ mass window for axion-photon couplings above $g_γ = 1.38\times g_γ^\text{KSVZ}$, reporting exclusion at the 90% level.
△ Less
Submitted 4 August, 2020;
originally announced August 2020.
-
An improved analysis framework for axion dark matter searches
Authors:
D. A. Palken,
B. M. Brubaker,
M. Malnou,
S. Al Kenany,
K. M. Backes,
S. B. Cahn,
Y. V. Gurevich,
S. K. Lamoreaux,
S. M. Lewis,
R. H. Maruyama,
N. M. Rapidis,
J. R. Root,
M. Simanovskaia,
T. M. Shokair,
Sukhman Singh,
D. H. Speller,
I. Urdinaran,
K. van Bibber,
L. Zhong,
K. W. Lehnert
Abstract:
In experiments searching for axionic dark matter, the use of the standard threshold-based data analysis discards valuable information. We present a Bayesian analysis framework that builds on an existing processing protocol to extract more information from the data of coherent axion detectors such as operating haloscopes. The analysis avoids logical subtleties that accompany the standard analysis f…
▽ More
In experiments searching for axionic dark matter, the use of the standard threshold-based data analysis discards valuable information. We present a Bayesian analysis framework that builds on an existing processing protocol to extract more information from the data of coherent axion detectors such as operating haloscopes. The analysis avoids logical subtleties that accompany the standard analysis framework and enables greater experimental flexibility on future data runs. Performing this analysis on the existing data from the HAYSTAC experiment, we find improved constraints on the axion-photon coupling $g_γ$ while also identifying the most promising regions of parameter space within the $23.15$--$24.0$ $μ$eV mass range. A comparison with the standard threshold analysis suggests a $36\%$ improvement in scan rate from our analysis, demonstrating the utility of this framework for future axion haloscope analyses.
△ Less
Submitted 28 July, 2020; v1 submitted 18 March, 2020;
originally announced March 2020.
-
Results from phase 1 of the HAYSTAC microwave cavity axion experiment
Authors:
L. Zhong,
S. Al Kenany,
K. M. Backes,
B. M. Brubaker,
S. B. Cahn,
G. Carosi,
Y. V. Gurevich,
W. F. Kindel,
S. K. Lamoreaux,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
R. H. Maruyama,
D. A. Palken,
N. M. Rapidis,
J. R. Root,
M. Simanovskaia,
T. M. Shokair,
D. H. Speller,
I. Urdinaran,
K. A. van Bibber
Abstract:
We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6-5.8$\, \rm Ghz$. We exclude axion models with two photon coupling $g_{aγγ}\,\gtrsim\,2\times10^{-14}\,\rm GeV^{-1}$, a factor of 2.7 above the benchmark KSVZ model over the mass range 23.15$\,<\,$$m_a \,$<$\,$24.0$\,μ\rm eV$. This doubles the range…
▽ More
We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6-5.8$\, \rm Ghz$. We exclude axion models with two photon coupling $g_{aγγ}\,\gtrsim\,2\times10^{-14}\,\rm GeV^{-1}$, a factor of 2.7 above the benchmark KSVZ model over the mass range 23.15$\,<\,$$m_a \,$<$\,$24.0$\,μ\rm eV$. This doubles the range reported in our previous paper. We achieve a near-quantum-limited sensitivity by operating at a temperature $T<hν/2k_B$ and incorporating a Josephson parametric amplifier (JPA), with improvements in the cooling of the cavity further reducing the experiment's system noise temperature to only twice the Standard Quantum Limit at its operational frequency, an order of magnitude better than any other dark matter microwave cavity experiment to date. This result concludes the first phase of the HAYSTAC program utilizing a conventional copper cavity and a single JPA.
△ Less
Submitted 9 March, 2018;
originally announced March 2018.
-
Design and Operational Experience of a Microwave Cavity Axion Detector for the 20-100 micro-eV Range
Authors:
S. Al Kenany,
M. A. Anil,
K. M. Backes,
B. M. Brubaker,
S. B. Cahn,
G. Carosi,
Y. V. Gurevich,
W. F. Kindel,
S. K. Lamoreaux,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
D. A. Palken,
N. M. Rapidis,
J. R. Root,
M. Simanovskaia,
T. M. Shokair,
I. Urdinaran,
K. A. van Bibber,
L. Zhong
Abstract:
We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: μ$eV). The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently comple…
▽ More
We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: μ$eV). The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently completed its first data production; it is the first microwave cavity axion search to deploy a Josephson parametric amplifier and a dilution refrigerator to achieve near-quantum limited performance.
△ Less
Submitted 22 February, 2017; v1 submitted 21 November, 2016;
originally announced November 2016.
-
First results from a microwave cavity axion search at 24 micro-eV
Authors:
B. M. Brubaker,
L. Zhong,
Y. V. Gurevich,
S. B. Cahn,
S. K. Lamoreaux,
M. Simanovskaia,
J. R. Root,
S. M. Lewis,
S. Al Kenany,
K. M. Backes,
I. Urdinaran,
N. M. Rapidis,
T. M. Shokair,
K. A. van Bibber,
D. A. Palken,
M. Malnou,
W. F. Kindel,
M. A. Anil,
K. W. Lehnert,
G. Carosi
Abstract:
We report on the first results from a new microwave cavity search for dark matter axions with masses above $20~μ\text{eV}$. We exclude axion models with two-photon coupling $g_{aγγ} \gtrsim 2\times10^{-14}~\text{GeV}^{-1}$ over the range $23.55~μ\text{eV} < m_a < 24.0~μ\text{eV}$. These results represent two important achievements. First, we have reached cosmologically relevant sensitivity an orde…
▽ More
We report on the first results from a new microwave cavity search for dark matter axions with masses above $20~μ\text{eV}$. We exclude axion models with two-photon coupling $g_{aγγ} \gtrsim 2\times10^{-14}~\text{GeV}^{-1}$ over the range $23.55~μ\text{eV} < m_a < 24.0~μ\text{eV}$. These results represent two important achievements. First, we have reached cosmologically relevant sensitivity an order of magnitude higher in mass than any existing limits. Second, by incorporating a dilution refrigerator and Josephson parametric amplifier, we have demonstrated total noise approaching the standard quantum limit for the first time in an axion search.
△ Less
Submitted 9 February, 2017; v1 submitted 8 October, 2016;
originally announced October 2016.