Recent and Upcoming Upgrades for MIRC-X and MYSTIC on the CHARA Array
Authors:
Noura Ibrahim,
Mayra Gutierrez,
John D. Monnier,
Stefan Kraus,
Jean-Baptiste Le Bouquin,
Narsireddy Anugu,
Theo ten Brummelaar,
Sorabh Chhabra,
Isabelle Codron,
Julien Dejonghe,
Aaron Labdon,
Daniel Lecron,
Daniel Mortimer,
Denis Mourard,
Gail Schaefer,
Benjamin Setterholm,
Manuela Arnó,
Andrea Bianco,
Michele Frangiamore,
Laurent Jocou
Abstract:
MIRC-X and MYSTIC are six-telescope near-infrared beam (1.08-2.38 $μ$m) combiners at the CHARA Array on Mt Wilson CA, USA. Ever since the commissioning of MIRC-X (J and H bands) in 2018 and MYSTIC (K bands) in 2021, they have been the most popular and over-subscribed instruments at the array. Observers have been able to image stellar objects with sensitivity down to 8.1 mag in H and 7.8 mag in K-b…
▽ More
MIRC-X and MYSTIC are six-telescope near-infrared beam (1.08-2.38 $μ$m) combiners at the CHARA Array on Mt Wilson CA, USA. Ever since the commissioning of MIRC-X (J and H bands) in 2018 and MYSTIC (K bands) in 2021, they have been the most popular and over-subscribed instruments at the array. Observers have been able to image stellar objects with sensitivity down to 8.1 mag in H and 7.8 mag in K-band under the very best conditions. In 2022 MYSTIC was upgraded with a new ABCD mode using the VLTI/GRAVITY 4-beam integrated optics chip, with the goal of improving the sensitivity and calibration. The ABCD mode has been used to observe more than 20 T Tauri stars; however, the data pipeline is still being developed. Alongside software upgrades, we detail planned upgrades to both instruments in this paper. The main upgrades are: 1) Adding a motorized filter wheel to MIRC-X along with new high spectral resolution modes 2) Updating MIRC-X optics to allow for simultaneous 6T J+H observations 3) Removing the warm window between the spectrograph and the warm optics in MYSTIC 4) Adding a 6T ABCD mode to MIRC-X in collaboration with CHARA/SPICA 5) Updating the MIRC-X CRED-ONE camera funded by Prof. Kraus from U. Exeter 6) Carrying out science verification of the MIRC-X polarization mode 7) Developing new software for ABCD-mode data reduction and more efficient calibration routines. We expect these upgrades to not only improve the observing experience, but also increase the sensitivity by 0.4 mag in J+H-bands, and 1 mag in K-band.
△ Less
Submitted 7 August, 2024;
originally announced August 2024.
Anisotropic polymer nanoparticles with controlled dimensions from the morphological transformation of isotropic seeds
Authors:
Zan Hua,
Joseph R Jones,
Marjolaine Thomas,
Maria C Arno,
Anton Souslov,
Thomas R Wilks,
Rachel K O'Reilly
Abstract:
Understanding and controlling self-assembly processes at multiple length scales is vital if we are to design and create advanced materials. In particular, our ability to organise matter on the nanoscale has advanced considerably, but still lags far behind our skill in manipulating individual molecules. New tools allowing controlled nanoscale assembly are sorely needed, as well as the physical unde…
▽ More
Understanding and controlling self-assembly processes at multiple length scales is vital if we are to design and create advanced materials. In particular, our ability to organise matter on the nanoscale has advanced considerably, but still lags far behind our skill in manipulating individual molecules. New tools allowing controlled nanoscale assembly are sorely needed, as well as the physical understanding of how they work. Here, we report a new method for the production of highly anisotropic nanoparticles with controlled dimensions based on a morphological transformation process (MORPH for short) driven by the formation of supramolecular bonds. We present a minimal physical model for MORPH which suggests it will be generalisable to a large number of polymer/nanoparticle systems. We envision MORPH becoming a valuable tool for controlling nanoscale self-assembly, and for the production of functional nanostructures for diverse applications.
△ Less
Submitted 2 October, 2019;
originally announced October 2019.
More Mouldy Data: Another mycoplasma gene jumps the silicon barrier into the human genome
Authors:
W. B. Langdon,
M. J. Arno
Abstract:
The human genome sequence database contains DNA sequences very like those of mycoplasma molds. It appears such moulds infect not only molecular Biology laboratories but were picked up by experimenters from contaminated samples and inserted into GenBank as if they were human. At least one mouldy EST (Expressed Sequence Tag) has transferred from public databases to commercial tools (Affymetrix HG-U1…
▽ More
The human genome sequence database contains DNA sequences very like those of mycoplasma molds. It appears such moulds infect not only molecular Biology laboratories but were picked up by experimenters from contaminated samples and inserted into GenBank as if they were human. At least one mouldy EST (Expressed Sequence Tag) has transferred from public databases to commercial tools (Affymetrix HG-U133 plus 2.0 microarrays). We report a second example (DA466599) and suggest there is a need to clean up genomic databases but fear current tools will be inadequate to catch genes which have jumped the silicon barrier.
△ Less
Submitted 21 June, 2011;
originally announced June 2011.