-
Next Generation Multi-element monolithic Germanium detectors for Spectroscopy: First integration at ESRF facility
Authors:
N. Goyal,
S. Aplin,
A. Balerna,
P. Bell,
J. Casas,
M. Cascella,
S. Chatterji,
C. Cohen,
E. Collet,
P. Fajardo,
E. N. Gimenez,
H. Graafsma,
H. Hiresmann,
F. J. Iguaz,
K. Klementiev,
T. Kolodziej,
L. Manzanillas,
T. Martin,
R. H. Menk,
M. Porro,
M. Quispe,
B. Schmitt,
S. Scully,
M. Turcato,
C. Ward
, et al. (1 additional authors not shown)
Abstract:
The XAFS-DET work package of the European LEAPS-INNOV project is developing a high-purity Germanium detectors for synchrotron applications requiring spectroscopic-grade response. The detectors integrate three key features: (1) newly designed monolithic Germanium sensors optimised to mitigate charge-sharing events, (2) an improved cooling and mechanical design structure supported by thermal simulat…
▽ More
The XAFS-DET work package of the European LEAPS-INNOV project is developing a high-purity Germanium detectors for synchrotron applications requiring spectroscopic-grade response. The detectors integrate three key features: (1) newly designed monolithic Germanium sensors optimised to mitigate charge-sharing events, (2) an improved cooling and mechanical design structure supported by thermal simulations, and (3) complete electronic chain featuring a low-noise CMOS technology-based preamplifier. enabling high X-ray count rate capability over a broad energy range (5-100 keV). This paper discusses the first integration and characterization of one of the two multi-element Ge detectors at the European Synchrotron Radiation Facility (ESRF). The integration phase included validating high-throughput front-End electronics, integrating them with the Ge sensor, and operating them at liquid nitrogen temperature, in addition to the experimental characterization, which consists of electronics noise study and spectroscopic performance evaluation.
△ Less
Submitted 23 April, 2025;
originally announced April 2025.
-
Progress in the Development of Multi-Element Monolithic Germanium Detectors in LEAPS-INNOV Project: Insights from Detector Performance Simulation
Authors:
N. Goyal,
S. Aplin,
A. Balerna,
P. Bell,
J. Casas,
M. Cascella,
S. Chatterji,
C. Cohen,
E. Collet,
G. Dennis,
P. Fajardo,
E. N. Gimenez,
H. Graafsma,
H. Hiresmann,
F. J. Iguaz,
K. Klementiev,
T. Kolodziej,
L. Manzanillas,
T. Martin,
R. H. Menk,
M. Porro,
M. Quispe,
B. Schmitt,
S. Scully,
M. Turcato
, et al. (2 additional authors not shown)
Abstract:
This study presents a detailed simulation-based analysis of the detection limits of multi-element monolithic Germanium (Ge) detectors to cadmium traces in environmental soil samples. Using the capabilities of the Geant4 Monte Carlo toolkit in combination with the Solid State Detector Package, we evaluated the detection limit variation with the sample-to-detector distances and photon flux. These si…
▽ More
This study presents a detailed simulation-based analysis of the detection limits of multi-element monolithic Germanium (Ge) detectors to cadmium traces in environmental soil samples. Using the capabilities of the Geant4 Monte Carlo toolkit in combination with the Solid State Detector Package, we evaluated the detection limit variation with the sample-to-detector distances and photon flux. These simulations were conducted to mimic realistic conditions, with a photon flux measured by the SAMBA beamline at the SOLEIL synchrotron facility. Our findings for the detection limit for trace amounts of pollutants in low concentrations like cadmium in the soil provide valuable insights for optimizing experimental setups in environmental monitoring and synchrotron-based applications, where precise detection of trace elements is critical.
△ Less
Submitted 20 April, 2025;
originally announced April 2025.
-
On the use of multilayer Laue lenses with X-ray Free Electron Lasers
Authors:
Mauro Prasciolu,
Kevin T. Murray,
Nikolay Ivanov,
Holger Fleckenstein,
Martin Domaracký,
Luca Gelisio,
Fabian Trost,
Kartik Ayyer,
Dietrich Krebs,
Steve Aplin,
Salah Awel,
Ulrike Boesenberg,
Anton Barty,
Armando D. Estillore,
Matthias Fuchs,
Yaroslav Gevorkov,
Joerg Hallmann,
Chan Kim,
Juraj Knoška,
Jochen Küpper,
Chufeng Li,
Wei Lu,
Valerio Mariani,
Andrew J. Morgan,
Johannes Möller
, et al. (12 additional authors not shown)
Abstract:
Multilayer Laue lenses were used for the first time to focus x-rays from an X-ray Free Electron Laser (XFEL). In an experiment, which was performed at the European XFEL, we demonstrated focusing to a spot size of a few tens of nanometers. A series of runs in which the number of pulses per train was increased from 1 to 2, 3, 4, 5, 6, 7, 10, 20 and 30 pulses per train, all with a pulse separation of…
▽ More
Multilayer Laue lenses were used for the first time to focus x-rays from an X-ray Free Electron Laser (XFEL). In an experiment, which was performed at the European XFEL, we demonstrated focusing to a spot size of a few tens of nanometers. A series of runs in which the number of pulses per train was increased from 1 to 2, 3, 4, 5, 6, 7, 10, 20 and 30 pulses per train, all with a pulse separation of 3.55 us, was done using the same set of lenses. The increase in the number of pulses per train was accompanied with an increase of x-ray intensity (transmission) from 9% to 92% at 5 pulses per train, and then the transmission was reduced to 23.5 % when the pulses were increased further. The final working condition was 30 pulses per train and 23.5% transmission. Only at this condition we saw that the diffraction efficiency of the MLLs changed over the course of a pulse train, and this variation was reproducible from train to train. We present the procedure to align and characterize these lenses and discuss challenges working with the pulse trains from this unique x-ray source.
△ Less
Submitted 22 March, 2022;
originally announced March 2022.
-
Ptychographic X-ray Speckle Tracking with Multi Layer Laue Lens Systems
Authors:
Andrew James Morgan,
Kevin T. Murray,
Mauro Prasciolu,
Holger Fleckenstein,
Oleksandr Yefanov,
Pablo Villanueva-Perez,
Valerio Mariani,
Martin Domaracky,
Manuela Kuhn,
Steve Aplin,
Istwan Mohacsi,
Marc Messerschmidt,
Karolina Stachnik,
Yang Du,
Anja Burkhart,
Alke Meents,
Evgeny Nazaretski,
Hanfei Yan,
Xiaojing Huang,
Yong Chu,
Henry N. Chapman,
Saša Bajt
Abstract:
The ever-increasing brightness of synchrotron radiation sources demands improved x-ray optics to utilise their capability for imaging and probing biological cells, nano-devices, and functional matter on the nanometre scale with chemical sensitivity. Hard x-rays are ideal for high-resolution imaging and spectroscopic applications due to their short wavelength, high penetrating power, and chemical s…
▽ More
The ever-increasing brightness of synchrotron radiation sources demands improved x-ray optics to utilise their capability for imaging and probing biological cells, nano-devices, and functional matter on the nanometre scale with chemical sensitivity. Hard x-rays are ideal for high-resolution imaging and spectroscopic applications due to their short wavelength, high penetrating power, and chemical sensitivity. The penetrating power that makes x-rays useful for imaging also makes focusing them technologically challenging. Recent developments in layer deposition techniques that have enabled the fabrication of a series of highly focusing x-ray lenses, known as wedged multi layer Laue lenses. Improvements to the lens design and fabrication technique demands an accurate, robust, in-situ and at-wavelength characterisation method. To this end, we have developed a modified form of the speckle-tracking wavefront metrology method, the ptychographic x-ray speckle tracking method, which is capable of operating with highly divergent wavefields. A useful by-product of this method, is that it also provides high-resolution and aberration-free projection images of extended specimens. We report on three separate experiments using this method, where we have resolved ray path angles to within 4 nano-radians with an imaging resolution of 45nm (full-period). This method does not require a high degree of coherence, making it suitable for lab based x-ray sources. Likewise it is robust to errors in the registered sample positions making it suitable for x-ray free-electron laser facilities, where beam pointing fluctuations can be problematic for wavefront metrology.
△ Less
Submitted 28 March, 2020;
originally announced March 2020.
-
Forward tracking at the next \boldmath{$e^+e^-$} collider Part II: experimental challenges and detector design
Authors:
Steve Aplin,
Marça Boronat,
Dominik Dannheim,
Jordi Duarte,
F. Gaede,
Alberto Ruiz-Jimeno,
Andre Sailer,
Manfred Valentan,
Ivan Vila,
Marcel Vos
Abstract:
We present the second in a series of studies into the forward tracking system for a future linear $ e^+ e^- $ collider with a center-of-mass energy in the range from 250 GeV to 3 TeV. In this note a number of specific challenges are investigated, that have caused a degradation of the tracking and vertexing performance in the forward region in previous experiments. We perform a quantitative analysi…
▽ More
We present the second in a series of studies into the forward tracking system for a future linear $ e^+ e^- $ collider with a center-of-mass energy in the range from 250 GeV to 3 TeV. In this note a number of specific challenges are investigated, that have caused a degradation of the tracking and vertexing performance in the forward region in previous experiments. We perform a quantitative analysis of the dependence of the tracking performance on detector design parameters and identify several ways to mitigate the performance loss for charged particles emitted at shallow angle.
△ Less
Submitted 26 March, 2013; v1 submitted 13 March, 2013;
originally announced March 2013.
-
Infrastructure for Detector Research and Development towards the International Linear Collider
Authors:
J. Aguilar,
P. Ambalathankandy,
T. Fiutowski,
M. Idzik,
Sz. Kulis,
D. Przyborowski,
K. Swientek,
A. Bamberger,
M. Köhli,
M. Lupberger,
U. Renz,
M. Schumacher,
Andreas Zwerger,
A. Calderone,
D. G. Cussans,
H. F. Heath,
S. Mandry,
R. F. Page,
J. J. Velthuis,
D. Attié,
D. Calvet,
P. Colas,
X. Coppolani,
Y. Degerli,
E. Delagnes
, et al. (252 additional authors not shown)
Abstract:
The EUDET-project was launched to create an infrastructure for developing and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infras…
▽ More
The EUDET-project was launched to create an infrastructure for developing and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.
△ Less
Submitted 23 January, 2012;
originally announced January 2012.