-
The Two-Phase, Two-Velocity Ionized Absorber in the Seyfert 1 Galaxy NGC 5548
Authors:
M. Andrade-Velázquez,
Y. Krongold,
M. Elvis,
F. Nicastro,
N. Brickhouse,
L. Binette,
S. Mathur,
E. Jiménez-Bailón
Abstract:
We present an analysis of X-ray high quality grating spectra of the Seyfert 1 galaxy NGC 5548 using archival Chandra HETGS and LETGS observations for a total exposure time of 800ks. The continuum emission is well represented by a powerlaw plus a black-body component. We find that the well known X-ray warm absorber in this source consists of two different outflow velocity systems. Recognizing the…
▽ More
We present an analysis of X-ray high quality grating spectra of the Seyfert 1 galaxy NGC 5548 using archival Chandra HETGS and LETGS observations for a total exposure time of 800ks. The continuum emission is well represented by a powerlaw plus a black-body component. We find that the well known X-ray warm absorber in this source consists of two different outflow velocity systems. Recognizing the presence of these kinematically distinct components allows each system to be fitted independently, each with two absorption components with different ionization levels. The high velocity system consists of a component with temperature of 2.7X10^6K and another component with temperature of 5.8X10^5K. The low-velocity system required also two absorbing components, one with temperature of 5.8X10^5K; the other with lower temperature (3.5X10^4K). Once these components are considered, the data do not require any further absorbers. In particular, a model consisting of a continuous radial range of ionization structures is not required. The two absorbing components in each velocity system are in pressure equilibrium with each other. This suggests that each velocity system consists of a multi-phase medium. This is the first time that different outflow velocity systems have been modelled independently in the X-ray band for this source. The kinematic components and column densities found from the X-rays are in agreement with the main kinematic components found in the UV absorber. This supports the idea that the UV and X-ray absorbing gas is part of the same phenomenon. NGC 5548 can now be seen to fit in a pattern established for other warm absorbers: 2 or 3 discrete phases in pressure equilibrium. There are no remaining cases of a well studied warm absorber in which a model consisting of a multi-phase medium is not viable.
△ Less
Submitted 27 January, 2010;
originally announced January 2010.
-
Suzaku Monitoring of the Seyfert 1 Galaxy NGC5548: Warm Absorber Location and its Implication for Cosmic Feedback
Authors:
Y. Krongold,
M. Elvis,
M. Andrade-Velazquez,
F. Nicastro,
S. Mathur,
J. N. Reeves,
N. S. Brickhouse,
L. Binette,
E. Jimenez-Bailon,
D. Grupe,
Y. Liu,
I. M. McHardy,
T. Minezaki,
Y. Yoshii,
B. Wilkes
Abstract:
(Abridged) We present a two month Suzaku X-ray monitoring of the Seyfert 1 galaxy NGC 5548. The campaign consists of 7 observations. We analyze the response in the opacity of the gas that forms the ionized absorber to ionizing flux variations. Despite variations by a factor of 4 in the impinging continuum, the soft X-ray spectra of the source show little spectral variations, suggesting no respon…
▽ More
(Abridged) We present a two month Suzaku X-ray monitoring of the Seyfert 1 galaxy NGC 5548. The campaign consists of 7 observations. We analyze the response in the opacity of the gas that forms the ionized absorber to ionizing flux variations. Despite variations by a factor of 4 in the impinging continuum, the soft X-ray spectra of the source show little spectral variations, suggesting no response from the ionized absorber. A detailed time modeling confirms the lack of opacity variations for an absorbing component with high ionization. Instead, the models tentatively suggest that the ionization parameter of a low ionization absorbing component might be changing with the ionizing flux, as expected for gas in photoionization equilibrium. Using the lack of variations, we set an upper limit of n_e <2.0E7 cm-3 for the electron density of the gas forming the high ionization, high velocity component. This implies a large distance from the continuum source (R > 0.033 pc). If the variations in the low ionization component are real, they imply n_e >9.8E4 cm-3 and R < 3 pc. We discuss our results in terms of two different scenarios: a large scale outflow originating in the inner parts of the accretion disk, or a thermally driven wind originating much farther out. Given the large distance of the wind, the implied mass outflow rate is also large (Mw > 0.08 Maccr). The associated total kinetic energy deployed by the wind in the host galaxy (>1.2E56 erg) can be enough to disrupt the interstellar medium, possibly regulating large scale star formation. The total mass and energy ejected by the wind is still lower than the one required for cosmic feedback, even when extrapolated to quasar luminosities. Such feedback would require that we are observing the wind before it is fully accelerated.
△ Less
Submitted 8 January, 2010;
originally announced January 2010.
-
XMM-Newton View of the Multi-Phase Warm Absorber in Seyfert 1 Galaxy NGC985
Authors:
Yair Krongold,
Elena Jimenez-Bailon,
Maria Santos-Lleo,
Fabrizio Nicastro,
Martin Elvis,
Nancy Brickhouse,
Mercedes Andrade-Velazquez,
Luc Binette,
Smita Mathur
Abstract:
We present an analysis of an XMM-Newton observation of the Seyfert 1 Galaxy NGC 985. The EPIC spectra present strong residuals to a single power-law model, indicating the presence of ionized absorbing gas and a soft excess. A broad-band fit to the EPIC and RGS spectra shows that the continuum can be well fit with a power-law and a blackbody component. The RGS can be modeled either with two or th…
▽ More
We present an analysis of an XMM-Newton observation of the Seyfert 1 Galaxy NGC 985. The EPIC spectra present strong residuals to a single power-law model, indicating the presence of ionized absorbing gas and a soft excess. A broad-band fit to the EPIC and RGS spectra shows that the continuum can be well fit with a power-law and a blackbody component. The RGS can be modeled either with two or three absorption components. In the two absorber model the low-ionization one, accounts for the presence of the Fe M-shell unresolved transition array (Fe VII-XIII), and the high ionization component is required by the presence of several Fe L-shell transitions. The data suggest the presence of a third ionized component with higher ionization, so that the Fe L-shell absorption features are produced by two different components (one producing absorption by Fe XVII-XX, and the other absorption by Fe XX-XXII). However, the presence of the third absorbing component cannot be detected by means of an isolated absorption line in a significant way, so we consider this detection only as tentative. Interestingly, all ionization components have similar kinematics. In addition, whether two or three absorbers are considered, the components appear to be in pressure balance. These results give further support to the idea that warm absorbers in AGN consist of a two or three-phase medium. We note that, while in the model with only two absorbers one of them (the high ionization component) lies on an unstable branch of the thermal equilibrium curve, in the model with three absorbers all of the components lie on stable branches of the curve. This gives further plausibility to a multi-phase absorber.
△ Less
Submitted 9 September, 2008;
originally announced September 2008.