-
Go-Smart: Open-Ended, Web-Based Modelling of Minimally Invasive Cancer Treatments via a Clinical Domain Approach
Authors:
Phil Weir,
Roland Ellerweg,
Stephen Payne,
Dominic Reuter,
Tuomas Alhonnoro,
Philip Voglreiter,
Panchatcharam Mariappan,
Mika Pollari,
Chang Sub Park,
Peter Voigt,
Tim van Oostenbrugge,
Sebastian Fischer,
Peter Kalmar,
Jurgen Futterer,
Philipp Stiegler,
Stephan Zangos,
Ronan Flanagan,
Michael Moche,
Marina Kolesnik
Abstract:
Clinicians benefit from online treatment planning systems, through off-site accessibility, data sharing and professional interaction. As well as enhancing clinical value, incorporation of simulation tools affords innovative avenues for open-ended, multi-disciplinary research collaboration. An extensible system for clinicians, technicians, manufacturers and researchers to build on a simulation fram…
▽ More
Clinicians benefit from online treatment planning systems, through off-site accessibility, data sharing and professional interaction. As well as enhancing clinical value, incorporation of simulation tools affords innovative avenues for open-ended, multi-disciplinary research collaboration. An extensible system for clinicians, technicians, manufacturers and researchers to build on a simulation framework is presented. This is achieved using a domain model that relates entities from theoretical, engineering and clinical domains, allowing algorithmic generation of simulation configuration for several open source solvers.
The platform is applied to Minimally Invasive Cancer Treatments (MICTs), allowing interventional radiologists to upload patient data, segment patient images and validate simulated treatments of radiofrequency ablation, cryoablation, microwave ablation and irreversible electroporation. A traditional radiology software layout is provided in-browser for clinical use, with simple, guided simulation, primarily for training and research. Developers and manufacturers access a web-based system to manage their own simulation components (equipment, numerical models and clinical protocols) and related parameters.
This system is tested by interventional radiologists at four centres, using pseudonymized patient data, as part of the Go-Smart Project (http://gosmart-project.eu). The simulation technology is released as a set of open source components http://github.com/go-smart.
△ Less
Submitted 24 March, 2018;
originally announced March 2018.
-
Interactive Volumetry Of Liver Ablation Zones
Authors:
Jan Egger,
Harald Busse,
Philipp Brandmaier,
Daniel Seider,
Matthias Gawlitza,
Steffen Strocka,
Philip Voglreiter,
Mark Dokter,
Michael Hofmann,
Bernhard Kainz,
Alexander Hann,
Xiaojun Chen,
Tuomas Alhonnoro,
Mika Pollari,
Dieter Schmalstieg,
Michael Moche
Abstract:
Percutaneous radiofrequency ablation (RFA) is a minimally invasive technique that destroys cancer cells by heat. The heat results from focusing energy in the radiofrequency spectrum through a needle. Amongst others, this can enable the treatment of patients who are not eligible for an open surgery. However, the possibility of recurrent liver cancer due to incomplete ablation of the tumor makes pos…
▽ More
Percutaneous radiofrequency ablation (RFA) is a minimally invasive technique that destroys cancer cells by heat. The heat results from focusing energy in the radiofrequency spectrum through a needle. Amongst others, this can enable the treatment of patients who are not eligible for an open surgery. However, the possibility of recurrent liver cancer due to incomplete ablation of the tumor makes post-interventional monitoring via regular follow-up scans mandatory. These scans have to be carefully inspected for any conspicuousness. Within this study, the RF ablation zones from twelve post-interventional CT acquisitions have been segmented semi-automatically to support the visual inspection. An interactive, graph-based contouring approach, which prefers spherically shaped regions, has been applied. For the quantitative and qualitative analysis of the algorithm's results, manual slice-by-slice segmentations produced by clinical experts have been used as the gold standard (which have also been compared among each other). As evaluation metric for the statistical validation, the Dice Similarity Coefficient (DSC) has been calculated. The results show that the proposed tool provides lesion segmentation with sufficient accuracy much faster than manual segmentation. The visual feedback and interactivity make the proposed tool well suitable for the clinical workflow.
△ Less
Submitted 21 October, 2015;
originally announced December 2015.
-
Go-Smart: Web-based Computational Modeling of Minimally Invasive Cancer Treatments
Authors:
Phil Weir,
Dominic Reuter,
Roland Ellerweg,
Tuomas Alhonnoro,
Mika Pollari,
Philip Voglreiter,
Panchatcharam Mariappan,
Ronan Flanagan,
Chang Sub Park,
Stephen Payne,
Elmar Staerk,
Peter Voigt,
Michael Moche,
Marina Kolesnik
Abstract:
The web-based Go-Smart environment is a scalable system that allows the prediction of minimally invasive cancer treatment. Interventional radiologists create a patient-specific 3D model by semi-automatic segmentation and registration of pre-interventional CT (Computed Tomography) and/or MRI (Magnetic Resonance Imaging) images in a 2D/3D browser environment. This model is used to compare patient-sp…
▽ More
The web-based Go-Smart environment is a scalable system that allows the prediction of minimally invasive cancer treatment. Interventional radiologists create a patient-specific 3D model by semi-automatic segmentation and registration of pre-interventional CT (Computed Tomography) and/or MRI (Magnetic Resonance Imaging) images in a 2D/3D browser environment. This model is used to compare patient-specific treatment plans and device performance via built-in simulation tools. Go-Smart includes evaluation techniques for comparing simulated treatment with real ablation lesions segmented from follow-up scans. The framework is highly extensible, allowing manufacturers and researchers to incorporate new ablation devices, mathematical models and physical parameters.
△ Less
Submitted 12 November, 2015; v1 submitted 11 November, 2015;
originally announced November 2015.