-
Laser patterned diamond electrodes for adhesion and proliferation of human mesenchymal stem cells
Authors:
Hassan N. Al Hashem,
Amanda N. Abraham,
Deepak Sharma,
Andre Chambers,
Mehrnoosh Moghaddar,
Chayla L. Reeves,
Sanjay K. Srivastava,
Amy Gelmi,
Arman Ahnood
Abstract:
The ability to form diamond electrodes on insulating polycrystalline diamond substrates using single-step laser patterning, and the use of the electrodes as a substrate that supports the adhesion and proliferation of human mesenchymal stem cells (hMSCs) is demonstrated. Laser induced graphitisation results in a conductive amorphous carbon surface, rich in oxygen and nitrogen terminations. This res…
▽ More
The ability to form diamond electrodes on insulating polycrystalline diamond substrates using single-step laser patterning, and the use of the electrodes as a substrate that supports the adhesion and proliferation of human mesenchymal stem cells (hMSCs) is demonstrated. Laser induced graphitisation results in a conductive amorphous carbon surface, rich in oxygen and nitrogen terminations. This results in an electrode with a high specific capacitance of 182 uF/cm2, a wide water window of 3.25 V, and a low electrochemical impedance of 129 Ohms/cm2 at 1 kHz. The electrodes surface exhibited a good level of biocompatibility with hMSCs, supporting cell adhesion and proliferation. The cells cultured on the electrode displayed significant elongation and alignment along the direction of the laser patterned microgrooves. Because of its favourable electrochemical performance and biocompatibility, the laser-patterned diamond electrodes create a potential for a versatile platform in stem cell therapeutics.
△ Less
Submitted 28 July, 2024;
originally announced July 2024.
-
Laser driven miniature diamond implant for wireless retinal prostheses
Authors:
Arman Ahnood,
Ross Cheriton,
Anne Bruneau,
James A. Belcourt,
Jean Pierre Ndabakuranye,
William Lemaire,
Rob Hilkes,
Réjean Fontaine,
John P. D. Cook,
Karin Hinzer,
Steven Prawer
Abstract:
The design and benchtop operation of a wireless miniature epiretinal stimulator implant is reported. The implant is optically powered and controlled using safe illumination at near-infrared wavelengths. An application-specific integrated circuit (ASIC) hosting a digital control unit is used to control the implant's electrodes. The ASIC is powered using an advanced photovoltaic (PV) cell and progra…
▽ More
The design and benchtop operation of a wireless miniature epiretinal stimulator implant is reported. The implant is optically powered and controlled using safe illumination at near-infrared wavelengths. An application-specific integrated circuit (ASIC) hosting a digital control unit is used to control the implant's electrodes. The ASIC is powered using an advanced photovoltaic (PV) cell and programmed using a single photodiode. Diamond packaging technology is utilized to achieve high-density integration of the implant optoelectronic circuitry, as well as individual connections between a stimulator chip and 256 electrodes, within a 4.6 mm x 3.7 mm x 0.9 mm implant package. An ultrahigh efficiency PV cell with a monochromatic power conversion efficiency of 55% is used to power the implant. On-board photodetection circuity with a bandwidth of 3.7 MHz is used for forward data telemetry of stimulation parameters. In comparison to implants which utilize inductively coupled coils, laser power delivery enables a high degree of miniaturization and lower surgical complexity. The device presented combines the benefits of implant miniaturization and a flexible stimulation strategy provided by a dedicated stimulator chip. This development provides a route to fully wireless miniaturized minimally invasive implants with sophisticated functionalities.
△ Less
Submitted 20 June, 2024;
originally announced July 2024.
-
Impact of surface treatments on the electron affinity of nitrogen-doped ultrananocrystalline diamond
Authors:
Andre Chambers,
Daniel J. McCloskey,
Nikolai Dontschuk,
Hassan N. Al Hashem,
Billy J. Murdoch,
Alastair Stacey,
Steven Prawer,
Arman Ahnood
Abstract:
In recent years, various forms of nanocrystalline diamond (NCD) have emerged as an attractive group of diamond/graphite mixed-phase materials for a range of applications from electron emission sources to electrodes for neural interfacing. To tailor their properties for different uses, NCD surfaces can be terminated with various chemical functionalities, in particular hydrogen and oxygen, which shi…
▽ More
In recent years, various forms of nanocrystalline diamond (NCD) have emerged as an attractive group of diamond/graphite mixed-phase materials for a range of applications from electron emission sources to electrodes for neural interfacing. To tailor their properties for different uses, NCD surfaces can be terminated with various chemical functionalities, in particular hydrogen and oxygen, which shift the band edge positions and electron affinity values. While the band edge positions of chemically terminated single crystal diamond are well understood, the same is not true for nanocrystalline diamond, which has uncontrolled crystallographic surfaces with a variety of chemical states as well as graphitic grain boundary regions. In this work, the relative band edge positions of as-grown, hydrogen terminated, and oxygen terminated nitrogen-doped ultrananocrystalline diamond (N-UNCD) are determined using ultraviolet photoelectron spectroscopy (UPS), while the band bending is investigated using photoelectrochemical measurements. In contrast to the widely reported negative electrode affinity of hydrogen terminated single crystal diamond, our work demonstrates that hydrogen terminated N-UNCD exhibits a positive electron affinity owing to the increased surface and bulk defect densities. These findings elucidate the marked differences in electrochemical properties of hydrogen and oxygen terminated N-UNCD, such as the dramatic changes in electrochemical capacitance.
△ Less
Submitted 20 June, 2024;
originally announced June 2024.
-
Miniature fluorescence sensor for quantitative detection of brain tumour
Authors:
Jean Pierre Ndabakuranye,
James Belcourt,
Deepak Sharma,
Cathal D. O'Connell,
Victor Mondal,
Sanjay K. Srivastava,
Alastair Stacey,
Sam Long,
Bobbi Fleiss,
Arman Ahnood
Abstract:
Fluorescence-guided surgery has emerged as a vital tool for tumour resection procedures. As well as intraoperative tumour visualisation, 5-ALA-induced PpIX provides an avenue for quantitative tumour identification based on ratiometric fluorescence measurement. To this end, fluorescence imaging and fibre-based probes have enabled more precise demarcation between the cancerous and healthy tissues. T…
▽ More
Fluorescence-guided surgery has emerged as a vital tool for tumour resection procedures. As well as intraoperative tumour visualisation, 5-ALA-induced PpIX provides an avenue for quantitative tumour identification based on ratiometric fluorescence measurement. To this end, fluorescence imaging and fibre-based probes have enabled more precise demarcation between the cancerous and healthy tissues. These sensing approaches, which rely on collecting the fluorescence light from the tumour resection site and its remote spectral sensing, introduce challenges associated with optical losses. In this work, we demonstrate the viability of tumour detection at the resection site using a miniature fluorescence measurement system. Unlike the current bulky systems, which necessitate remote measurement, we have adopted a millimetre-sized spectral sensor chip for quantitative fluorescence measurements. A reliable measurement at the resection site requires a stable optical window between the tissue and the optoelectronic system. This is achieved using an antifouling diamond window, which provides stable optical transparency. The system achieved a sensitivity of 92.3% and specificity of 98.3% in detecting a surrogate tumour at a resolution of 1 x 1 mm2. As well as addressing losses associated with collecting and coupling fluorescence light in the current remote sensing approaches, the small size of the system introduced in this work paves the way for its direct integration with the tumour resection tools with the aim of more accurate interoperative tumour identification.
△ Less
Submitted 20 June, 2024;
originally announced June 2024.
-
Towards optical neuromodulation using nitrogen-doped ultrananocrystalline diamond photoelectrodes
Authors:
Samira Falahatdoost,
Andre Chambers,
Alastair Stacey,
Steven Prawer,
Arman Ahnood
Abstract:
Nitrogen-doped ultrananocrystalline diamond (N-UNCD) is a form of diamond electrode with near-infrared photoresponsivity, making it well suited for physiological applications. N-UNCD's photoresponsivity is strongly influenced by its surface. While it is known that oxygen treatment provides a higher photoresponsivity, a better understanding of its surface processes is needed to tailor the material…
▽ More
Nitrogen-doped ultrananocrystalline diamond (N-UNCD) is a form of diamond electrode with near-infrared photoresponsivity, making it well suited for physiological applications. N-UNCD's photoresponsivity is strongly influenced by its surface. While it is known that oxygen treatment provides a higher photoresponsivity, a better understanding of its surface processes is needed to tailor the material for optical neuromodulation. This work examines the impact of various oxygen treatment methods, with aim of creating oxygen rich surfaces with different chemical and structural properties. Surface characterisation methods along with electrochemical and photoelectrochemical measurements and modelling were used to investigate the films. It was found that oxygen furnace annealing resulted in orders of magnitude improvement in the near-infrared photoresponsivity, to 3.75 +/- 0.05 uA/W. This translates to an approximate 200 times increase in the photocurrent compared to the untreated surface. This enhancement in photocurrent is largely due to the changes in the chemical species present at the surface. The photocurrent is estimated to be sufficient for extra-cellular stimulation of brain neurons within the safe optical exposure limit, positioning N-UNCD as an excellent candidate to be used in next-generation photoelectrodes for photobiomodulation.
△ Less
Submitted 20 June, 2024;
originally announced June 2024.
-
Vertical CNT-Si Photodiode Array
Authors:
Arman Ahnood,
Hang Zhou,
Qing Dai,
Yuri Vygranenko,
Yuji Suzuki,
MR Esmaeili-Rad,
Gehan Amaratunga,
Arokia Nathan
Abstract:
A photodiode consisting of nanopillars of thin-film silicon p-i-n on an array of vertically aligned carbon nanotubes (CNTs) with a noncontinuous cathode electrode is demonstrated. The structure exploits the intrinsic enhancement of the CNTs electric field, which leads to reduction in the photodiodes operating voltage and response time and enhancement of optical coupling due to better light trappin…
▽ More
A photodiode consisting of nanopillars of thin-film silicon p-i-n on an array of vertically aligned carbon nanotubes (CNTs) with a noncontinuous cathode electrode is demonstrated. The structure exploits the intrinsic enhancement of the CNTs electric field, which leads to reduction in the photodiodes operating voltage and response time and enhancement of optical coupling due to better light trapping, as compared with the conventional planar photodiode. These improvements translate to higher resolution and higher frame rate flat-panel imaging systems for a broad range of applications, including computed tomography and particle detection.
△ Less
Submitted 20 June, 2024;
originally announced June 2024.
-
A novel optical assay system for bilirubin concentration measurement in whole blood
Authors:
Jean Pierre Ndabakuranye,
Anushi E. Rajapaksa,
Genia Burchall,
Shiqiang Li,
Steven Prawer,
Arman Ahnood
Abstract:
As a biomarker for liver disease, bilirubin has been utilized in prognostic scoring systems for cirrhosis. While laboratory-based methods are used to determine bilirubin levels in clinical settings, they do not readily lend themselves to applications outside of hospitals. Consequently, bilirubin monitoring for cirrhotic patients is often performed only intermittently; thus, episodes requiring clin…
▽ More
As a biomarker for liver disease, bilirubin has been utilized in prognostic scoring systems for cirrhosis. While laboratory-based methods are used to determine bilirubin levels in clinical settings, they do not readily lend themselves to applications outside of hospitals. Consequently, bilirubin monitoring for cirrhotic patients is often performed only intermittently; thus, episodes requiring clinical interventions could be missed. This work investigates the feasibility of measuring bilirubin concentration in whole porcine blood samples using dual-wavelength transmission measurement. A compact and low-cost dual-wavelength transmission measurement setup is developed and optimized to measure whole blood bilirubin concentrations. Using small volumes of whole porcine blood (72 μL), we measured the bilirubin concentration within a range corresponding to healthy individuals and cirrhotic patients (1.2-30 mg/dL). We demonstrate that bilirubin levels can be estimated with a positive correlation (R-square > 0.95) and an accuracy of +/- 1.7 mg/dL, with higher reliability in cirrhotic bilirubin concentrations (> 4 mg/dL), critical for high-risk patients. The optical and electronic components utilized are economical and can be readily integrated into a miniature, low-cost, and user-friendly system. This could provide a pathway for point-of-care monitoring of blood bilirubin outside of medical facilities.
△ Less
Submitted 20 June, 2024;
originally announced June 2024.
-
A leadless power transfer and wireless telemetry solutions for an endovascular electrocorticography
Authors:
Zhangyu Xu,
Majid Khazaee,
Nhan Duy Truong,
Deniel Havenga,
Armin Nikpour,
Arman Ahnood,
Omid Kavehei
Abstract:
Endovascular brain-computer interfaces (eBCIs) offer a minimally invasive way to connect the brain to external devices, merging neuroscience, engineering, and medical technology. Achieving wireless data and power transmission is crucial for the clinical viability of these implantable devices. Typically, solutions for endovascular electrocorticography (ECoG) include a sensing stent with multiple el…
▽ More
Endovascular brain-computer interfaces (eBCIs) offer a minimally invasive way to connect the brain to external devices, merging neuroscience, engineering, and medical technology. Achieving wireless data and power transmission is crucial for the clinical viability of these implantable devices. Typically, solutions for endovascular electrocorticography (ECoG) include a sensing stent with multiple electrodes (e.g. in the superior sagittal sinus) in the brain, a subcutaneous chest implant for wireless energy harvesting and data telemetry, and a long (tens of centimetres) cable with a set of wires in between. This long cable presents risks and limitations, especially for younger patients or those with fragile vasculature. This work introduces a wireless and leadless telemetry and power transfer solution for endovascular ECoG. The proposed solution includes an optical telemetry module and a focused ultrasound (FUS) power transfer system. The proposed system can be miniaturised to fit in an endovascular stent. Our solution uses optical telemetry for high-speed data transmission (over 2 Mbit/s, capable of transmitting 41 ECoG channels at a 2 kHz sampling rate and 24-bit resolution) and the proposed power transferring scheme provides up to 10mW power budget into the site of the endovascular implants under the safety limit. Tests on bovine tissues confirmed the system's effectiveness, suggesting that future custom circuit designs could further enhance eBCI applications by removing wires and auxiliary implants, minimising complications.
△ Less
Submitted 8 May, 2024;
originally announced May 2024.
-
A Single Sensor Based Multispectral Imaging Camera using a Narrow Spectral Band Colour Mosaic Integrated on the Monochrome CMOS Image Sensor
Authors:
Xin He,
Yajing Liu,
Kumar Ganesan,
Arman Ahnood,
Paul Beckett,
Fatima Eftekhari,
Dan Smith,
MD Hemayet Uddin,
Efstratios Skafidas,
Ampalavanapillai Nirmalathas,
Ranjith Rajasekharan Unnithan
Abstract:
A multispectral image camera captures image data within specific wavelength ranges in narrow wavelength bands across the electromagnetic spectrum. Images from a multispectral camera can extract additional information that the human eye or a normal camera fails to capture and thus may have important applications in precision agriculture, forestry, medicine and object identification. Conventional mu…
▽ More
A multispectral image camera captures image data within specific wavelength ranges in narrow wavelength bands across the electromagnetic spectrum. Images from a multispectral camera can extract additional information that the human eye or a normal camera fails to capture and thus may have important applications in precision agriculture, forestry, medicine and object identification. Conventional multispectral cameras are made up of multiple image sensors each fitted with a narrow passband wavelength filter and optics, which makes them heavy, bulky, power hungry and very expensive. The multiple optics also create image co-registration problem. Here, we demonstrate a single sensor based three band multispectral camera using a narrow spectral band RGB colour mosaic in a Bayer pattern integrated on a monochrome CMOS sensor. The narrow band colour mosaic is made of a hybrid combination of plasmonic colour filters and heterostructured dielectric multilayer. The demonstrated camera technology has reduced cost, weight, size and power by almost n times (where n is the number of bands) compared to a conventional multispectral camera.
△ Less
Submitted 2 December, 2020;
originally announced December 2020.
-
Feasibility Assessment of an Optically Powered Digital Retinal Prosthesis Architecture for Retinal Ganglion Cell Stimulation
Authors:
William Lemaire,
Maher Benhouria,
Konin Koua,
Wei Tong,
Gabriel Martin-Hardy,
Melanie Stamp,
Kumaravelu Ganesan,
Louis-Philippe Gauthier,
Marwan Besrour,
Arman Ahnood,
David John Garrett,
Sébastien Roy,
Michael Ibbotson,
Steven Prawer,
Réjean Fontaine
Abstract:
Clinical trials previously demonstrated the notable capacity to elicit visual percepts in blind patients affected with retinal diseases by electrically stimulating the remaining neurons on the retina. However, these implants restored very limited visual acuity and required transcutaneous cables traversing the eyeball, leading to reduced reliability and complex surgery with high postoperative infec…
▽ More
Clinical trials previously demonstrated the notable capacity to elicit visual percepts in blind patients affected with retinal diseases by electrically stimulating the remaining neurons on the retina. However, these implants restored very limited visual acuity and required transcutaneous cables traversing the eyeball, leading to reduced reliability and complex surgery with high postoperative infection risks. To overcome the limitations imposed by cables, a retinal implant architecture in which near-infrared illumination carries both power and data through the pupil to a digital stimulation controller is presented. A high efficiency multi-junction photovoltaic cell transduces the optical power to a CMOS stimulator capable of delivering flexible interleaved sequential stimulation through a diamond microelectrode array. To demonstrate the capacity to elicit a neural response with this approach while complying with the optical irradiance limit at the pupil, fluorescence imaging with a calcium indicator is used on a degenerate rat retina. The power delivered by the laser at the permissible irradiance of 4 mW/mm2 at 850 nm is shown to be sufficient to both power the stimulator ASIC and elicit a response in retinal ganglion cells (RGCs), with the ability to generate of up to 35 000 pulses per second at the average stimulation threshold. This confirms the feasibility of generating a response in RGCs with an infrared-powered digital architecture capable of delivering complex sequential stimulation patterns at high repetition rates, albeit with some limitations.
△ Less
Submitted 13 October, 2023; v1 submitted 23 October, 2020;
originally announced October 2020.
-
Near-infrared excitation of nitrogen-doped ultrananocrystalline diamond photoelectrodes in saline solution
Authors:
Andre Chambers,
Arman Ahnood,
Samira Falahatdoost,
Steve Yianni,
David Hoxley,
Brett C. Johnson,
David J. Garrett,
Snjezana Tomljenovic-Hanic,
Steven Prawer
Abstract:
Nitrogen-doped ultrananocrystalline diamond (N-UNCD) is a promising material for a variety of neural interfacing applications, due to its unique combination of high conductivity, bioinertness, and durability. One emerging application for N-UNCD is as a photoelectrode material for high-precision optical neural stimulation. This may be used for the treatment of neurological disorders and for implant…
▽ More
Nitrogen-doped ultrananocrystalline diamond (N-UNCD) is a promising material for a variety of neural interfacing applications, due to its unique combination of high conductivity, bioinertness, and durability. One emerging application for N-UNCD is as a photoelectrode material for high-precision optical neural stimulation. This may be used for the treatment of neurological disorders and for implantable bionic devices such as cochlear ear implants and retinal prostheses. N-UNCD is a well-suited material for stimulation photoelectrodes, exhibiting a photocurrent response to light at visible wavelengths with a high charge injection density [A. Ahnood, A. N. Simonov, J. S. Laird, M. I. Maturana, K. Ganesan, A. Stacey, M. R. Ibbotson, L. Spiccia, and S. Prawer, Appl. Phys. Lett. 108, 104103 (2016)]. In this study, the photoresponse of N-UNCD to near-infrared (NIR) irradiation is measured. NIR light has greater optical penetration through tissue than visible wavelengths, opening the possibility to stimulate previously inaccessible target cells. It is found that N-UNCD exhibits a photoresponsivity which diminishes rapidly with increasing wavelength and is attributed to transitions between mid-gap states and the conduction band tail associated with the graphitic phase present at the grain boundaries. Oxygen surface termination on the diamond films provides further enhancement of the injected charge per photon, compared to as-grown or hydrogen terminated surfaces. Based on the measured injected charge density, we estimate that the generated photocurrent of oxygen terminated N-UNCD is sufficient to achieve extracellular stimulation of brain tissue within the safe optical exposure limit.
△ Less
Submitted 20 November, 2018;
originally announced November 2018.