-
Large-format imaging systems based on solid-state detectors in optical astronomy
Authors:
V V Vlasyuk,
I V Afanasieva,
V I Ardilanov,
V A Murzin,
N G Ivaschenko,
M A Pritychenko,
S N Dodonov
Abstract:
The development of technologies for creating various types of solid-state detectors for optical astronomy is reviewed. The principles of designing astronomical photodetecting systems with large-format sensors based on charge-coupled device (CCD) and complementary metal oxide semiconductor (CMOS) structures are analyzed. Examples of the most advanced projects to which they have been applied are giv…
▽ More
The development of technologies for creating various types of solid-state detectors for optical astronomy is reviewed. The principles of designing astronomical photodetecting systems with large-format sensors based on charge-coupled device (CCD) and complementary metal oxide semiconductor (CMOS) structures are analyzed. Examples of the most advanced projects to which they have been applied are given. The history of the creation of optical detectors for telescopes operated in Russia is described, and a brief description and characteristics of the developed systems are provided. The results of testing in real research are displayed. The prospects for creating large-format systems based on CCD and CMOS detectors manufactured in Russia and abroad are discussed.
△ Less
Submitted 14 December, 2024;
originally announced December 2024.
-
Large-format photodetecting system pCam6060 with a GSENSE6060BSI CMOS detector, developed at SAO RAS and optimized for photometric methods
Authors:
I. Afanasieva,
V. Murzin,
V. Ardilanov,
N. Ivaschenko,
M. Pritychenko
Abstract:
The pCam6060 photodetecting system was developed at SAO RAS and is based on the GSENSE6060BSI photodetector manufactured by GPixel (China) with a frame format of 6144x6144 active pixels and a pixel size of 10 mkm. The readout speed reached 11 fps. The back-illuminated detector has a wide spectral range of 200-1040 nm with a minimum quantum efficiency (QE) of 10% and maximum sensitivity of 95% at 5…
▽ More
The pCam6060 photodetecting system was developed at SAO RAS and is based on the GSENSE6060BSI photodetector manufactured by GPixel (China) with a frame format of 6144x6144 active pixels and a pixel size of 10 mkm. The readout speed reached 11 fps. The back-illuminated detector has a wide spectral range of 200-1040 nm with a minimum quantum efficiency (QE) of 10% and maximum sensitivity of 95% at 580 nm. The quantum efficiency in the near-infrared range was 58% at 850 nm. The pCam6060 system controller implements a mode of simultaneous image readout via two 12-bit video channels with different gain and their subsequent combination in the controller into a single frame with an extended 16-bit dynamic range. This method simultaneously achieves a low readout noise level (about 3 e-) in the high-gain channel and a large dynamic range (full well capacity of about 100000 e-) in the low-gain channel. Back-illuminated CMOS detectors, unlike front-illuminated devices, do not have the effect of long-term preserving the residual charge from previous exposures, which makes them suitable for recording faint objects in photometric long-exposure observation methods. Communication between the host computer and the camera was carried out via a fiber optic line at distances of up to 50 m. Video data are recorded on the computer hard drive in real-time. The pCam6060 photodetecting system is designed for astronomical applications and has a moisture-proof design.
△ Less
Submitted 13 December, 2024;
originally announced December 2024.
-
Small telescopes being effective: MAGIC or not?
Authors:
Victor L. Afanasiev,
Eugene A. Malygin,
Elena S. Shablovinskaya,
Roman I. Uklein,
Vladimir R. Amirkhanyan,
Alexander E. Perepelitsyn,
Irina V. Afanasieva
Abstract:
The paper describes the MAGIC multi-mode focal reducer (Monitoring of Active Galaxies by Investigation of their Cores), commissioned on the 1-m Zeiss-1000 telescope of the Special Astrophysical Observatory of the Russian Academy of Sciences in September 2020. Three observational modes are currently realised: photometry, polarimetry, and long-slit spectroscopy. Reducing the focal length makes it po…
▽ More
The paper describes the MAGIC multi-mode focal reducer (Monitoring of Active Galaxies by Investigation of their Cores), commissioned on the 1-m Zeiss-1000 telescope of the Special Astrophysical Observatory of the Russian Academy of Sciences in September 2020. Three observational modes are currently realised: photometry, polarimetry, and long-slit spectroscopy. Reducing the focal length makes it possible to obtain a sufficiently large field of view for photometry and a large slit height for spectroscopy of $\sim$12$'$, as well as a large field of view for polarimetry with a quadrupole Wollaston prism of $\sim$6$'$.4. This feature makes the complex study of extended nebulae and galaxies efficient. The MAGIC capabilities are presented in examples of observations of various astronomical objects. The spectral mode in the range of 4000-7200 AA provides the spectral resolution $R \sim$ 1000; for a starlike target up to 14 mag in medium-band filters with a seeing of 1$''$ for 20 minutes of total exposure, the photometry accuracy is better than 0.01 mag and the polarization accuracy is better than 0.6%. Especially for the new focal reducer, an offset guide and a position angle rotation system were implemented. The results of the modernization of the baffle system in the optical scheme of the telescope for the suppression of scattered light are also described.
△ Less
Submitted 23 September, 2023;
originally announced September 2023.
-
Astronomical Camera Based on a CCD261-84 Detector with Increased Sensitivity in the Near-Infrared
Authors:
Irina Afanasieva,
Valery Murzin,
Valery Ardilanov,
Nikolai Ivaschenko,
Maksim Pritychenko,
Alexei Moiseev,
Elena Shablovinskaya,
Eugene Malygin
Abstract:
Herein, we describe the design, implementation and operation principles of an astronomical camera system, based on a large-format CCD261-84 detector with an extremely thick 200 mkm substrate. The DINACON-V controller was used with the CCD to achieve high performance and low noise. The CCD system photometric characteristics are presented. A spatial autocorrelation analysis of flat-field images was…
▽ More
Herein, we describe the design, implementation and operation principles of an astronomical camera system, based on a large-format CCD261-84 detector with an extremely thick 200 mkm substrate. The DINACON-V controller was used with the CCD to achieve high performance and low noise. The CCD system photometric characteristics are presented. A spatial autocorrelation analysis of flat-field images was performed to reveal the dependence of substrate voltage on the lateral charge spreading. The investigation of the dispersion index for the optimal choice of exposure time is discussed. Studies of the patterns of fringes were carried out in comparison with previous detectors. The amplitude of fringes with CCD261-84 was significantly lower, compared to previous-generation detectors. The results of using a new camera for imaging and spectral observations at the Russian 6 m telescope with the SCORPIO-2 multimode focal reducer are considered. The developed CCD camera system makes it possible to significantly increase the sensitivity in the 800-1000 spectral range.
△ Less
Submitted 5 July, 2023;
originally announced July 2023.
-
Universal focal reducer for small telescopes
Authors:
V. L. Afanasiev,
V. R. Amirkhanyan,
R. I. Uklein,
A. E. Perepelitsyn,
E. A. Malygin,
E. S. Shablovinskaya,
I. V. Afanasieva
Abstract:
This paper is devoted to the memory of Dr. Victor Afanasiev and his immense legacy. The report highlights the capabilities of two new instruments tested at the 1-meter Zeiss-1000 telescope of SAO RAS: the Stokes Polarimeter (StoP) and the MAGIC focal reducer. Optimized for the study of active galactic nuclei (AGN), methodically, these instruments are suitable for a wide range of small telescope ta…
▽ More
This paper is devoted to the memory of Dr. Victor Afanasiev and his immense legacy. The report highlights the capabilities of two new instruments tested at the 1-meter Zeiss-1000 telescope of SAO RAS: the Stokes Polarimeter (StoP) and the MAGIC focal reducer. Optimized for the study of active galactic nuclei (AGN), methodically, these instruments are suitable for a wide range of small telescope tasks. The fields of view of StoP and MAGIC are 6' and 13' for direct images, respectively. The StoP device allows one to conduct photometric observations and polarimetric ones with a double Wollaston prism; the spectral mode was added to MAGIC. For a starlike target up to 14 mag in medium-band filters with a seeing of 1" for 20 minutes of total exposure, the photometry accuracy is better than 0.01 mag and the polarization accuracy is better than 0.6%. The available spectral range obtained with the volume phase holographic grating in MAGIC is 4000-7200AA with a dispersion of 2A/px. StoP and MAGIC received the first light in 2020 and are used in test mode at the Zeiss-1000. The report discusses the first results obtained by the authors with new instruments, as well as further prospects
△ Less
Submitted 5 December, 2021;
originally announced December 2021.
-
Development of Large-Format Camera Systems Based on the Latest Generation Sensors for the 6-m Telescope
Authors:
V. I. Ardilanov,
V. A. Murzin,
I. V. Afanasieva,
N. G. Ivaschenko,
M. A. Pritychenko
Abstract:
The design and implementation of astronomical cameras based on the large-format CCD and CMOS detectors is described in this paper. The Dinacon-5 controller is used for work with the CCDs and to achieve high performance and low noise. A new controller is designed for CMOS sensors. The main characteristics of the provided systems are estimated on the basis of experimental data. The spatial autocorre…
▽ More
The design and implementation of astronomical cameras based on the large-format CCD and CMOS detectors is described in this paper. The Dinacon-5 controller is used for work with the CCDs and to achieve high performance and low noise. A new controller is designed for CMOS sensors. The main characteristics of the provided systems are estimated on the basis of experimental data. The spatial autocorrelation analysis is applied for PSF estimation. The obtained test results are presented.
△ Less
Submitted 20 January, 2021;
originally announced January 2021.
-
Study of Distortions in Statistics of Counts in CCD Observations using the Fano Factor
Authors:
I. V. Afanasieva
Abstract:
Factors distorting the statistics of photocounts when acquiring objects with low fluxes were considered here. Measurements of the Fano factor for existing CCD systems were conducted. The study allows one to conclude on the quality of the CCD video signal processing channel. The optimal strategy for faint object observations was suggested.
Factors distorting the statistics of photocounts when acquiring objects with low fluxes were considered here. Measurements of the Fano factor for existing CCD systems were conducted. The study allows one to conclude on the quality of the CCD video signal processing channel. The optimal strategy for faint object observations was suggested.
△ Less
Submitted 22 August, 2016;
originally announced August 2016.
-
Data Acquisition and Control System for High-Performance Large-Area CCD Systems
Authors:
I. V. Afanasieva
Abstract:
Astronomical CCD systems based on second-generation DINACON controllers were developed at the SAO RAS Advanced Design Laboratory more than seven years ago and since then have been in constant operation at the 6-meter and Zeiss-1000 telescopes. Such systems use monolithic large-area CCDs. We describe the software developed for the control of a family of large-area CCD systems equipped with a DINACO…
▽ More
Astronomical CCD systems based on second-generation DINACON controllers were developed at the SAO RAS Advanced Design Laboratory more than seven years ago and since then have been in constant operation at the 6-meter and Zeiss-1000 telescopes. Such systems use monolithic large-area CCDs. We describe the software developed for the control of a family of large-area CCD systems equipped with a DINACON-II controller. The software suite serves for acquisition, primary reduction, visualization, and storage of video data, and also for the control, setup, and diagnostics of the CCD system.
△ Less
Submitted 20 July, 2015;
originally announced July 2015.