-
nuSCOPE: A short-baseline neutrino beam at CERN for high-precision cross-section measurements
Authors:
F. Acerbi,
C. Andreopoulos,
I. Angelis,
A. Baratto Roldan,
L. Bomben,
M. Bonesini,
F. Bramati,
A. Branca,
C. Brizzolari,
G. Brunetti,
M. Buizza Avanzini,
S. Capelli,
M. Capitani,
S. Carturan,
M. G. Catanesi,
S. Cecchini,
N. Charitonidis,
F. Cindolo,
J. Cogan,
G. Cogo,
G. Collazuol,
D. D'Ago,
F. Dal Corso,
G. De Rosa,
S. Dolan
, et al. (59 additional authors not shown)
Abstract:
A new generation of neutrino cross-section experiments at the GeV scale is crucial in the precision era of oscillation physics and lepton flavor studies. In this document, we present a novel neutrino beam design that leverages the experience and R&D achievements of the NP06/ENUBET and NuTag Collaborations and explore its potential implementation at CERN. This beam enables flux monitoring at the pe…
▽ More
A new generation of neutrino cross-section experiments at the GeV scale is crucial in the precision era of oscillation physics and lepton flavor studies. In this document, we present a novel neutrino beam design that leverages the experience and R&D achievements of the NP06/ENUBET and NuTag Collaborations and explore its potential implementation at CERN. This beam enables flux monitoring at the percent level and provides a neutrino energy measurement independent of final state particle reconstruction at the neutrino detector. As a result, it eliminates the two primary sources of systematic uncertainty in cross-section measurements: flux normalization and energy bias caused by nuclear effects. We provide a detailed description of the beam technology and instrumentation, along with an overview of its physics potential, with particular emphasis on cross-sections relevant to DUNE and Hyper-Kamiokande.
△ Less
Submitted 19 June, 2025; v1 submitted 27 March, 2025;
originally announced March 2025.
-
Flow and thermal modelling of the argon volume in the DarkSide-20k TPC
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick,
M. Bloem
, et al. (279 additional authors not shown)
Abstract:
The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ~50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we…
▽ More
The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ~50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we have performed computational fluid dynamics simulations and heat transfer calculations. The residence time distribution shows that the detector is well-mixed on time-scales of the turnover time (~40 d). Notably, simulations show that despite a two-order-of-magnitude difference between the turnover time and the half-life of $^{83\text{m}}$Kr of 1.83 h, source atoms have the highest probability to reach the centre of the TPC 13 min after their injection, allowing for a homogeneous distribution before undergoing radioactive decay. We further analyse the thermal aspects of dual-phase operation and define the requirements for the formation of a stable gas pocket on top of the liquid. We find a best-estimate value for the heat transfer rate at the liquid-gas interface of 62 W with an upper limit of 144 W and a minimum gas pocket inlet temperature of 89 K to avoid condensation on the acrylic anode. This study also informs the placement of liquid inlets and outlets in the TPC. The presented techniques are widely applicable to other large-scale, noble-liquid detectors.
△ Less
Submitted 26 June, 2025; v1 submitted 11 March, 2025;
originally announced March 2025.
-
Quantitative Determination of Spatial Resolution and Linearity of Position-Sensitive LG-SiPMs at Sub-Millimeter Scale via Ricean Distribution Fitting
Authors:
Aramis Raiola,
Fabio Acerbi,
Cyril Alispach,
Hossein Arabi,
Domenico della Volpe,
Alberto Gola,
Habib Zaidi
Abstract:
Position-sensitive SiPMs are useful in all light detection applications requiring a small number of readout channels while preserving the information about the incoming light's interaction position. Focusing on a 2x2 array of LG-SiPMs covering an area of $\sim 15.5 \times 15.5~\rm{mm}$ with just 6 readout channels, we proposed a quantitative method to evaluate image reconstruction performance. The…
▽ More
Position-sensitive SiPMs are useful in all light detection applications requiring a small number of readout channels while preserving the information about the incoming light's interaction position. Focusing on a 2x2 array of LG-SiPMs covering an area of $\sim 15.5 \times 15.5~\rm{mm}$ with just 6 readout channels, we proposed a quantitative method to evaluate image reconstruction performance. The method is based on a statistical approach to assess the device's precision (spatial resolution) and accuracy (linearity) in reconstructing the light spot center of gravity. This evaluation is achieved through a Rice probability distribution function fitting. We obtained an average sensor spatial resolution's best value of $81 \pm 3~\rm{μm}$ (standard deviation), which is achieved by reconstructing each position with the amplitude of the channels' output signals. The corresponding accuracy is $231 \pm 4~\rm{μm}$.
△ Less
Submitted 7 March, 2025;
originally announced March 2025.
-
The ENUBET monitored neutrino beam and its implementation at CERN
Authors:
ENUBET collaboration,
L. Halić,
F. Acerbi,
I. Angelis,
L. Bomben,
M. Bonesini,
F. Bramati,
A. Branca,
C. Brizzolari,
G. Brunetti,
M. Calviani,
S. Capelli,
M. Capitani,
S. Carturan,
M. G. Catanesi,
S. Cecchini,
N. Charitonidis,
F. Cindolo,
G. Cogo,
G. Collazuol,
F. Dal Corso,
C. Delogu,
G. De Rosa,
A. Falcone,
B. Goddard
, et al. (52 additional authors not shown)
Abstract:
The ENUBET project recently concluded the R&D for a site independent design of a monitored neutrino beam for high precision cross section measurements, in which the neutrino flux is inferred from the measurement of charged leptons in an instrumented decay tunnel. In this phase three fundamental results were obtained and will be discussed here: 1) a beamline not requiring a horn and relying on stat…
▽ More
The ENUBET project recently concluded the R&D for a site independent design of a monitored neutrino beam for high precision cross section measurements, in which the neutrino flux is inferred from the measurement of charged leptons in an instrumented decay tunnel. In this phase three fundamental results were obtained and will be discussed here: 1) a beamline not requiring a horn and relying on static focusing elements allows to perform a $ν_e$ cross section measurement in the DUNE energy range with 1% statistical uncertainty employing $10^{20}$ 400 GeV protons on target (pot) and a neutrino detector of the size of ProtoDUNE; 2) the instrumentation of the decay tunnel, based on a cost effective sampling calorimeter solution, has been tested with a large scale prototype achieving the performance required to identify positrons and muons from kaon decays with high signal-to-noise ratio; 3) the systematics budget on the neutrino flux is constrained at the 1% level by fitting the charged leptons observables measured in the decay tunnel. Based on these successful results ENUBET is now pursuing a study for a site dependent implementation at CERN in the framework of Physics Beyond Colliders. In this context a new beamline, able to enrich the neutrino flux at the energy of HK and to reduce by more than a factor 3 the needed pot, has been designed and is being optimized. The civil engineering and radioprotection studies for the siting of ENUBET in the North Area towards the two ProtoDUNEs are also in the scope of this work, with the goal of proposing a neutrino cross section experiment in 2026. The combined use of both the neutrino detectors and of the improved beamline would allow to perform cross section measurements with unprecedented precision in about 5 years with a proton request compatible with the needs of other users after CERN Long Shutdown 3.
△ Less
Submitted 8 January, 2025;
originally announced January 2025.
-
Quality Assurance and Quality Control of the $26~\text{m}^2$ SiPM production for the DarkSide-20k dark matter experiment
Authors:
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli. E. Aprile,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick,
M. Bloem,
S. Blua,
V. Bocci,
W. Bonivento
, et al. (267 additional authors not shown)
Abstract:
DarkSide-20k is a novel liquid argon dark matter detector currently under construction at the Laboratori Nazionali del Gran Sasso (LNGS) of the Istituto Nazionale di Fisica Nucleare (INFN) that will push the sensitivity for Weakly Interacting Massive Particle (WIMP) detection into the neutrino fog. The core of the apparatus is a dual-phase Time Projection Chamber (TPC), filled with \SI{50} {tonnes…
▽ More
DarkSide-20k is a novel liquid argon dark matter detector currently under construction at the Laboratori Nazionali del Gran Sasso (LNGS) of the Istituto Nazionale di Fisica Nucleare (INFN) that will push the sensitivity for Weakly Interacting Massive Particle (WIMP) detection into the neutrino fog. The core of the apparatus is a dual-phase Time Projection Chamber (TPC), filled with \SI{50} {tonnes} of low radioactivity underground argon (UAr) acting as the WIMP target. NUV-HD-cryo Silicon Photomultipliers (SiPM)s designed by Fondazione Bruno Kessler (FBK) (Trento, Italy) were selected as the photon sensors covering two $10.5~\text{m}^2$ Optical Planes, one at each end of the TPC, and a total of $5~\text{m}^2$ photosensitive surface for the liquid argon veto detectors. This paper describes the Quality Assurance and Quality Control (QA/QC) plan and procedures accompanying the production of FBK~NUV-HD-cryo SiPM wafers manufactured by LFoundry s.r.l. (Avezzano, AQ, Italy). SiPM characteristics are measured at 77~K at the wafer level with a custom-designed probe station. As of March~2025, 1314 of the 1400 production wafers (94% of the total) for DarkSide-20k were tested. The wafer yield is $93.2\pm2.5$\%, which exceeds the 80\% specification defined in the original DarkSide-20k production plan.
△ Less
Submitted 19 March, 2025; v1 submitted 25 December, 2024;
originally announced December 2024.
-
Patient-specific prediction of glioblastoma growth via reduced order modeling and neural networks
Authors:
D. Cerrone,
D. Riccobelli,
S. Gazzoni,
P. Vitullo,
F. Ballarin,
J. Falco,
F. Acerbi,
A. Manzoni,
P. Zunino,
P. Ciarletta
Abstract:
Glioblastoma is among the most aggressive brain tumors in adults, characterized by patient-specific invasion patterns driven by the underlying brain microstructure. In this work, we present a proof-of-concept for a mathematical model of GBL growth, enabling real-time prediction and patient-specific parameter identification from longitudinal neuroimaging data.
The framework exploits a diffuse-int…
▽ More
Glioblastoma is among the most aggressive brain tumors in adults, characterized by patient-specific invasion patterns driven by the underlying brain microstructure. In this work, we present a proof-of-concept for a mathematical model of GBL growth, enabling real-time prediction and patient-specific parameter identification from longitudinal neuroimaging data.
The framework exploits a diffuse-interface mathematical model to describe the tumor evolution and a reduced-order modeling strategy, relying on proper orthogonal decomposition, trained on synthetic data derived from patient-specific brain anatomies reconstructed from magnetic resonance imaging and diffusion tensor imaging. A neural network surrogate learns the inverse mapping from tumor evolution to model parameters, achieving significant computational speed-up while preserving high accuracy.
To ensure robustness and interpretability, we perform both global and local sensitivity analyses, identifying the key biophysical parameters governing tumor dynamics and assessing the stability of the inverse problem solution. These results establish a methodological foundation for future clinical deployment of patient-specific digital twins in neuro-oncology.
△ Less
Submitted 1 April, 2025; v1 submitted 4 December, 2024;
originally announced December 2024.
-
Benchmarking the design of the cryogenics system for the underground argon in DarkSide-20k
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
R. Ardito,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick
, et al. (294 additional authors not shown)
Abstract:
DarkSide-20k (DS-20k) is a dark matter detection experiment under construction at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It utilises ~100 t of low radioactivity argon from an underground source (UAr) in its inner detector, with half serving as target in a dual-phase time projection chamber (TPC). The UAr cryogenics system must maintain stable thermodynamic conditions throughout t…
▽ More
DarkSide-20k (DS-20k) is a dark matter detection experiment under construction at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It utilises ~100 t of low radioactivity argon from an underground source (UAr) in its inner detector, with half serving as target in a dual-phase time projection chamber (TPC). The UAr cryogenics system must maintain stable thermodynamic conditions throughout the experiment's lifetime of over 10 years. Continuous removal of impurities and radon from the UAr is essential for maximising signal yield and mitigating background. We are developing an efficient and powerful cryogenics system with a gas purification loop with a target circulation rate of 1000 slpm. Central to its design is a condenser operated with liquid nitrogen which is paired with a gas heat exchanger cascade, delivering a combined cooling power of more than 8 kW. Here we present the design choices in view of the DS-20k requirements, in particular the condenser's working principle and the cooling control, and we show test results obtained with a dedicated benchmarking platform at CERN and LNGS. We find that the thermal efficiency of the recirculation loop, defined in terms of nitrogen consumption per argon flow rate, is 95 % and the pressure in the test cryostat can be maintained within $\pm$(0.1-0.2) mbar. We further detail a 5-day cool-down procedure of the test cryostat, maintaining a cooling rate typically within -2 K/h, as required for the DS-20k inner detector. Additionally, we assess the circuit's flow resistance, and the heat transfer capabilities of two heat exchanger geometries for argon phase change, used to provide gas for recirculation. We conclude by discussing how our findings influence the finalisation of the system design, including necessary modifications to meet requirements and ongoing testing activities.
△ Less
Submitted 19 February, 2025; v1 submitted 26 August, 2024;
originally announced August 2024.
-
DarkSide-20k sensitivity to light dark matter particles
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
R. Ardito,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick
, et al. (289 additional authors not shown)
Abstract:
The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV/c$^2$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more arg…
▽ More
The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV/c$^2$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more argon and is expected to start operation in 2027. Based on the DarkSide-50 experience, here we assess the DarkSide-20k sensitivity to models predicting light dark matter particles, including Weakly Interacting Massive Particles (WIMPs) and sub-GeV/c$^2$ particles interacting with electrons in argon atoms. With one year of data, a sensitivity improvement to dark matter interaction cross-sections by at least one order of magnitude with respect to DarkSide-50 is expected for all these models. A sensitivity to WIMP--nucleon interaction cross-sections below $1\times10^{-42}$ cm$^2$ is achievable for WIMP masses above 800 MeV/c$^2$. With 10 years exposure, the neutrino fog can be reached for WIMP masses around 5 GeV/c$^2$.
△ Less
Submitted 6 January, 2025; v1 submitted 8 July, 2024;
originally announced July 2024.
-
Radiation damage on Silicon Photomultipliers from ionizing and non-ionizing radiation of low-earth orbit operations
Authors:
Stefano Merzi,
Fabio Acerbi,
C. Aicardi,
D. Fiore,
V. Goiffon,
Alberto Gola,
O. Marcelot,
A. Materne,
O. Saint-Pe
Abstract:
Silicon Photomultipliers (SiPMs) are single photon detectors that gained increasing interest in many applications as an alternative to photomultiplier tubes. In particular in the field of space experiments, where volume, weight and power consumption are a major constraint, their advantages like compactness, ruggedness, and their potential to achieve high quantum efficiency from UV to NIR, makes th…
▽ More
Silicon Photomultipliers (SiPMs) are single photon detectors that gained increasing interest in many applications as an alternative to photomultiplier tubes. In particular in the field of space experiments, where volume, weight and power consumption are a major constraint, their advantages like compactness, ruggedness, and their potential to achieve high quantum efficiency from UV to NIR, makes them ideal candidates for spaceborne, low photon flux detectors. During space missions however, SiPMs are usually exposed to high levels of radiation, both ionizing and non-ionizing, which can deteriorate the performance of these detectors over time. The goal of this work is to compare process and layout variation of SiPMs in terms of their radiation damage effects to identify the features that helps reducing the deterioration of the performance and develop the next generation of more radiation tolerant detectors. To do this we irradiated with protons and X-rays several NUV-HD SiPMs with small area (single microcell, 0.2x0.2 mm2 and 1x1 mm2) produced in FBK. We performed online current-voltage measurements right after each irradiation step and a complete functional characterization before and after irradiation. We compare the results and show the most promising variations for future production of SiPMs for space applications.
△ Less
Submitted 12 May, 2024;
originally announced May 2024.
-
A new hybrid gadolinium nanoparticles-loaded polymeric material for neutron detection in rare event searches
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
R. Ardito,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick
, et al. (290 additional authors not shown)
Abstract:
Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surround…
▽ More
Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surrounding the active target volume. In the context of the development of DarkSide-20k detector at INFN Gran Sasso National Laboratory (LNGS), several R&D projects were conceived and developed for the creation of a new hybrid material rich in both hydrogen and gadolinium nuclei to be employed as an essential element of the neutron detector. Thanks to its very high cross-section for neutron capture, gadolinium is one of the most widely used elements in neutron detectors, while the hydrogen-rich material is instrumental in efficiently moderating the neutrons. In this paper results from one of the R&Ds are presented. In this effort the new hybrid material was obtained as a poly(methyl methacrylate) (PMMA) matrix, loaded with gadolinium oxide in the form of nanoparticles. We describe its realization, including all phases of design, purification, construction, characterization, and determination of mechanical properties of the new material.
△ Less
Submitted 29 April, 2024;
originally announced April 2024.
-
Characterization of FBK NUV-HD-Cryo SiPMs near LHe temperature
Authors:
Fengbo Gu,
Junhui Liao,
Jiangfeng Zhou,
Meiyuenan Ma,
Yuanning Gao,
Zhaohua Peng,
Jian Zheng,
Guangpeng An,
Lifeng Zhang,
Lei Zhang,
Zhuo Liang,
Xiuliang Zhao,
Fabio Acerbi,
Andrea Ficorella,
Alberto Gola,
Laura Parellada Monreal
Abstract:
Five FBK ``NUV-HD-Cryo'' SiPMs have been characterized at 7 K and 10 K, with 405 nm and 530 nm LED light, respectively. The dark current rate (DCR) was measured to be $\sim$ 1 Hz for the $\sim$ 100 mm$^2$-size SiPMs, or 0.01 Hz/mm$^2$, which is $\sim$ 7 orders lower than the DCR at room temperature (RT). Given the tiny DCR at these cryogenic temperatures, we measured the SiPMs' I-V curves with suc…
▽ More
Five FBK ``NUV-HD-Cryo'' SiPMs have been characterized at 7 K and 10 K, with 405 nm and 530 nm LED light, respectively. The dark current rate (DCR) was measured to be $\sim$ 1 Hz for the $\sim$ 100 mm$^2$-size SiPMs, or 0.01 Hz/mm$^2$, which is $\sim$ 7 orders lower than the DCR at room temperature (RT). Given the tiny DCR at these cryogenic temperatures, we measured the SiPMs' I-V curves with such a method: illuminated the SiPMs with weak light, which differs from the conventional measurements at RT. Then, we measured the photo-detection efficiency (PDE), after-pulse (AP), and cross-talk (CT) with a bias voltage ranging from 6 to 11 V overvoltage (OV). At the OV interval (6 to 11 V), the PDE was between 20\% - 45\%, and the AP and CT were both between $\sim$ 5\% and $\sim$ 20\%. Suppose the bias is $\ge$ 10 V OV, the PDE would be $\ge$ 40\%, and the AP and CT are $\sim$ 20\%. Combining all of the measurements, we are confident that the SiPMs can be equipped as the photosensors on liquid helium detectors, including but not limited to the time projection chambers, which we have proposed in hunting for low-mass dark matter directly and beyond.
△ Less
Submitted 16 March, 2025; v1 submitted 17 November, 2023;
originally announced November 2023.
-
Design and performance of the ENUBET monitored neutrino beam
Authors:
F. Acerbi,
I. Angelis,
L. Bomben,
M. Bonesini,
F. Bramati,
A. Branca,
C. Brizzolari,
G. Brunetti,
M. Calviani,
S. Capelli,
S. Carturan,
M. G. Catanesi,
S. Cecchini,
N. Charitonidis,
F. Cindolo,
G. Cogo,
G. Collazuol,
F. Dal Corso,
C. Delogu,
G. De Rosa,
A. Falcone,
B. Goddard,
A. Gola,
D. Guffanti,
L. Halić
, et al. (47 additional authors not shown)
Abstract:
The ENUBET project is aimed at designing and experimentally demonstrating the concept of monitored neutrino beams. These novel beams are enhanced by an instrumented decay tunnel, whose detectors reconstruct large-angle charged leptons produced in the tunnel and give a direct estimate of the neutrino flux at the source. These facilities are thus the ideal tool for high-precision neutrino cross-sect…
▽ More
The ENUBET project is aimed at designing and experimentally demonstrating the concept of monitored neutrino beams. These novel beams are enhanced by an instrumented decay tunnel, whose detectors reconstruct large-angle charged leptons produced in the tunnel and give a direct estimate of the neutrino flux at the source. These facilities are thus the ideal tool for high-precision neutrino cross-section measurements at the GeV scale because they offer superior control of beam systematics with respect to existing facilities. In this paper, we present the first end-to-end design of a monitored neutrino beam capable of monitoring lepton production at the single particle level. This goal is achieved by a new focusing system without magnetic horns, a 20 m normal-conducting transfer line for charge and momentum selection, and a 40 m tunnel instrumented with cost-effective particle detectors. Employing such a design, we show that percent precision in cross-section measurements can be achieved at the CERN SPS complex with existing neutrino detectors.
△ Less
Submitted 18 August, 2023;
originally announced August 2023.
-
Radiation damage on SiPMs for Space Applications
Authors:
Anna Rita Altamura,
Fabio Acerbi,
Benedetto Di Ruzza,
Enrico Verroi,
Stefano Merzi,
Alberto Gola
Abstract:
Silicon Photo-multipliers (SiPMs) are very sensitive photo-detectors that experienced a big development in the last years in several applications, like LIDAR, astrophysics, medical imaging and high energy physics (HEP) experiments. In HEP experiments, in particular, they are often exposed to significant radiation doses. The main purpose of this manuscript is the characterization of several FBK SiP…
▽ More
Silicon Photo-multipliers (SiPMs) are very sensitive photo-detectors that experienced a big development in the last years in several applications, like LIDAR, astrophysics, medical imaging and high energy physics (HEP) experiments. In HEP experiments, in particular, they are often exposed to significant radiation doses. The main purpose of this manuscript is the characterization of several FBK SiPM technologies when exposed to 74 $MeV$ protons with a total fluence comparable to the one that they would experience in space along circular Low Earth Orbits (LEO), Polar, during a five years mission.
In this work, we estimated the expected proton fluences along the selected orbit, by means of the SPENVIS software. Several fluence steps were chosen to consider dense fluence intervals and have a more accurate sight on the whole damage process. We estimated a maximum fluence achieved during the tests of $6.4 \times 10^{11}$ $n_{eq}/cm^2$. Based on such simulations, we irradiated several SiPM technologies. We developed a custom experimental setup, which was used to perform online reverse voltage-current, right after each irradiation step, to minimize the effect of the annealing on the measurement.
The results are then displayed, in particular the currents, the noise and the Photon Detection Efficiency. Also a 30-days study on the annealing of the devices was performed.
Lastly, the conclusions are drawn on the basis of the Signal-to-Noise Ratio (SNR), taking into account the standard parameters of famous satellites using similar orbits as the ones considered into this work.
△ Less
Submitted 15 December, 2021;
originally announced December 2021.
-
Characterization of Silicon Photomultipliers after proton irradiation up to $10^{12} n_{eq}/mm^2$
Authors:
A. R. Altamura,
F. Acerbi,
C. Nociforo,
V. Regazzoni,
A. Mazzi,
A. Gola
Abstract:
Silicon photomultipliers (SiPMs) are highly-sensitive photodetectors emerging as the technology of choice for many applications, including large high-energy physics experiments where they often are exposed to high radiation fluences. In recent years, there has been an increasing interest in assessing the performance deterioration of such detectors after the irradiation with proton or neutron, with…
▽ More
Silicon photomultipliers (SiPMs) are highly-sensitive photodetectors emerging as the technology of choice for many applications, including large high-energy physics experiments where they often are exposed to high radiation fluences. In recent years, there has been an increasing interest in assessing the performance deterioration of such detectors after the irradiation with proton or neutron, with different fluence levels.
In this work, samples of different FBK SiPM technologies, made with different manufacturing technologies, were irradiated at the INFN-LNS facility (Italy) with protons reaching fluences up to $10^{12}n_{eq}/mm^2$ (1 MeV neutron equivalent) which correspond $10^{14}n_{eq}/cm^2$ to and their performances were characterized in detail after an approximately 30 days room temperature annealing. The results show a significant worsening of the primary noise (dark count rate) of the detectors, which increases with the irradiation dose, whereas the other performance parameters like the micro-cell gain, the correlated noise probability and the photon detection efficiency do not show significant variations over the investigated dose range. The breakdown voltage estimation after irradiation is another important aspect for a SiPM. In this contribution, we show several methods for its estimation and compare the results. We also introduced new methodologies to characterize the performance of the SiPMs when they present a very high level of noise.
Lastly, we also analyzed the spatial localization of the proton-induced defects inside the device, i.e. the defects that mostly contribute to the increase of the DCR of the device, through the emission microscopy (EMMI) technique. In particular, we analyzed the SiPMs at the single cell level, trying to identify and spatially localize the defects.
△ Less
Submitted 23 June, 2021;
originally announced June 2021.
-
The ENUBET positron tagger prototype: construction and testbeam performance
Authors:
F. Acerbi,
M. Bonesini,
F. Bramati,
A. Branca,
C. Brizzolari,
G. Brunetti,
S. Capelli,
S. Carturan,
M. G. Catanesi,
S. Cecchini,
F. Cindolo,
G. Collazuol,
E. Conti,
F. Dal Corso,
C. Delogu,
G. De Rosa,
A. Falcone,
A. Gola,
C. Jollet,
B. Klicek,
Y. Kudenko,
M. Laveder,
A. Longhin,
L. Ludovici,
E. Lutsenko
, et al. (28 additional authors not shown)
Abstract:
A prototype for the instrumented decay tunnel of ENUBET was tested in 2018 at the CERN East Area facility with charged particles up to 5 GeV. This detector is a longitudinal sampling calorimeter with lateral scintillation light readout. The calorimeter was equipped by an additional "$t_0$-layer" for timing and photon discrimination. The performance of this detector in terms of electron energy reso…
▽ More
A prototype for the instrumented decay tunnel of ENUBET was tested in 2018 at the CERN East Area facility with charged particles up to 5 GeV. This detector is a longitudinal sampling calorimeter with lateral scintillation light readout. The calorimeter was equipped by an additional "$t_0$-layer" for timing and photon discrimination. The performance of this detector in terms of electron energy resolution, linearity, response to muons and hadron showers are presented in this paper and compared with simulation. The $t_0$-layer was studied both in standalone mode using pion charge exchange and in combined mode with the calorimeter to assess the light yield and the 1 mip/2 mip separation capability. We demonstrate that this system fulfills the requirements for neutrino physics applications and discuss performance and additional improvements.
△ Less
Submitted 12 June, 2020;
originally announced June 2020.
-
The hadronic beamline of the ENUBET neutrino beam
Authors:
ENUBET collaboration,
C. Delogu,
F. Acerbi,
A. Berra,
M. Bonesini,
A. Branca,
C. Brizzolari,
G. Brunetti,
M. Calviani,
S. Capelli,
S. Carturan,
M. G. Catanesi,
S. Cecchini,
N. Charitonidis,
F. Cindolo,
G. Collazuol,
E. Conti,
F. Dal Corso,
G. De Rosa,
A. Falcone,
A. Gola,
C. Jollet,
V. Kain,
B. Klicek,
Y. Kudenko
, et al. (35 additional authors not shown)
Abstract:
The ENUBET ERC project (2016-2021) is studying a facility based on a narrow band beam capable of constraining the neutrino fluxes normalization through the monitoring of the associated charged leptons in an instrumented decay tunnel. A key element of the project is the design and optimization of the hadronic beamline. In this proceeding we present progress on the studies of the proton extraction s…
▽ More
The ENUBET ERC project (2016-2021) is studying a facility based on a narrow band beam capable of constraining the neutrino fluxes normalization through the monitoring of the associated charged leptons in an instrumented decay tunnel. A key element of the project is the design and optimization of the hadronic beamline. In this proceeding we present progress on the studies of the proton extraction schemes. We also show a realistic implementation and simulation of the beamline.
△ Less
Submitted 26 November, 2020; v1 submitted 7 April, 2020;
originally announced April 2020.
-
Decay tunnel instrumentation for the ENUBET neutrino beam
Authors:
F. Acerbi,
A. Berra,
M. Bonesini,
A. Branca,
C. Brizzolari,
G. Brunetti,
M. Calviani,
S. Capelli,
S. Carturan,
M. G. Catanesi,
S. Cecchini,
N. Charitonidis,
F. Cindolo,
G. Collazuol,
E. Conti,
F. Dal Corso,
C. Delogu,
G. De Rosa,
A. Falcone,
A. Gola,
C. Jollet,
V. Kain,
B. Klicek,
Y. Kudenko,
M. Laveder
, et al. (34 additional authors not shown)
Abstract:
The uncertainty in the initial neutrino flux is the main limitation for a precise determination of the absolute neutrino cross section. The ERC funded ENUBET project (2016-2021) is studying a facility based on a narrow band beam to produce an intense source of electron neutrinos with a ten-fold improvement in accuracy. Since March 2019 ENUBET is also a Neutrino Platform experiment at CERN: NP06/EN…
▽ More
The uncertainty in the initial neutrino flux is the main limitation for a precise determination of the absolute neutrino cross section. The ERC funded ENUBET project (2016-2021) is studying a facility based on a narrow band beam to produce an intense source of electron neutrinos with a ten-fold improvement in accuracy. Since March 2019 ENUBET is also a Neutrino Platform experiment at CERN: NP06/ENUBET. A key element of the project is the instrumentation of the decay tunnel to monitor large angle positrons produced together with $ν_e$ in the three body decays of kaons ($K_{e3}$) and to discriminate them from neutral and charged pions. The need for an efficient and high purity e/$π$ separation over a length of several meters, and the requirements for fast response and radiation hardness imposed by the harsh beam environment, suggested the implementation of a longitudinally segmented Fe/scintillator calorimeter with a readout based on WLS fibers and SiPM detectors. An extensive experimental program through several test beam campaigns at the CERN-PS T9 beam line has been pursued on calorimeter prototypes, both with a shashlik and a lateral readout configuration. The latter, in which fibers collect the light from the side of the scintillator tiles, allows to place the light sensors away from the core of the calorimeter, thus reducing possible irradiation damages with respect to the shashlik design. This contribution will present the achievements of the prototyping activities carried out, together with irradiation tests made on the Silicon Photo-Multipliers. The results achieved so far pin down the technology of choice for the construction of the 3 m long demonstrator that will take data in 2021.
△ Less
Submitted 6 April, 2020;
originally announced April 2020.
-
Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon
Authors:
The DarkSide Collaboration,
C. E. Aalseth,
S. Abdelhakim,
F. Acerbi,
P. Agnes,
R. Ajaj,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
F. Ameli,
J. Anstey,
P. Antonioli,
M. Arba,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
P. Arpaia,
D. M. Asner,
A. Asunskis,
M. Ave,
H. O. Back,
A. Barrado Olmedo,
G. Batignani
, et al. (306 additional authors not shown)
Abstract:
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioa…
▽ More
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, $^{39}$Ar, a $β$ emitter of cosmogenic origin. For large detectors, the atmospheric $^{39}$Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of $^{39}$Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of $^{39}$Ar with respect to AAr by a factor larger than 1400. Assessing the $^{39}$Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly $γ$-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.
△ Less
Submitted 22 January, 2020;
originally announced January 2020.
-
Polysiloxane-based scintillators for shashlik calorimeters
Authors:
F. Acerbi,
A. Branca,
C. Brizzolari,
G. Brunetti,
S. Carturan,
M. G. Catanesi,
S. Cecchini,
F. Cindolo,
G. Collazuol,
F. Dal Corso,
G. De Rosa,
C. Delogu,
A. Falcone,
A. Gola,
C. Jollet,
B. Kliček,
Y. Kudenko,
M. Laveder,
A. Longhin,
L. Ludovici,
E. Lutsenko,
L. Magaletti,
G. Mandrioli,
T. Marchi,
A. Margotti
, et al. (24 additional authors not shown)
Abstract:
We present the first application of polysiloxane-based scintillators as active medium in a shashlik sampling calorimeter. These results were obtained from a testbeam campaign of a $\sim$6$\times$6$\times$45 cm$^3$ (13 $X_0$ depth) prototype. A Wavelength Shifting fiber array of 36 elements runs perpendicularly to the stack of iron (15 mm) and polysiloxane scintillator (15 mm) tiles with a density…
▽ More
We present the first application of polysiloxane-based scintillators as active medium in a shashlik sampling calorimeter. These results were obtained from a testbeam campaign of a $\sim$6$\times$6$\times$45 cm$^3$ (13 $X_0$ depth) prototype. A Wavelength Shifting fiber array of 36 elements runs perpendicularly to the stack of iron (15 mm) and polysiloxane scintillator (15 mm) tiles with a density of about one over cm$^2$. Unlike shashlik calorimeters based on plastic organic scintillators, here fibers are optically matched with the scintillator without any intermediate air gap. The prototype features a compact light readout based on Silicon Photo-Multipliers embedded in the bulk of the detector. The detector was tested with electrons, pions and muons with energies ranging from 1 to 7 GeV at the CERN-PS. This solution offers a highly radiation hard detector to instrument the decay region of a neutrino beam, providing an event-by-event measurement of high-angle decay products associated with neutrino production (ENUBET, Enhanced NeUtrino BEams from kaon Tagging, ERC project). The results in terms of light yield, uniformity and energy resolution, are compared to a similar calorimeter built with ordinary plastic scintillators.
△ Less
Submitted 9 January, 2020;
originally announced January 2020.
-
Photometric light curve solutions of three ultra-short period eclipsing binaries
Authors:
F. Acerbi,
R. Michel,
C. Barani,
M. Martignoni,
L. Fox-Machado
Abstract:
We present the results of our study of the eclipsing binary systems CSS J112237.1+395219, LINEAR 1286561 and LINEAR 2602707 based on new CCD $B$, $V$, $R_c$ and $I_c$ complete light curves. The ultra-short period nature of the stars \citep{Drake2014} is confirmed and the system's periods are revised. The light curves were modelled using the 2005 version of the Wilson-Devinney code. When necessary,…
▽ More
We present the results of our study of the eclipsing binary systems CSS J112237.1+395219, LINEAR 1286561 and LINEAR 2602707 based on new CCD $B$, $V$, $R_c$ and $I_c$ complete light curves. The ultra-short period nature of the stars \citep{Drake2014} is confirmed and the system's periods are revised. The light curves were modelled using the 2005 version of the Wilson-Devinney code. When necessary, cool spots on the surface of the primary component were introduced to account for asymmetries in the light curves. As a result, we found that CSS J112237.1+395219 is a W UMa type contact binary system belonging to W subclass with a mass ratio of $q=1.61$ and a shallow degree of contact of 14.8\% where the primary component is hotter than the secondary one by $500K$. LINEAR 1286561 and LINEAR 2602707 are detached binary systems with mass ratios $q=3.467$ and $q=0.987$ respectively. These detached systems are low-mass M-type eclipsing binaries of similar temperatures. The marginal contact, the fill-out factor and the temperature difference between components of CSS J112237.1+395219 suggest that this system may be at a key evolutionary state predicted by the Thermal Relaxation Oscillation theory (TRO). From the estimated absolute parameters we conclude that our systems share common properties with others ultra-short period binaries.
△ Less
Submitted 26 November, 2019;
originally announced November 2019.
-
The ENUBET narrow band neutrino beam
Authors:
ENUBET Collaboration,
M. Tenti,
F. Acerbi,
G. Ballerini,
M. Bonesini,
C. Brizzolari,
G. Brunetti M. Calviani,
S. Carturan,
M. G. Catanesi,
S. Cecchini,
F. Cindolo,
G. Collazuol,
E. Conti F. Dal Corso,
G. De Rosa,
C. Delogu,
A. Falcone,
B. Goddard,
A. Gola,
R. A. Intonti,
C. Jollet,
V. Kain,
B. Klicek,
Y. Kudenko,
M. Laveder,
A. Longhin
, et al. (32 additional authors not shown)
Abstract:
The narrow band beam of ENUBET is the first implementation of the "monitored neutrino beam" technique proposed in 2015. ENUBET has been designed to monitor lepton production in the decay tunnel of neutrino beams and to provide a 1% measurement of the neutrino flux at source. In particular, the three body semi-leptonic decay of kaons monitored by large angle positron production offers a fully contr…
▽ More
The narrow band beam of ENUBET is the first implementation of the "monitored neutrino beam" technique proposed in 2015. ENUBET has been designed to monitor lepton production in the decay tunnel of neutrino beams and to provide a 1% measurement of the neutrino flux at source. In particular, the three body semi-leptonic decay of kaons monitored by large angle positron production offers a fully controlled $ν_{e}$ source at the GeV scale for a new generation of short baseline experiments. In this contribution the performances of the positron tagger prototypes tested at CERN beamlines in 2016-2018 are presented.
△ Less
Submitted 27 March, 2019;
originally announced March 2019.
-
The ENUBET Beamline
Authors:
ENUBET Collaboration,
G. Brunetti,
F. Acerbi,
G. Ballerini,
M. Bonesini,
A. Branca,
C. Brizzolari,
M. Calviani,
S. Carturan,
M. G. Catanesi,
S. Cecchini,
F. Cindolo,
G. Collazuol,
E. Conti,
F. Dal Corso,
G. De Rosa,
C. Delogu,
A. Falcone,
B. Goddard,
A. Gola,
R. A. Intonti,
C. Jollet,
V. Kain,
B. Klicek,
Y. Kudenko
, et al. (34 additional authors not shown)
Abstract:
The ENUBET ERC project (2016-2021) is studying a narrow band neutrino beam where lepton production can be monitored at single particle level in an instrumented decay tunnel. This would allow to measure $ν_μ$ and $ν_{e}$ cross sections with a precision improved by about one order of magnitude compared to present results. In this proceeding we describe a first realistic design of the hadron beamline…
▽ More
The ENUBET ERC project (2016-2021) is studying a narrow band neutrino beam where lepton production can be monitored at single particle level in an instrumented decay tunnel. This would allow to measure $ν_μ$ and $ν_{e}$ cross sections with a precision improved by about one order of magnitude compared to present results. In this proceeding we describe a first realistic design of the hadron beamline based on a dipole coupled to a pair of quadrupole triplets along with the optimisation guidelines and the results of a simulation based on G4beamline. A static focusing design, though less efficient than a horn-based solution, results several times more efficient than originally expected. It works with slow proton extractions reducing drastically pile-up effects in the decay tunnel and it paves the way towards a time-tagged neutrino beam. On the other hand a horn-based transferline would ensure higher yields at the tunnel entrance. The first studies conducted at CERN to implement the synchronization between a few ms proton extraction and a horn pulse of 2-10 ms are also described.
△ Less
Submitted 26 November, 2020; v1 submitted 21 March, 2019;
originally announced March 2019.
-
Multicolor study of V1009 Per, a close binary system at the beginning of the overcontact phase, and of CRTS J031642.2+332639, a new binary system in the same field
Authors:
Raul Michel,
Francesco Acerbi,
Carlo Barani,
Massimiliano Martignoni
Abstract:
The first multicolor observations, and light curve solutions, of the eclipsing binary systems V1009~Per and CRTS~J031642.2+332639 are presented. Using the 2005 version of the Wilson-Devinney code, both systems are found to be W UMa contact binaries. V1009~Per has a mass ratio of $q = 0.362 \pm 0.002$ and a shallow fill out parameter of $f = 11.8 \pm 0.6\%$ while CRTS~J031642.2+332639 has a mass ra…
▽ More
The first multicolor observations, and light curve solutions, of the eclipsing binary systems V1009~Per and CRTS~J031642.2+332639 are presented. Using the 2005 version of the Wilson-Devinney code, both systems are found to be W UMa contact binaries. V1009~Per has a mass ratio of $q = 0.362 \pm 0.002$ and a shallow fill out parameter of $f = 11.8 \pm 0.6\%$ while CRTS~J031642.2+332639 has a mass ratio of $q=2.507 \pm0.006$ and a fill out of $f= 13.6 \pm0.4\%$. High orbital inclinations, $i = 85^\circ.9$ for V1009 Per and $i = 83^\circ.2$ for CRTS~J031642.2+332639, implies that both systems are total eclipsing binaries and that the photometric parameters here obtained are reliable. Based on 16 times of minimum, the orbital period variations of V1009~Per are discussed.
%The estimated physical parameters of V1009 Per are $M_1 = 0.874M_\odot, M_2 = 0.317M_\odot, R_1 = 0.865R_\odot, R_2 = 0.474R_\odot, L_1 = 0.521L_\odot, L_2 = 0.153L_\odot$. For CRTS J031642.2+332639, the physical parameters are $M_1 = 1.037M_\odot, M_2 = 0.414M_\odot, R_1 = 1.002R_\odot, R_2 = 0.661R_\odot, L_1 = 0.770L_\odot, L_2 = 0.370L_\odot$.
The absolute dimensions of the systems are estimated and, from the logM-logL diagram, it is found that both components of the systems follow the general pattern of the W subtype W Ursae Majoris systems.
△ Less
Submitted 11 February, 2019;
originally announced February 2019.
-
Irradiation and performance of RGB-HD Silicon Photomultipliers for calorimetric applications
Authors:
F. Acerbi,
G. Ballerini,
A. Berra,
C. Brizzolari,
G. Brunetti,
M. G. Catanesi,
S. Cecchini,
F. Cindolo,
A. Coffani,
G. Collazuol,
E. Conti,
F. Dal Corso,
C. Delogu,
G. De Rosa,
A. Gola,
R. A. Intonti,
C. Jollet,
Y. Kudenko,
A. Longhin,
L. Ludovici,
L. Magaletti,
G. Mandrioli,
A. Margotti,
V. Mascagna,
N. Mauri
, et al. (19 additional authors not shown)
Abstract:
Silicon Photomultipliers with cell-pitch ranging from 12 $μ$m to 20 $μ$m were tested against neutron irradiation at moderate fluences to study their performance for calorimetric applications. The photosensors were developed by FBK employing the RGB-HD technology. We performed irradiation tests up to $2 \times 10^{11}$ n/cm$^2$ (1 MeV eq.) at the INFN-LNL Irradiation Test facility. The SiPMs were c…
▽ More
Silicon Photomultipliers with cell-pitch ranging from 12 $μ$m to 20 $μ$m were tested against neutron irradiation at moderate fluences to study their performance for calorimetric applications. The photosensors were developed by FBK employing the RGB-HD technology. We performed irradiation tests up to $2 \times 10^{11}$ n/cm$^2$ (1 MeV eq.) at the INFN-LNL Irradiation Test facility. The SiPMs were characterized on-site (dark current and photoelectron response) during and after irradiations at different fluences. The irradiated SiPMs were installed in the ENUBET compact calorimetric modules and characterized with muons and electrons at the CERN East Area facility. The tests demonstrate that both the electromagnetic response and the sensitivity to minimum ionizing particles are retained after irradiation. Gain compensation can be achieved increasing the bias voltage well within the operation range of the SiPMs. The sensitivity to single photoelectrons is lost at $\sim 10^{10}$ n/cm$^2$ due to the increase of the dark current.
△ Less
Submitted 24 January, 2019;
originally announced January 2019.
-
A high precision neutrino beam for a new generation of short baseline experiments
Authors:
F. Acerbi,
G. Ballerini,
S. Bolognesi,
M. Bonesini,
C. Brizzolari,
G. Brunetti,
S. Carturan,
M. G. Catanesi,
S. Cecchini,
F. Cindolo,
G. Collazuol,
E. Conti,
F. Dal Corso,
G. De Rosa,
F. Di Lodovico,
C. Delogu,
A. Falcone,
A. Gola,
R. A. Intonti,
C. Jollet,
B. Klicek,
Y. Kudenko,
M. Laveder,
A. Longhin,
L. Ludovici
, et al. (31 additional authors not shown)
Abstract:
The current generation of short baseline neutrino experiments is approaching intrinsic source limitations in the knowledge of flux, initial neutrino energy and flavor. A dedicated facility based on conventional accelerator techniques and existing infrastructures designed to overcome these impediments would have a remarkable impact on the entire field of neutrino oscillation physics. It would impro…
▽ More
The current generation of short baseline neutrino experiments is approaching intrinsic source limitations in the knowledge of flux, initial neutrino energy and flavor. A dedicated facility based on conventional accelerator techniques and existing infrastructures designed to overcome these impediments would have a remarkable impact on the entire field of neutrino oscillation physics. It would improve by about one order of magnitude the precision on $ν_μ$ and $ν_e$ cross sections, enable the study of electroweak nuclear physics at the GeV scale with unprecedented resolution and advance searches for physics beyond the three-neutrino paradigm. In turn, these results would enhance the physics reach of the next generation long baseline experiments (DUNE and Hyper-Kamiokande) on CP violation and their sensitivity to new physics. In this document, we present the physics case and technology challenge of high precision neutrino beams based on the results achieved by the ENUBET Collaboration in 2016-2018. We also set the R&D milestones to enable the construction and running of this new generation of experiments well before the start of the DUNE and Hyper-Kamiokande data taking. We discuss the implementation of this new facility at three different level of complexity: $ν_μ$ narrow band beams, $ν_e$ monitored beams and tagged neutrino beams. We also consider a site specific implementation based on the CERN-SPS proton driver providing a fully controlled neutrino source to the ProtoDUNE detectors at CERN.
△ Less
Submitted 15 January, 2019;
originally announced January 2019.
-
DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS
Authors:
C. E. Aalseth,
F. Acerbi,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Antonioli,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
D. M. Asner,
M. Ave,
H. O. Back,
A. I. Barrado Olmedo,
G. Batignani,
E. Bertoldo,
S. Bettarini,
M. G. Bisogni,
V. Bocci,
A. Bondar,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino
, et al. (260 additional authors not shown)
Abstract:
Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a…
▽ More
Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a cylindrical Water Cherenkov Veto (WCV). Operation of DarkSide-50 demonstrated a major reduction in the dominant $^{39}$Ar background when using argon extracted from an underground source, before applying pulse shape analysis. Data from DarkSide-50, in combination with MC simulation and analytical modeling, shows that a rejection factor for discrimination between electron and nuclear recoils of $\gt3\times10^9$ is achievable. This, along with the use of the veto system, is the key to unlocking the path to large LArTPC detector masses, while maintaining an "instrumental background-free" experiment, an experiment in which less than 0.1 events (other than $ν$-induced nuclear recoils) is expected to occur within the WIMP search region during the planned exposure. DarkSide-20k will have ultra-low backgrounds than can be measured in situ. This will give sensitivity to WIMP-nucleon cross sections of $1.2\times10^{-47}$ cm$^2$ ($1.1\times10^{-46}$ cm$^2$) for WIMPs of $1$ TeV$/c^2$ ($10$ TeV$/c^2$) mass, to be achieved during a 5 yr run producing an exposure of 100 t yr free from any instrumental background. DarkSide-20k could then extend its operation to a decade, increasing the exposure to 200 t yr, reaching a sensitivity of $7.4\times10^{-48}$ cm$^2$ ($6.9\times10^{-47}$ cm$^2$) for WIMPs of $1$ TeV$/c^2$ ($10$ TeV$/c^2$) mass.
△ Less
Submitted 25 July, 2017;
originally announced July 2017.
-
Cryogenic Characterization of FBK RGB-HD SiPMs
Authors:
C. E. Aalseth,
F. Acerbi,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Ampudia,
P. Antonioli,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
D. M. Asner,
H. O. Back,
G. Batignani,
E. Bertoldo,
S. Bettarini,
M. G. Bisogni,
V. Bocci,
A. Bondar,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
R. Bunker
, et al. (246 additional authors not shown)
Abstract:
We report on the cryogenic characterization of Red Green Blue - High Density (RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the DarkSide program of dark matter searches with liquid argon time projection chambers. A dedicated setup was used to measure the primary dark noise, the correlated noise, and the gain of the SiPMs at varying temperatures. A custom-made data acquisitio…
▽ More
We report on the cryogenic characterization of Red Green Blue - High Density (RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the DarkSide program of dark matter searches with liquid argon time projection chambers. A dedicated setup was used to measure the primary dark noise, the correlated noise, and the gain of the SiPMs at varying temperatures. A custom-made data acquisition system and analysis software were used to precisely characterize these parameters. We demonstrate that FBK RGB-HD SiPMs with low quenching resistance (RGB-HD-LR$_q$) can be operated from 40 K to 300 K with gains in the range $10^5$ to $10^6$ and noise rates on the order of a few Hz/mm$^2$.
△ Less
Submitted 12 September, 2017; v1 submitted 19 May, 2017;
originally announced May 2017.
-
Cryogenic Characterization of FBK HD Near-UV Sensitive SiPMs
Authors:
Fabio Acerbi,
Stefano Davini,
Alessandro Ferri,
Cristiano Galbiati,
Graham Giovanetti,
Alberto Gola,
George Korga,
Andrea Mandarano,
Marco Marcante,
Giovanni Paternoster,
Claudio Piemonte,
Alessandro Razeto,
Veronica Regazzoni,
Davide Sablone,
Claudio Savarese,
Gaetano Zappalá,
Nicola Zorzi
Abstract:
We report on the characterization of near-ultraviolet high density silicon photomultiplier (\SiPM) developed at Fondazione Bruno Kessler (\FBK) at cryogenic temperature. A dedicated setup was built to measure the primary dark noise and correlated noise of the \SiPMs\ between 40 and 300~K. Moreover, an analysis program and data acquisition system were developed to allow the precise characterization…
▽ More
We report on the characterization of near-ultraviolet high density silicon photomultiplier (\SiPM) developed at Fondazione Bruno Kessler (\FBK) at cryogenic temperature. A dedicated setup was built to measure the primary dark noise and correlated noise of the \SiPMs\ between 40 and 300~K. Moreover, an analysis program and data acquisition system were developed to allow the precise characterization of these parameters, some of which can vary up to 7 orders of magnitude between room temperature and 40~K. We demonstrate that it is possible to operate the \FBK\ near-ultraviolet high density \SiPMs\ at temperatures lower than 100~K with a dark rate below 0.01 cps/mm$^2$ and total correlated noise probability below 35\% at an over-voltage of 6~V. These results are relevant for the development of future cryogenic particle detectors using \SiPMs\ as photosensors.
△ Less
Submitted 29 June, 2017; v1 submitted 6 October, 2016;
originally announced October 2016.
-
SiPM and front-end electronics development for Cherenkov light detection
Authors:
G. Ambrosi,
F. Acerbi,
E. Bissaldi,
A. Ferri,
F. Giordano,
A. Gola,
M. Ionica,
R. Paoletti,
C. Piemonte,
G. Paternoster,
D. Simone,
V. Vagelli,
G. Zappala,
N. Zorzi
Abstract:
The Italian Institute of Nuclear Physics (INFN) is involved in the development of a demonstrator for a SiPM-based camera for the Cherenkov Telescope Array (CTA) experiment, with a pixel size of 6$\times$6 mm$^2$. The camera houses about two thousands electronics channels and is both light and compact. In this framework, a R&D program for the development of SiPMs suitable for Cherenkov light detect…
▽ More
The Italian Institute of Nuclear Physics (INFN) is involved in the development of a demonstrator for a SiPM-based camera for the Cherenkov Telescope Array (CTA) experiment, with a pixel size of 6$\times$6 mm$^2$. The camera houses about two thousands electronics channels and is both light and compact. In this framework, a R&D program for the development of SiPMs suitable for Cherenkov light detection (so called NUV SiPMs) is ongoing. Different photosensors have been produced at Fondazione Bruno Kessler (FBK), with different micro-cell dimensions and fill factors, in different geometrical arrangements. At the same time, INFN is developing front-end electronics based on the waveform sampling technique optimized for the new NUV SiPM. Measurements on 1$\times$1 mm$^2$, 3$\times$3 mm$^2$, and 6$\times$6 mm$^2$ NUV SiPMs coupled to the front-end electronics are presented
△ Less
Submitted 10 September, 2015;
originally announced September 2015.
-
Stellar evolution in real time: Period variations in galactic RR Lyr stars
Authors:
E. Poretti,
J. F. Le Borgne,
J. Vandenbroere,
A. Paschke,
A. Klotz,
M. Boer,
Y. Damerdji,
M. Martignoni,
F. Acerbi
Abstract:
The times of maximum brightness collected in the GEOS RR Lyr database allowed us to trace the period variations of a sample of 123 galactic RRab variables. These data span a time baseline exceeding 100 years. Clear evidence of period increases or decreases at constant rates has been found, suggesting evolutionary effects. The observed rates are slightly larger than those predicted by theoretical…
▽ More
The times of maximum brightness collected in the GEOS RR Lyr database allowed us to trace the period variations of a sample of 123 galactic RRab variables. These data span a time baseline exceeding 100 years. Clear evidence of period increases or decreases at constant rates has been found, suggesting evolutionary effects. The observed rates are slightly larger than those predicted by theoretical models; moreover, there is an unexpected large percentage of RRab stars showing a period decrease. The new possibilities offered by the use of robotic telecopes (TAROTs, REM) and of data from satellite (CoRoT) are expected to speed up the project to measure stellar evolution in real time. It is noteworthy that the outlines of this project have been sketched during several GEOS meetings, where the different knowledge of amateur and professional astronomers found a very profitable synthesis.
△ Less
Submitted 27 November, 2007;
originally announced November 2007.
-
Stellar evolution through the ages: period variations in galactic RRab stars as derived from the GEOS database and TAROT telescopes
Authors:
J. F. Le Borgne,
A. Paschke,
J. Vandenbroere,
E. Poretti,
A. Klotz,
M. Boer,
Y. Damerdji,
M. Martignoni,
F. Acerbi
Abstract:
The theory of stellar evolution can be more closely tested if we have the opportunity to measure new quantities. Nowadays, observations of galactic RR Lyr stars are available on a time baseline exceeding 100 years. Therefore, we can exploit the possibility of investigating period changes, continuing the pioneering work started by V. P. Tsesevich in 1969. We collected the available times of maxim…
▽ More
The theory of stellar evolution can be more closely tested if we have the opportunity to measure new quantities. Nowadays, observations of galactic RR Lyr stars are available on a time baseline exceeding 100 years. Therefore, we can exploit the possibility of investigating period changes, continuing the pioneering work started by V. P. Tsesevich in 1969. We collected the available times of maximum brightness of the galactic RR Lyr stars in the GEOS RR Lyr database. Moreover, we also started new observational projects, including surveys with automated telescopes, to characterise the O-C diagrams better. The database we built has proved to be a very powerful tool for tracing the period variations through the ages. We analyzed 123 stars showing a clear O-C pattern (constant, parabolic or erratic) by means of different least-squares methods. Clear evidence of period increases or decreases at constant rates has been found, suggesting evolutionary effects. The median values are beta=+0.14 day/Myr for the 27 stars showing a period increase and beta=-0.20 day/Myr for the 21 stars showing a period decrease. The large number of RR Lyr stars showing a period decrease (i.e., blueward evolution) is a new and intriguing result. There is an excess of RR Lyr stars showing large, positive $β$ values. Moreover, the observed beta values are slightly larger than those predicted by theoretical models.
△ Less
Submitted 9 October, 2007;
originally announced October 2007.