-
SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range
Authors:
The DarkSide collaboration,
C. E. Aalseth,
S. Abdelhakim,
P. Agnes,
R. Ajaj,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
F. Ameli,
J. Anstey,
P. Antonioli,
M. Arba,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
P. Arpaia,
D. M. Asner,
A. Asunskis,
M. Ave,
H. O. Back,
V. Barbaryan,
A. Barrado Olmedo,
G. Batignani
, et al. (290 additional authors not shown)
Abstract:
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the…
▽ More
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms ("neutral bremsstrahlung", NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.
△ Less
Submitted 26 February, 2021; v1 submitted 4 April, 2020;
originally announced April 2020.
-
Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon
Authors:
The DarkSide Collaboration,
C. E. Aalseth,
S. Abdelhakim,
F. Acerbi,
P. Agnes,
R. Ajaj,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
F. Ameli,
J. Anstey,
P. Antonioli,
M. Arba,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
P. Arpaia,
D. M. Asner,
A. Asunskis,
M. Ave,
H. O. Back,
A. Barrado Olmedo,
G. Batignani
, et al. (306 additional authors not shown)
Abstract:
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioa…
▽ More
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, $^{39}$Ar, a $β$ emitter of cosmogenic origin. For large detectors, the atmospheric $^{39}$Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of $^{39}$Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of $^{39}$Ar with respect to AAr by a factor larger than 1400. Assessing the $^{39}$Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly $γ$-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.
△ Less
Submitted 22 January, 2020;
originally announced January 2020.
-
Search for Zero-Neutrino Double Beta Decay in 76Ge with the Majorana Demonstrator
Authors:
C. E. Aalseth,
N. Abgrall,
E. Aguayo,
S. I. Alvis,
M. Amman,
I. J. Arnquist,
F. T. Avignone III,
H. O. Back,
A. S. Barabash,
P. S. Barbeau,
C. J. Barton,
P. J. Barton,
F. E. Bertrand,
T. Bode,
B. Bos,
M. Boswell,
R. L. Brodzinski,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
A. S. Caldwell,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson
, et al. (104 additional authors not shown)
Abstract:
The \MJ\ Collaboration is operating an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The \MJ\ \DEM\ comprises 44.1~kg of Ge detectors (29.7 kg enriched in $^{76}$Ge) split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. Here we present results from data taken during construct…
▽ More
The \MJ\ Collaboration is operating an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The \MJ\ \DEM\ comprises 44.1~kg of Ge detectors (29.7 kg enriched in $^{76}$Ge) split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. Here we present results from data taken during construction, commissioning, and the start of full operations. We achieve unprecedented energy resolution of 2.5 keV FWHM at \qval\ and a very low background with no observed candidate events in 10 kg yr of enriched Ge exposure, resulting in a lower limit on the half-life of $1.9\times10^{25}$ yr (90\% CL). This result constrains the effective Majorana neutrino mass to below 240 to 520 meV, depending on the matrix elements used. In our experimental configuration with the lowest background, the background is $4.0_{-2.5}^{+3.1}$ counts/(FWHM t yr).
△ Less
Submitted 26 March, 2018; v1 submitted 31 October, 2017;
originally announced October 2017.
-
DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS
Authors:
C. E. Aalseth,
F. Acerbi,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Antonioli,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
D. M. Asner,
M. Ave,
H. O. Back,
A. I. Barrado Olmedo,
G. Batignani,
E. Bertoldo,
S. Bettarini,
M. G. Bisogni,
V. Bocci,
A. Bondar,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino
, et al. (260 additional authors not shown)
Abstract:
Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a…
▽ More
Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a cylindrical Water Cherenkov Veto (WCV). Operation of DarkSide-50 demonstrated a major reduction in the dominant $^{39}$Ar background when using argon extracted from an underground source, before applying pulse shape analysis. Data from DarkSide-50, in combination with MC simulation and analytical modeling, shows that a rejection factor for discrimination between electron and nuclear recoils of $\gt3\times10^9$ is achievable. This, along with the use of the veto system, is the key to unlocking the path to large LArTPC detector masses, while maintaining an "instrumental background-free" experiment, an experiment in which less than 0.1 events (other than $ν$-induced nuclear recoils) is expected to occur within the WIMP search region during the planned exposure. DarkSide-20k will have ultra-low backgrounds than can be measured in situ. This will give sensitivity to WIMP-nucleon cross sections of $1.2\times10^{-47}$ cm$^2$ ($1.1\times10^{-46}$ cm$^2$) for WIMPs of $1$ TeV$/c^2$ ($10$ TeV$/c^2$) mass, to be achieved during a 5 yr run producing an exposure of 100 t yr free from any instrumental background. DarkSide-20k could then extend its operation to a decade, increasing the exposure to 200 t yr, reaching a sensitivity of $7.4\times10^{-48}$ cm$^2$ ($6.9\times10^{-47}$ cm$^2$) for WIMPs of $1$ TeV$/c^2$ ($10$ TeV$/c^2$) mass.
△ Less
Submitted 25 July, 2017;
originally announced July 2017.
-
Cryogenic Characterization of FBK RGB-HD SiPMs
Authors:
C. E. Aalseth,
F. Acerbi,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Ampudia,
P. Antonioli,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
D. M. Asner,
H. O. Back,
G. Batignani,
E. Bertoldo,
S. Bettarini,
M. G. Bisogni,
V. Bocci,
A. Bondar,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
R. Bunker
, et al. (246 additional authors not shown)
Abstract:
We report on the cryogenic characterization of Red Green Blue - High Density (RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the DarkSide program of dark matter searches with liquid argon time projection chambers. A dedicated setup was used to measure the primary dark noise, the correlated noise, and the gain of the SiPMs at varying temperatures. A custom-made data acquisitio…
▽ More
We report on the cryogenic characterization of Red Green Blue - High Density (RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the DarkSide program of dark matter searches with liquid argon time projection chambers. A dedicated setup was used to measure the primary dark noise, the correlated noise, and the gain of the SiPMs at varying temperatures. A custom-made data acquisition system and analysis software were used to precisely characterize these parameters. We demonstrate that FBK RGB-HD SiPMs with low quenching resistance (RGB-HD-LR$_q$) can be operated from 40 K to 300 K with gains in the range $10^5$ to $10^6$ and noise rates on the order of a few Hz/mm$^2$.
△ Less
Submitted 12 September, 2017; v1 submitted 19 May, 2017;
originally announced May 2017.
-
A Low-noise Germanium Ionization Spectrometer for Low-background Science
Authors:
Craig E. Aalseth,
Juan I. Collar,
Jim Colaresi,
James E. Fast,
Todd W. Hossbach,
John L. Orrell,
Cory T. Overman,
Bjorn Scholz,
Brent A. VanDevender,
K. Michael Yocum
Abstract:
Recent progress on the development of very low noise high purity germanium ionization spectrometers has produced an instrument of 1.2 kg mass and excellent noise performance. The detector was installed in a low-background cryostat intended for use in a direct detection search for low mass, WIMP dark matter. This Transaction reports the thermal characterization of the cryostat, specifications of th…
▽ More
Recent progress on the development of very low noise high purity germanium ionization spectrometers has produced an instrument of 1.2 kg mass and excellent noise performance. The detector was installed in a low-background cryostat intended for use in a direct detection search for low mass, WIMP dark matter. This Transaction reports the thermal characterization of the cryostat, specifications of the newly prepared 1.2 kg p-type point contact germanium detector, and the spectroscopic performance of the integrated system. The integrated detector and low background cryostat achieved full-width-at-half-maximum noise performance of 98 eV for an electronic pulse generator peak and 1.9 keV for the 1332 keV Co-60 gamma ray.
△ Less
Submitted 4 March, 2016;
originally announced March 2016.
-
Development of a low-level Ar-37 calibration standard
Authors:
R. M. Williams,
C. E. Aalseth,
T. W. Bowyer,
A. R. Day,
E. S. Fuller,
D. A. Haas,
J. C. Hayes,
E. W. Hoppe,
P. H. Humble,
M. E. Keillor,
B. D. LaFerriere,
E. K. Mace,
J. I. McIntyre,
H. S. Miley,
A. W. Myers,
J. L. Orrell,
C. T. Overman,
M. E. Panisko,
A. Seifert
Abstract:
Argon-37 is an environmental signature of an underground nuclear explosion. Producing and quantifying low-level Ar-37 standards is an important step in the development of sensitive field measurement instruments. This paper describes progress at Pacific Northwest National Laboratory in developing a process to generate and quantify low-level Ar-37 standards, which can be used to calibrate sensitive…
▽ More
Argon-37 is an environmental signature of an underground nuclear explosion. Producing and quantifying low-level Ar-37 standards is an important step in the development of sensitive field measurement instruments. This paper describes progress at Pacific Northwest National Laboratory in developing a process to generate and quantify low-level Ar-37 standards, which can be used to calibrate sensitive field systems at activities consistent with soil background levels. This paper presents a discussion of the measurement analysis, along with assumptions and uncertainty estimates.
△ Less
Submitted 4 March, 2016;
originally announced March 2016.
-
Shielding concepts for low-background proportional counter arrays in surface laboratories
Authors:
Craig E. Aalseth,
Paul H. Humble,
Emily K. Mace,
John L. Orrell,
Allen Seifert,
Richard M. Williams
Abstract:
Development of ultra low background gas proportional counters has made the contribution from naturally occurring radioactive isotopes -- primarily $α$ and $β$ activity in the uranium and thorium decay chains -- inconsequential to instrumental sensitivity levels when measurements are performed in above ground surface laboratories. Simple lead shielding is enough to mitigate against gamma rays as ga…
▽ More
Development of ultra low background gas proportional counters has made the contribution from naturally occurring radioactive isotopes -- primarily $α$ and $β$ activity in the uranium and thorium decay chains -- inconsequential to instrumental sensitivity levels when measurements are performed in above ground surface laboratories. Simple lead shielding is enough to mitigate against gamma rays as gas proportional counters are already relatively insensitive to naturally occurring gamma radiation. The dominant background in these surface laboratory measurements using ultra low background gas proportional counters is due to cosmic ray generated muons, neutrons, and protons. Studies of measurements with ultra low background gas proportional counters in surface and underground laboratories as well as radiation transport Monte Carlo simulations suggest a preferred conceptual design to achieve the highest possible sensitivity from an array of low background gas proportional counters when operated in a surface laboratory. The basis for a low background gas proportional counter array and the preferred shielding configuration is reported, especially in relation to measurements of radioactive gases having low energy decays such as $^{37}$Ar.
△ Less
Submitted 23 December, 2015;
originally announced December 2015.
-
Assay methods for U-238, Th-232, and Pb-210 in lead and calibration of Bi-210 bremsstrahlung emission from lead
Authors:
John L. Orrell,
Craig E. Aalseth,
Isaac J. Arnquist,
Tere A. Eggemeyer,
Brian D. Glasgow,
Eric W. Hoppe,
Martin E. Keillor,
Shannon M. Morley,
Allan W. Myers,
Cory T. Overman,
Sarah M. Shaff,
Kimbrelle S. Thommasson
Abstract:
Assay methods for measuring 238U, 232Th, and 210Pb concentrations in refined lead are presented. The 238U and 232Th concentrations are determined using isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) after anion exchange column separation of dissolved lead samples. The 210Pb concentration is inferred through α-spectroscopy of a daughter isotope, 210Po, after chemical prec…
▽ More
Assay methods for measuring 238U, 232Th, and 210Pb concentrations in refined lead are presented. The 238U and 232Th concentrations are determined using isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) after anion exchange column separation of dissolved lead samples. The 210Pb concentration is inferred through α-spectroscopy of a daughter isotope, 210Po, after chemical precipitation separation on dissolved lead samples. Subsequent to the 210Po α-spectroscopy assay, a method for evaluating 210Pb concentrations in solid lead samples was developed via measurement of bremsstrahlung radiation from \b{eta}-decay of a daughter isotope, 210Bi, by employing a 14-crystal array of high purity germanium (HPGe) detectors. Ten sources of refined lead were assayed. The 238U concentrations were <34 microBq/kg and the 232Th concentrations ranged <0.6-15 microBq/kg, as determined by the ICP-MS assay method. The 210Pb concentrations ranged from ~0.1-75 Bq/kg, as inferred by the 210Po α-spectroscopy assay method.
△ Less
Submitted 21 December, 2015;
originally announced December 2015.
-
Development of a low background liquid scintillation counter for a shallow underground laboratory
Authors:
J. L. Erchinger,
C. E. Aalseth,
B. E. Bernacki,
M. Douglas,
E. S. Fuller,
M. E. Keillor,
S. M. Morley,
C. A. Mullen,
J. L. Orrell,
M. E. Panisko,
G. A. Warren,
R. O. Williams,
M. E. Wright
Abstract:
Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of low-concentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillati…
▽ More
Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of low-concentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillation counting is especially useful for measuring charged particle (e.g., $β$, $α$) emitting isotopes with no (or very weak) gamma-ray yields. The combination of high-efficiency detection of charged particle emission in a liquid scintillation cocktail coupled with the low-background environment of an appropriately-designed shield located in a clean underground laboratory provides the opportunity for increased-sensitivity measurements of a range of isotopes. To take advantage of the 35 meters-water-equivalent overburden of the underground laboratory, a series of simulations have evaluated the scintillation counter's shield design requirements to assess the possible background rate achievable. This report presents the design and background evaluation for a shallow underground, low background liquid scintillation counter design for sample measurements.
△ Less
Submitted 20 December, 2015;
originally announced December 2015.
-
Maximum Likelihood Signal Extraction Method Applied to 3.4 years of CoGeNT Data
Authors:
C. E. Aalseth,
P. S. Barbeau,
J. Diaz Leon,
J. E. Fast,
T. W. Hossbach,
A. Knecht,
M. S. Kos,
M. G. Marino,
H. S. Miley,
M. L. Miller,
J. L. Orrell
Abstract:
CoGeNT has taken data for over 3 years, with 1136 live days of data accumulated as of April 23, 2013. We report on the results of a maximum likelihood analysis to extract any possible dark matter signal present in the collected data. The maximum likelihood signal extraction uses 2-dimensional probability density functions (PDFs) to characterize the anticipated variations in dark matter interaction…
▽ More
CoGeNT has taken data for over 3 years, with 1136 live days of data accumulated as of April 23, 2013. We report on the results of a maximum likelihood analysis to extract any possible dark matter signal present in the collected data. The maximum likelihood signal extraction uses 2-dimensional probability density functions (PDFs) to characterize the anticipated variations in dark matter interaction rates for given observable nuclear recoil energies during differing periods of the Earth's annual orbit around the Sun. Cosmogenic and primordial radioactivity backgrounds are characterized by their energy signatures and in some cases decay half-lives. A third parameterizing variable -- pulse rise-time -- is added to the likelihood analysis to characterize slow rising pulses described in prior analyses. The contribution to each event category is analyzed for various dark matter signal hypotheses including a dark matter standard halo model and a case with free oscillation parameters (i.e., amplitude, period, and phase). The best-fit dark matter signal is in close proximity to previously reported results. We find that the significance of the extracted dark matter signal remains well below evidentiary at 1.7 $σ$.
△ Less
Submitted 5 February, 2015; v1 submitted 23 January, 2014;
originally announced January 2014.
-
Search for An Annual Modulation in Three Years of CoGeNT Dark Matter Detector Data
Authors:
C. E. Aalseth,
P. S. Barbeau,
J. Colaresi,
J. I. Collar,
J. Diaz Leon,
J. E. Fast,
N. E. Fields,
T. W. Hossbach,
A. Knecht,
M. S. Kos,
M. G. Marino,
H. S. Miley,
M. L. Miller,
J. L. Orrell,
K. M. Yocum
Abstract:
Weakly Interacting Massive Particles (WIMPs) are well-established dark matter candidates. WIMP interactions with sensitive detectors are expected to display a characteristic annual modulation in rate. We release a dataset spanning 3.4 years of operation from a low-background germanium detector, designed to search for this signature. A previously reported modulation persists, concentrated in a regi…
▽ More
Weakly Interacting Massive Particles (WIMPs) are well-established dark matter candidates. WIMP interactions with sensitive detectors are expected to display a characteristic annual modulation in rate. We release a dataset spanning 3.4 years of operation from a low-background germanium detector, designed to search for this signature. A previously reported modulation persists, concentrated in a region of the energy spectrum populated by an exponential excess of unknown origin. Its phase and period agree with phenomenological expectations, but its amplitude is a factor $\sim$4-7 larger than predicted for a standard WIMP galactic halo. We consider the possibility of a non-Maxwellian local halo velocity distribution as a plausible explanation, able to help reconcile recently reported WIMP search anomalies.
△ Less
Submitted 14 January, 2014;
originally announced January 2014.
-
A Segmented, Enriched N-type Germanium Detector for Neutrinoless Double Beta-Decay Experiments
Authors:
L. E. Leviner,
C. E. Aalseth,
M. W. Ahmed,
F. T. Avignone III,
H. O. Back,
A. S. Barabash,
M. Boswell,
L. De Braeckeleer,
V. B. Brudanin,
Y-D Chan,
V. G. Egorov,
S. R. Elliott,
V. M. Gehman,
T. W. Hossbach,
J. D. Kephart,
M. F. Kidd,
S. I. Konovalov,
K. T. Lesko,
Jingyi Li,
D-M Mei,
S. Mikhailov,
H. Miley,
D. C. Radford,
J. Reeves,
V. G. Sandukovsky
, et al. (5 additional authors not shown)
Abstract:
We present data characterizing the performance of the first segmented, N-type Ge detector, isotopically enriched to 85% $^{76}$Ge. This detector, based on the Ortec PT6x2 design and referred to as SEGA (Segmented, Enriched Germanium Assembly), was developed as a possible prototype for neutrinoless double beta-decay measurements by the {\sc Majorana} collaboration. We present some of the general ch…
▽ More
We present data characterizing the performance of the first segmented, N-type Ge detector, isotopically enriched to 85% $^{76}$Ge. This detector, based on the Ortec PT6x2 design and referred to as SEGA (Segmented, Enriched Germanium Assembly), was developed as a possible prototype for neutrinoless double beta-decay measurements by the {\sc Majorana} collaboration. We present some of the general characteristics (including bias potential, efficiency, leakage current, and integral cross-talk) for this detector in its temporary cryostat. We also present an analysis of the resolution of the detector, and demonstrate that for all but two segments there is at least one channel that reaches the {\sc Majorana} resolution goal below 4 keV FWHM at 2039 keV, and all channels are below 4.5 keV FWHM.
△ Less
Submitted 19 April, 2013;
originally announced April 2013.
-
Cryostat for Ultra-low-energy Threshold Germanium Spectrometers
Authors:
Craig E. Aalseth,
Ricco M. Bonicalzi,
James E. Fast,
Todd W. Hossbach,
John L. Orrell,
Cory T. Overman,
Brent A. Vandevender
Abstract:
This paper presents progress on the development of a cryostat intended to improve upon the low-energy threshold (below 0.5 keV) of p-type point contact germanium gamma-ray spectrometers. Ultra-low energy thresholds are important in the detection of low-energy nuclear recoils, an event class relevant to both dark matter direct detection and measurement of coherent neutrino-nucleus scattering. The c…
▽ More
This paper presents progress on the development of a cryostat intended to improve upon the low-energy threshold (below 0.5 keV) of p-type point contact germanium gamma-ray spectrometers. Ultra-low energy thresholds are important in the detection of low-energy nuclear recoils, an event class relevant to both dark matter direct detection and measurement of coherent neutrino-nucleus scattering. The cryostat design, including a thermal and electrical-field model, is given. A prototype cryostat has been assembled and data acquired to evaluate its vacuum and thermal performance.
△ Less
Submitted 8 October, 2012;
originally announced October 2012.
-
CoGeNT: A Search for Low-Mass Dark Matter using p-type Point Contact Germanium Detectors
Authors:
C. E. Aalseth,
P. S. Barbeau,
J. Colaresi,
J. I. Collar,
J. Diaz Leon,
J. E. Fast,
N. E. Fields,
T. W. Hossbach,
A. Knecht,
M. S. Kos,
M. G. Marino,
H. S. Miley,
M. L. Miller,
J. L. Orrell,
K. M. Yocum
Abstract:
CoGeNT employs p-type point-contact (PPC) germanium detectors to search for Weakly Interacting Massive Particles (WIMPs). By virtue of its low energy threshold and ability to reject surface backgrounds, this type of device allows an emphasis on low-mass dark matter candidates (wimp mass of about 10 GeV/c2). We report on the characteristics of the PPC detector presently taking data at the Soudan Un…
▽ More
CoGeNT employs p-type point-contact (PPC) germanium detectors to search for Weakly Interacting Massive Particles (WIMPs). By virtue of its low energy threshold and ability to reject surface backgrounds, this type of device allows an emphasis on low-mass dark matter candidates (wimp mass of about 10 GeV/c2). We report on the characteristics of the PPC detector presently taking data at the Soudan Underground Laboratory, elaborating on aspects of shielding, data acquisition, instrumental stability, data analysis, and background estimation. A detailed background model is used to investigate the low energy excess of events previously reported, and to assess the possibility of temporal modulations in the low-energy event rate. Extensive simulations of all presently known backgrounds do not provide a viable background explanation for the excess of low-energy events in the CoGeNT data, or the previously observed temporal variation in the event rate. Also reported on for the first time is a determination of the surface (slow pulse rise time) event contamination in the data as a function of energy. We conclude that the CoGeNT detector technology is well suited to search for the annual modulation signature expected from dark matter particle interactions in the region of WIMP mass and coupling favored by the DAMA/LIBRA results
△ Less
Submitted 29 April, 2013; v1 submitted 28 August, 2012;
originally announced August 2012.
-
Search for an Annual Modulation in a P-type Point Contact Germanium Dark Matter Detector
Authors:
C. E. Aalseth,
P. S. Barbeau,
J. Colaresi,
J. I. Collar,
J. Diaz Leon,
J. E. Fast,
N. Fields,
T. W. Hossbach,
M. E. Keillor,
J. D. Kephart,
A. Knecht,
M. G. Marino,
H. S. Miley,
M. L. Miller,
J. L. Orrell,
D. C. Radford,
J. F. Wilkerson,
K. M. Yocum
Abstract:
Fifteen months of cumulative CoGeNT data are examined for indications of an annual modulation, a predicted signature of Weakly Interacting Massive Particle (WIMP) interactions. Presently available data support the presence of a modulated component of unknown origin, with parameters prima facie compatible with a galactic halo composed of light-mass WIMPs. Unoptimized estimators yield a statistical…
▽ More
Fifteen months of cumulative CoGeNT data are examined for indications of an annual modulation, a predicted signature of Weakly Interacting Massive Particle (WIMP) interactions. Presently available data support the presence of a modulated component of unknown origin, with parameters prima facie compatible with a galactic halo composed of light-mass WIMPs. Unoptimized estimators yield a statistical significance for a modulation of ~2.8 sigma, limited by the short exposure.
△ Less
Submitted 4 October, 2011; v1 submitted 3 June, 2011;
originally announced June 2011.
-
Measurement of 37Ar to support technology for On-site Inspection under the Comprehensive Nuclear-Test-Ban Treaty
Authors:
C. E. Aalseth,
A. R. Day,
D. A. Haas,
E. W. Hoppe,
B. J. Hyronimus,
M. E. Keillor,
E. K. Mace,
J. L. Orrell,
A. Seifert,
V. T. Woods
Abstract:
On-Site Inspection (OSI) is a key component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Measurements of radionuclide isotopes created by an underground nuclear explosion are a valuable signature of a Treaty violation. Argon-37 is produced from neutron interaction with calcium in soil, 40Ca(n,α)37Ar. For OSI, the 35-day half-life of 37Ar provides both high speci…
▽ More
On-Site Inspection (OSI) is a key component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Measurements of radionuclide isotopes created by an underground nuclear explosion are a valuable signature of a Treaty violation. Argon-37 is produced from neutron interaction with calcium in soil, 40Ca(n,α)37Ar. For OSI, the 35-day half-life of 37Ar provides both high specific activity and sufficient time for completion of an inspection before decay limits sensitivity. This paper presents a low-background internal-source gas proportional counter with an 37Ar measurement sensitivity level equivalent to 45.1 mBq/SCM in whole air.
△ Less
Submitted 4 August, 2010;
originally announced August 2010.
-
Astroparticle Physics with a Customized Low-Background Broad Energy Germanium Detector
Authors:
MAJORANA Collaboration,
C. E. Aalseth,
M. Amman,
F. T. Avignone III,
H. O. Back,
A. S. Barabash,
P. S. Barbeau,
M. Bergevin,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
W. Bugg,
T. H. Burritt,
M. Busch,
G. Capps,
Y-D. Chan,
J. I. Collar,
R. J. Cooper,
R. Creswick,
J. A. Detwiler,
J. Diaz,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri
, et al. (78 additional authors not shown)
Abstract:
The MAJORANA Collaboration is building the MAJORANA DEMONSTRATOR, a 60 kg array of high purity germanium detectors housed in an ultra-low background shield at the Sanford Underground Laboratory in Lead, SD. The MAJORANA DEMONSTRATOR will search for neutrinoless double-beta decay of 76Ge while demonstrating the feasibility of a tonne-scale experiment. It may also carry out a dark matter search in t…
▽ More
The MAJORANA Collaboration is building the MAJORANA DEMONSTRATOR, a 60 kg array of high purity germanium detectors housed in an ultra-low background shield at the Sanford Underground Laboratory in Lead, SD. The MAJORANA DEMONSTRATOR will search for neutrinoless double-beta decay of 76Ge while demonstrating the feasibility of a tonne-scale experiment. It may also carry out a dark matter search in the 1-10 GeV/c^2 mass range. We have found that customized Broad Energy Germanium (BEGe) detectors produced by Canberra have several desirable features for a neutrinoless double-beta decay experiment, including low electronic noise, excellent pulse shape analysis capabilities, and simple fabrication. We have deployed a customized BEGe, the MAJORANA Low-Background BEGe at Kimballton (MALBEK), in a low-background cryostat and shield at the Kimballton Underground Research Facility in Virginia. This paper will focus on the detector characteristics and measurements that can be performed with such a radiation detector in a low-background environment.
△ Less
Submitted 20 July, 2010; v1 submitted 19 July, 2010;
originally announced July 2010.
-
Results from a Search for Light-Mass Dark Matter with a P-type Point Contact Germanium Detector
Authors:
C. E. Aalseth,
P. S. Barbeau,
N. S. Bowden,
B. Cabrera-Palmer,
J. Colaresi,
J. I. Collar,
S. Dazeley,
P. de Lurgio,
G. Drake,
J. E. Fast,
N. Fields,
C. H. Greenberg,
T. W. Hossbach,
M. E. Keillor,
J. D. Kephart,
M. G. Marino,
H. S. Miley,
M. L. Miller,
J. L. Orrell,
D. C. Radford,
D. Reyna,
R. G. H. Robertson,
R. L. Talaga,
O. Tench,
T. D. Van Wechel
, et al. (2 additional authors not shown)
Abstract:
We report on several features present in the energy spectrum from an ultra low-noise germanium detector operated at 2,100 m.w.e. By implementing a new technique able to reject surface events, a number of cosmogenic peaks can be observed for the first time. We discuss several possible causes for an irreducible excess of bulk-like events below 3 keVee, including a dark matter candidate common to t…
▽ More
We report on several features present in the energy spectrum from an ultra low-noise germanium detector operated at 2,100 m.w.e. By implementing a new technique able to reject surface events, a number of cosmogenic peaks can be observed for the first time. We discuss several possible causes for an irreducible excess of bulk-like events below 3 keVee, including a dark matter candidate common to the DAMA/LIBRA annual modulation effect, the hint of a signal in CDMS, and phenomenological predictions. Improved constraints are placed on a cosmological origin for the DAMA/LIBRA effect.
△ Less
Submitted 15 March, 2010; v1 submitted 25 February, 2010;
originally announced February 2010.
-
Experimental constraints on a dark matter origin for the DAMA annual modulation effect
Authors:
C. E. Aalseth,
P. S. Barbeau,
D. G. Cerdeno,
J. Colaresi,
J. I. Collar,
P. de Lurgio,
G. Drake,
J. E. Fast,
C. H. Greenberg,
T. W. Hossbach,
J. D. Kephart,
M. G. Marino,
H. S. Miley,
J. L. Orrell,
D. Reyna,
R. G. H. Robertson,
R. Talaga,
O. Tench,
T. D. Van Wechel,
J. F. Wilkerson,
K. M. Yocum
Abstract:
A claim for evidence of dark matter interactions in the DAMA experiment has been recently reinforced. We employ a new type of germanium detector to conclusively rule out a standard isothermal galactic halo of Weakly Interacting Massive Particles (WIMPs) as the explanation for the annual modulation effect leading to the claim. Bounds are similarly imposed on a suggestion that dark pseudoscalars m…
▽ More
A claim for evidence of dark matter interactions in the DAMA experiment has been recently reinforced. We employ a new type of germanium detector to conclusively rule out a standard isothermal galactic halo of Weakly Interacting Massive Particles (WIMPs) as the explanation for the annual modulation effect leading to the claim. Bounds are similarly imposed on a suggestion that dark pseudoscalars mightlead to the effect. We describe the sensitivity to light dark matter particles achievable with our device, in particular to Next-to-Minimal Supersymmetric Model candidates.
△ Less
Submitted 31 July, 2008; v1 submitted 5 July, 2008;
originally announced July 2008.
-
Real-time digital signal processor implementation of self-calibrating pulse-shape discriminator for high purity germanium
Authors:
R. Suarez,
J. L. Orrell,
C. E. Aalseth,
T. W. Hossbach,
H. S. Miley
Abstract:
Pulse-shape analysis of the ionization signals from germanium gamma-ray spectrometers is a method for obtaining information that can characterize an event beyond just the total energy deposited in the crystal. However, as typically employed, this method is data-intensive requiring the digitization, transfer, and recording of electronic signals from the spectrometer. A hardware realization of a r…
▽ More
Pulse-shape analysis of the ionization signals from germanium gamma-ray spectrometers is a method for obtaining information that can characterize an event beyond just the total energy deposited in the crystal. However, as typically employed, this method is data-intensive requiring the digitization, transfer, and recording of electronic signals from the spectrometer. A hardware realization of a real-time digital signal processor for implementing a parametric pulse shape is presented. Specifically, a previously developed method for distinguishing between single-site and multi-site gamma-ray interactions is demonstrated in an on-line digital signal processor, compared with the original off-line pulse-shape analysis routine, and shown to have no significant difference. Reduction of the amount of the recorded information per event is shown to translate into higher duty-cycle data acquisition rates while retaining the benefits of additional event characterization from pulse-shape analysis.
△ Less
Submitted 4 December, 2007;
originally announced December 2007.
-
Radial position of single-site gamma-ray interactions from a parametric pulse shape analysis of germanium detector signals
Authors:
John L. Orrell,
Craig E. Aalseth,
Matthew W. Cooper,
Jeremy D. Kephart,
Carolyn E. Seifert
Abstract:
Pulse shape analysis of germanium gamma-ray spectrometer signals can yield information on the radial position of individual gamma-ray interactions within the germanium crystal. A parametric pulse shape analysis based on calculation of moments of the reconstructed current pulses from a closed-ended coaxial germanium detector is used to preferentially select single-site gamma-ray interactions. The…
▽ More
Pulse shape analysis of germanium gamma-ray spectrometer signals can yield information on the radial position of individual gamma-ray interactions within the germanium crystal. A parametric pulse shape analysis based on calculation of moments of the reconstructed current pulses from a closed-ended coaxial germanium detector is used to preferentially select single-site gamma-ray interactions. The double escape peak events from the 2614.5 keV gamma-ray of 208-Tl are used as a training set to optimize the single-site event selection region in the pulse shape parameter space. A collimated source of 320.1 keV gamma-rays from 51-Cr is used to scan different radial positions of the same semi-coaxial germanium detector. The previously trained single-site selection region is used to preferentially identify the single-site photoelectric absorption events from the 320.1 keV full-energy peak. From the identified events, a comparison of the pulse shape parameter space distributions between different scan positions allows radial interaction location information to be collected.
△ Less
Submitted 14 March, 2007;
originally announced March 2007.
-
Operation of a high purity germanium crystal in liquid argon as a Compton suppressed radiation spectrometer
Authors:
John L. Orrell,
Craig E. Aalseth,
John F. Amsbaugh,
Peter J. Doe,
Todd W. Hossbach
Abstract:
A high purity germanium crystal was operated in liquid argon as a Compton suppressed radiation spectrometer. Spectroscopic quality resolution of less than 1% of the full-width half maximum of full energy deposition peaks was demonstrated. The construction of the small apparatus used to obtain these results is reported. The design concept is to use the liquid argon bath to both cool the germanium…
▽ More
A high purity germanium crystal was operated in liquid argon as a Compton suppressed radiation spectrometer. Spectroscopic quality resolution of less than 1% of the full-width half maximum of full energy deposition peaks was demonstrated. The construction of the small apparatus used to obtain these results is reported. The design concept is to use the liquid argon bath to both cool the germanium crystal to operating temperatures and act as a scintillating veto. The scintillation light from the liquid argon can veto cosmic-rays, external primordial radiation, and gamma radiation that does not fully deposit within the germanium crystal. This technique was investigated for its potential impact on ultra-low background gamma-ray spectroscopy. This work is based on a concept initially developed for future germanium-based neutrinoless double-beta decay experiments.
△ Less
Submitted 11 October, 2006;
originally announced October 2006.
-
The IGEX experiment revisited: a response to the critique of Klapdor-Kleingrothaus,Dietz, and Krivosheina
Authors:
C. E. Aalseth
Abstract:
This paper is a response to the article "Critical View to" the IGEX neutrinoless double-beta decay experiment..."published in Phys. Rev.D, Volume 65 (2002) 092007," by H.V.Klapdor-Kleingrothaus, A. Dietz, and I.V.Krivosheina, published as preprint hep-ph/0403056. The criticisms are confronted, and the questions raised are answered. We demonstrate that the lower limit quoted by IGEX, for the half…
▽ More
This paper is a response to the article "Critical View to" the IGEX neutrinoless double-beta decay experiment..."published in Phys. Rev.D, Volume 65 (2002) 092007," by H.V.Klapdor-Kleingrothaus, A. Dietz, and I.V.Krivosheina, published as preprint hep-ph/0403056. The criticisms are confronted, and the questions raised are answered. We demonstrate that the lower limit quoted by IGEX, for the half life of Ge-76 neutrinoless double beta decay, 1.57x10**25 y, is correct and that there was no "arithmetical error"-as claimed in the " Critical Review" article.
△ Less
Submitted 3 May, 2004; v1 submitted 27 April, 2004;
originally announced April 2004.
-
Pulse Shape Discrimination in the IGEX Experiment
Authors:
D. Gonzalez,
J. Morales,
S. Cebrian,
E. Garcia,
I. G. Irastorza,
A. Morales,
A. Ortiz de Solorzano,
J. Puimedon,
M. L. Sarsa,
J. A. Villar,
C. E. Aalseth,
F. T. Avignone III,
R. L. Brodzinski,
W. K. Hensley,
H. S. Miley,
J. H. Reeves,
I. V. Kirpichnikov,
A. A. Klimenko,
S. B. Osetrov,
A. A. Smolnikov,
A. A. Vasenko,
S. I. Vasiliev,
V. S. Pogosov,
A. G. Tamanyan
Abstract:
The IGEX experiment has been operating enriched germanium detectors in the Canfranc Underground Laboratory (Spain) in a search for the neutrinoless double decay of 76Ge. The implementation of Pulse Shape Discrimination techniques to reduce the radioactive background is described in detail. This analysis has been applied to a fraction of the IGEX data, leading to a rejection of ~60 % of their bac…
▽ More
The IGEX experiment has been operating enriched germanium detectors in the Canfranc Underground Laboratory (Spain) in a search for the neutrinoless double decay of 76Ge. The implementation of Pulse Shape Discrimination techniques to reduce the radioactive background is described in detail. This analysis has been applied to a fraction of the IGEX data, leading to a rejection of ~60 % of their background, in the region of interest (from 2 to 2.5 MeV), down to ~0.09 c/(keV kg y).
△ Less
Submitted 14 February, 2003;
originally announced February 2003.
-
Status of IGEX dark matter search at Canfranc Underground Laboratory
Authors:
I. G. Irastorza,
A. Morales,
C. E. Aalseth,
F. T. Avignone III,
R. L. Brodzinski,
J. M. Carmona,
S. Cebrian,
E. Garcia,
I. V. Kirpichnikov,
A. A. Klimenko,
G. Luzon,
H. S. Miley,
J. Morales,
A. Ortiz de Solorzano,
S. B. Osetrov,
V. S. Pogosov,
J. Puimedon,
J. H. Reeves,
M. L. Sarsa,
A. A. Smolnikov,
A. G. Tamanyan,
A. A. Vasenko,
S. I. Vasiliev,
J. A. Villar
Abstract:
One IGEX 76Ge double-beta decay detector is currently operating in the Canfranc Underground Laboratory in a search for dark matter WIMPs, through the Ge nuclear recoil produced by the WIMP elastic scattering. In this talk we report on the on-going efforts to understand and eventually reject the background at low energy. These efforts have led to the improvement of the neutron shielding and to pa…
▽ More
One IGEX 76Ge double-beta decay detector is currently operating in the Canfranc Underground Laboratory in a search for dark matter WIMPs, through the Ge nuclear recoil produced by the WIMP elastic scattering. In this talk we report on the on-going efforts to understand and eventually reject the background at low energy. These efforts have led to the improvement of the neutron shielding and to partial reduction of the background, but still the remaining events are not totally identified. A tritium contamination or muon-induced neutrons are considered as possible sources, simulations and experimental test being still under progress. According to the success of this study we comment the prospects of the experiment as well as those of its future extension, the GEDEON dark matter experiment.
△ Less
Submitted 25 November, 2002;
originally announced November 2002.
-
The Igex 76ge Neutrinoless Double-Beta Decay Experiment: Prospects for Next Generation Experiments
Authors:
C. E. Aalseth,
F. T. Avignone III,
R. L. Brodzinski,
S. Cebrian,
E. Garcia,
D. Gonzalez,
W. K. Hensley,
I. G. Irastorza,
I. V. Kirpichnikov,
A. A. Klimenko,
H. S. Miley,
A. Morales,
J. Morales,
A. Ortiz de Solorzano,
S. B. Osetrov,
V. S. Pogosov,
J. Puimedon,
J. H. Reeves,
M. L. Sarsa,
A. A. Smolnikov,
A. S. Starostin,
A. G. Tamanyan,
A. A. Vasenko,
S. I. Vasiliev,
J. A. Villar
Abstract:
The International Germanium Experiment (IGEX) has analyzed 117 mole yr of 76Ge data from its isotopically enriched (86% 76Ge) germanium detectors. Applying pulse-shape discrimination (PSD) to the more recent data, the lower bound on the half-life for neutrinoless double-beta decay of 76Ge is: $T_{1/2}(0ν)> 1.57 \times 10^{25}$ yr (90% C.L.). This corresponds to an upper bound in the Majorana neu…
▽ More
The International Germanium Experiment (IGEX) has analyzed 117 mole yr of 76Ge data from its isotopically enriched (86% 76Ge) germanium detectors. Applying pulse-shape discrimination (PSD) to the more recent data, the lower bound on the half-life for neutrinoless double-beta decay of 76Ge is: $T_{1/2}(0ν)> 1.57 \times 10^{25}$ yr (90% C.L.). This corresponds to an upper bound in the Majorana neutrino mass parameter,$<m_ν>$, between 0.33 eV and 1.35 eV, depending on the choice of theoretical nuclear matrix elements used in the analysis.
△ Less
Submitted 12 February, 2002;
originally announced February 2002.
-
Comment on "Evidence for Neutrinoless Double Beta Decay"
Authors:
C. E. Aalseth,
F. T. Avignone III,
A. Barabash,
F. Boehm,
R. L. Brodzinski,
J. I. Collar,
P. J. Doe,
H. Ejiri,
S. R. Elliott,
E. Fiorini,
R. J. Gaitskell,
G. Gratta,
R. Hazama,
K. Kazkaz,
G. S. King III,
R. T. Kouzes,
H. S. Miley,
M. K. Moe,
A. Morales,
J. Morales,
A. Piepke,
R. G. H. Robertson,
W. Tornow,
P. Vogel,
R. A. Warner
, et al. (1 additional authors not shown)
Abstract:
We comment on the recent claim for the experimental observation of neutrinoless double-beta decay. We discuss several limitations in the analysis provided in that paper and conclude that there is no basis for the presented claim.
We comment on the recent claim for the experimental observation of neutrinoless double-beta decay. We discuss several limitations in the analysis provided in that paper and conclude that there is no basis for the presented claim.
△ Less
Submitted 22 May, 2002; v1 submitted 7 February, 2002;
originally announced February 2002.
-
The Majorana Ge-76 Double-Beta Decay Project
Authors:
The Majorana Collaboration,
C. E. Aalseth,
D. Anderson,
F. T. Avignone III,
A. Barabash,
T. W. Bowyer,
R. L. Brodzinski,
V. Brudanin,
J. I. Collar,
P. J. Doe,
S. Egorov,
S. R. Elliott,
H. A. Farach,
R. Gaitskell,
D. Jordan,
O. Kochetov,
S. Konovalov,
R. Kouzes,
H. S. Miley,
W. K. Pitts,
J. H. Reeves,
R. G. H. Robertson,
V. Sandukovsky,
E. Smith,
V. Stekhanov
, et al. (7 additional authors not shown)
Abstract:
The Majorana Experiment is a next-generation Ge-76 double-beta decay search. It will employ 500 kg of Ge, isotopically enriched to 86% in Ge-76, in the form of 200 detectors in a close-packed array for high granularity. Each crystal will be electronically segmented, with each region fitted with pulse-shape analysis electronics. A half-life sensitivity is predicted of 4.2e27 y or <m_nu> < 0.02-0.…
▽ More
The Majorana Experiment is a next-generation Ge-76 double-beta decay search. It will employ 500 kg of Ge, isotopically enriched to 86% in Ge-76, in the form of 200 detectors in a close-packed array for high granularity. Each crystal will be electronically segmented, with each region fitted with pulse-shape analysis electronics. A half-life sensitivity is predicted of 4.2e27 y or <m_nu> < 0.02-0.07 eV, depending on the nuclear matrix elements used to interpret the data.
△ Less
Submitted 10 January, 2002;
originally announced January 2002.
-
Present status of IGEX dark matter search at Canfranc Underground Laboratory
Authors:
I. G. Irastorza,
A. Morales,
C. E. Aalseth,
F. T. Avignone III,
R. L. Brodzinski,
S. Cebrian,
E. Garcia,
I. V. Kirpichnikov,
A. A. Klimenko,
H. S. Miley,
J. Morales,
A. Ortiz de Solorzano,
S. B. Osetrov,
V. S. Pogosov,
J. Puimedon,
J. H. Reeves,
M. L. Sarsa,
A. A. Smolnikov,
A. G. Tamanyan,
A. A. Vasenko,
S. I. Vasiliev,
J. A. Villar
Abstract:
One IGEX 76Ge double-beta decay detector is currently operating in the Canfranc Underground Laboratory in a search for dark matter WIMPs, through the Ge nuclear recoil produced by the WIMP elastic scattering. A new exclusion plot has been derived for WIMP-nucleon spin-independent interactions. To obtain this result, 40 days of data from the IGEX detector (energy threshold 4 keV), recently collec…
▽ More
One IGEX 76Ge double-beta decay detector is currently operating in the Canfranc Underground Laboratory in a search for dark matter WIMPs, through the Ge nuclear recoil produced by the WIMP elastic scattering. A new exclusion plot has been derived for WIMP-nucleon spin-independent interactions. To obtain this result, 40 days of data from the IGEX detector (energy threshold 4 keV), recently collected, have been analyzed. These data improve the exclusion limits derived from all the other ionization germanium detectors in the mass region from 20 GeV to 200 GeV, where a WIMP supposedly responsible for the annual modulation effect reported by the DAMA experiment would be located. The new IGEX exclusion contour enters, by the first time, the DAMA region by using only raw data, with no background discrimination, and excludes its upper left part. It is also shown that with a moderate improvement of the detector performances, the DAMA region could be fully explored.
△ Less
Submitted 22 November, 2001;
originally announced November 2001.
-
Improved constraints on WIMPs from the International Germanium Experiment IGEX
Authors:
A. Morales,
C. E. Aalseth,
F. T. Avignone III,
R. L. Brodzinski,
S. Cebrian,
E. Garcia,
I. G. Irastorza,
I. V. Kirpichnikov,
A. A. Klimenko,
H. S. Miley,
J. Morales,
A. Ortiz de Solorzano,
S. B. Osetrov,
V. S. Pogosov,
J. Puimedon,
J. H. Reeves,
M. L. Sarsa,
A. A. Smolnikov,
A. G. Tamanyan,
A. A. Vasenko,
S. I. Vasiliev,
J. A. Villar
Abstract:
One IGEX 76Ge double-beta decay detector is currently operating in the Canfranc Underground Laboratory in a search for dark matter WIMPs, through the Ge nuclear recoil produced by the WIMP elastic scattering. A new exclusion plot, has been derived for WIMP-nucleon spin-independent interactions. To obtain this result, 40 days of data from the IGEX detector (energy threshold E \~ 4 keV), recently…
▽ More
One IGEX 76Ge double-beta decay detector is currently operating in the Canfranc Underground Laboratory in a search for dark matter WIMPs, through the Ge nuclear recoil produced by the WIMP elastic scattering. A new exclusion plot, has been derived for WIMP-nucleon spin-independent interactions. To obtain this result, 40 days of data from the IGEX detector (energy threshold E \~ 4 keV), recently collected, have been analyzed. These data improve the exclusion limits derived from all the other ionization germanium detectors in the mass region from 20 GeV to 200 GeV, where a WIMP supposedly responsible for the annual modulation effect reported by the DAMA experiment would be located. The new IGEX exclusion contour enters, by the first time, the DAMA region by using only raw data, with no background discrimination, and excludes its upper left part. It is also shown that with a moderate improvement of the detector performances, the DAMA region could be fully explored.
△ Less
Submitted 16 January, 2002; v1 submitted 25 October, 2001;
originally announced October 2001.
-
Recent results from the canfranc dark matter search with germanium detectors
Authors:
I. G. Irastorza,
A. Morales,
C. E. Aalseth,
F. T. Avignone III,
R. L. Brodzinski,
S. Cebrian,
E. Garcia,
D. Gonzalez,
W. K. Hensley,
H. S. Miley,
J. Morales,
A. Ortiz de Solorzano,
J. Puimedon,
J. H. Reeves,
M. L. Sarsa,
S. Scopel,
J. A. Villar
Abstract:
Two germanium detectors are currently operating in the Canfranc Underground Laboratory at 2450 m.w.e looking for WIMP dark matter. One is a 2 kg 76Ge IGEX detector (RG-2) which has an energy threshold of 4 keV and a low-energy background rate of about 0.3 c/keV/kg/day. The other is a small (234 g) natural abundance Ge detector (COSME), of low energy threshold (2.5 keV) and an energy resolution o…
▽ More
Two germanium detectors are currently operating in the Canfranc Underground Laboratory at 2450 m.w.e looking for WIMP dark matter. One is a 2 kg 76Ge IGEX detector (RG-2) which has an energy threshold of 4 keV and a low-energy background rate of about 0.3 c/keV/kg/day. The other is a small (234 g) natural abundance Ge detector (COSME), of low energy threshold (2.5 keV) and an energy resolution of 0.4 keV at 10 keV which is looking for WIMPs and for solar axions. The analysis of 73 kg-days of data taken by COSME in a search for solar axions via their photon Primakoff conversion and Bragg scattering in the Ge crystal yields a 95% C.L. limit for the axion-photon coupling g < 2.8 10^-9 GeV^-1. These data, analyzed for WIMP searches provide an exclusion plot for WIMP-nucleon spin-independent interaction which improves previous plots in the low mass region. On the other hand, the exclusion plot derived from the 60 kg-days of data from the RG-2 IGEX detector improves the exclusion limits derived from other ionization (non thermal) germanium detector experiments in the region of WIMP masses from 30 to 100 GeV recently singled out by the reported DAMA annual modulation effect.
△ Less
Submitted 27 November, 2000;
originally announced November 2000.
-
New constraints on WIMPs from the Canfranc IGEX dark matter search
Authors:
A. Morales,
C. E. Aalseth,
F. T. Avignone III,
R. L. Brodzinski,
S. Cebrian,
E. Garcia,
D. Gonzalez,
W. K. Hensley,
I. G. Irastorza,
I. V. Kirpichnikov,
A. A. Klimenko,
H. S. Miley,
J. Morales,
A. Ortiz de Solorzano,
S. B. Osetrov,
V. S. Pogosov,
J. Puimedon,
J. H. Reeves,
M. L. Sarsa,
S. Scopel,
A. A. Smolnikov,
A. G. Tamanyan,
A. A. Vasenko,
S. I. Vasiliev,
J. A. Villar
Abstract:
The IGEX Collaboration enriched 76Ge double-beta decay detectors are currently operating in the Canfranc Underground Laboratory with an overburden of 2450 m.w.e. A recent upgrade has made it possible to use them in a search for WIMPs. A new exclusion plot has been derived for WIMP-nucleon spin-independent interaction. To obtain this result, 30 days of data from one IGEX detector, which has an en…
▽ More
The IGEX Collaboration enriched 76Ge double-beta decay detectors are currently operating in the Canfranc Underground Laboratory with an overburden of 2450 m.w.e. A recent upgrade has made it possible to use them in a search for WIMPs. A new exclusion plot has been derived for WIMP-nucleon spin-independent interaction. To obtain this result, 30 days of data from one IGEX detector, which has an energy threshold of ~4 keV, have been considered. These data improve the exclusion limits derived from other germanium diode experiments in the ~50 GeV DAMA region, and show that with a moderate improvement of the background below 10 keV, the DAMA region may be tested with an additional 1 kg-year of exposure.
△ Less
Submitted 21 February, 2000;
originally announced February 2000.
-
A Decommissioned LHC Model Magnet as an Axion Telescope
Authors:
K. Zioutas,
C. E. Aalseth,
D. Abriola,
F. T. Avignone III,
R. L. Brodzinski,
J. I. Collar,
R. Creswick,
D. E. Di Gregorio,
H. Farach,
A. O. Gattone,
C. K. Guerard,
F. Hasenbalg,
M. Hasinoff,
H. Huck,
A. Liolios,
H. S. Miley,
A. Morales,
J. Morales,
D. Nikas,
S. Nussinov,
A. Ortiz,
E. Savvidis,
S. Scopel,
P. Sievers,
J. A. Villar
, et al. (1 additional authors not shown)
Abstract:
The 8.4 Tesla, 10 m long transverse magnetic field of a twin aperture LHC bending magnet can be utilized as a macroscopic coherent solar axion-to-photon converter. Numerical calculations show that the integrated time of alignment with the Sun would be 33 days per year with the magnet on a tracking table capable of $\pm 5^o$ in the vertical direction and $\pm 40^o$ in the horizontal direction. Th…
▽ More
The 8.4 Tesla, 10 m long transverse magnetic field of a twin aperture LHC bending magnet can be utilized as a macroscopic coherent solar axion-to-photon converter. Numerical calculations show that the integrated time of alignment with the Sun would be 33 days per year with the magnet on a tracking table capable of $\pm 5^o$ in the vertical direction and $\pm 40^o$ in the horizontal direction. The existing lower bound on the axion-to-photon coupling constant can be improved by a factor between 50 and 100 in 3 years, i.e., $g_{aγγ} \lesssim 9\cdot 10^{-11} GeV^{-1}$ for axion masses $\lesssim$ 1 eV. This value falls within the existing open axion mass window. The same set-up can simultaneously search for low- and high-energy celestial axions, or axion-like particles, scanning the sky as the Earth rotates and orbits the Sun.
△ Less
Submitted 22 January, 1999; v1 submitted 18 January, 1998;
originally announced January 1998.